Product Data Sheet 4114 N/17HH-218. The engineer's choice

Similar documents
SPECIFICATION FOR APPROVAL. Customer Description Part No.. Model No. JDD VBBA51(0A24) Sample Issue No. Sample Issue Date

SPECIFICATION FOR APPROVAL

TEMPORARY SPECIFICATION FOR REFERENCE

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

STANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

SPECIFICATION FOR APPROVAL

Operating instructions

研發處 研發處 研發處 研發處 簡文榮 林茂盛 AD0612LB-A73GL P.S. REV. DC FAN (RoHS) 研發處

MDA Series. DC Axial Flow Fans with Low-Speed Alarm. $$ The Low-Speed Alarm: "Features

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD1212PTS1-6A

INSTRUCTION & SERVICE MANUAL

Revised Record 研發處發行章 Rev. Revision Description Change page Date A00 Preliminary

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Temperature Controllers

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

COMPACT FLAME CONTROLLER CFC 2000

Retroreflective sensor with polarization filter

INSTRUCTION & SERVICE MANUAL

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Technical Data. Dimensions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Remote NAC Power Supply D7038

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

Solid State Relays SOLITRON MIDI Current Sensing Type RJCS, RJCSR

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

SPECIFICATION FOR APPROVAL PLEASE SEND ONE COPY OF THIS SPECIFICATION BACK AFTER YOU SIGNED APPROVAL FOR PRODUCTION PRE- ARRANGMENT.

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

ER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.

Danfoss gas detection units

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

USER GUIDE. RLH Auxiliary Fan Kit. Description. The leader in rugged fiber optic technology. ENCLOSURE TEMPERATURE CONTROL. RLH Industries, Inc.

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Long Life AC Axial Flow Fans MRE Series

COMPACT FLAME CONTROLLER CFC 1000

G Installation manual Solitude - dmev unit

SUNON SPECIFICATION FOR APPROVAL

DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

FIRERAY 5000 range USER GUIDE

DIESEL Engine Fire Pump Controllers Features

Emotron M10 Shaft Power Monitor. Instruction manual English

DMFPM-2R MULTIFUNCTIONAL

Analog Room Pressure Monitor RPC Series

SUNON SPECIFICATION FOR APPROVAL. ISSUE DATE Apple 12/28 REVISION DATE

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Datasheet: K-22 LO Sensor

PROTECT SRB 200EXi-1A

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

MODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

Class 1 laser beam sensor safe for your eyes

R1000 / R1040 / R1080

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Danfoss gas detection units

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Technical Data. General specifications. Rated operating distance s n 5 mm

Class 1 laser beam sensor safe for your eyes

Protection Chain IQ-Sensor + Relaiy device T420

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

QTi DALI 2X21/39 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

Soft Starter Centrifugal Pump Soft Starter Series

Retroreflective sensor with polarization filter

Heating Element. Building Technologies HVAC Products

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

PRODUCT DATASHEET QTi DALI 4X14/24 DIM

AC Backward Curved Motorized Impellers

HEAT RECOVERY AIR HANDLING UNIT

客戶承認書 SPECIFICATION FOR APPROVAL CUSTOMER P/N: DELTA MODEL: ASB02512VHA-A76N REV: 01 SAMPLE ISSUE DATE: 12/08/2016 QUANTITY:

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Instructions for the BASIC BCRW Fan, Sizes General

E3M-V. Mark Sensor. Applications

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

Class 1 laser beam sensor safe for your eyes

Original instructions. Operation Manual & Cautions

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Thermostat Catalog 2004

Installation Guide for models:

Technical Data. Dimensions

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Temperature Sensor TRG Original Installation Instructions English

Series Temperature Controller Instruction Sheet

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Installation Guide for models:

Transcription:

The engineer's choice

4114 N/17HH-218 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output - Alarm... 5 3.3 Electrical Features... 6 3.4 Aerodynamics... 7 3.5 Sound Data... 8 4 Environment... 8 4.1 General... 8 4.2 Climatic Requirements... 8 5 Safety... 9 5.1 Electrical Safety... 9 5.2 Approval Tests... 9 6 Reliability... 9 6.1 General... 9

1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft Fan Clockwise Air intake over struts Ball bearing Any 2 Mechanics 2.1 General Width Height Depth Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 119,0 mm 119,0 mm 38,0 mm 0,390 kg Metal Plastic Wire outlet corner: 420 Ncm Remaining corners: 600 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Lead wire length Wires L = 995 mm Wire size (AWG) 22 Insulation diameter 1,70 mm +- 10,0 mm Wire Color Operation 1 red + UB 2 blue - GND 3 white Alarm The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery. 03/02/2017 page 3 of 10

3 Operating Data 3.1 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range U 18 V 28 V Nominal voltage U N 24 V Power consumption p = 0 8 W 12 W 12,9 W P +- 17,5 % +- 12,5 % +- 15 % 0010 Current consumption p = 0 445 ma 510 ma 460 ma I +- 17,5 % +- 12,5 % +- 15 % 0010 Speed p = 0 4.250 1/min 5.000 1/min 5.030 1/min n +- 12,5 % +- 7,5 % +- 10 % 0010 Starting current consumption 800 ma 03/02/2017 page 4 of 10

3.2 Electrical Interface - Output - Alarm Alarm type /17 (high = ok, open collector) Features Note Values Alarm operating voltage U BA Min.: 4,5 V Max.: 40 V Alarm signal Low U A low I sink: 20 ma < 1 V Alarm signal High U A high I source: 15 V Leakage current 50 ua External resistor External resistor Ra from UBA to UA required. All voltage measured to GND. Alarm start-up delay time t 6 <= 10 s +- 0,5 s Alarm trip speed limit n G 1.550 1/min +- 100 1/min Alarm at sense failure Alarm latch Alarm isolated from motor No No No Alarm start-up delay time t2 when switch-on the fan. During operation is t2 = 0 s. 03/02/2017 page 5 of 10

3.3 Electrical Features Electronic function Reversed polarity protection Max. residual current at U N Locked rotor protection Locked rotor current at U N Clock signal at locked rotor Speed-Controlled Rectifying diode I F <= 10 ma Auto restart I block approx. 1.000 ma t 3 / t 4 typical: 0,5 s / 5 s 03/02/2017 page 6 of 10

3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 5.000 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 260,0 m3/h Max. static pressure ( p = max. / =0) 250 Pa 03/02/2017 page 7 of 10

3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 5.000 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 160,0 m3/h @ 100 Pa 6,7 bel(a) 60,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 55 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 80 C 4.2 Climatic Requirements Humidity requirements Water exposure Dust requirements Salt fog requirements humid heat, constant; according to DIN EN 60068-2-78, 14 days None None None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. Please require severity levels and specification parameters from the responsible development departments. 03/02/2017 page 8 of 10

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. Clearance / creepage distance Protection class 500 VAC / 1 Min. 500 VAC / 1 Sec. RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes / UL507, Electric Fans VDE Association for Electrical, Electronic and Information Technologies Yes / Approval acc. to EN 60950 (VDE 0805) - Information technology equipment CSA Canadian Standards Association Yes / C22.2 No. 113 Fans and Ventilators CCC China Compulsory Certification Not applicable 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. Life expectancy L10 acc. to IPC 9591 at TU = 40 C 70.000 h 50.000 h 117.500 h 03/02/2017 page 9 of 10