Efficient and comfortable air conditioning solutions for every requirement GEA Flex-Geko Comfort Edition

Similar documents
Product Brochure Fan coil units Flex-Geko Comfort -Edition. Efficient and comfortable air conditioning solutions for every requirement

GEA Fan Coil Units Effective and quiet. Quality in detail GEA Cassette-Geko. Product Brochure

Product Brochure Fan Coil Units Effective and quiet HyCassette-Geko and Cassette-Geko. Quality as a sign of the times

HyCassette-Geko & Cassette-Geko» Fan Coil Units

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

Product Brochure Unit heaters for retail and industrie MultiMAXX. Flexible, powerful, diversified

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Product Brochure Air Handling Units with Double-Plate Heat Exchanger CAIRplus SX ECOTWIN cool. Energy efficiency through adiabatic cooling

GEA Air Handling Units Modular configuration. Integrated refrigeration with optimized energy efficiency GEA CAIRplus.

Flexible and efficient: Close Climate Control for IT equipment

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

CASSETTE UNIT. Comfort Circle

Lovely and flexible Fan Coil Units. GEA Flex-Geko. Solutions for all demands Basic and Comfort. Air Treatment

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Press Folder IFH/Intherm 2008

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Product brochure For a good working environment under extreme conditions Intelligent air treatment with CAIRplus Air Handling Units

Industrial cooling systems LT

Heating and Drying Ovens HeatEvent

Product Brochure Modular Air Handling Units CAIRplus. Multiflow liquid-coupled energy recovery system

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

SIMPLICITY FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY?

GMM Güntner Motor Management

COOLSTREAM S T A R PRODUCT OVERVIEW COOLSTREAM S T A R

Heating and Drying Cabinets HeatEvent

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

Liebert CW kW. Chilled Water Cooled Precision Air Conditioning For Data Centers. Precision Cooling For Business-Critical Continuity

APPLICATION BROCHURE Chillers and Heat Pumps Hydraulics Manual. Suggestions for the hydraulic integration of chillers and heat pumps

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

GEA Niro drying systems. We know what makes outstanding polymers. engineering for a better world. GEA Process Engineering

Flexible & Innovative. Cooling Solutions

Press. Heat pumps from Viessmann: efficient heat generation with renewable energy and electricity

Control Products & Systems OEM

Constant climate chamber with ICH-compliant illumination

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Cassette units Model Comfort Circle. - heating - cooling - ventilation

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

GEA S-Tec spiral freezers and chillers. Hygienic food processing

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

Gas condensing boiler (wall mounted) TopGas

Güntner Info GVX. with microox technology kw. Always a step ahead: microox condenser system with maximum installation flexibility

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Air Handling Unit Airblock FG

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

Constant climate chamber with humidity

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Modular Air-cooled Chillers

SIHI dry Dry running vacuum pumps

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

QUICK SELECTION GUIDE Decentral Systems Industry MultiMAXX Multi Flair RoofJETT. Optimal Assistance in Pre-Selection of Units

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Constant climate chambers

air handling units AT THE LEADING EDGE OF AIR FLOW

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

Top Performance A New Level of Washing Efficiency

The quick and convenient way to heat any room. Generating efficient heat as needed with temporary heaters

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling

OPERATING MANUAL Enertronic Control System 2

Rapid. Suspended Warm Air Heater. Caring for the environment!

- Data Brochure Universal Reset Module 422

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

L CONNECTION NETWORK Commercial Controls

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

Be sustainable while protecting your business

Constant climate chambers

Enriching Environments

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

An Efficient Cold Store Facility

VRV The total solution. Integrated Climate Control

LAUDA Proline Edition X

GEA A-Tec spiral freezers and chillers. In touch with GEA Refrigeration Technologies hygienic food processing. GEA Refrigeration Technologies

TopVent Design Handbook

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

- Data Brochure Universal Reset Module 423

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

Menerga Adconair Various solutions one heat recovery system

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

Comfort Control TAC Operating Manual

CONVENIENT FEATURES ...MORE PERFORMANCE LESS... SPACE ENERGY NOISE G-TEC BELT-DRIVEN ROTARY SCREW AIR STATION. 7.5 to 22 kw 8 to 13 bar

Mitsubishi Electric Guide to Chiller Technologies. Information Guide 58

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

WHITE PAPER: Thermal Management Solutions

Refrigeration Compressed Air Dryer Boreas Variopulse

Neosys Product catalogue

Compact. Efficient. TROX.

Underfloor heating systems for new build and modernisation

The New Cooling Unit Generation Blue e+

DX AIR CURTAIN. SensAir

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

SWIMMING POOL AIR MANAGEMENT DanX

Transcription:

GEA fan coil units with HX Factor Efficient and comfortable air conditioning solutions for every requirement GEA Flex-Geko Comfort Edition Product Brochure engineering for a better world GEA Heat Exchangers

Heat exchanging with HX factor The HX Factor is our performance promise. It stands for unique competence in heat exchangers (HX = HEAT EXCHANGE) and ensures you diverse great product benefit. The GEA Flex-Geko fan-coil units ensure a whisperquiet and comfortable feel-good climate at maximum energy efficiency and optimal room airtemperature distribution. [ 2 ] PR-203-0020-GB Subject to modifications K-02/204

Efficient solutions for a comfortable climate Whoever treats air must master it World-wide leaders in heat exchangers As an internationally active technology corporation, the GEA Group concentrates on process technology and components for demanding production processes in diverse final markets. GEA is a market and technology leader in all business sectors. GEA Heat Exchangers the largest segment of GEA bundles all activities in the area of heat exchangers and air treatment systems and probably has the world-wide largest product range in this field. And our HX-Factor is what makes GEA Heat Exchangers unique and a preferred partner. Heat exchange and air treatment with HX-Factor: this means a perfect fit, reliable and sustainable solutions as a sign of the times. GEA fan convectors prove our quality and innovation capability. Decentralized air treatment with high comfort and convincing unit efficiency Where heating, cooling, cleaning, filtering, humidification and dehumidification of air is required, GEA makes its contribution to progress. Customized climate control and air treatment, with the maximum-possible reduction of energy consumption over the entire life cycle of the facilities: this all pays out handsomely in euros and cents, in comfort, and in work productivity. Our climate control solutions reliably satisfy all international standards and current statutory guidelines. Summarized with the concept "HX factor", this quality justifies our technological advantage. The HX factor is more than a technology. It is an attitude and creates values with a future: quality of life for residents and users. Protection of energy resources and our climate. Security for investors and planners. Rapid and efficient heating, cooling and ventilation with one unit Unlike radiators and classical flat radiators, fan-coil units not only can heat rooms, but can also cool and ventilate them. Your partner for air treatment More than 40 years of experience Customized air quality and a healthy, comfortable indoor climate with extremely low-noise operation and maximum energy efficiency With state-of-the-art technology while compliant with current legal directives Certified quality Simple system integration Low maintenance costs GEA fan-coil units offer all possibilities of a demand-controlled technology and can be employed everywhere, where comfortable warmth, cooling or air ventilation with a rapid adaptation is required. GEA fan-coil units actively guide the air to be processed through the heat exchanger, whereby it is heated and cooled particularly effectively. They bring room air to the desired temperature faster, and operate with smaller heating or cooling surfaces. Their enhanced heat transfer enables lower feed temperatures during heating, and higher feed temperatures during cooling. This minimizes losses and saves energy between the boiler or the chiller and the final unit. PR-203-0020-GB Subject to modifications K-02/204 [ 3 ]

Comfortable air conditioning solution Energy-efficient operation Diverse application options Great planning freedom and security GEA Flex-Geko is suited for every use Because of their modular concept, GEA Flex-Geko (Geko is a designation for fan convectors) can be employed for the most diverse applications. They heat, cool and ventilate offices, salesrooms and public facilities. Leading hotel chains gladly employ GEA Flex-Geko because of their reliable and quiet operation. With economical operation and flexible usage options, these fan-coil units set the standard for modern and energy-efficient climate solutions. GEA Flex-Geko satisfies practically all wishes GEA Flex-Geko are suitable both for wall as well as for ceiling mounting. They function highly satisfactorily on a stand-alone basis with casing, or can be mounted virtually invisibly as base units with the required air outlets behind a wall or above a suspended ceiling. The GEA MATRIX control, which can be integrated upon request, adapts to the desired functionality. The operator control units with or without integrated timer switches provide the interface to the user. The control units can be installed in the units themselves, or externally. [ 4 ] PR-203-0020-GB Subject to modifications K-02/204

Homogeneous room air temperature distribution Low-noise comfort Intelligent control system Flexible mounting options With 2-liter units, seasonal switch-over from heating to cooling operations is possible, and vice-versa (by reversing the medium supply). The 4-liter units additionally offer connections for heating and cooling circulation systems, and therefore allow spontaneous change-over between modes of operation. The GEA Flex-Geko with a primary air connection can easily be combined with central air handling. The control interfaces likewise allow uncomplicated integration into the building-services management system. With flexible selection levels or continuously variable fans as well as valves for influencing the mass flow, the performance of the units can be optimally controlled. Adjustable air discharge grilles furthermore ensure a uniform distribution of the temperature-controlled air in the room. Flexible installation and installation versions Building integration behind wall or in suspended ceiling The flexible GEA MATRIX control system adapted to the required functionality Connecting into the building management system with diverse interfaces Combination with other Geko or GEA products is possible Recirculating-air units according to VDI 6022, certified by ILH Berlin PR-203-0020-GB Subject to modifications K-02/204 [ ]

The correct model for every requirement Performance diversity and model sizes The basic variant of the GEA Flex-Geko already offers solid technology for many applications. The entry-level unit is suitable for user-friendly heating and/or cooling in recirculating-air operation and can be combined with various accessories. For additional information on the Basic Edition, please consult our "Data & Facts". Figure: Recirculating-air basic device without casing, ceiling model Many unit configurations with various system components are possible based on a common unit platform of the GEA Flex-Geko. Diverse accessories and control components ensure that GEA Flex-Geko can satisfy all demands. Already the basic variant contains high-quality technology. and depending on the model offers connections for warm and/or cold water, a three-speed fan, and an air filter. Different valve types permit harmonized and precise heating or cooling. With the GEA Flex-Geko Comfort Edition, it is possible to air condition rooms in recirculating-air or mixed-air operation especially quietly and to clean the air with fine filters. They can be equipped with additional electrical heating, and with an integrated direct evaporator, allowing a combination with outdoor split-climate units. The casing is designed for various intake and discharge versions. Flow-optimized air routing is thus guaranteed for all applications. Especially for low-energy applications such as heat pumps, for example, the GEA Flex- Geko also offers additional heat exchanger versions which are optimized for low heating medium or high coolant temperature and small mass flows. The GEA Flex-Geko fan-coil units are available in eight different model sizes which with a casing height from 04 millimeters and a depth of millimeters. Depending on the capacity, the width varies between 40 and,90 millimeters. The eight unit sizes permit an optimal selection of the required capacity. The heating and cooling capacities lie between and 20 kilowatt *). The air volume flow harmonized to these ratings varies between 0 and,00 cubic meters per hour. Figure: Basic mixed-air unit without casing, wall model *) Heating PWW 0 / 0 C, tl + 20 C; cooling PCW 6 / 2 C, tl + 2 C, 46 % r.h. [ 6 ] PR-203-0020-GB Subject to modifications K-02/204

The correct outfit for every situation Combination versatility and flexibility The many possible intake and discharge combinations and casing versions, the extremely quiet fans as well as the different installation options (wall, ceiling, suspended ceiling) makes GEA Flex-Geko models something special. GEA Flex-Geko is equipped for practically all existing spatial configurations and exceptional installation situations. The following directional designations refer to a wall installation: 2 3 4 6 2 3 4 6 Intake below discharge above: about 0 cm space is required on the intake side for recirculating-air operation for wall or ceiling mounting. Casing with adjustable plastic or rigid aluminum air-discharge grille. Without feet. Intake below discharge in front: for wall or ceiling mounting, about 0 cm space is required intake-side for recirculating-air operation. Casing with adjustable plastic air-discharge grille. Without feet. Intake in front discharge above: for recirculating-air operation for wall, ceiling or floor assembly. For free installation in the room with optional back wall. Intake opening integrated with grille in casing Casing with adjustable plastic or rigid aluminum air-discharge grille. Without feet. Intake in front blow out in front: for recirculated-air operation for wall, ceiling or floor assembly. Intake opening integrated with grille in casing Casing with adjustable plastic air-discharge grille. Without feet. Intake below discharge above: for recirculating-air operation for wall, ceiling or floor assembly. Intake opening without grille Casing with adjustable plastic or rigid aluminum air-discharge grille. with unit leveling feet Intake below blow out in front: for recirculating-air operation for wall, ceiling or floor assembly. Intake opening without grille Casing with adjustable plastic air-discharge grille. with unit leveling feet Intake in front discharge above: for recirculating-air and mixed-air operation for wall, ceiling and floor assembly. Recirculating-air intake opening with grille integrated in the casing. Outside air-intake opening rear-side without grille. Casing with adjustable plastic or rigid aluminum air-discharge grille. with unit leveling feet Intake in front discharge in front: for recirculating-air and mixed-air operation for wall, ceiling and floor assembly. Recirculating-air intake opening with grille integrated in the casing. Outside air-intake opening rear-side without grille. Casing with adjustable plastic air-discharge grille. with unit leveling feet 2 3 4 6 PR-203-0020-GB Subject to modifications K-02/204 [ ]

Air conditioning equipment details Conceived for highest demands on energy efficiency and comfort Sustainability is the keyword of our time. Investors, plant engineers, planners, and architects no longer ask "whether" but "how" they can enhance the degree of sustainability of their plants and building management systems. Buildings are unique objects. Location, size, construction quality, and increasingly, building engineering technology determine values and returns. Energy matters substantially gain in significance since buildings absorb about 40% of the world energy consumption and produce 2% of world-wide greenhouse gas emissions. The proportion of the energy costs in the "second rent" for users and residents is constantly increasing. The fact that our air treatment is neither seen nor heard, although one is agreeably aware of it, and that in the meantime it avoids energy and wasteful costs, is due to our precision air-treatment work in both hardware and software. Your advantages at a glance Very high efficiency Up to 0% reduced electrical power consumption of the fan Whisper-quiet with continuously variable speed control Precise room temperature control Satisfies current ErP directives Tested and certified by EUROVENT With GEA Flex-Geko, we have succeeded in creating a model series which convinces both under the aspect of sustainability as well as comfort. The optimal energy efficiency of the units makes a significant contribution to the conservation of valuable resources and the preservation of the environment. Decreasing operating costs simultaneously promote cost effectiveness -- an advantage which rapidly pays for itself even for the smallest rooms and plants. EC technology: high-performance, sustainable, whisper-quiet EC fans not only ensure demand-driven air delivery and individual control possibilities. Compared to conventional AC fans, the EC motors convince with a reduced electrical power consumption of up to 0%. It always works under optimal conditions, resulting in maximum torques and minimal losses. GEA fan-coil units with EC technology satisfy the current ErP guidelines (Energy Related Products Directive). [ ] PR-203-0020-GB Subject to modifications K-02/204

Tested and certified High production quality and reproducible data are standard for our GEA Flex-Geko. As a member of EUROVENT and the German Association of HVAC Manufacturers (RLT), our production facilities, units, and their capacities are regularly tested and monitored by independent parties. The continuously-variable speed control of the EC fans offers a number of additional advantages. Since fan speed changes are inaudible, they are whisper-quiet in operation, and satisfy the highest demands on acoustic comfort. In addition, the room temperature control is more precise, since it can react to temperature deviations with an appropriately adapted fan speed. This is supported by using hydraulic modulating control valves. The variable fan speed control furthermore compensates fluctuating hea- GEA Flex-Geko GF.UWW.SE0A NON DUCTED FAN COILS ENERGY EFFICIENCY ting and cooling medium conditions, e.g. seasonally-caused variations of inlet temperatures of the heat generator or fluctuating volume flow. The GEA MATRIX control is COOLING MODE Total cooling capacity at high speed: Sensible cooling capacity at high speed: 4.4 3. kw kw continuously harmonized with the EC fans and is furnished with special features and controls, for instance the continuously variable automatic operation. A speed limitation (= automatic quiet function) can be switched on. The manual operation permits individual and demand-driven control of the operating points of the Geko. FAN COILS UNITS ;OM-A-202 ;T202 THRESHOLD REFERENCE SCALE YEAR : 204 204 Approved 0/06/202 PR-203-0020-GB Subject to modifications K-02/204 [ 9 ]

Comfort control GEA Drive For maximum comfort and efficiency GEA Drive is an innovative, motor-controlled discharge profile for optimizing the air velocity and air throw in cooling operation. Depending on the speed of the fan and the supply and room temperatures, GEA Drive ensures an improved room air flow and a more uniform room air temperature distribution. The favorable air-flow profile of the GEA drive achieves an optimal leaving-air cross-section even at lowest fan speed. The highest degree of comfort and efficiency is achieved with EC fans and the control GEA MATRIX. Reduction of electrical energy with EC fans and GEA Drive Fan power consumption [W] 0 60 0 Fan electric power consumption.400.200 40 00 30 600 20 400 0 200 0 0 9 0 2 3 4 6 Time.000 Refrigeration demand [W] With EC fans: 60 % savings of electrical energy thanks to higher efficiency of EC - Motors and continuously variable speed control With GEA drive: An additional % reduction of electrical energy through optimized air-flow design and temperature distribution AC fan EC fan EC fan+gea drive refrigeration demand Reduction of cooling energy with GEA Drive.400 Refrigeration demand.400.200.200 Total cooling capacity [W].000 00 600 400.000 00 600 400 Refrigeration demand [W] With GEA drive: % savings of cooling energy through optimized air flow and temperature distribution 200 200 0 0 9 0 2 3 4 6 Time EC fan EC fan+gea Drive refrigeration demand [ 0 ] PR-203-0020-GB Subject to modifications K-02/204

Example of cooling operation (partial load) Conference room 30 m 2 Supply-air temperature 4 C GEA Flex-Geko model size3 Volume flow 300 m 3 / h (3%) Internal loads 2 W/m 2 CFD computational fluid dynamics Because of the small cooling capacity required, low speeds of the unit's fan are automatically selected in partial-load range. But in order to achieve an optimal leaving-air velocity and roomair distribution without increasing the speed, the GEA Drive Comfort Control now ensures a continuously-controlled reduction of the leaving-air cross-section. The velocity of the air jet is thus increased without increasing the speed, and the air jet moves smoothly along the wall and ceiling (Coanda effect). This leads to a considerably increased penetration depth into the room. The noticeable result is increased comfort with perfect temperature and velocity distribution in the occupied zone, as well as great acoustic comfort due to the low speeds of the fan. with GEA Drive occupied space according to DIN EN 39 without GEA Drive occupied space according to DIN EN 39 30 C 22 C 4 C PR-203-0020-GB Subject to modifications K-02/204 [ ]

Intelligent regulating technology Always the right idea for the right climate with the GEA MATRIX If requested, the proven GEA MATRIX control will already be integrated into the GEA Flex-Geko at the factory. Completely tested units are thus available on the construction site. The GEA MATRIX is available in the expansion stages 00, 2000, 3000 and 4000 harmonized to diverse applications. For instance, a version for EC fans (M 3000 / M 4000) and GEA Drive (M 4000), a version for hotel applications, or also a basic version for small budgets are all available. The standard versions of most of the MATRIX models provide a 2-conductor GEA MA- TRIX.NET bus system that allows communication among all GEA MATRIX units. This makes it very easy to implement day and night operation, control the pumps, and collect fault signals in one place. GEA MATRIX can also be connected to higher-level bus systems. Your advantages at a glance Comprehensive control options Control functions in various expansion stages Plug-and-play functionality Energy-optimized operation of the units Ready-to-operate units and competent service Global add-on modules LON connection Service tool available and much more. GEA MATRIX furthermore ensures an energy-optimized operation of the GEA Flex- Geko. A coordinated switchover function, for example, prevents heating and cooling circulation systems from working against each other. With summer compensation, GEA MATRIX takes the outside temperature influence into consideration and thereby prevents an energy-intensive climate control. Hardware and software are developed entirely at GEA. By close collaboration within the company, the engineers can specifically harmonize the controls with every component, and thus optimally exploit the possibilities of the units. Service and support also benefit from this arrangement, and can rapidly and competently react whenever questions arise. Numerous additional global modules are available for the functional enhancement of the available standard local connections of the GEA MATRIX control system: whether intra-group control panels or timer modules, modules for the control of exhaust air fans or chillers, the extension of analog or digital input and output signals, outputs from 0 to 0 volt for valves, or the connection of a LON bus system according to the LonWorks standard. Starting with the GEA MATRIX 2000, all modules can be easily integrated with the MATRIX.Net bus system. Furthermore, the service tool MATRIX.PC can be deployed for the parameterization, commissioning, maintenance and data recording of the GEA MATRIX control system. [ 2 ] PR-203-0020-GB Subject to modifications K-02/204

Control panel for GEA MATRIX 00 Control panel for GEA MATRIX 2000 MATRIX OP MATRIX OP 2 Casing without display, pure white Recirculated-air operation, IP 20 enclosure class Setpoint temperature setting Speed selector switch for continuous operation Economy mode button LED display operation/ fault/ ext. influence Integrated room temperature sensor As for OP control panel, however with Speed-selection switch Continuous/automatic operation MATRIX.Net data bus: Network connection for MATRIX add-on modules with OP 2control panel Control panels for GEA MATRIX 3000 and GEA MATRIX 4000 MATRIX OP 30 without key MATRIX OP 3 with economy mode key MATRIX OP 44 Casing without display, pure white Recirculated-air operation, IP 20 enclosure class Setpoint temperature setting Speed switch for continuous/automatic operation LED display operation/ fault/ ext. influence Integrated room temperature sensor as for the OP3 control panel, but with Changeover between heating/cooling/automatic operation Changeover between recirculating-air / mixed-air operation. All control panels without display and optionally with protective cover MATRIX OP 0 without clock MATRIX OP with clock MATRIX.IR infrared remote control unit Casing with display, pure white Recirculating air / mixed-air operation Protection class IP 20 Operation with rotary navigator LCD display with plain-text display Status report by pictograms Integrated room-temperature sensor Functions like OP 44 control panel, however without operational / error messages without messages on ext. influence without integrated room sensor Black casing, similar to RAL 9004 LCD display 4 x 30 mm Transmission range about 20 m PR-203-0020-GB Subject to modifications K-02/204 [ 3 ]

Recirculating air cooling and heating 2 - pipe system chilled water /water water Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm m 3 /h kw kw AC motor EC motor Width Weight 2 3 4 6 0 30 60 40 20 90 290 990 300.00 430.30 460.420 90.20,0 3,0,2 3,4,,3 2,0 6,2 2, 6, 2,6,6 2,9, 3, 0,,, 2,0 6,2 3,2 9,6 3,, 3, 2,0 4,9 4,2,4,9 6, 9,6 2 db(a) 0 db(a) 2 db(a) db(a) 0 db(a) db(a) 24 db(a) 4 db(a) 24 db(a) 3 db(a) 2 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 0 db(a) 22 db(a) 0 db(a) 0 db(a) db(a) 24 db(a) 3 db(a) 24 db(a) 4 db(a) 26 db(a) 3 db(a) 3 W 3 W 32 W 6 W 6 W 3 W 6 W W 6 W W 0 W 9 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,06 A 0,4 A 0,0 A 0,4 A 0,0 A 0,0 A 0,0 A 0, A 0,0 A 0,64 A 0, A 0,9 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46 % r.h., medium PCW 6 / 2 C heating capacity at room temperature 20 C, medium PWW 0 / 0 C A special heat exchanger is available upon request for low heating medium temperatures or high refrigerant temperatures. Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". [ 4 ] PR-203-0020-GB Subject to modifications K-02/204

Recirculating air cooling and heating 2 - pipe system chilled water /warm water Electric heating ~ 230 V, 0 Hz Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm 2 m 3 /h kw kw kw AC motor EC motor Width Weight 2 3 4 6 220 30 230 40 30 90 360 990 30.00 60.30 0.420 690.20,2 3,0, 3,4 2,0,3 2,3 6,2 2, 6, 3,,6 3,, 4,2 0, 2,3, 2,6 6,2 3, 9,6 4,, 4,4 2,0,9 4,2 6,4,9,6 9,6 0,,4,2 2,4,6 3,34,9 3,90 2,03 4,06 2,0 4,4 2,0 4,4 2,0 4,4 2 db(a) 0 db(a) 26 db(a) 2 db(a) db(a) 26 db(a) 0 db(a) 2 db(a) db(a) 3 db(a) 4 db(a) 30 db(a) 3 db(a) 29 db(a) 3 db(a) 2 W 63 W 2 W 6 W W 0 W W W W 3 W 3 3 W 30 W 66 W 0, A 0,2 A 0, A 0,29 A 0, A 0,3 A 0, A 0,36 A 0, A 0,3 A 0,33 A 0, A 0,33 A 0,6 A 0,33 A 0,3 A 2 db(a) 0 db(a) 2 db(a) 2 db(a) 0 db(a) 2 db(a) 0 db(a) 24 db(a) db(a) 3 db(a) 3 db(a) 30 db(a) 4 db(a) 29 db(a) 3 db(a) W 3 W W 32 W 6 W 6 W W 6 W W 6 W 0 W 6 W 0 W 0 W W 2 W 0,06 A 0,3 A 0,06 A 0,2 A 0,0 A 0,4 A 0,06 A 0,4 A 0,06 A 0,0 A 0, A 0, A 0,2 A 0,64 A 0,3 A 0,9 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46 % r.h., medium PCW 6 / 2 C Heating capacity at room temperature 20 C, medium PWW 0 / 0 C and ~ 230 V, 0 Hz Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ ]

Recirculating air cooling and heating 4 - pipe system chilled water / warm water Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm m 3 /h kw kw AC motor EC motor Width Weight 2 3 4 6 4 2 3 2 0 2 90 29.000 42.29 4.40.00 0,9 2,3,0 3,0, 4,3 2,0,2 2,0, 2, 6,4 3,2,4 3,9 9, 0,6,,0 2,2, 3,3,2 4,0 2, 4, 2,9, 3,2, 3,9,0 2 db(a) 0 db(a) 2 db(a) db(a) 0 db(a) db(a) 24 db(a) 4 db(a) 24 db(a) 3 db(a) 2 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 0 db(a) 22 db(a) 0 db(a) 0 db(a) db(a) 24 db(a) 3 db(a) 24 db(a) 4 db(a) 2 db(a) 3 db(a) 3 W 3 W 32 W 6 W 6 W 3 W 6 W W 6 W W 0 W 9 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,06 A 0,4 A 0,0 A 0,4 A 0,0 A 0,0 A 0,0 A 0, A 0,0 A 0,64 A 0, A 0,9 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46 % r.h., medium PCW 6 / 2 C heating capacity at room temperature 20 C, medium PWW 0 / 0 C A special heat exchanger is available upon request for low heating medium temperatures or high refrigerant temperatures. Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". [ 6 ] PR-203-0020-GB Subject to modifications K-02/204

Recirculating air cooling and heating Direct expansion coil / warm water Model size Speed Air flow rate Cooling capacity DV Heating capacity PWW Refrigerant R40A Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm 3 m 3 /h kw kw t 0 AC motor EC motor Width Weight 2 3 4 6 20 2 20 3 46 0 4 90.000 4.29 6.40 9.00,0,3,,6, 2,6,9 2, 2, 3,0 2, 3,9 3, 4,6 3, 4,9,0,4,4 2,0 2,2 3, 2,6 3, 3,0 4,2 4,0,3 4,3,9,2,2 0 C 0 C 0 C 0 C 0 C 0 C 0 C 0 C db(a) db(a) db(a) 32 db(a) 0 db(a) 33 db(a) db(a) 3 db(a) 4 db(a) 39 db(a) 3 db(a) 39 db(a) 3 db(a) 0 W 63 W 2 W 6 W 0 W 3 W W 99 W 3 00 W 99 W 66 W 0,23 A 0,2 A 0,24 A 0,29 A 0,22 A 0,3 A 0,2 A 0,36 A 0,24 A 0,3 A 0,4 A 0, A 0,46 A 0,6 A 0,46 A 0,3 A 32 db(a) 32 db(a) 4 db(a) 0 db(a) 32 db(a) 0 db(a) 32 db(a) 0 db(a) 3 db(a) 2 db(a) 36 db(a) 3 db(a) 3 db(a) 2 db(a) W 3 W W 32 W W 6 W W 6 W 9 W 6 W 6 W 6 W W 0 W 2 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,0 A 0,4 A 0,09 A 0,4 A 0,09 A 0,0 A 0, A 0, A 0, A 0,64 A 0,2 A 0,9 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacities at room temperature 2 C / 46 % r.h., medium refrigerant R40A t 0 = 0 C heating capacity at room temperature 20 C, medium PWW 0 / 0 C Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ ]

Recirculating air cooling Direct evaporator Model size Speed Air flow rate Cooling capacity DV Heating capacity PWW Refrigerant R40A Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm 3 m 3 /h kw t 0 AC motor EC motor Width Weight 2 3 4 6 20 30 20 40 40 90 490 990 20.00 0.30 0.420 90.20,2,,4 2,3 2, 3, 2,4 3,6 2,6 4,2 3,,6 4,2 6,4 4,6, 0 C 0 C 0 C 0 C 0 C 0 C 0 C 0 C 33 db(a) 0 db(a) 33 db(a) db(a) 32 db(a) 0 db(a) db(a) 3 db(a) 4 db(a) 3 db(a) 3 db(a) 3 db(a) 3 db(a) 0 W 63 W 2 W 6 W 0 W 3 W W 99 W 3 00 W 99 W 66 W 0,23 A 0,2 A 0,24 A 0,29 A 0,22 A 0,3 A 0,2 A 0,36 A 0,24 A 0,3 A 0,4 A 0, A 0,46 A 0,6 A 0,46 A 0,3 A 33 db(a) 0 db(a) 32 db(a) 0 db(a) 33 db(a) 0 db(a) 33 db(a) db(a) 3 db(a) 3 db(a) 3 db(a) 4 db(a) 3 db(a) 3 db(a) W 3 W W 32 W W 6 W W 6 W 9 W 6 W 6 W 6 W W 0 W 2 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,0 A 0,4 A 0,09 A 0,4 A 0,09 A 0,0 A 0, A 0, A 0, A 0,64 A 0,2 A 0,9 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacities at room temperature 2 C / 46 % r.h., medium refrigerant R40A t 0 = 0 C heating capacity at room temperature 20 C, medium PWW 0 / 0 C Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". [ ] PR-203-0020-GB Subject to modifications K-02/204

Recirculating air heating Electric full heating system 3 ~ 400 V, 0 Hz Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing and without foot Height Depth 4 mm 22 mm 3 m 3 /h kw AC motor EC motor Width Weight 2 3 4 6 20 30 20 40 40 90 490 990 20.00 0.30 0.420 90.20 2,0 4,4 2,2,04 3,69,3 4,20,40 4,9 9, 4,9 9,96 6, 2,36 6, 2,36 33 db(a) 0 db(a) 33 db(a) db(a) 32 db(a) 0 db(a) db(a) 3 db(a) 4 db(a) 3 db(a) 3 db(a) 3 db(a) 3 db(a) 0 W 63 W 2 W 6 W 0 W 3 W W 99 W 3 00 W 99 W 66 W 0,23 A 0,2 A 0,24 A 0,29 A 0,22 A 0,3 A 0,2 A 0,36 A 0,24 A 0,3 A 0,4 A 0, A 0,46 A 0,6 A 0,46 A 0,3 A 6 mm kg 9 mm 20 kg.06 mm 2 kg.2 mm 29 kg.36 mm 32 kg. mm 3 kg.66 mm 42 kg. mm 4 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Heating capacity at room temperature 20 C, medium 3 ~ 400 V, 0 Hz Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm 2 990 mm 04 mm 04 mm mm kg mm 9 kg 3.40 mm 04 mm mm 0 kg 04 4.290 mm 04 mm mm kg Without unit foot casing.440 mm 04 mm mm 2 kg 6.90 mm.40 mm 04 mm 04 mm mm 3 kg mm 4 kg 04 2.90 mm 04 mm mm kg With unit foot casing Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ 9 ]

Mixed air cooling or heating 2 - pipe system chilled water / warm water Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing Height Depth 96 mm 22 mm m 3 /h kw kw AC motor EC motor Width Weight 2 3 4 6 4 49 0 20 2 0 20 9 20 90 40.20 43.320 30.640 0,9 2,, 3,3,6,0,9,9 2, 6, 2,,2 2,,3 3, 0,2 2, 6,6 2,4,6 3,,3 4, 3,2 4, 4,3 6,0,0 6, 9,,9 23,0 2 db(a) 0 db(a) 2 db(a) db(a) 0 db(a) db(a) 24 db(a) 4 db(a) 24 db(a) 3 db(a) 2 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 2 db(a) 0 db(a) 22 db(a) 0 db(a) 22 db(a) 0 db(a) db(a) 26 db(a) 4 db(a) 26 db(a) 4 db(a) 2 db(a) 3 db(a) 3 W 3 W 32 W 6 W 6 W 3 W 6 W W 6 W W 0 W 9 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,06 A 0,4 A 0,0 A 0,4 A 0,0 A 0,0 A 0,0 A 0, A 0,0 A 0,64 A 0, A 0,9 A 6 mm kg 9 mm 22 kg.06 mm 2 kg.2 mm 32 kg.36 mm 36 kg. mm 42 kg.66 mm 46 kg. mm 2 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46% r.h., medium PCW 6 / 2 C thermal output at air intake temperature 0 C, medium PWW 0/0 C A special heat exchanger is available upon request for low heating medium temperatures or high refrigerant temperatures. Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm mm mm 9 kg 2 990 mm mm mm 0 kg 3.40 mm mm mm kg 04 2 04 4.290 mm mm mm 2 kg Air outlet above.440 mm mm mm 3 kg 6.90 mm mm mm 4 kg.40 mm mm mm kg 04 2 20 04.90 mm mm mm 6 kg Air outlet in front Additional technical information is provided in our detailed documentation "Data & Facts". [ 20 ] PR-203-0020-GB Subject to modifications K-02/204

Mixed air cooling and heating 4 - pipe system chilled water / warm water Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing Height Depth 96 mm 22 mm m 3 /h kw kw AC motor EC motor Width Weight 2 3 4 6 4 490 0 20 00 20 90 20 94 40.200 430.30 2.62 0,9 2,2,0 2,9, 4,,9,0,9,6 2, 6, 3,0, 3,,6,0 2,,3 2, 2, 4, 2,4 4,9 2,,6 3,6 6,3 4,0,2 4,, 2 db(a) 0 db(a) 2 db(a) db(a) 0 db(a) db(a) 24 db(a) 4 db(a) 24 db(a) 3 db(a) 2 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 2 db(a) 0 db(a) 22 db(a) 0 db(a) 22 db(a) db(a) 2 db(a) db(a) 26 db(a) 4 db(a) 26 db(a) db(a) 26 db(a) 3 db(a) 3 W 3 W 32 W 6 W 6 W 3 W 6 W W 6 W W 0 W 9 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,06 A 0,4 A 0,0 A 0,4 A 0,0 A 0,0 A 0,0 A 0, A 0,0 A 0,64 A 0, A 0,9 A 6 mm kg 9 mm 22 kg.06 mm 2 kg.2 mm 32 kg.36 mm 36 kg. mm 42 kg.66 mm 46 kg. mm 2 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46% r.h., medium PCW 6 / 2 C thermal output at air intake temperature 0 C, medium PWW 0/0 C A special heat exchanger is available upon request for low heating medium temperatures or high refrigerant temperatures. Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm mm mm 9 kg 2 990 mm mm mm 0 kg 3.40 mm mm mm kg 04 2 04 4.290 mm mm mm 2 kg Air outlet above.440 mm mm mm 3 kg 6.90 mm mm mm 4 kg.40 mm mm mm kg 04 2 20 04.90 mm mm mm 6 kg Air outlet in front Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ 2 ]

Mixed air cooling and heating Direct expansion coil / warm water Model size Speed Air flow rate Cooling capacity DV Heating capacity PWW Refrigerant R40A Sound pressure level and motor capacity Max. dimensions and weights without unit casing Height Depth 96 mm 22 mm 3 m 3 /h kw kw t 0 AC motor EC motor Width Weight 2 3 4 6 26 490 2 430 00 460 90 490 94.200 3.30 0.62 0,9,3,,, 2,,9 2,6 2, 2,9 2, 3, 3,0 4,4 3,4 4,,4,9,9 2,6 2, 3, 3,3 4, 3,,3,0 6,,,3 6,4, 0 C 0 C 0 C 0 C 0 C 0 C 0 C 0 C 33 db(a) 0 db(a) 33 db(a) db(a) 32 db(a) 0 db(a) db(a) 3 db(a) 4 db(a) 3 db(a) 3 db(a) 3 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 3 db(a) 0 db(a) 0 db(a) 3 db(a) 0 db(a) db(a) db(a) 40 db(a) 4 db(a) 39 db(a) db(a) 3 db(a) 3 db(a) 3 W 3 W 32 W 6 W 6 W 3 W 6 W W 6 W W 0 W 9 W 2 W 0,0 A 0,3 A 0,0 A 0,2 A 0,06 A 0,4 A 0,0 A 0,4 A 0,0 A 0,0 A 0,0 A 0, A 0,0 A 0,64 A 0, A 0,9 A 6 mm kg 9 mm 22 kg.06 mm 2 kg.2 mm 32 kg.36 mm 36 kg. mm 42 kg.66 mm 46 kg. mm 2 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Cooling capacity at room temperature 2 C / 46% r.h., medium refrigerant R40A t0 = 0 C heating capacity at air intake temperature 0 C, medium PWW 0 / 0 C A special heat exchanger is available upon request for low heating medium temperatures or high refrigerant temperatures. Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm mm mm 9 kg 2 990 mm mm mm 0 kg 3.40 mm mm mm kg 04 2 04 4.290 mm mm mm 2 kg Air outlet above.440 mm mm mm 3 kg 6.90 mm mm mm 4 kg.40 mm mm mm kg 04 2 20 04.90 mm mm mm 6 kg Air outlet in front Additional technical information is provided in our detailed documentation "Data & Facts". [ 22 ] PR-203-0020-GB Subject to modifications K-02/204

Mixed air heating Electric full heating system 3 ~ 400 V, 0 Hz Model size Speed Air flow rate Cooling capacity PCW Heating capacity PWW Electric heating Sound pressure level and motor capacity Max. dimensions and weights without unit casing Height Depth 96 mm 22 mm 3 m 3 /h kw AC motor EC motor Width Weight 2 3 4 6 26 49 2 20 43 0 460 9 4 90.20 3.320.640 2,0 4,4 2,2,04 3,69,3 4,20,40 4,9 9, 4,9 9,96 6, 2,36 6, 2,36 33 db(a) 0 db(a) 33 db(a) db(a) 32 db(a) 0 db(a) db(a) 3 db(a) 4 db(a) 3 db(a) 3 db(a) 3 db(a) 3 db(a) 63 W 3 W 6 W W 0 W W 2 W W 2 W 3 2 W 22 W 66 W 0,4 A 0,2 A 0,4 A 0,29 A 0,3 A 0,3 A 0,6 A 0,36 A 0,4 A 0,3 A 0,2 A 0, A 0,2 A 0,6 A 0,2 A 0,3 A 6 mm kg 9 mm 22 kg.06 mm 2 kg.2 mm 32 kg.36 mm 36 kg. mm 42 kg.66 mm 46 kg. mm 2 kg * Sound pressure levels at quarter-spherical radiation (directional factor 4), spacing to the acoustic source 3 m, room size 00 m 3, reverberation time 0. sec. Thermal output at air intake temperature 0 C, medium 3 ~ 400 V, 0 Hz Max. dimensions and weights of the Comfort unit casing Model size Width Height Depth Weight Wall or ceiling mounting (see page ) 40 mm mm mm 9 kg 2 990 mm mm mm 0 kg 3.40 mm mm mm kg 04 2 04 4.290 mm mm mm 2 kg Air outlet above.440 mm mm mm 3 kg 6.90 mm mm mm 4 kg.40 mm mm mm kg 04 2 20 04.90 mm mm mm 6 kg Air outlet in front Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ 23 ]

Casings and accessories Diverse models and feature options Comfort unit casings and dimensions Recirculating air wall unit (see page ) Comfort unit casings and dimensions Mixed air wall unit (see page ) 04 04 04 Without foot without air intake grille 2 With foot with air intake grille air outlet front face 04 20 2 With foot without air intake grille 04 04 2 With foot with air intake grille Air outlet front side 04 04 2 With foot with air intake grille 4 20 04 92 Without foot with air intake grille in the housing 6 20 04 2 With foot without air intake grille Additional technical information is provided in our detailed documentation "Data & Facts". [ 24 ] PR-203-0020-GB Subject to modifications K-02/204

Enclosures without unit leveling feet Intake / discharge models Wall and ceiling version Recirculating air Discharge grille Plastic Disch. grille Aluminum Comfort presentation see page adjustable not adjustable Intake front face I discharge front face Intake front face I discharge front side 2 Intake front side I discharge front face 3 Intake front side I discharge front side 4 Intake front side I discharge front face I with cladding Intake front side I discharge front face I with back wall 3 3 Enclosures with unit leveling feet Intake / discharge models Wall and ceiling version Mixed air Recirculating air Discharge grille Plastic Disch. grille Aluminum Comfort presentation see page adjustable not adjustable Intake front side I Discharge front face I Without air intake grille Intake front side I Discharge front side I Without air intake grille 6 Intake front side I Discharge front face I With air intake grille Intake front side I Discharge front side I With air intake grille Accessories Accessories Suction side I wall and ceiling version Comfort Air intake plenum with primary air connection Air intake plenum with round intake fitting Seal cap DN 200 for round connector Air intake bend Intake flexible canvas connector Transition piece for intake flexible connector Intake telescope connector Intake sound attenuator for recirculating-air units Intake sound attenuator for mixed-air units Wall-recessed frame for fresh-air connector External weather-protection grille, painted RAL 9002 Wall-recessed frame for external protection grille G spare filter Spare filter G2, G3 Pressure side I wall and ceiling version Comfort Discharge plenum with primary connector, not insulated Discharge plenum with primary air connector, insulated Discharge plenum, round discharge connector, not insulated Discharge plenum, round discharge connector, insulated Seal cap DN 200 for round connector Air-exhaust bend, not insulated Air-exhaust bend, insulated Flexible canvas discharge connector Telescope discharge connector Discharge sound attenuator connector Additional technical information is provided in our detailed documentation "Data & Facts". PR-203-0020-GB Subject to modifications K-02/204 [ 2 ]

First Service Always at your side Economical right from the start The developments of GEA represent the newest state of technology. Our systems support diverse applications that optimally conform to current criteria of cost effectiveness, safety, and sustainability. Our products and services go far beyond pure technology. They are integrated into a comprehensive and in every respect customized service package. This program includes not only conventional services such as spare part delivery, maintenance, and repair. It unites the consulting and engineering of a technology leader with customized after-sales service and rapid response times. And this applies not only to installing new equipment This service also applies for upgrading and optimizing old equipment, and provides you with perfect support in all project phases The functionality of the system is secured over its entire service life. Our services at a glance Own heat exchanger manufacturer Use of certified products and components Use of components from well-known component manufacturers Short delivery times for spare parts Commissioning of new facilities Periodic servicing Maintenance Factory trial run Refurbishment and optimization of old systems Maintenance agreements International service und support in experienced hands Wherever you need us, we will be there for you in the shortest time. All over Europe, our own company customer service ensures that you are able to take optimal advantage of our units at all times. In Germany alone, many technicians are ready on-call for rapid deployment. All services are designed for absolute safety and reliability. On request, for example, a function check of all GEA components can be carried out by our service force on location, supported by an experienced GEA technician and the installer. This way we directly and personally pass on our functional know-how built up over many years. In this context, we should also mention the training sessions which we offer for our air-conditioning solutions technology. Such training is a beneficial instrument for ensuring the lasting functionality and availability of the systems A decision for quality A high quality standard is the basis and principle of all our services. All our service specialists are highly experienced and devote themselves to their work with great diligence. Technically and personally convincing: this is what you can expect from us. [ 26 ] PR-203-0020-GB Subject to modifications K-02/204

Initial installation Maintenance and servicing Assembly services Spare parts Customer service Consulting Refurbishing Training PR-203-0020-GB Subject to modifications K-02/204 [ 2 ]

We live our values. Excellence Passion Integrity Responsibility GEA-versity GEA Group is a global engineering company with multi-billion euro sales and operations in more than 0 countries. Founded in, the company is one of the largest providers of innovative equipment and process technology. GEA Group is listed in the STOXX Europe 600 Index. www.gea-airtreatment.com