LICO HDL3 & HDL5, certified EN54-5-Heat- & Fire-Detectors

Similar documents
EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

GET ALARMED IF NECESSARY Overheat & Fire Smoke Overflow Flow

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

DAF DETECT-A-FIRE. DAF DETECT-A-FIRE Detection and Release Devices

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Explosion-proof Immersion Heater Type D-8660

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Flameproof Manual Call Points Series MCP

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

Operating Instructions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

INSTRUCTION MANUAL (ATEX / IECEx)

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

FSW300 Series Flow Switch

Dräger Polytron SE Ex Fixed Gas Detector

1592P01. for liquids in piping DN

Explosion Proof Manual Call Points Series MCP

AZN ATEX INSTALLATION AND MAINTENANCE

Flameproof Manual Call Points

Flameproof Manual Call Points Series MCP

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Dräger Polytron 5720 IR Toxic Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Fan Heaters Type VLEx

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

manual addendum DELPHI Ex

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

S5000 Gas Monitor. GMS5000.com

Manual Alarm Call Points

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SOLUZIONI PER ATMOSFERA ESPLOSIVA

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

OLC(T) 100 FIXED GAS DETECTOR

Screw plug immersion heaters

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8200 Stationary gas detector (CatEx)

TBSF/CBSF Stainless Steel Flat Roof Screwed Terminal Box Zones 1&2, 21&22

Dräger Polytron 8700 IR Detection of flammable gases and vapors

3M Oldham OLCT 100. Description. Fixed Gas Detector

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Detect Heat and prevent Overheat, Fire, Explosion with custom made Industrial Heat & Fire Detectors from 60 C - until 510 C

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Illumination unit For sight glass level indicator Model LGI

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Lamp Supply (Recommended)

Dräger Polytron 5100 EC Detection of toxic gases and vapors

VQ600 Datasheet. Pellistor Gas Sensor for Hazardous Areas (Fixed Systems) FEATURES TECHNICAL SPECIFICATION OPERATION

ULTIMA X5000. MSAX5000.com

Temperature Measurement Transmitters for field mounting

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

ExPolar Heating System

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Flange immersion heaters

IR15 Dual Gas Series Datasheet

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Snifter ATEX22 VERSION. User Manual. Distributor

LTFX Electric Tank Immersion Heaters Installation Instructions

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

DETECT-A-FIRE Heat Detectors

DICTATOR Hold-Open Systems for Hazardous Areas

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

TYPE APPROVAL CERTIFICATE

DB4 Range - SPEAKERS - Up to 25 Watts

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Sinus Jevi (Explosion-Proof) Condens Heaters

ATEX catalogue book SOLUTIONS FOR EXPLOSIVE ATMOSPHERES

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

Explosion Proof Combination Signal db (A) / 5 Joule

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

IR25 Dual Gas Series Datasheet

Cable Glands DB Series: Drain, Breather Valves and Unions

Transcription:

LICO HDL3 & HDL5, certified EN54-5-Heat- & Fire-Detectors Detect Heat and prevent Overheat, Fire & Explosion Heat detector Ready to install units Custom made Alarmpanels Email: office @lico.at sales@lico.at LICO develops and manufactures in the EU

HDL-3 & HDL-3 XL Heat- & Fire-Detector Variations: Commercial & Standard Sauna: HDL-3 / HDL-3-XL EN54-5 Ex*: Recommended for any kind of industrial and commercial applications where there are EN54-5 and/or ATEX/Ex-requirements. Solid, easy to use & very price economic heat detector units. Designed until 150 C permanent temp. applications. Application: - Saunas, Power plants, Engine rooms, - Heating rooms, Air-filter / Duct Systems, - Chemical plants, Production lines - Transformer stations, Factories, Kitchens, - Ceilings, Switch board cabinets etc. Individual HDL-3 XL constructions: Sensors are mounted with maximum torque of 27 Nm and sealed with special, high temperature sealant. Cable glands are mounted & fixed with counter nut and sealed with special, high temperature sealant. Double thread allows unique through wall installation possibilities using the Detect-A-Fire-Sensor with Coupling Head 28020-003 or 28021-005. The Junction Box may stay at the cooler part of the installation. *Housing ATEX/IECEx-certified: Ex ll 2 GD, Ex e/ib llc Gb, Ex tb IIIC Db IP6X* - 40 C /+80 C with Neoprene seal, - 70 C/+130 C with Silicone-seal, - IP67, Internal & external ground-connection saltspray-safe, vibration- & shock proven Wiring Terminal: up to 130 C ATEX/IECEx certification Standard ATEX/IECEx certified Cable Gland Variations: - 20 - + 80 C with Neoprene seal, IP66/68-40 - +100 C with EPDM-seal, IP66/68 70 - +220 C with Silicone-seal, IP66/68 Options/ Accessories: - oil-resistant mounting of Heat Detector and Cable gland - 2. Cable gland - Series und EOL End of Line Resistors - Very High Temperature Silicone Sealings HDL-3 Standard Size junction box dimensions: Unit Outside L. Outside W. Inside L. Inside W. Height HDL3 HDL3-XL 80 80 75 125 68 68 63 113 57 57 HDL-3 XL with 2 cable glands For bespoken, custom made units please contact LICO

HDL-5-EN54-5 Very High Temperature Heat- & Fire-Detector HDL-5-EN54-5: Recommended for any kind of high temperature industrial and commercial applications where there are EN54-5 and or ATEX/ Ex requirements. Simply easy, very price economic and reliable Heat & Fire Detector unit. Designed until 220 C ATEX-certified permanent temperature applications. The real max. operational temperature can be higher. Sensors are mounted with maximum calibrated torque tool of 27 NM and sealed with special, high temperature sealant. Cable glands are mounted & fixed with counter nut and sealed with special, high temperature sealant. Double thread allows unique through wall installation possibilities use with Sensor 28020-003 or 28021-005. The Junction Box may stay at the cooler part of the installation Detect-A-Fire-Sensor with Coupling Head. *Housing ATEX/IECEx-certified: Ex ll 2 GD, Ex e/ib llc Gb, Ex tb IIIC Db IP6X* - 70 C/+220 C with Silicone-seal, - IP67 - Ceramic Wiring Terminals: ATEX/IECEx-certified:: ATEX certified until 210 C, max op.temp: >300 C Standard ATEX/IECEx Cable gland : ATEX certified 70 - +220 C with Silicone-seal, IP66/68 Options/ Accessories: - oil-resistant mounting of Heat Detector & Cable Gland - 2. Cable gland - Cement based ultra high temperature Series and EOL End of Line Resistors - Ultra high temperature Silicone Sealings HDL-3 & HDL 5 Components are Certified according to: (for further info and actual certificate please contact LICO) HDL-5 Standard Size junction box dimensions: HDL-5 Outside L. Outside W. Inside L. Inside W. Height Standard 120 122 104 88,5 80 Custom specific HDL-5 constructions For bespoken, custom made boxes please contact LICO

HDL3-EN54-5 & HDL5-EN54-5 part numbers Model HDL Size Sensor Housing Switch Sensor body Nominal Temperature Sensor mounting Wiring block Entries Type Seal Lid Resistor 3-EN54-5 3XL-EN54-5 5-EN54-5 Threads: -S Single -D Double -1 NO -2 NC -BR Brass -ST Stainless C / F 60 / 140 71 / 160 88 / 190 99 / 210 107 / 225 135 / 275 165 / 325 187 / 360 * 232 / 450 * -L Lid -B Box -S Standard -C Ceramic -1 One -2 Two -A M16 thread -B M20 thread -C Cable Gland -N None -E EOL -S Series -B Both -1 HT Silicone -2 Neopren -3 EPDM -4 other *tested but above EN-54-5 Temp. range Sample Purchase order number: HDL3-EN54-5-S -1 -BR 135 -B -S -1 -C -1 -N Examples of order numbers: for Sauna & Standard Commercial for High Temperature: HDL3-EN54-5-S-1-BR135-B-S-1-C-1-N HDL5-EN54-5-S-1-ST165-B-C-2-C-1-B Restrictions: 1. 2 or + Entries only in size HDL3XL and HDL5 2. Resistors: only in size HDL3XL and HDL5 3. Double thread Sensor mount: only mount in box, never into lid 4. Nominal max. Operating Temperature: Standard wiring block 135 C+, Ceramic wiring block: 220 C+ 5. Ceramic wiring block: available only @ HDL5 6. General mounting: if not otherwise specified the sensor would be mounted 180 opposite to the cable-gland Screw-in-pod: On request: Weld-in- and Screw-in-pods ( Stainless or PTFE or...) ExD Housings Stainless-steel housings Stainless-steel cable glands

Dimensions: HDL3 Weight: HDL3: HDL3XL: HDL5: 620g net 765g net 1310 g net Custom tariff no.: 8531 1030 HDL3XL HDL5 Disclaimer: All the herein given specifications, dimensions, weights, temperatures and tolerances and other values are nominal (typical) and LICO reserves the right to vary all data without prior notice. No liability is accepted for any consequence of use.

Available Standard Fenwal DAF Sensor Variations: Single Thread units: Brass & Stainless Steel or Fully Stainless steel N/C (2 wire) Opens at temperature rise or N/C (4-wire) Closes at temperature rise 2-wire unit N/C, Opens at Rise 4-wire unit N/O, Closes at Rise Sensor Housing Stainless Steel Sensor Housing Stainless Steel Body Brass Body Stainless Body Brass Body Stainless Nominal Switching temperature 27120-000-140 27120-022-140 27121-000-140 27121-020-140 60 C / 140 F 27120-000-160 27120-022-160 27121-000-160 27121-020-160 71 C / 160 F 27120-000-190 27120-022-190 27121-000-190 27121-020-190 88 C / 190 F 27120-000-210 27120-022-210 27121-000-210 27121-020-210 99 C / 210 F 27120-000-225 27120-022-225 27121-000-225 27121-020-225 107 C / 225 F 27120-000-275 27120-022-275 27121-000-275 27121-020-275 135 C / 275 F 27120-000-325 27120-022-325 27121-000-325 27121-020-325 165 C / 325 F 27120-000-360 27120-022-360 27121-000-360 27121-020-360 187 C / 360 F 27120-000-450 27120-022-450 27121-000-450 27121-020-450 232 C / 450 F 27121-000-500 27121-020-500 260 C / 500 F 27121-000-600 27121-020-600 315 C / 600 F 27121-000-725 27121-020-725 385 C / 725 F Double Thread (Coupling Head) units: Fully Stainless steel in 2 Versions: N/C (2 wire) Opens at temperature rise N/C (4-wire) Closes at temperature rise Class 1, Group A requires fully Stainless-steel Fenwal DAF-versions! 2-wire unit 4-wire unit N/C, Opens at Rise N/O, Closes at Rise Nominal Switching Sensor Housing Stainless Steel Sensor Housing Stainless Steel temperature Body Brass Body Stainless Body Brass Body Stainless 28020-003-140 28021-005-140 60 C / 140 F 28020-003-160 28021-005-160 71 C / 160 F 28020-003-190 28021-005-190 88 C / 190 F 28020-003-210 28021-005-210 99 C / 210 F 28020-003-225 28021-005-225 107 C / 225 F 28020-003-275 28021-005-275 135 C / 275 F 28020-003-325 28021-005-325 165 C / 325 F 28020-003-360 28021-005-360 187 C / 360 F 28020-003-450 28021-005-450 232 C / 450 F 28021-005-500 260 C / 500 F 28021-005-600 315 C / 600 F 28021-005-725 385 C / 725 F

Custom Made Fire Prevention Solutions from LICO! Contact us:, office@lico.at Tel: +43 1 706 43 00 Fax: +43 1 706 41 31 LICO Mecatronic S.R.L. RO-540526 Targu-Mures, Str.Bucinului Nr.2B Romania. office@lico.ro Tel: +40 365 807 497 Fax: +40 365 434 999 LICO Hungaria Kft, Raba u.4, H-2030 Erd, Hungary sales@lico.hu / h.miksch@lico.at Tel: +36 23 520 113 Fax: +36 23 520 115 w w w. p r e v e n t - a - f i r e. e u