MEAT AREA DAIRY AREA
PLUMBING SCOPE OF WORK - WATER KEC TO PROVIDE: - ALL FAUCETS, AS REFLECTED ON EQUIPMENT SCHEDULE, - WATER CONNECTION FROM ICE MACHINE FILTER TO ICE MACHINE. PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL FIXTURES PROVIDED BY KEC, - FINAL CONNECTIONS FOR DISHWASHER, - 1 2 " SHUT OFF VALVE FROM STUB OUT TO ALL WATER FILTERS REFLECTED ON THIS PLAN, - NECESSARY BACK FLOW EQUIPMENT AT SODA EQUIPMENT AS PER CODE, - NECESSARY BACK FLOW EQUIPMENT FOR ICE MACHINE IF REQUIRED BY CODE. VENDOR TRADES: - FINAL CONNECTION FROM FILTER TO PROVIDED EQUIPMENT. PLUMBING SCOPE OF WORK - DRAINS KEC TO PROVIDE: - ALL TWIST WASTE VALVES & BASKET DRAINS, AS REFLECTED ON EQUIPMENT SCHEDULE, - INSTALLATION OF PVC DRAINS FOR ICE MACHINE AND ICE BIN WITH NECESSARY AIR VENT AS PER CODE, - PIPE CONDENSATE DRAIN FOR WALK IN COOLER WITH 3/4" COPPER TUBING, WITH NECESSARY "P" TRAPS AS PER CODE, - PIPE CONDENSATE DRAIN FOR WALK IN FREEZER WITH 3/4" COPPER TUBING, WITH NECESSARY "P" TRAPS AS PER CODE, PROVIDE INSULATION AND HEAT TAPE IN ALL FREEZER AREAS. PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL NECESSARY DRAINAGE PIPING WITH PVC OR COPPER (AS REQUIRED) PIPE, AS REFLECTED ON THIS ROUGH IN PLAN FOR ALL SINKS AND EQUIPMENT, - INDIRECT DRAINS REQUIRE 1 1 2" AIR GAP ABOVE FLOOR SINK, - ANCHOR ALL INDIRECT PIPING WITH UNISTRUT AND STRAPS FOR CLEAN FINISH
PLUMBING CONTRACTOR ANSUL VALVE TO BE INSTALLED ON GAS LINE, ABOVE GRID PLUMBING CONTRACTOR RUN MAIN GAS LINE ABOVE WALL, PROVIDE 1" DROPS TO EACH STUB OUT LOCATION PLUMBING SCOPE OF WORK - GAS NOTES KEC TO PROVIDE: - QUICK DISCONNECT GAS HOSE KITS, 3 4" X 48" FOR EACH PIECE OF GAS EQUIPMENT AS NOTED ON EQUIPMENT SCHEDULE, - SOLENOID VALVE FOR MAIN GAS LINE SHUT OFF (PART OF THE ANSUL SYSTEM). PLUMBING CONTRACTOR TO PROVIDE: - INSTALLATION OF ALL QUICK DISCONNECT GAS HOSES & SAFETY CABLES AS SHOW IN THE DETAIL ABOVE, - INSTALLATION OF SOLENOID VALVE FOR MAIN GAS LINE IN LOCATION DETAILED BY PLUMBING ENGINEER ON GAS LINE SCHEMATIC. - APPROPRIATE GAS PSI/W.C. TO ALL NECESSARY EQUIPMENT, PER SPEC SHEETS PROVIDED ELECTRICAL CONTRACTOR TO PROVIDE: - WIRING FROM SOLENOID VALVE TO ELECTRICAL CONTROLS OF HOOD SYSTEM.
1 2 CORD FROM CEILING FOR UTILITY OUTLET AT PREP TABLE CORD FROM CEILING FOR UTILITY OUTLET AT PREP TABLE 3 ELECTRICAL SCOPE OF WORK ELECTRICAL CONTRACTOR NOTES: 1) PROVIDE DIRECT SHUNT TRIP BREAKER FOR WALK IN FREEZER DOOR HEAT STRIP (BY KEC/WALK IN MANUFACTURER) AND DRAIN LINE HEATER (BY KEC) - WIRE TIME CLOCK IF SHIPPED LOOSE, 2) PROVIDE DISCONNECT SWITCH FOR EACH WALK IN CONDENSER WITHIN 6 FEET PER CODE, 3) WIRE EXHAUST FANS, MAKE UP AIR UNITS AND ALL DESIGNATED OUTLETS UNDER HOOD SYSTEMS INTO ELECTRICAL CONTROL PANEL (KEC PROVIDED). GENERAL NOTES: - PROVIDE GFI OUTLETS IN ALL AREAS OF THE KITCHEN, - DIRECT CONNECTIONS REQUIRED ARE TO BE WATERTIGHT CONDUIT
WALK IN COOLER/FREEZER REMOTE CONDENSER LINES, CONFIRM RUN IN FIELD CONDENSERS FOR WALK IN COOLER/FREEZER LOCATED IN BACK DOCK AREA ON FREE STANDING RACK - SEE DETAIL ANSUL PULL STATION LOCATION MECHANICAL ENGINEER NO AC REGISTERS WITHIN THIS PERIMETER 4 3 2 1 1 2 3 MECHANICAL ENGINEER NO AC REGISTERS WITHIN THIS PERIMETER MAIN HOOD ELECTRICAL CONTROL LOCATION ANSUL PULL STATION LOCATION MECHANICAL SCOPE OF WORK KEC TO PROVIDE: - RECEIVING OF EQUIPMENT DELIVERY ONSITE, - HOOD BOXES, - 20 GA. S/S WALL FLASHING UP TO 120" HIGH (CONFIRM WITH GC CODE REQUIREMENT ON HEIGHT) FROM 4"ABOVE FLOOR, END OF HOOD TO END OF HOOD AND ANY SIDE WALL(S) AROUND PERIMETER OF HOOD, - EXHAUST FAN(S) & ROOF CURB(S), - EVAP COOLER/MAKE UP AIR UNIT & ROOF CURB(S), - ELECTRICAL CONTROL PANEL W/ RELAYS & CONTACTORS, - ANSUL SYSTEM PIPING, TANKS, PERMIT, INSTALLATION & FINAL TEST, - HANGING OF HOOD BOXES & INSTALLATION OF S/S WALL FLASHING, - PERFORMANCE CHECK OF SYSTEM AFTER HVAC START UP, - LOCATIONS FOR ROOF PENETRATIONS FOR REMOTE CONDENSERS WITH PVC CHASE, - PRESSURE TREATED 4"X4" WOOD FOR SETTING OF REMOTE CONDENSERS WHEN NECESSARY. GC/MECHANICAL CONTRACTOR TO PROVIDE: - RECEIVING OF ROOFTOP EQUIPMENT ONSITE, ONSITE STORAGE IF NECESSARY, - CRANE TO ROOFTOP, - CUTTING OF ROOF DECK & PLACEMENT OF CURBS, PATCHING OF ROOF, - GREASE DUCT/FIREWRAP & INSTALLATION, - MUA/AC DUCT & INSTALLATION, - MOUNTING OF ELECTRICAL CONTROLS (IF NECESSARY), - FINAL ELECTRICAL & PLUMBING CONNECTIONS, - START UP AND BALANCE OF HOOD WITH AC, - CUTTING AND SEAL ROOF PENETRATIONS FOR REMOTE CONDENSER LINE CHASE - PROVIDE GALVANIZED "GOOSE NECK" IF PREFERRED OVER KEC PROVIDED PVC. - CONDENSER CURBS SHOULD THEY BE REQUIRED OVER 4"X4" WOOD BY KEC. MECHANICAL NOTES: 1) EXHAUST DUCT RISER CONNECTION POINT 2) MAKE UP AIR/EVAP COOLER RISER CONNECTION POINT 3) AC DUCT RISER CONNECTION POINT 4) WATER HEATER VENT FLUE, DETAILS BY PLUMBING ENGINEER
REVISIONS Arizona Office www.captiveaire.com 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
REVISIONS Arizona Office www.captiveaire.com 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
REVISIONS www.captiveaire.com Arizona Office 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
REVISIONS Field Wired and Piped From building water supply Roof line B Normally closed valve PRESSURE SWITCH B R OVERFLOW SWITCH W R W Normally open valve To building drain A1 15 E P TIMER A A2 16 18 Internal Water Solenoid www.captiveaire.com Arizona Office 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
REVISIONS Arizona Office www.captiveaire.com 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: Room Temperature Sensor -Wall mounted under HVAC Thermostat or at least 10' away from hood. MASTER DRAWING SHEET NO.
REVISIONS AIR FLOW AIR FLOW Arizona Office www.captiveaire.com 1717 E. Bell Road, SUITE 12, Phoenix, AZ, 85022 PHONE: (480) 926-6810 FAX: (877) 719-2227 EMAIL: reg93@captiveaire.com DATE: DWG.#: DRAWN BY: SCALE: MASTER DRAWING SHEET NO.
200 207 210 214 218 203 206 210 215 217 220 201 209 213 202 204 205 211 216 219 221 208 212 SS1 SS1 SS1 SS1 304 309 A SS3 302 304 309 311 301 306 305 308 312 313 300 303 314 SS1 D SS5 400 E 401 402 307 403 406 406 404 404 403 402 401 201 412 413 414 SS4 SS4 405 SS1
WALK - IN SPECIFICATIONS U} L Outdoor Walk-in Cooler/Freezer Combo OVERALL SIZE: 7'-9" X 14'-6" X 8'-6 1/4" A089369R1 001 N/A DRAWING #: UNIT #: ORDER #: 7'-9" PANELS FOAMED IN PLACE URETHANE FOAM 4" 7'-1" EXTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA FLOOR: GALVALUME - EMBOSSED 26 GA INTERIOR FINISH WALL: GALVALUME - EMBOSSED 26 GA TOP: GALVALUME - EMBOSSED 26 GA FLOOR TYPE F01 FREEZER : ALUMINUM - SMOOTH ALUMINUM.100 C01 COOLER : SCREED, METAL 4" HIGH WALK-IN ACCESSORIES (2) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) LOT, ROOF CAP - SLOPED MEMBRANE FLASHED (SLOPE 1/4" PER FOOT) (1) LOT, TAPCON FASTENERS (1) LOT, RACKING CLIP (1) LOT, TIE DOWN ANGLE - 1/4" X 3" X 4" X 96" (W-IN CL TO BUILDING) (30) LF, COVE BASE, GALVALUME EMBOSSED 26 GA 1.25 X 4.25 F01 - FREEZER : W/FLOOR 8' - 6 1/4" O.A. HEIGHT 7' - 10 5/8" I.D. 15" 25 3 34 8 " 1 4 " 253 8 " 5'-3 1 2 " Kolpak TM 2915 Tennessee Avenue North, Parsons, TN 38363 (731) 847-6361*(800) 826-7036* A Manitowoc Company REFRIGERATION PC199LOP-2 VOLTS: 208-230-60-1,BTU:5845 EL24-72-2EC-PR-4 VOLTS: 208-230-60-1,BTU:7200 TEMP: WALK-IN -10,AMBIENT TEMP: 115 (1) RACK 1 TIER B LINE RDI 461 46 2 " 1 2 " 14'-6" 1 PC99MOP-2 VOLTS: 208-230-60-1,BTU:7799 AM26-87-1EC-PR-4 VOLTS: 115-60-1,BTU:8700 TEMP: WALK-IN 35,AMBIENT TEMP: 115 (1) RACK 1 TIER B LINE RDI C01 - COOLER : NO FLOOR 8' - 6 1/4" O.A. HEIGHT 8' - 2 1/4" I.D. 25 3 8 " A 34 1 4 " 253 8 " 15" 8'-2 1 2 " 8'-4 1 2 " CENTER TO END NOTE: DOOR JAMB EXTENDS DOWN PAST SCREEDS TO FLOOR. 2 TEMPLE BETH TEFILLAH D10 N/A SCOTTSDALE,AZ 85250 USA! ATTENTION FOR APPROVAL SPACE DESIGNATED 1. DRAWING NOT INTENDED FOR INSTALLATION - DESIGN APPLICATION ONLY. 2. ALL WALK-INS ARE DESIGNED FOR INDOOR APPLICATION UNLESS NOTED OTHERWISE 3. PENETRATIONS AND SEALING OF ARE THE RESPONSIBILITY OF OTHERS 4. ALLOW 2" MINIMUM CLEARANCE WITH AIRFLOW OF 5 CFM PER 100 SQ FT AROUND ENTIRE PANEL SURFACES 5. GENERAL CONTRACTOR TO REFER TO DESIGN AND SPECIFICATION MANUAL FOR FLOOR DETAIL INFORMATION 6. QUARRY TILE OR CONCRETE FLOOR APPLICATIONS: METAL PANEL FACING MAY BE SUSCEPTIBLE TO STAINING DUE TO EXCESSIVE MOISTURE CREATED BY THE HYDRATION OF CONCRETE TYPE MATERIALS. IT IS ABSOLUTELY NECESSARY THAT EACH ROOM BE PROPERLY VENTILATED. SPECIAL PRECAUTIONS MUST ALSO BE TAKEN WHEN USING MURIATIC ACID DUE TO EFFECTS HYDROCHLORIC FUMES HAVE ON METAL MATERIALS 7. PANEL LAYOUT MAY CHANGE BASED ON OPTIMAL MANUFACTURING STANDARDS 8. WALK-IN TOP IS NOT DESIGNED FOR FOOT TRAFFIC OR STORAGE UNLESS NOTED OTHERWISE 9. IF CONDENSING UNIT IS LOCATED IN THE INTERIOR OF BUILDING A MINIMUM OF 24" OF CLEARANCE IS REQUIRED AROUND TOP AND SIDES 10. FLOOR, CURB, AND PIT DETAILS ARE FOR GENERAL REFERENCE ONLY. THESE DRAWINGS SHOULD NOT BE USED OR INCORPORATED IN THE DESIGN OR PREPARATION OF THE INSULATED FLOOR, SUB-SLAB OR CURBS, WITHOUT HAVING THE DESIGN REVIEWED BY A QUALIFIED ENGINEER. ALL FOOTINGS, FOUNDATION WALLS AND CONCRETE WEAR SLABS ARE THE RESPONSIBILITY OF THE BUILDING ENGINEER OR ARCHITECT. 11. THE FOAM PLASTIC USED IN THIS PRODUCT COMPLIES TO THE IBC SECTION 2603 AS FOLLOWS: FLAME SPREAD RATING: 20; SMOKE DEVELOPED RATING: 450; FLASH IGNITION TEMPERATURE RATING: 915 f; SPONTANEOUS IGNITION TEMPERATURE RATING: 950 f. 46 1 2 " B 46" X 84" MIN. MASONRY OPENING WALLS LAYOUT 46 1 2 " YOU MUST REVIEW ALL NOTES, DETAILS, DIMENSIONS, FINISHES, DOORS SIZES, LOCATIONS AND SWINGS APPROVAL- NO CHANGE REQUIRED, MANUFACTURE AS DRAWN. APPROVED AS NOTED- MAKE REQUIRED CHANGES AND MANUFACTURE AS DRAWN. NOT APPROVED- DESIGN CHANGES REQUIRE DRAWING REVISION AND RESUBMISSION. DATE: BY: TOPS LAYOUT SMOOTH FINISH DISCLAIMER Panels with non-textured and/or no-profile panel finishes (smooth finishes) on the exterior and interior faces may exhibit oil canning" and flatness imperfections on the surface. Our standard panels have a stucco embossed texture on both faces that helps to reduce oil canning and any other irregularities in the exposed surface. Please be aware of this potential situation in your specification process. Such oil canning and flatness issues are typical and are not covered under standard warranties. 23 1 2 " 46" 231 2 " 7'-5" CENTER TO CENTER FLOORS LAYOUT FOR ENGINEERS SEAL DRAWN BY: DATE: CHECK BY: DATE: QUOTE REVISION DATE: JTT 11-1-16 DWP 11-1-16 SHEET # AD-1 of 2
3'-4 3 4 " 3'-9 1 2 " FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (STD) (1) THERMOMETER - 2 INCH DIAL W/6' LEAD (STD) (1) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) VENT - PRESSURE RELIEF, HEATED KASON 1825 (STD) (1) CENTER DOOR SECTION LIGHT OVER DOOR (3) HINGE - KASON 1345 ADJUSTABLE / SPRING ASSISTED (STD) (1) HANDLE - KASON 28 WITH LOCKING ASSEMBLY (STD) (1) DOOR CLOSER - KASON 1098 W/COVER AND HOOK (STD) (1) HEATER WIRE, 2.5 WATT / FT (1) THRESHOLD, STAINLESS STEEL 14 GA (1) RAMP INTERIOR 34X20 4'-1 1 2 " 3'-8 3 4 " FRAME: RECESSED 0" WITH 0" LEVELING SAND AND 0" TILE AND GROUT EXT: GALVALUME - EMBOSSED 26 GA INT: GALVALUME - EMBOSSED 26 GA PLUG: EXT: GALVALUME - EMBOSSED 26 GA EXT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH INT: GALVALUME - EMBOSSED 26 GA INT: KICKPLATE, ALUM.063 DIAMOND TREAD 36" HIGH HARDWARE AND ACCESSORIES: (1) SWITCH - PILOT LIGHT INCLUDED UL (STD) (1) THERMOMETER - 2 INCH DIAL W/6' LEAD (STD) (1) LIGHT FIXTURE - KASON 1803LED W/BULB AND GLOBE (STD) (1) CENTER DOOR SECTION LIGHT OVER DOOR (3) HINGE - KASON 1345 ADJUSTABLE / SPRING ASSISTED (STD) (1) HANDLE - KASON 28 WITH LOCKING ASSEMBLY (STD) (1) DOOR CLOSER - KASON 1098 W/COVER AND HOOK (STD) ADJACENT BUILDING WALL 1/4" x 1-3/4" TAPCON ANCHOR HEX WASHER HEAD; USE 3/16" x 4-1/2" CONCRETE DRILL, TAPCON BIT #790-1018 OR EQUAL (28931-1075) TAPCONS ARE 9" O.C. WITH MIN 1-1/4" EMBEDMENT. FLASHED ROOFCAP TRIM L3" x 4" x 1/4" 6063-T6 PAINTED ALUMINUM ANGLE (28925-1090) SILICONE BEADS MEMBRANE ROOF SLOPED INSULATION A089369R1 001 N/A DRAWING #: UNIT #: ORDER #: DW-1 A DW-2 B 1/4" x #14 x 2" HEX WASHER HEAD TEK SCREW (279161075) (6" ON CENTER) Kolpak 2915 Tennessee Avenue North, Parsons, TN 38363 (731) 847-6361*(800) 826-7036* A Manitowoc Company TM 8 DETAIL - TIE DOWN ANGLE-WALK IN CLTO BUILDING-OUTDOOR TRIM ANGLE TRIM ANGLE (FLASHED) ROOF MEMBRANE 4" 1 COMPARTMENT DESCRIPTION TEMP F WI QTY MODEL# DIMENSIONS COMPRESSOR TYPE L (A) W (B) H (C) LBS HP CONDENSING UNIT RLA COMPRESSOR LRA V HZ Ф CONDENSER FAN MTR CONNECTIONS O.D. RCV CAP TOTAL MX AMP FLA V Ф AMPS DISC SUCT LIQ @ 90% FULL (lbs) Freezer -10 1 PC199LOP-2 Hermetic 33 25.5 19.25 186 2 16.7 87 208-230 60 1 1.1 208-230 1 18.1 35 7/8 3/8 10.2 Cooler 35 1 PC99MOP-2 Hermetic 33 25.5 19.25 156 1 6 43 208-230 60 1 1.1 208-230 1 7.2 15 5/8 3/8 10.4 COMPARTMENT DESCRIPTION Freezer Cooler DOOR DETAIL - 4IN FLOOR-RAMP SWEEP GASKET HEATER WIRE BOTTOM PLATE S/S THRESHOLD FLOOR PANEL TEMP F WI QTY 2 DOOR DETAIL - FLAT BOTTOM SWEEP GASKET FLAT BOTTOM WALL FINISHED FLOOR MODEL # DIMENSIONS (DEFROST: A-AIR E-ELECTRIC) L (D) W (E) H (F) LBS 3 FLOOR OR METAL SCREED UNIT COOLER AMP FAN V IF REQUIRED, PLACE LEVELING SHIMS AT EACH SCREW LOCATION TO MAINTAIN A LEVEL FLOOR. AMP HEATER 1/4" x 4" TAPCON ANCHOR, PHILLIPS FLAT HEAD. USE 3/16" x 6-1/2" CONCRETE DRILL BIT #790-1026 OR EQUAL; DRILL THRU HOLE. V Ф SUCT CONNECTIONS O.D. -10 1 EL24-72-2EC-PR-4 37 15 15.25 67 0.9 208-230 8.7 208-230 1 7/8 3/8 3/4 35 1 AM26-87-1EC-PR-4 41.5 15 15.25 67 1.8 115 0 N/A 0 7/8 3/8 3/4 LATCH STRIKE DETAIL - PANEL CONNECTION AT FLOORS OR METAL SCREEDS 4 WALL PANEL FINISH FLOOR FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR WITH FLOOR FLOOR PANEL 1-1/4" MIN LIQ IF REQUIRED, PLACE LEVELING SHIMS AT EACH SCREW LOCATION TO MAINTAIN A LEVEL FLOOR. 5 FINISH FLOOR FASTENER AT 11.5" ON CENTER DETAIL - TAPCON ANCHOR DRAIN 1/4" x 4" TAPCON ANCHOR, PHILLIPS FLAT HEAD. USE 3/16" x 6-1/2" CONCRETE DRILL BIT #790-1026 OR EQUAL (28930-1075); DRILL THRU HOLE. METAL SCREED ELECTRICAL CONNECTIONS (IN REAR) 1-1/4" MIN CONDENSING UNIT ASSEMBLY AIR INLET B D A LIQUID CONNECTION (IN REAR) SUCTION CONNECTION (IN REAR) C SUCTION AND LIQUID LINE EVAPORATOR - MODEL AM, EM, EL, AMB, ELB E MPT DRAIN SLOPED FOAM INSULATION SLOPE = 1/4" PER FT 7 6 F DETAIL - SLOPE MEM ROOF CAP FLASHED F M M F 18" CEILING PANEL WALL PANEL LOCKS STRIKES RACKING CLIPS DETAIL - RACKING CLIP FLOOR PANEL OR SCREED CLEARANCE REQUIREMENT MINIMUM CLEARANCE REQUIRED FOR PROPPER OPERATION SIDE VIEW 36" REQUIRED FOR SERVICING AIR FLOW TEMPLE BETH TEFILLAH D10 N/A SCOTTSDALE,AZ 85250 USA QUOTE REVISION DATE: DRAWN BY: DATE: CHECK BY: DATE: JTT 11-1-16 DWP SHEET # AD-2 of 2