Steam Distribution. Installation Manual. Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD.

Similar documents
STEAM DISTRIBUTORS ASD / BSD / CSD. Installation Manual C

READ AND SAVE THESE INSTRUCTIONS

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

Help. Help Software Tutorial. Building a Load Sizing Project with an NH-EL Humidifier and CSD Distributor.

READ AND SAVE THESE INSTRUCTIONS

SETC Outdoor. Supplemental Installation and Spare Parts Manual

NHRS Series RESISTIVE ELEMENT STEAM HUMIDIFIER. Engineering Manual. Manual No. H

Help. Help Software Tutorial. Building a Load Sizing Project with an SETC Humidifier and a mini SAM-e Distributor

READ AND SAVE THESE INSTRUCTIONS

Installation, Operation, Maintenance and Troubleshooting Guide

Installation and Operation Guide

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

INSTY-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

RH2+ Installation and Operation Manual

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

CUFFED FAST-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

NH Series Electric Steam Humidifiers

NH Series. Installation and Operation Manual

MES2. Installation and Operation Manual

Installation, Operation, Maintenance, Spare Parts, and Exploded Views Guide

Compressed Air Dryer

SE Series. Installation and Operation Manual

NH Series. Installation and Operation Manual

Drain Cooler Water tempering device

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

Design Criteria. Installation

SAM-e - Short Absorption Manifold Submittal Drawings

Condair SETC. Steam Exchange Humidifier

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Quick Start Installation Guide

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

CONTACTING CONDUCTIVITY BOILER SENSORS Instruction Manual

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

Getting Rid of Scale. Nortec RS Series Steam humidifier with patented scale management. Humidification and Evaporative Cooling

SE Series. Installation and Operation Manual

Installation, Operation, Maintenance and Troubleshooting Guide

_C_EN_1612 INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Blower Pack Condair BP. Humidification and Evaporative Cooling

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

INSTALLATION MANUAL. Gas-fired Steam Humidifier Nortec GS. IMPORTANT! Read and save these instructions. This manual to be left with the equipment.

GETZ MANUFACTURING PART # CYLINDER DRYER

QAS-101 SERIES SINGLE CHANNEL CONTROLLERS

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

INSTY-PAC EXTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

Pressure Steam Humidifiers LS SERIES. humidity.com

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

INSTY-PAC INTERNAL MOUNT WELDED MULTIPLE TUBE ASSEMBLY

AG Series Electric Heaters

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

IMPORTANT! Read and save these instructions. This manual to be left with the equipment.

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

TrueClean ToteCleaner

GS Series. Installation and Operation Manual

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

MN908 No. 282C Replaces 282B LB7013

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

MODEL CDB8 INSTALLATION INSTRUCTIONS

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

MS-600 DESICCANT DEHUMIDIFIER

Insty-Pac Steam Humidifiers

Compact Equipment Warranty Policy

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

HOT DOG STEAMER Instruction Manual Models: 8007 & 8012

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

Blade Series Heat Exchanger Operation and Installation

Classic & Deluxe Pants Press SPP-0669 SPP-0670

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

TITAN FLOW CONTROL, INC.

Users Manual. LAURUS Systems, Inc. - Ph: Fax:

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

SANI-VAC MODEL #750 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL. & WEAR EYE PROTECTION

RCM-C Vinyl Cleaner. Part List: Operation conditions:

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

SKR series Steam Humidifier Kit N (Patent Pending)

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

PROOF BOX (All SD,DD, and TD 99 Models)

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Air Pump Up to 800 gallons

Electric Duct Heaters

Cincinnati, OH USA

Owner's Manual Paramount 65X GRAPHIC LAMINATION PRODUCTS

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

ES Series Electric Humidifier

Model/Sprinkler Identification Numbers

Technical Data. Installation

The Series LFII (TY3596) Residential

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Clean Steam Generators

TrueClean ToteCleaner

Transcription:

Important: Read and save these instructions. This guide to be left with equipment owner. Steam Distribution Installation Manual Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD. 1506117-D 11 OCT 2018

Thank you for choosing Condair. INSTALLATION DATE (MM/DD/YYYY) MODEL # SERIAL SERIAL # CYLINDER CYLINDER # Proprietary Notice This document and the information disclosed herein are proprietary data of Condair Ltd. Neither this document nor the information contained herein shall be reproduced, used, or disclosed to others without the written authorization of Condair Ltd., except to the extent required for installation or maintenance of recipient s equipment. Liability Notice Condair does not accept any liability for installations of humidity equipment installed by unqualified personnel or the use of parts/components/equipment that are not authorized or approved by Condair. Copyright Notice Condair Ltd. All rights reserved.

Contents 2 Installation 2 Receiving and Unpacking 2 Pre-Installation 2 Steam Line Installation 3 Condensate Return Guidelines for Main Steam Lines 4 Distributor Mounting 10 Spare Parts 11 Warranty

Installation Receiving and Unpacking Equipment Check packing slip to ensure ALL material has been delivered. All material shortages are to be reported to Condair within 48 hours from receipt of goods. Condair assumes no responsibility for any material shortages beyond this point. Inspect shipping boxes for damage and note on shipping waybill accordingly. After unpacking, inspect equipment for damage and if damage is found, notify the shipper promptly. All Condair products are shipped on an F.O.B. factory basis. Any and all damage, breakage, or loss claims are to be made directly to the shipping company. Each distributor is provided with: installation manual, one hose cuff, and two hose clamps. Pre-Installation Check Ensure the total capacity of the humidifier is not higher than the allowable maximum steam capacity of the distributors used. ASD 10: 22 lbs/hr (10 kg/hr) ASD: 25 lbs/hr (11 kg/hr) BSD: 35 lbs/hr (16 kg/hr) CSD: 115 lbs/hr (53 kg/hr) RSD: 10lbs/hr (4.5 kg/hr) SSD: 10 lbs/hr (4.5 kg/hr) Steam Line Installation Condair steam hose should only be used on short steam runs below 10 feet. Ensure that no condensate produced in the steam line will remain trapped. Steam naturally flows upward and condensate naturally flows downward. See material recommended for use in the chart below. To eliminate the metal corrosion, Condair does not recommend the use of steel piping. Consult the following pages for step by step distributor installation starting with Figure 1. Consult the charts below for steam and condensate sizing guidelines when using steam distributors. Steam Line Distribution Installation Manual 2

Table 1: Steam Line Material Steam Hose Copper Tube Stainless Steel Tube Short run < 10 feet (3 m) Long run > 10 feet (3 m) DI/RO Water Load Table 2: Recommended Material and Size for Steam Run Steam Run lb/hr kg/hr ft m Steam Line Material Steam Line Description 0-30 0-13 0-10 0-3 Copper Tube ¾ MED-L Tubing (7/8 O.D) 0-30 0-13 10+ 3+ Copper Tube 1 MED-L Tubing (1 1/8 O.D) 0-30 0-13 0-10 0-3 Stainless Steel Tube 7/8 Tube x 0.049 Thick 0-30 0-13 10+ 3+ Stainless Steel Tube 1 1/8 Tube x 0.49 Thick 30-100 13-45 0-20 0-6 Copper Tube 1 ½ MED-L Tubing (1 5/8 O.D) 30-100 13-45 20+ 6+ Copper Tube 2 MED-L Tubing (2 1/8 O.D.) 30-100 13-45 0-20 0-6 Stainless Steel Tube 1 ¾ Tube x 0.065 Thick 30-100 13-45 20+ 6+ Stainless Steel Tube 2 Tube x 0.065 Thick Please note that options shown in bold-italic font require that reducers be used at both ends. These extra-large sizes are to allow for better condensation removal in long steam runs. These sizes will not permit you to use hose coupling to connect yourself to either humidifier or distributors. Table 3: Recommended Condensate Line at Distributor(s) Dispersion Method Condensate Hose Copper Tube Stainless Steel Tube 1 x Steam Distributor 3/8 Condair 1328840 ¼ MED-L Tubing (3/8 O.D.) 3/8 Tube 0.049 thick 3 x Steam Distributor 3/8 Condair 1328840 ½ MED-L Tubing (7/8 O.D.) 5/8 Tube 0.049 thick * When using more than one distributor, the condensate line should be trapped before joined together. 3 Steam Line Distribution Installation Manual

Condensate Return Guidelines for Main Steam Lines Use vertical condensate leg of distributor only. Do not over-tighten clamp. Condensate traps on steam mains must be located at all low points in the system, at each elevation change and or directional change. Horizontal runs of steam must rise 2 per foot (10 ) when flow is going upwards away from condensate trap, and fall ½ per foot (2 ) when flow is going downwards towards a condensate trap. In a horizontal run of the steam main, condensate traps must be located at regular intervals of 20 feet. The condensate trap itself is a section of piping connected to the bottom of the main. A full size tee must be used to create a condensate trap to allow the condensate to fall away from the steam flow. Vertical drop of the condensate trap should be 1.5 times the diameter of the steam main but no less than 12. A P-trap should be installed at the bottom of the condensate trap. The center to center trap height should be 2 greater than duct static pressure. All distributors must be individually trapped. Figure 1: Drain Tee Steam Line Distribution Installation Manual 4

5 Steam Line Distribution Installation Manual Figure 2: Distributor Mounting

Figure 3: Vertical Airflow Steam Line Distribution Installation Manual 6

Always align distributor holes so that steam is discharged upwards to ensure condensate will remain in the distributor. X Min. H Min. ASD 3 (76 mm) 8 (203 mm) BSD 4 (102 mm) 10 (254 mm) CSD 5 (127 mm) 14 (356 mm) RSD 3 (76 mm) 8 (203 mm) SSD* 3 (76 mm) 8 (203 mm) * SSD distributors can only be installed with upward airflow in vertical duct applications. Refer to C2 on the next page. ASD BSD CSD Ф 1.5 (38 mm) Ф 1.5 (38 mm) Ф 2.0 (51 mm) A Min. B Min. ASD 5 3 BSD 6 4 CSD 9 5 7 Steam Line Distribution Installation Manual Figure 4: Horizontal Airflow

Figure 5: Vertical Airflow * SSD distributors can only be installed with upward airflow in vertical duct applications. WARNING These installation guidelines apply for duct velocities under 2000 ft/min (610 m/min), please consult factory for higher velocities. Please make sure no obstacles (elbow, filter, or diffuser) are located after the distributor in the direction of the airflow closer than the absorption distance calculated for your application. Unless you know the exact absorption distance required for the steam absorption into the air steam, the distributor should be located at least 8-10 ft (2-3 m) away from any obstacle it may condense on (elbow, diffuser, filter, etc.). Steam Line Distribution Installation Manual 8

Figure 6: Distributor Mounting Horizontal & Vertical Flow Figure 7: Distributor Mounting 9 Steam Line Distribution Installation Manual

Figure 8: Spare Parts Steam Line Distribution Installation Manual 10

Warranty Condair Inc. and/or Condair Ltd. (hereinafter collectively referred to as THE COMPANY), warrant for a period of two years after installation or 30 months from manufacturer s ship date, whichever date is earlier, that THE COMPANY s manufactured and assembled products, not otherwise expressly warranted, are free from defects in material and workmanship. No warranty is made against corrosion, deterioration, or suitability of substituted materials used as a result of compliance with government regulations. THE COMPANY s obligations and liabilities under this warranty are limited to furnishing replacement parts to the customer, F.O.B. THE COMPANY s factory, providing the defective part(s) is returned freight prepaid by the customer. Parts used for repairs are warranted for the balance of the term of the warranty on the original humidifier or 90 days, whichever is longer. The warranties set forth herein are in lieu of all other warranties expressed or implied by law. No liability whatsoever shall be attached to THE COMPANY until said products have been paid for in full and then said liability shall be limited to the original purchase price for the product. Any further warranty must be in writing, signed by an officer of THE COMPANY. THE COMPANY s limited warranty on accessories, not of the companies manufacture, such as controls, humidistats, pumps, etc. is limited to the warranty of the original equipment manufacturer from date of original shipment of humidifier. THE COMPANY makes no warranty and assumes no liability unless the equipment is installed in strict accordance with a copy of the catalog and installation manual in effect at the date of purchase and by a contractor approved by THE COMPANY to install such equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for consequential damage or damage resulting directly from misapplication, incorrect sizing or lack of proper maintenance of the equipment. THE COMPANY makes no warranty and assumes no liability whatsoever for damage resulting from freezing of the humidifier, supply lines, drain lines, or steam distribution systems. THE COMPANY retains the right to change the design, specification and performance criteria of its products without notice or obligation 11 Steam Line Distribution Installation Manual