WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Similar documents
1020 Industrial Drive, Orlinda, TN fax

Ultraviolet Water Sterilizer Installation and Maintenance Manual

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

SLT-Series Installation and maintenance instructions

INSTALLATION & MAINTENANCE

UV I UNIT030W / UV I UNIT055W

NANO TECH UV-C DISINFECTION SYSTEM

UV Lamp and Quartz Sleeve Replacement/Maintenance

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

ULTRA-VIOLET STERILIZATION

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

SimplyClear Pressurized Filter Product Manual

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Pressurized Filter Up to 1250 gallons

Document No A3 Revised February Atlantic Ultraviolet Corporation

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

Instruction Sheet DANGER

Document No B1 February Atlantic Ultraviolet Corporation

Instruction Sheet DANGER

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

Ballast MIN A

Aquience 1200/1500 R

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Document No A9 Revised August Atlantic Ultraviolet Corporation

AEM EASY DRUM M A N U A L

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

Document No E1 Revised February Atlantic Ultraviolet Corporation

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

ADVANCE Ultraviolet (UV) Water Treatment System

Ozone + UV Sanitation

Ultraviolet (UV) Water Treatment System

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

ARUBA SUN SERIES - LIGHTING SYSTEM USER MANUAL

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

PRE INSTALLATION PROCEDURES

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

gamma pond Ultraviolet Sterilizers

A measured step forward

Ultraviolet (UV) Disinfection System Model RC8

Pro-MAX Ultraviolet Sterilizer

GRU-V Air Purifier. Product Manual

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Customized Drinking Water

Large Direct-Pure EDI Water System. User Manual. RephiLe Bioscience, Ltd.

AllClear G2 Series Pressurized Filters Product Manual

Owner s Manual. Installation, Operation & Maintenance. Models B B B3 RoHS

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

16 OUTDOOR MISTING FAN

CRISTAL Built-in Dish Sterilizer Instruction Manual

SolidFlo G2 Solid Handling Pumps Product Manual

BWT ECO. Fitting and operating instructions. Ultra Violet Water Disinfection System. ECO Range: LC 8 UV LC19 UV LC36 UV LC51 UV

Direct-Pure Water System. User Manual

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

WEDECO Quadron UV System

Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Model CWA200 Owner s Manual

(UV) - R830F & ) INTRODUCTION

PCR UV cabinets DNA/RNA

Ultraviolet Disinfection Unit Installation and Owners Manual

Installation and Maintenance Manual

Installation manual plugs and connectors QUICK-CONNECT (63 A)

SuperKlean Washdown Products

Document No C Revised January Atlantic Ultraviolet Corporation

OWNERS MANUAL. Operation & Installation Instructions

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

Vacuum Cleaner. user manual. Please read the User Manual thoroughly before operating the vacuum. For indoor use only.

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

NO4G, NO4GS, NO6G, NO6GS

Pond Pump 280 / 420 / 575. Operating instructions Notice d emploi Instrucciones de uso

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

MOBILE PARTS WASHER MODEL No: CWM20

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

Model AD30-2. Document No B3 Revised November Atlantic Ultraviolet Corporation

User Instruction Manual

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

ULTRA-VIOLET STERILIZATION

Installation Instructions. Mira LED Light System

TECHNICAL MANUAL TM... Fryer, Deep-Fat, Electric w/solid State Controls 440 Volt, 60 HZ, 3 Phase NSN:

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

Heater Upgrade Instructions

254 Nanometer Germicidal UV Disinfection Systems

PCR UV cabinets DNA/RNA

ULTRASONIC humidifier

Transcription:

WATER UV STERILIZERS WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15 MANUAL Patent nr 204935-2012 -

2 User Safety! Warning This device may only be operated and installed by qualified personnel. Before installation, servicing or repairs verify the qualifications of personnel and limit these activities to such personnel. Any activities on this device can only proceed after thorough familiarization with this instruction. Noncompliance with the precautions listed hereon might expose personnel to serious bodily harm (damage to human skin from UV radiation), or damage to the device alone. The manufacturer,, is not responsible for damage to the device caused by improper instillation, maintenance and operation. 1. READ THE MANUAL. Before proceeding with any activity with the sterilizers read the manual. 2. RETAIN THE MANUAL. Retain the manual for reference during the whole time the device is in operation. All precautions and warnings shall be obeyed by the user at all times during the operation of the device. 3. POWER SUPPLY. Device is exclusively designed to be supplied from 220-230V 50Hz mains. It shall be installed and grounded in accordance with this manual and the local electrical code. To guard against electrical shock, unplug the device every time work is to be done on it. 4. GROUNDING. Operation of the device without connected grounding is inadmissible. Ungrounded operation might lead to occurrence of electrical shock and serious bodily harm with death included. 5. ULTRAVIOLET RADIATION. Direct exposure to UV radiation is harmful to human skin and sight, which can cause from reddening of skin to serious burns, or ultimately loss of eyesight, depending on the time of exposure. In such cases one shall contact physician as soon as possible. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

3 Instalation and operation instructions Thank you and congratulations on your purchase of manufactured UV sterilization product. Sterilizers made by are made from highest quality stainless steel. The thickness of the chamber wall guarantees high factor of safety in operation. All the raw materials and components are of best quality and were processed or manufactured in the EU countries. Plastics used in production of the lamp hoods withstand 110 C working temperatures. Devices completed successfully 30 Atm pressure trials. In AM models we introduced additional guides for the quartz sleeves easing the assembly and disassembly. This solution allows the same ease of assembly for device working horizontally or vertically. This guide prevents the quartz sleeve from breaking during the routine maintenance. The turbulent flow induced by the guide increases the efficaciency of disinfection. During the first 100 hours of operation the efficiency of disinfection is greater by 15% from the rated for the device. New features allow continuing disinfection even without the flow of water through the chamber. The design of the chamber contributes to lower incidence of sediment from calcium and magnesium on the surface of the quartz sleeve. The AM models are equipped with more durable amalgamate lamps up to 12,000 hours of service. The plastic lamp hood has a secondary function as a sight glass. This innovative solution of the use of transparent to visible light lamp hoods allows optical indication of the state of the lamp. We hold high hopes that the implementations of these innovative solutions fulfill your expectations for new and more efficient products from. 1. Introduction The device delivered to you is disassembled and shall be protected from severe shocks and drops, as the quartz sleeve and lamps are brittle and fragile. The sterilizer shall be exclusively transported in horizontal position. The manufacturer is not responsible for damage arising from the conditions of transport. Before installation and operation one shall read the instructions and implement the precautions listed. Noncompliance with these precautions is grounds for releasing the manufacturer from warranty obligations Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

4 2. Applications Disinfection with UV radiation is a reliable, simple and inexpensive method of sterilization. The use of this method is warranted every time microbiological risk exists. Following applications might be listed, among many others: - Potable water in private and municipal installations - Potable and process water in restaurant and hotel business - Process water in the production of medicines and cosmetics - Water used in processing food - Water in beverage production - Water in swimming pools - Control of green algae in ponds The primary advantage of UV sterilization is water without microbes and damaging chlorine so often used in sterilization of water. Sterilizer uses special low pressure UV lamp to produce UV radiation of wavelength of 254 nm which causes photochemical reaction damaging DNA of microorganisms leading to death or sterility. The requirements for complete sterilization call for minimum dosage of 300J/ m 2 for potable water. Water flowing from the sterilizer is ready for immediate use. UV Sterilization does not change the chemical makeup of water There is no danger of overdosing either. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

5 3. Technical Specifications: 317 O220 DN 100 250 WORKING HOURS 400 250 SYSTEM WORK CONTROL S /RED/ 709 1110 POWER /GREEN/ 600 221 SOLENOID VALVE TERMINAL UV LAMPS POWER CORD MODEL AM4 TECHNICAL SPECIFICATIONS: Model AM1 AM2 AM3 AM4 AM5 Power Supply 220V-230V Chamber Material Stainless Steel Finish Mirror Finish Dimensions /length. x width x height./mm 317x220x1110 317x250x1110 335x285x1110 Connection Size/Separation Dist.. DN80/ 735mm DN100/ 735mm DN100/ 735mm DN125/ 709mm DN150/ 683mm No. of UV Lamps x Nominal Power 1x130W 2 x130w 3 x130w 4 x130w 5 x130w Life of UV Lamps ~ 12 000 h Operating Temperature 0.5-50 0 C Operating Pressure 10bar(1MPa) UV Power @y 254nm 46 W 92 W 138 W 184 W 230 W Nominal Power 160 W 320 W 480 W 640 W 800 W Nominal Flow @ transmittance T10=95%, dose 300J/m 2 25,0 m 3 /h 45,0 m 3 /h 78,0 m 3 /h 100,0 m 3 /h 144,0 m 3 /h Nominal Flow @ transmittance T10=95%, dose 400J/m 2 18,7 m 3 /h 34,0 m 3 /h 58,0 m 3 /h 75,0 m 3 /h 108,0 m 3 /h Sight glass Muff 1 2 3 4 5 Drain Valve Orientation Horizontal/Vertical Material Plastic Steel Safety Class IP 42 IP32 Dimensions /mm 325x250x120 400x400x200 400x600x250 Audible UV Lamp Fault Alarm Optical UV Lamp Fault Indicator Working Hours Counter Alarm System Solenoid Cut-Off Valve Terminals Terminals for Remote Alarm Indicator Remote ON/OFF Switch Terminals Weight with Enclosure 96.0kg 98.0kg 100.0kg 115.0kg 125.0kg UV Intensity Measurement System By Order /Optional/ Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

6 488 395 O356 DN 250 600 250 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 575 1120 800 POWER /GREEN/ 292,5 SOLENOID VALVE TERMINAL UV LAMPS POWER CORD MODEL AM10 TECHNICAL SPECIFICATIONS: Model AM6 AM8 AM10 AM12 AM15 Power Supply 220V-230V Chamber Material Stainless Steel Finish Mirror Finish Dimensions /length. x width x height./mm 463x340x1100 488x395x1120 544x445x1130 Connection Size/Separation Dist DN200/619mm DN250/575mm DN300/521mm No. of UV Lamps x Nominal Power 6 x130w 8 x130w 10 x130w 12 x130w 16 x130w Life of UV Lamps ~12 000 h Operating Temperature 0.5-50 0 C Operating Pressure 10bar(1MPa) UV Power @ 254nm 276W 368W 460 W 552 W 736W Nominal Power 960 W 1280 W 1600 W 1920 W 2560 W Nominal Flow @ transmittance T10=95%, dose 300J/m 2 201,0 m 3 /h 287,0 m 3 /h 430,0 m 3 /h 526,0 m 3 /h 730,0 m 3 /h Nominal Flow @ transmittance T10=95%, dose 400J/m 2 151,0 m 3 /h 215,0 m 3 /h 322,0 m 3 /h 395,0 m 3 /h 550,0 m 3 /h Sight glass Muff 6 pcs. 8 pcs. 10 pcs. 12 pcs. 16 pcs. Drain Valve Orientation Horizontal/Vertical Material Steel Safety Class IP 32 Dimensions /mm 400x600x250 600x800x250 800x800x250 Audible UV Lamp Fault Alarm Optical UV Lamp Fault Indicator Working Hours Counter Alarm System Solenoid Cut-Off Valve Terminals Terminals for Remote Alarm Indicator Remote ON/OFF Switch Terminals Weight with Enclosure 195.0kg 200.0kg 240.0kg 250.0kg 280.0kg UV Intensity Measurement System By Order /Optional/ Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

7 Minimal flow of water is not required. Increased flow through the sterilizer lowers the dosage delivered to microorganisms and lowers efficiency of disinfection, however, it allows for use in installations without the need for additional bypasses. Standard Features: - electrical enclosure, - lamp working hours counter, - audible and optical alarm - terminals for connecting electromagnetic valve shutting off flow in case of power or lamp failure Optional Accessories: 1. UV intensity sensor. 4. Description Sterilizer s chamber is made from stainless steel. Quartz sleeves with UV lamps are mounted in the chamber. When mounted vertically, the inlet should be located in the bottom part of the chamber and the outlet in the upper part. When mounted horizontally, the arrangement is optional. At the bottom of the chamber the drain plug is located, which is used to empty the chamber from fluid. The power supply system is mounted in the electrical enclosure and connected with the sterilizer by hi-potential wires. The enclosure houses, besides the power supply, the lamp working hours counter, the audible and optical alarm, and indicating lights with the terminals for electromagnetic shutoff valve in case of lamp or power failure. 4.1. Leading out the alarm signal in AM1 model To the terminals 1 & 2 on electronic plate /neutral/ connect alarm signal. Contacts closed - sterilizer working properly Contacts open - UV lamp damage - Alarm on - Power cut off 4.2. Connection of solenoid valve in AM1 model To the terminals 1 & 2 /neutral/ on the electronic plate in electrical enclosure/ connect solenoid valve type NZ (normally closed) max. 2a. Contacts closed - sterilizer working properly Contacts open - UV lamp damage - Alarm on - Power cut off 4.3. Remote-controlled switch in AM1 model After removing the bridge, it is possible to connect remote-controlled switch to the terminals ON/OFF /caution: voltage 230V!/. Contacts closed - sterilizer on Contacts open - sterilizer off Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

ZASILANIE 8 POWER LINE REMOVE THE DOORS OF THE ELECTRICAL ENCLOSURE 1 SOLENOID VALVE OUTLET Zasilanie elektrozaworu ELECTRONIC PLATE IN AM1 MODELS bezpiecznik UV STERILIZER 1 2 ~230V BALAST COUNT ON/OFF SWITCH N To the terminals 1 & 2 /neutral/ on the electronic plate in electrical enclosure/ solenoid valve type NZ (normally closed) max. 2a can be connected. Circuit closed - sterilizer working properly Circuit open - UV lamp damage - Alarm on - Power cut off To the terminals ON/OFF / the sterilizer: Closed circuit - sterilizer on Open circuit - sterilizer off 4.4. Leading out the alarm signal in AM2-AM15 models To the terminals 1 & 2 /neutral/ on the terminal blocks in electrical enclosure /in the right bottom corner/ connect alarm signal. Contacts closed - sterilizer working properly Contacts open - UV lamp damage - Alarm on - Power cut off 4.5. Connection of solenoid valve in AM2-AM15 models To the terminals 1 & 2 /neutral/ on the terminal blocks in electrical enclosure/ connect solenoid valve type NZ (normally closed) max. 2a. Contacts closed - sterilizer working properly Contacts open - UV lamp damage - Alarm on - Power cut off 4.6. Remote-controlled switch AM2-Am15 models After removing the bridge, it is possible to connect remote-controlled switch to the terminals ON/OFF /caution: voltage 230V!/. Contacts closed - sterilizer on Contacts open - sterilizer off Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

9 POWER LINE REMOVE DOORS OF THE UV STERILIZER SOLENOID VALVE OUTLET SOLENOID VALVE CORD Blokada 1234 5 6 7 8 PE masa CONTACTOR QUICK-BREAK FUSE To the terminals 1 & 2 /neutral/ on the terminal blocks in electrical enclosure/ solenoid valve type NZ (normally closed) max. 2a can be connected. Circuit closed - sterilizer working properly Circuit open - UV lamp damage - Alarm on - Power cut off terminal block in electrical enclosure, after removing the jumper cable, connect remote switching on/off of the sterilizer: Closed circuit - sterilizer on Open circuit - sterilizer off Power supply specifications 220-230V + 8%, -10%, 50-60 Hz. Electric shock protection by earth terminal. Transparent lamp hood allows for indication of working condition of the lamp. 5. Instruction for installation and operation a) Device assembles in either vertical or horizontal position. Temperature range for installation is from 0.1 to 50 o C. b) Upstream of the intake install potable water filter, minimum rating 0.1 mm, recommended 0.05 mm. Water shall not contain more than 0.3mg Fe and 0.1 Mn. c) Install manual cut-off valves, upstream of the intake and downstream of the outlet. d) Mount electrical enclosure on wall, at least 60 cm from the floor. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

10 QUARTZ SLEEVE e) Slide in gently through the nipple the quartz sleeves; continue through sleeve guides onto nests at the bottom. WARNING!! QUARTZ SLEEVE IS WERY BRITTLE AND FRAGILE. BE CAREFUL. STERILIZER CHAMBER f) Place the o-ring over quartz sleeve and against the lip of the nipple. Next place the washer over the o-ring, screw the muff onto this assembly with the provided tool. Turn the muff to considerable resistance in order to tighten the seal. Tightening the muff shall not break the sleeve. O-RING ON MUFF QUARTZ SLEEVE MUFF O-RING WASHER STERILIZER CHAMBER QUARTZ SLEEVE O-RING STERILIZER CHAMBER Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

11 TIGHTEST SEAL AROUND THE QUARTZ SLEEVE SHALL BE CREATED WITH LARGE DEFORMATION OF O-RING. O-RING IS VISIBLE TROUGH THE SLEEVE. TIGHTEN MUFF WITH THE PROVIDED TOOL, AS SEEN. PROVIDED TOOL O-RING ON MUFF MUFF WASHER O-RING O-RING BEFORE MUFF BEING TIGHTENED /SMALL DEFORMATION OF O-RING/ QUARTZ SLEEVE STERILIZER CHAMBER O-RING AFTER BEING FULLY TIGHTENED, MUFF DEFORMS O-RING /SUFFICIENT DEFORMATION/ g) Fill the chamber under full pressure and check the seal tightness. h) Place the socket on the end for UV lamps with four pins. Slide in the fully connected lamps into the quartz sleeves. CAUTION! MOUNT UV LAMPS IN PROTECTIVE, PREFERABLY COTTON, GLOVES. If this requirement is not met, the UV lamp may break after the switching on of the sterilizer. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

12 STRAIN RELIEF STRAIN RELIEF LAMP HOOD LAMP HOOD SOCKET PLACE LAMP HOOD OVER MUFF PLACE SOCKET ON LAMP END WITH FOUR PINS CENTERING RING UV LAMP INSERT UV LAMP INTO QUARTZ SLEEVE SOCKET CENTERING RING UV LAMP MUFF O-RING ON MUFF WASHER O-RING QUARTZ SLEEVE STERILIZER CHAMBER i) Place lamp hood over muff. j) Plug in to mains 230V, 50 Hz, in the electrical enclosure, according to the labels. k) Turn device on by using switch on the side or front of electrical enclosure. Green indicator light goes on when device is connected to power and powered up. l) Replace UV lamps after 12,000 hours of work. ATTENTION! 1. Any fault of UV lamp, including burn out, is signalized by lighting up of red indicator lamp and tripping of audible alarm. 2. Incidental powering on the electrical enclosure without connected UV lamps may cause damage to electronic ballast driving UV lamps. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

13 ATTENTION! In the case of installing solenoid shut-off valve ( terminals 1 & 2) upstream /or downstream/ of the sterilizer, tripping alarm or power interruption causes immediate shutting off of fluid flow to the chamber of the sterilizer. Terminals 1 & 2 have internal connection broken in case of alarm tripping and as such are neutral. Power to solenoid shut-off valve shall be connected through terminals 1 & 2. Solenoid shut-off valve serves the purpose of preventing unsterilized fluid entering the installation downstream of the sterilizer in the case of power interruption or lamp failure. 6. Maintenance a) If any sediment is noticed on the surface of the quartz sleeve, it is recommended to immediately clean the sleeve. Negligence of this recommendation can cause drop in efficiency of sterilization. b) Any time the sleeve is cleaned or replaced it is recommended to unconditionally replace the o-ring creating the seal around the sleeve. c) When replacing the UV lamp, it is recommended, if it is necessary, to clean the sleeve. d) Inlet and outlet valves shall be opened slowly to prevent the rush of fluid hitting and damaging the quartz sleeve. e) It is not required to have constant or any flow through the chamber. Sterilizers are so designed that there may be no flow through the chamber with no damage issuing to the sterilizer. f) Ultraviolet radiation is damaging to skin and eyesight. g) Water not fit for consumption may require treatment i.e. deironing, softening or filtering. If any doubt, please contact your dealer. h) In case of high turbidity and waste water, the choice of equipment and efficiency should be made by the dealer. i) Avoid frequent turning on and off the equipment. One on-off cycle lowers the UV lamp life by about 10-20 hours. j) Flow rate through the device can be increased, however, this lowers the delivered dosage and lowers the efficiency of disinfection. k) Bioassay samples shall be collected into sterile opaque containers as not to expose the sample to the light to avoid photo reactivation of microorganisms, which can rebuild their damaged DNA in presence of light. l) In case the red indicator light is on, replacement of the UV lamp is necessary. The part number can be found on transparent plastic lamp hood placed over the muff. m) Even short lived surge, to above 254V, can damage the electronic ballast driving the UV lamps. n) Using faulty or post end of life UV lamps / end of life set about 12,000 working hours/ can lead to damage to electronic ballast located In the electrical enclosure. o) Excessive humidity and water inside the quartz sleeve can cause damage to the electronic ballast driving the UV lamp. p) The leakage current going into grounding is 1,5 ma for each UV lamp. 7. Instruction for replacement of UV lamp. In order to replace the UV lamp one shall: a) Disconnect from power supply /neutral and life/, b) Put on protective gloves, preferably made of cotton, c) Take off plastic hood, Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

14 d) Slide out the UV lamp from the quartz sleeve, e) Take off socket from the ends of UV lamp, f) Place socket on the end of a new UV lamp and slide it into the sleeve g) Reverse the remaining steps. ATTENTION! In model AM sterilizers UV lamps must have special centering ring at both ends. When the UV lamps are shipped from the manufacturer, the centering rings are provided with every lamp. 8. Replacement and Clearing of the Quartz Sleeve (Warning: Very brittle). In order to replace quartz sleeve one shall: a) Remove UV lamp according to p. 7. /Instruction for replacement of UV lamp/, b) Unscrew muff, c) Remove washer and o-ring from the quartz sleeve, d) Slide the sleeve out of guides and nipple of the sterilizer, e) Clean thoroughly the sleeve using generally available glass cleaners, dry the interior of the sleeve, ATTENTION!!! SLEEVE IS MADE OF PURE QUARTZ AND IS VERY BRITTLE. f) Slide carefully the new or cleaned quartz sleeve into the chamber of the sterilizer, g) Place new o-ring over the sleeve, then place the washer, h) Tighten the muff over the o-ring and washer with the provided tool. Check the proper placement of the o-ring, it should be lodged into the conical groove in the nipple of the sterilizer, i) Open gradually the cut-off valves, flood the chamber, and check the seal around the sleeve. If it springs a leak, tighten the muff till tight seal is obtained, j) Place the UV lamp according with p. 7 of this Manual. Warning! At the time of replacement or clearing of the quartz sleeve the o-ring must be replaced. 9. Transport Ship sterilizer only in horizontal position. It should be disassembled for shipping. The quartz sleeve and lamp should be packed separately as they are brittle. They should be sufficiently well packed to withstand rough handling. 10. Warranty Manufacturer grants warranty for the period of 60 months from the date of sale on the chamber made from stainless steel. Power supply and control circuitry is on 24 months warranty. Warranty does not cover the UV Lamps and the quartz sleeve. The manufacturer cannot be held liable for any damages arising from use or failure of the equipment. The warranty covers only replacement or repair of faulty parts or equipment Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

15 A. LEGEND FOR LIGHT ON ENCLOSURE Lighted colour indicator lights inform the operator of the status of the the sterilizer. Certain conditions can be identified from the configuration of lights. For these corrective actions are listed below: Alarm System Light Power Red Light Green Light Green LIght Problem Action OFF ON ON No fault - OFF OFF OFF No Power Check power source ON OFF ON 1.Burn out or faulty 1. New UV lamp UV lamp 2. New ballast 2.Faulty ballast Contact Dealer. OFF ON Alarm System Fault New alarm OFF system. B. TROUBLESHOOTING Problem Cause Action Burn out UV Lamp Water inside the quartz sleeve -. short circuit open circuit on circuit breaker Muff not tightened sufficiently. Worn out o-ring Take quartz sleeve out, dry interior, change o-ring, and assemble back. Tighten muff. If UV lamp does not work electronic ballast damaged replace contact dealer UV lamp goes off End of life of lamp caused by number of working hours and number on-off cycles. Replace UV lamp. Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

ZASILANIE 16 ULTRAVIOLET WATER STERILIZER DWG# TITLE AM1, AM2 - GENERAL ARRANGEMENT 1 DN80 317 735 1110 200 O220 WORKING HOURS 250 208 325 120 POWER CABLE UV LAMP CABLE SOLENOID VALVE CORD /TERMINALS 1&2/ REMOTE /TERMINALS 3&4/ MODEL AM1 317 DN100 220 WORKING HOURS 400 O220 200 735 1110 SYSTEM WORK CONTROL /RED/ 400 SOLENOID VALVE CORD POWER /GREEN/ 208 UV LAMP POWER CORD MODEL AM2 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

17 ULTRAVIOLET WATER STERILIZER DWG# TITLE AM3, AM4 - GENERAL ARRANGEMENT 2 O220 317 220 DN 100 735 1110 WORKING HOURS SYSTEM WORK CONTROL S /RED/ POWER /GREEN/ 400 250 600 208 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM3 317 O220 DN 100 250 WORKING HOURS 400 250 SYSTEM LAMP LIGHTS /RED/ 709 1110 POWER LIGHT /GREEN/ 600 221 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM4 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

18 ULTRAVIOLET WATER STERILIZER DWG# TITLE AM5, AM6 - GENERAL ARRANGEMENT 3 335 285 O256 DN 150 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 400 250 683 1110 POWER /GREEN/ 600 236 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM5 463 268 340 O306 DN 200 WORKING HOURS SYSTEM WORK CONTROL 400 250 S /RED/ 619 1110 POWER /GREEN/ 600 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM6 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

19 ULTRAVIOLET WATER STERILIZER DWG# TITLE AM8, AM10 - GENERAL ARRANGEMENT 4 463 340 O306 DN 200 600 250 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 800 619 1110 POWER /GREEN/ 268 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM8 488 395 O356 DN 250 600 250 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 575 1120 POWER /GREEN/ 800 292,5 SOLENOID VALVE CORD UV LAMP CORDS POWER CORD MODEL AM10 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

20 ULTRAVIOLET WATER STERILIZER DWG# TITLE AM12, AM15 - GENERAL ARRANGEMENT 5 544 O406 445 DN 300 800 250 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 521 1130 POWER /GREEN/ 800 323 SOLENOID VALVE TERMINAL UV LAMPS POWER MODEL AM12 544 O406 445 DN 300 800 250 WORKING HOURS SYSTEM WORK CONTROL S /RED/ 800 521 1130 POWER /GREEN/ 323 SOLENOID VALVE CORD POWER CORD UV LAMP CORDS MODEL AM15 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

21 ULTRAVIOLET WATER STERILIZER DWG# TITLE STERILIZER ORIENTATION DIAGRAM 7 1 2 4 3 7 6 5 10 8 9 11 MODEL AM1 PART AM1 AM2 AM3 AM4 AM5 AM6 AM8 AM10 AM12 AM15 1 STRAIN RELIEF 02.01 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 2 LAMP HOOD 01.02.02 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 3 MUFF 01.04.01 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 4 O-RING MUFF 01.03.01 2 pcs 4 pcs 6 pcs 8 pcs 10 pcs 12 pcs 14 pcs 20 pcs 24 pcs 32 pcs 5 WASHER 01.05 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 6 O-RING 01.06 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 7 SOCKET 01.08 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 8 UV LAMP 12.07 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 9 QUARTZ SLEEVE 12.09 1 pcs 2 pcs 3 pcs 4 pcs 5 pcs 6 pcs 7 pcs 10 pcs 12 pcs 16 pcs 10 CENTERING RING 01.15 2 pcs 4 pcs 6 pcs 8 pcs 10 pcs 12 pcs 14 pcs 20 pcs 24 pcs 32 pcs 11 DRAIN VALVE 01.12 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs 1 pcs Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

22 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413

23 Białostoczek 26,gm.Zabłudów,15-592 Białystok; Poland ; Tel. +48 857431246; VAT PL5420008413