Air Micron, a 5 year old venture, in the field of integrated micro contamination control, specializes in:

Similar documents
CLEAN AIR SYSTEM.

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)


CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Double Skin Air Handling Units

PRODUCT LINE ULTRAFIL AIR SYSTEMS First... In Clean Air CLEAN AIR PRODUCTS LAMINAR AIR FLOW WORK STATION: (Vertical and Horizontal) Construction made

Double Skin Air Handling Units

Cleanroom Air Showers

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

BioSafety Cabinet- Class 100

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Your Best Partner for

Aero Biotechniques.

We change the climate and Air pressure COMPLETE CLEAN ROOM SOLUTIONS IN SINGLE WINDOW SERVICE PROVIDER.


Double Skin Casing Air Handling Units

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

EHH SERIES DRAW THROUGH FAN COILS CFM

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Our energy efficient experts and engineers have made ground breaking innovations in this field.

CENTRIFUGAL BLOWERS & FANS TM MITTAL ENGINEERING

Classic Series AIR HANDLING UNIT. Range 1000 CFM to CFM 472 L/s to 9440 L/s

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Laminar Flow Cabinets eco air V

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

OIL SKIMMERS. Engineering Technologies

A MARKET LEADER IN TURNKEY INTERIOR FIT-OUT BUSINESS

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

the Innovative Solutions

1.1 This section applies to air handling units for HVAC Systems.

L a b o r a t o r y E q u i p m e n t C a t a l o g

AES Environmental. Operation and maintenance manual. VWS Series. Laminar Vertical Flow clean work station

TYPICAL CPA SPECIFICATIONS

Complete Solution for Painting & Baking

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Innovation in air purification unmatched air quality

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

AIR SHOWERS CAP701 SERIES

LAMINAR FLOW FOR ALL YOUR NEEDS

Air Shower with Integrated Air Handling Unit

CIRCULAIRE LAMINAR AIR FLOW

AIR HANDLING UNITS. Revision AG 16-07

Indoor Air Quality. For assured. Double Skin Air Handling Units

Double Skin Air Handling Units

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Microbiological Safety Cabinets

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

OPERATION AND MAINTENANCE MANUAL

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

AIR HANDLING UNIT AWAL GULF AIR CONDITIONING & REFRIGERATION PVT. LTD.

M Series Fan Filter Units

ENVAIR lab CO2 Incubator

39G Air Handling Unit

Laminar Flow Hoods and Booths

MINI BENCH TOP CHAMBER MODEL: MI-80-A-H

HALCO PRODUCTS COMPANY

MCB SERIES. cross ventilation cartridge dust collector

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

KIC Air Curtains. Technical Guide

Clean. Easy. COMPLIANT.

Guidelines for Ideal Layout for an Operating Theater Complex. Dr.R.D.Ravindran Aravind Eye Hospital Madurai

Air Handling Units. Real HVACR people who understand your needs.

Supplying Clean Air to Industry

Pharmaceutical Facility Design

Gelaire BH-EN and UltraSafe cabinets

An ISO 9001:2015 & GMP Certified Organization

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

AFD Industrial Dehumidifier Series

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

DIVISION 15 MECHANICAL

FagronLab NP-1 UV. Negative pressure workbench. User Manual

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

YMA Custom Air Handling Units

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

DRYAIR Turnkey Dry Room Standards

Cleveland Clinic Design Standards MECHANICAL SYSTEMS DESIGN GUIDELINES HVAC AIR DISTRIBUTION PART I - GENERAL 1.1 SUMMARY

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

Pvt. Ltd. We are eminent manufacturers, suppliers, traders and wholesalers of False Ceiling & Designing Services

SECTION AIR DUCT ACCESSORIES

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Transcription:

1) About us : AIR MICRON CLEANTECH is one of the leading Pre-engineered, Prefabricated Air Handling Unit, Ventilation and clean room equipment manufacturer in India. AIR MICRON CLEANTECH has an expert team of Engineers, Pharmaceutical Experts and Technicians who bring their core competence to the table, to accomplish a task from start to finish. AIR MICRON CLEANTECH has a pool of technical experts who have worked with many leading national and multinational corporations thus creating a rich and varied team of Pharmaceutical Engineers. Air Micron, a 5 year old venture, in the field of integrated micro contamination control, specializes in: AHU (Air Handling Unit) & Ventilation Systems Facility Engineering Clean rooms and Biosafe environs Modular Clean rooms comprising Movable Walls Panels, Ceilings, Doors, Covings etc. Laminar Air Flow systems and other HEPA filter Devices Air Showers, Garment Storage Cubicles and other Cleanroom Accessories HEPA & other Air filters. Consistent quality control starting at the receipt of goods, followed by repeated checks in the individual attention, right up to the constant top quality of our fabrication work 2) Profile : Air Micron Cleantech is a leading specialist contractor in the design, construction, and certification and fit-out of Clean, Sterile and Containment environments in India. Through our specialist knowledge of these sectors and our many years of experience, we work with customers to provide dynamic, standard or tailor made solutions. We are dedicated to providing cost effective and innovative problem solving alternatives on time and within budget to comply with the strict statutory / regulatory regulations of health and safety, cleanliness and hygiene of our target market sectors. i) Design : Air Micron Cleantech through its well established Engineering department has enabled the company to take clean room / containment design to a higher level with the ability to produce detailed three dimensional modeling and with building services software design / selection packages to aid the decision making process at the design - development stage. Air Micron Cleantech has developed innovative clean room designs to cater for the dynamic needs of our customers. We offer a range of cost effective and state of the art clean rooms which has enabled us to become a leader in the industry. 3) Products : - (A) HVAC PRODUCT & (B) CLEANROOM PRODUCTS

(A) HVAC (heating, ventilation & air conditioning) Products i) Air Handling Unit & Ventilation Air Micron Cleantech is leading manufacturer of Clean Room and Air-conditioning Equipments. Air Micron offer double Skin and single Skin Air Handling units that are developed and power with innovative technology to provide customer satisfaction. Air Micron are also design and execution of central air conditioning for Pharma company, cleanroom, hospital,call centre, shopping mall, office building, hotel,school,r& D centre and many more. Type Horizontal /Vertical /Ceiling Suspended Double/Single Skin/Double Decker Capacity Static Pressure MOC Outer Skin Panel Thickness Infill Between Panel Frame Work Base Frame Coil Drain Motor Fan Filters 400 CFM to 50000 CFM 25 mm to 150 mm of Wg Inner Skin-.6 mm Thick Pre coated 0.6 MM thick GI Plain 25 mm and 50 mm thick Sandwitch construction with CFC Free PUF Insulation Extruded aluminium profile with nylon fitting GSS Frame 4 / 6 / 8 / 2 Row Copper Tube with aluminium fins Aluminium/SS/GI Crompton, ABB/siemens Make 3 Phase Motor Forward and Backward Fan imported Fan 50 M thck pre filter/300mm fine and HEPA filter

ii) Terminal Filter Box Terminal Boxes are normally used as boxes for flange type HEPA Filter made from s.w.g 16 gauge C.R.C.A sheets for overall construction with epoxy powder coated finish. Housing Box for HEPA Filter is complete with: 1. Inside M.S. angle frames duly epoxy powder coated 2. Hold fast (grounding arrangement/ceiling suspension angles) 3. Fixing and tightening S.S bolts 4. Flexible canvas connection for twoside Aluminum flange 5. Perforated Aluminum sheets, duly epoxy powder coated and S.S fixing screws

iii) Return Air Riser Air Riser is extensively applied to overall appearances of cleaned rooms. Through strong manufacturing capabilities, we are able to provide Customized Return Air Riser as per the specifications of clients. Construction : Riser is made up of stainless steel, analyzed, aluminium, GI, powder coated steel and double skin. Riser come with aluminium and SS perforated sheet along with filters and dampers. iv) Ducting Basically, ducting or piping system needs to be insulated for two major reasons. One is to avoid condensation on the surface, another one is to control the stability of the temperature during transportation inside the system. Ducting is made up of stainless steel, analyzed, aluminium, GI, pre coated sheets

(B) CLEANROOM Products i) Dynamic Pass Box /PASS BOX DESCRIPTION : It is used for transfer of material from one area to another with isolation by means of Mechanical / Electromagnetic door interlocking, which ensures opening of only one door at a time. Thus avoiding cross contamination between two area's. CONSTRUCTION : These units are factory assembled and are made up of S. S. 304 grade Stainless Steel material. These units have smooth welded corners. INSTALLATION : Pass-Through Chambers can be installed in a number of ways, depending on the wall or door that will support them. General Specification of the Dynamic Pass Box: MOC Pre-filter Final Supply Filter Motor Blower Assembly Differential Pressure Gauge SS 304, SS316. Air Micron Make EU 4 rating with suitable size having efficiency 90% down to 10 micron. HEPA Filter having EU 13 or EU14 rating with suitable size having efficiency 99.997& down to 0.3 micron. Statically & Dynamically balanced with suitable rating and size. (Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise. (make : Dwyer, USA) (To measure differential pressure across the supply HEPA

filter Lights CFL Light Through Clear Acrylic to Get Maximum Illumination / Hour Meter with UV Light. Door Interlocking Electro Magnetic Interlocking Air Cleanliness Class ISO 5 (as per ISO 14644-1). Air Flow Rate 0.45 + 0.1m/sec. Vibration Level Minimum General Specification of the Static Pass Box MOC SS 304, SS 316 Doors Sandwiched Door with double sided View Panel, Handles Door Interlocking Electro Magnetic Interlocking Coving Inner Side Bottom Corners will be Duly Coved. Protective Light UV light with hour meter. Air Micron Cleantech Clean room Pass Box with Laminar Air Flow Model Bioclean storage space dimensions Overall dimensions w d h W D H 2610-SP-LF 1220 1220 1220 1470 1370 2000 2610-SP-LF-1 910 610 910 1100 680 1560 2610-SP-LF-2 610 610 610 790 680 1260 ii) AIR SHOWER Air Showers are to be used for removing surface particles from personnel prior to entering a Cleanroom work area. Features: HEPA filter eff. 99.97% down to 0.3 micron Pre filter eff. 85-95% Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7" x 4½" to produce 6000 FPM high velocity Electrical supply 3 phase, 440 volt, 50Hz Total 16 nozzles provided for single person entry level Hinge type door with glass window. Hydraulic door closer

iii) Dispensing / Sampling Booth Equipment is used for dispensing of powder & chemicals to minimize the risk of contaminating of the work area & ensures the health for working person under the laminar air flow. The equipment is based on 3 level of filtrations of air circulation. This ensures that the cloud or particles formed by the material dispensed is sucked form the pre filter, intermediate filter & supply with mini pleat HEPA filter. Magnehelic gauge will indicate the pressure difference between the filters. During the initial cycle we achieve class 100 air with velocity 0.45m/s +/- 20% below working area. Features: Class 100 air Air curtain PVC curtains is provided Internal coving is provided DOP port up stream is provided Mini pleat HEPA filter eff. 99.997% down to 0.3 micron as a supply filter Pre filter eff. 95% Intermediate filter efficiency 90% Motor blower assly : High capacity, FRP blower with aluminum impeller dia 7 * 4 ½ Electrical supply 3 phase, 440 volt, 50Hz Velocity 90 +/-20% below working area iv) Horizontal Laminar Flow The application of these laminar air flow module is varies and takes place in the industrial manufacturing for the protection of the product in the following areas. Pharmaceutical micro-biology, food, electrical, cosmetic industry Filling sections, Assembling processes, Tissue culture The unit is ideal to protect the product from particular contamination with the help of class 100 air & UV tube. Items Description MOC SS304, 316, GI powder coated Pre-Filter Air Micron Make EU 4 rating with suitable size having efficiency 90% down to 10 micron.

Final Hepa Filter HEPA Filter having EU 13 or EU14 rating with suitable size having efficiency 99.997& down to 0.3 micron. Motor Blower Assembly Statically & Dynamically balanced with suitable rating and size. (Induction motor with centrifugal blower) A Mounting unique spring suspension system to take care of vibration and noise. Mounting Unique Spring Suspension Systems to take care of Vibration and Noise Working Table S.S. 304 with Due Reinforcement for Better Performance and Stability. Side Panel Accessory Glass Side Panels Pressure Gauge DWYER, USA Minihelic Differential Pressure Gauge : 01 No Air Cleanliness Class ISO - 5 (as per ISO - 14644-1). Air Flow Rate 0.45 ± 0.05mps. Vibration Level Minimum On-off Switch Feather Touch on off Switch for blower-motor, Lamp & UV lamp etc. Model of the Horizontal Laminar Air Flow clean air work station as following: HORIZONTAL LAMINAR FLOW CLEAN AIR WORKSTATIONS Model Work space dimensions Overall dimensions w d h W D H 2202 610 610 610 710 1070 1450 2203 910 610 610 1015 1070 1450 2204 1220 610 610 1320 1070 1450 2206 1830 610 610 1930 1070 1450 v) Ceiling Suspended Laminar Flow Ceiling suspended laminar air flow (claf) are used for ot applications, pharma filling & packing line etc. Claf provides ultra clean sterile hepa filtered class 100 air in a isolated area where the highly sensitive process activities are carriedout. Claf available in complete stainless steel construction or gi construction with pu coated finish. Equipped with minipleat hepa with dynamically balanced ultra-low noise blowers for optimum airflow.

vi) Operation Theater Modular OT is a finished steel structure with joint less sterile coating providing a high quality finish. Pre-fabricated modular OT offer the advantage of speedy construction, high quality finish in prevention of contamination build up, long durability, robust and flexibility design for future expansion, ease of maintenance etc. The pre-engineered modular Operation Theatre solves the problem of infections. We provide following products for completion of O.T. 1) Volume Control Dampers 2) Minipleat Hepa Filters of efficiency 99.997%

4) Our Clients : We pledge to live up to your expectations. Client Name Ar-ex Laboratories Pvt Ltd (Mumbai) Olive Soft Gel (Deharadun) Kopran Ltd (Mahad-Raigad) Lyok Laboratories (Andheri) Bittu Pharmaceuticals (Vasai) Arco Pharmaceutical Ltd (Vasai) Remadies Pharmaceutical Ltd (Vasai) Inor Medical Product Ltd (Mumbai) Coral laboratories Pvt Ltd (Deharadun) Scientific Pharmacy (Andheri) Sevil Pharmaceutical Ltd. (Mumbai) Olive Health Care (Daman) Sanjivani Parentrile Ltd (Rabale) Vital Health Care Pvt Ltd. (Nashik) Magna Laboratories Pvt ltd. (Vapi). MEDISYNTH CHEMICALS PVT LTD (Turbhe) Badrivishal Chemical & Pharmaceutical On Top Pharmaceutical Pvt Ltd (Banglore) Iatro Pharma & Biotech Ltd (Pune) Nem Laboratories Pvt ltd. (Vasai) K M Hospital (Mumbai) Omega products Pvt ltd. (Mhape-Navi Mumbai) Metagraph Ltd (Pune). BARC (Bhabha Atomic research Center- Vashi- Navi Mumbai) Harkishandas Hospital (Mumbai) Johnson & Johnson Dortmund Pharmaceutical Pvt Ltd. Shreechem Pharmaceutical Pvt Ltd. Advance Enzyme (Sinner) Pennwalt Ltd- Nerul Watson Pharma Pvt Ltd Ambernath Nanawati Hospital Mumbai. Bioxera Pharma Ambernath Hope Hospital (Pune) Nature Of work Clean Room Equipment HVAC & Turnkey, Clean room System HVAC & HVAC & Clean room HVAC & Clean room System HVAC & Turnkey, Clean room System AHU HVAC & Clean room HVAC & clean room AHU AHU & HVAC AHU & FDV System Fume Hood AHU & OT Module HVAC & Clean room System AHU & Ventilation. AHU & HVAC System HVAC AHU, HVAC & OT System AHU & HVAC System

Mfg. of HVAC system & solution, Clean Room Equipment, Etc. Corp. off.: Plot no X-18/8, Subodhi Commercial complex, MIDC Residential Zone, Mamta Hospital Road, Dombivali (E).-421203, Tel.: 0251-2800047 Email Id- airmicron@rediffmail.com Website: www.airmicron.com www.indiamart.com/airmicroncleantech http://www.airmicroncleantech.tradeindia.com Factory Add.1: Unit No- 6, Vasant Patil Compund-2, Sonarpada, Kalyan Shill Road, Dombivali (E)-421204. Factory Add.2: Unit No-5/11, Roop nawal Indl Est, Near Vidyavikasini School Road, Fatherwadi, Vasai Road (E). Dist- Thane.