Product Launch SHRMi

Similar documents
MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

Inventor of the Inverter

excellence in seasonal efficiency BUSINESS SOLUTIONS

Single Fan MiNi VRF Apartment Ready

Side blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E

Index. Toshiba Solutions. Absolute comfort

Business. The business range. The most advanced solutions for larger buildings.

DESIGN MANUAL R410A. Outdoor Unit. FS unit FILE NO. A RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE

Simultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings

Engineering Data Book

Blending Commercial and Residential. MiNi VRF

Super Modular Multi Design Manual HFC R-410A. Indoor unit. Outdoor unit

Engineering. Super Heat Recovery Multi System

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

DESIGN MANUAL R410A. Indoor Unit. Outdoor Unit FILE NO. A Cooling Only Model <Inverter Unit> Heat Pump Model <Inverter Unit>

TOSHIBA Super Heat Recovery Multi Enhanced System Standard Specification

TOSHIBA AIR CONDITIONING. TOSHIBA Super Heat Recovery Multi System Standard Specification

Engineering Data Book

Air Conditioning For Large Buildings

Technical HandBook. Version

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

Commercial Air Conditioning Equipment

TAKING OMFORT TO A WHOLE NEW DIMENSION

VRF Series. The most advanced commercial air conditioning system

Toshiba solutions 3 At Toshiba, we believe that Evolu on is leading the path to a be er future. Through the decades, we have been constantly crea ng i

ELECTRICAL QUANTITY WEIGHT (LB)

for Light Commercial Use

DC Inverter Smart VRF Products(R410A)

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Owner s Manual 1 English. Owner s Manual xx Xxxxx. Model name: <Cooling Only Model>

AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Model name: Heat Pump Model MCY-MHP0406HT-E MCY-MHP0506HT-E. English. For commercial use

Compact 4-way Cassette ( ) Type

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

Light commercial range. Passion at work. Light commer

Quick Reference. for Remote Countroller

INSTALLATION MANUAL. Outdoor Unit. Indoor Unit FILE NO. A Cooling Only Model. Heat Pump Model. Heat Pump Model

Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use

3 rd Generation of VRV. The professional solution for your professional project

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

Product Line Introduction. Karl Zhang Technical support engineer

Integrated VarIable refrigerant flow ahu/pau (r410a)

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

MMY-MAP1606HT8P-C MMY-MAP1806HT8P-C MMY-MAP2006HT8P-C MMY-MAP2206HT8P-C

SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE)

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VENTILATION. Effective heat exchange and fresh air ventilation

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

SERVICE MANUAL AIR-CONDITIONER (MULTI TYPE)

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

Light commercial range. Passion at work

Increase your flexibility.

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

AIR-TO-AIR HEAT EXCHANGERS. Air Treatment Solutions

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

Ductless Systems. Right product for the right application

Inventor of the Inverter Digital Inverter System

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

A more comfortable, safe and sustainable world

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Inverter Air Conditioning for Light Commercial Use

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Digital Inverter 4 series 8 & 10HP

Variable Refrigeration Flow Systems Overview 10/11/2016

INVERTER DUCTED SYSTEMS

Ducted inverter reverse cycle air conditioning

Control System Structure

Inverter Ducted Air Conditioners

Heat Pump Air Conditioning Systems

Variable Refrigerant Flow (VRF) Systems

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Just feel well. 2017/2018 Air conditioning

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

Toshiba s new VRF breaks ground for efficiency, Continuous heating and hands-free commissioning

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Multifamily Housing Comfort Systems Versatile and Economical Heating and Cooling

All DC Inverter Multi VRF

Air-cooled modular Chiller. Nick Technical Engineer

AIR CONDITIONER (MULTI TYPE) Owner s Manual

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

Samsung Free Joint Multi Air Conditioning System

MMY-MAP0804HT8P-E MMY-MAP1004HT8P-E MMY-MAP1204HT8P-E MMY-MAP1404HT8P-E MMY-MAP1604HT8P-E

TOSHIBA AIR CONDITIONING

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

Technology that works fast. Inverter Ducted Systems

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Air Conditioning. Air Conditioning. VRF systems

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

4-Way Cassette type. Contents MMU-AP 2H2UL

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Transcription:

Product Launch SHRMi

What s SHRM i SMMS i (High Efficiency & Reliability) Simultaneous Operation by heat recovery + = SHRM i meets various customers needs!

Refrigerant flow, cooling Liquid pipe Flow selector unit Discharge gas pipe Suction gas pipe Fan Pulse motor valve Heat exchanger Indoor unit

Refrigerant flow, heating Liquid pipe Flow selector unit Discharge gas pipe Suction gas pipe Fan Pulse motor valve Heat exchanger Indoor unit

Rotary comp. vs. Scroll comp. Compression process Part load efficiency : Rotary has more advantage than Scroll!

Rotary comp. vs. Scroll comp. Operating pressure > Energy loss Required pressure

Rotary comp. vs. Scroll comp. Operating pressure = Required pressure High efficiency operation

Flex Variable Refrigerant Flow control scheme are get balanced out!

Double refrigerant control Flex Variable Refrigerant Flow control regulates aperture of the pulse motor valve and controls the cooling distribution control and the heating distribution control. Flex Variable Refrigerant Flow controls two refrigerant flow simultaneously!

Fast calculating vector controlled inverter All inverter control realizes finer control over operation to match the load on the system.

Consumption minimize control Heat discharge of condenser depends on indoor cooling + Heat absorption of evaporator depends on indoor heating = Consumption minimize control Minimum outdoor fan rotation 60rpm

Super efficient operation, straight cooling

Super efficient operation, straight cooling In cooling operation, all absorbed heat is thrown away ambient air!

Super efficient operation, simultaneous cooling / heating Surplus exhaust heat or surplus absorbed heat

Super efficient operation, simultaneous cooling / heating (Exhaust heat 10 = 8 + 2) = (Absorbed heat 10 = 5+ 5) If you operate those air conditioning pattern, you can enjoy the super efficient operation! *The actual operation may differ slightly from the above chart.

Auto change over operation image (cooling and heating) If you set the temperature of an air conditioner at 24.0 deg., the indoor temperature fluctuation is just +/ 1.5 deg.!

Line up, outdoor units HP Model name (MMY-) Cooling capacity (kw) Heating capacity (kw) Max. No. of indoor units HP Model name (MMY-) Cooling capacity (kw) Heating capacity (kw) Max. No. of indoor units 8 MAP0804FT8-E 22.4 25.0 13 10 MAP1004FT8-E 28.0 31.5 16 12 MAP1204FT8-E 33.5 37.5 20 14 MAP1404FT8-E 40.0 45.0 23 16 AP1614FT8-E 45.0 50.0 27 18 AP1814FT8-E 50.4 56.5 30 20 AP2014FT8-E 56.0 63.0 33 22 AP2214FT8-E 61.5 69.0 37 24 AP2414FT8-E 68.0 76.5 40 26 AP2614FT8-E 73.0 81.5 43 28 AP2814FT8-E 78.5 88.0 47 30 AP3014FT8-E 85.0 95.0 48 32 AP3214FT8-E 90.0 100.0 48 34 AP3414FT8-E 96.0 108.0 48 36 AP3614FT8-E 101.0 113.0 48 38 AP3814FT8-E 106.5 119.5 48 40 AP4014FT8-E 112.0 127.0 48 42 AP4214FT8-E 118.0 132.0 48 MMY MAP/AP***4FT8 E 380 415V 50Hz Europe model : Added model Total 18 line up

Line up, appearance 8 to 10HP 12 to 14HP 16 to 20HP 22 to 24HP 26 to 28HP 0.77 m2 0.94 m2 1.56 m2 1.73 m2 1.90 m2 30HP 32 to 34HP 36 to 38HP 40 to 42HP Current 12HP* 2.35 m2 2.52 m2 2.69 m2 2.86 m2 0.77 m2 *Current 12HP model (small chassis) will be continued to sell, it is only for stand alone unit. * Bottom figures show foot print

Specifications Equivalent HP New 8, 10HP (current 12HP) New 12, 14HP Appearance External dimensions Fan unit Connecting port diameter Anchor bolt pitch Height 1,830mm Width 990mm 1,210mm Depth 780mm Weight 272kg 349kg Motor output 1,000W Fan diameter φ740mm Suction gas side φ22.2mm* φ28.6mm Discharge gas side φ19.1mm Liquid side φ12.7mm 12HP:φ12.7mm 14HP:φ15.9mm Balance pipe φ9.5mm Width 700mm 920mm Depth 755mm 790mm Depth including attached legs *Current 12HP : suction gas side is φ28.6mm.

Specifications, outdoor operation range Heating range expanded from 15 deg. to 20 deg.! * Cooling range is from 10 degree to 43 degree as with SHRM.

Line up, indoor units 15 types, total 97 models 4-way air discharge cassette type Compact 4-way cassette type 2-way air discharge cassette type 1-way air discharge cassette type Concealed duct type Cooling capacity (HP) 2.2kW (0.8HP) MMU-AP0074MH-E MMU-AP0072WH MMU-AP0074YH-E MMD-AP0074BH-E 2.8kW (1.0HP) MMU-AP0092H MMU-AP0094MH-E MMU-AP0092WH MMU-AP0094YH-E MMD-AP0094BH-E 3.6kW (1.25HP) MMU-AP0122H MMU-AP0124MH-E MMU-AP0122WH MMU-AP0124YH-E MMD-AP0124BH-E 4.5kW (1.7HP) MMU-AP0152H MMU-AP0154MH-E MMU-AP0152WH MMU-AP0154SH-E MMD-AP0154BH-E 5.6kW (2.0HP) MMU-AP0182H MMU-AP0184MH-E MMU-AP0182WH MMU-AP0184SH-E MMD-AP0184BH-E 7.1kW (2.5HP) MMU-AP0242H MMU-AP0242WH MMU-AP0244SH-E MMD-AP0244BH-E 8.0kW (3.0HP) MMU-AP0272H MMU-AP0272WH MMD-AP0274BH-E 9.0kW (3.2HP) MMU-AP0302H MMU-AP0302WH MMD-AP0304BH-E 11.2kW (4.0HP) MMU-AP0362H MMU-AP0362WH MMD-AP0364BH-E 14.0kW (5.0HP) MMU-AP0482H MMU-AP0482WH MMD-AP0484BH-E 16.0kW (6.0HP) MMU-AP0562H MMU-AP0562WH MMD-AP0564BH-E 22.4kW (8.0HP) 28.0kW (10.0HP)

Line up, indoor units 15 types, total 97 models Concealed duct high static pressure type Slim duct type Ceiling type High wall type 2 series* High wall type 3 series Cooling capacity (HP) 2.2kW (0.8HP) MMD-AP0074SPH-E MMK-AP0074MH-E MMK-AP0073H 2.8kW (1.0HP) MMD-AP0094SPH-E MMK-AP0094MH-E MMK-AP0093H 3.6kW (1.25HP) MMD-AP0124SPH-E MMK-AP0124MH-E MMK-AP0123H 4.5kW (1.7HP) MMD-AP0154SPH-E MMC-AP0154H-E MMK-AP0153H 5.6kW (2.0HP) MMD-AP0184H-E MMD-AP0184SPH-E MMC-AP0184H-E MMK-AP0183H 7.1kW (2.5HP) MMD-AP0244H-E MMC-AP0244H-E MMK-AP0243H 8.0kW (3.0HP) MMD-AP0274H-E MMC-AP0274H-E 9.0kW (3.2HP) 11.2kW (4.0HP) MMD-AP0364H-E MMC-AP0364H-E 14.0kW (5.0HP) MMD-AP0484H-E MMC-AP0484H-E 16.0kW (6.0HP) 22.4kW (8.0HP) 28.0kW (10.0HP) MMD-AP0724H-E MMD-AP0964H-E

Line up, indoor units 15 types, total 97 models Floor standing concealed type Floor standing cabinet type Console type Floor standing type Air to air heat exchanger with DX-coil type Cooling capacity (HP) 2.2kW (0.8HP) MML-AP0074BH-E MML-AP0074H-E MML-AP0074NH-E 2.8kW (1.0HP) MML-AP0094BH-E MML-AP0094H-E MML-AP0094NH-E MMD-VN(K)502HEXE 3.6kW (1.25HP) MML-AP0124BH-E MML-AP0124H-E MML-AP0124NH-E 4.5kW (1.7HP) MML-AP0154BH-E MML-AP0154H-E MML-AP0154NH-E MMF-AP0154H-E MMD-VN(K)800HEXE 5.6kW (2.0HP) MML-AP0184BH-E MML-AP0184H-E MML-AP0184NH-E MMF-AP0184H-E MMD-VN(K)1002HEXE/2 7.1kW (2.5HP) MML-AP0244BH-E MML-AP0244H-E MMF-AP0244H-E 8.0kW (3.0HP) MMF-AP0274H-E 9.0kW (3.2HP) 11.2kW (4.0HP) 14.0kW (5.0HP) 16.0kW (6.0HP) MMF-AP0364H-E MMF-AP0484H-E MMF-AP0564H-E 22.4kW (8.0HP) 28.0kW (10.0HP)

Connectable indoor unit RBC AMT32E RBC AMT32E NRC 01HE Connect the air to air heat exchanger with DX coil to SHRM i

Specifications, branching joints for outdoor unit Suction gas pipe RBM-BT14FE RBM-BT24FE Less than 73kW (26HP) 73kW (26HP) or more Discharge gas pipe / Liquid pipe Balance pipe RBM-BT14FE / RBM-BT24FE The suction gas pipe of branching joint switched from previous T shape to Y shape.

Specifications, branching joints for outdoor unit Header unit Be sure to use the Y shape joint for suction gas pipe!

Specifications, flow selector unit RBM-Y1122FE RBM-Y1802FE RBM-Y2802FE Appearance Connectable indoor unit capacity Connectable indoor units* Below 11.2kW 11.2kW to below 18.0kW 18.0kW to 28.0kW or less 5 8 8 *Only group operation is possible with 1 (or 2) remote controller.

Specifications, in case of accident of flow selector unit SHRM i is able to keep on operation except an indoor unit with the broken FS unit!

Piping flexibility Possible to install the FS unit away! Flow selector unit piping length 15m 15m as maximum length by using the connection cable kit (RBC CBK15FE, sold separately).

Piping flexibility Height between CDU FCU 50m Height between FCU FCU 40m 11F 10F 9F 8F 7F 6F 5F 4F 3F 2F 1F

Piping flexibility Farthest equivalent length 195m Farthest pipe from 1 st branch 65m

High efficient EER & COP (100% load) HP Model name (MMY-) EER COP 8 MAP0804FT8-E 4.33 4.40 10 MAP1004FT8-E 3.85 4.20 12 MAP1204FT8-E 4.00 4.14 14 MAP1404FT8-E 3.54 3.54 16 AP1604FT8-E 4.35 4.40 18 AP1814FT8-E 4.05 4.29 20 AP2014FT8-E 3.85 4.20 22 AP2214FT8-E 3.93 4.17 24 AP2414FT8-E 3.66 3.79 HP Model name (MMY-) EER COP 26 AP2614FT8-E 3.71 3.75 28 AP2814FT8-E 3.47 3.46 30 AP3014FT8-E 3.89 4.22 32 AP3214FT8-E 3.92 4.16 34 AP3414FT8-E 3.71 3.90 36 AP3614FT8-E 3.75 3.86 38 AP3814FT8-E 3.56 3.63 40 AP4014FT8-E 3.62 3.69 42 AP4214FT8-E 3.48 3.46

High efficient EER & COP (50% part load) SHRM i 50% part load EER 50% part load COP 8 6.02 5.63 10 5.81 5.67 12 6.05 5.61 14 5.46 5.50 6.50 8HP 50% EER 12HP 50% COP 5.50 4.50 5.77 6.02 5.06 5.61 SHRM SHRM i SHRM SHRM i

High efficient EER & COP (100%, 50% part load) SHRM i

High efficient EER & COP, COP of heat recovery operation (image) Heat recovery operation is more efficient than individual operation of cooling and heating!

Applications (Complex bldg.) No FS unit FS unit FS unit Cooling only Kitchen Restaurant Office

Applications (Office bldg. 1) FS unit FS unit No FS unit Cooling only Meeting room Office Server room

Applications (Office bldg. 2) FS unit FS unit FS unit STOP South North The building where a room temperature difference is big! The building where a room temperature difference is big! The building where a room temperature difference is big! Office Office Office

Applications (Hotel) FS unit FS unit FS unit STOP Hotel with much individual operation needs! Hotel with much individual operation needs! Hotel with much individual operation needs! Room 1 Room 2 Room 3

Connectable wired remote controllers Application Name Model Appearance Lite-Vision plus remote controller RBC-AMS51E-ES RBC-AMS51E-EN Standard remote controller RBC-AMT32E Wired Remote controller with weekly timer RBC-AMS41E Simple wired remote controller RBC-AS21E2 Remote sensor TCB-TC21LE2

Connectable wireless remote controllers Application Name Model Appearance For 4-way air discharge cassette RBC-AX32U(W)-E RBC-AX32U(WS)-E Wireless For 2-way air discharge cassette For Ceiling, 1-way air discharge cassette For all indoor units RBC-AX32UW(W)-E RBC-AX32CE2 Stand alone receiver TCB-AX32E2

Connectable central controllers Application Name Model Appearance ON-OFF controller TCB-CC163TLE2 Central Central remote controller TCB-SC642TLE2 Schedule timer TCB-EXS21TLE

Connectable BMS controllers Application Name Model Appearance Touch-screen controller BMS-TP0641ACE/PWE BMS-TP5121ACE/PWE BMS Smart manager BMS-SM1280HTLE Smart manager with data analyzer BMS-SM1280ETLE <Graph chart sample by data analyzer>

Connectable open network Application Function Model Appearance Intelligent Server BMS-LSV6E Open network BACnet R : ANSI/ASHRAE 135 1995, A data Communication Protocol for Building Automation and Control Networks. BACnet Server Software BMS-STBN08E Relay Interface BMS-IFLSV4E LonWORKS R : Registered trademark Echelon corporation LN Interface TCB-IFLN642TLE Modbus R is a registered trademark of Schneider Modbus Interface TCB-IFMB640TLE

Connectable optional PC boards Application Name Model Appearance Power peak-cut control TCB-PCDM4E Outdoor unit Operation / Error output display Compressor operation output control Operation rate display control TCB-PCIN4E Snowfall fan control External master ON/OFF control Night operation (sound reduction) control TCB-PCMO4E Indoor unit Remote location ON/OFF control box TCB-IFCB-4E2

Your building appreciates in value by SHRM i!