FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

Similar documents
FACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1

PROCESS AUTOMATION. Instruction manual. Fieldbus Terminators F*-FT-EX1.I.IEC F*-FT-EX1.D.IEC

Vibracon LVL-A* Level limit switch for liquids, compact design

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

MANUAL Overflow sensor NVF-104/34-PF

MANUAL Oil Level Sensor

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUAL / MANUALE

FACTORY AUTOMATION EXPERIENCE HYGIENIC DESIGN SENSORS FOR THE FOOD AND BEVERAGE INDUSTRY

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

SYSTEMS PRODUCT OVERVIEW

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

TECHNICAL WHITE PAPER AUTOMATIC WARNING DEVICES FOR LIGHT LIQUID SEPARATORS

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

FACTORY AUTOMATION SENSE WITH SIMPLICITY AND CONFIDENCE PHOTOELECTRIC FIBER AMPLIFIER SU18 AND SU19 SERIES

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Technical Data. General specifications. Rated operating distance s n 5 mm

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

Two global companies, one solution.

PROCESS AUTOMATION TIME TO RELAX ADVANCED DIAGNOSTICS EXPERT SYSTEM AT WORK

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

SensaGuard TM Integrated Latch Installation Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SCHMIDT LED Measured Value Display MD Instructions for Use

PROCESS AUTOMATION PROGRAMMING TREE 6000 SERIES PURGE/PRESSURIZATION SYSTEM

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. Dimensions

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

FACTORY AUTOMATION SENSE WITH SIMPLICITY FIBER OPTIC SENSORS AND FIBER OPTIC CABLES

Retroreflective sensor with polarization filter

Pepperl+Fuchs GmbH Lilienthalstrasse Mannheim Germany

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Operating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.

Technical Data. Dimensions

custom cabinets and junction boxes

PEPPERL+FUCHS GmbH

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

Liquiphant T FTL20H. Technical Information

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

1592P01. for liquids in piping DN

Retroreflective sensor with polarization filter

FSW300 Series Flow Switch

Technical Data. Dimensions

Technical Data. Dimensions

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

WHG. RoHS. Compliant. Edition February All specifications are subject to change without notice. ( )

D5100 Industrial Differential Pressure Transducer

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Tubular Optical Sensors. BOS S18 Economical Series Applications. Description. Features

Multifunctional Gate Box MGB. More than safety.


InductIve SenSorS 2018

Original operating instructions Safety switch with guard locking AC901S AC902S

Operating instructions

Twin radial blower DRG 730

Safety. Detection. Control. SAFETY INTERFACES. Safety Interfaces and Relays. Product catalogue. Issue 1

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

MTRA-FSP Level Control Relay. Installation & Operation Manual

operational excellence Solutions for

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

Assembly. Connection overflow sensor. Connection fat level sensor OFF ON

Manual Power relay SR853

Vacuum generators VADM/VADMI

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA18CAN/CAF...

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA30CAN/CAF...

Instructions For Use ENG. LED Magnifier Lamp

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Vacuum suction nozzle OVEM-...-1P/1N

Inductive slot sensor

Flow switch. Operating Manual. English manual page Page 1 of 15 Fax:

D5100 Industrial Differential Pressure Transducer

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

PHOTOVOLTAIC HEAT CONTROLER PVHC 2.01 USER MANUAL

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Datasheet - MZM 100 ST2-1P2PWREM-A

CARLO GAVAZZI Automation Components. CA18/30 CAN/CAF - Capacitive Sensors

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Datasheet - MZM 100 ST-SD2PREM-A

Vacuum generators VADM/VADMI

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

L / -014L / -015L

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Datasheet - MZM 100 B ST2-SD2PREM-A

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

HLS-2C Active Hearing Loop Panel

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

Transcription:

FACTORY AUTOMATION Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

Part. No. 202415 / DOCT-1310 / 05. june 2007

1 Sensor description............................................... 5 1.1 Basic features............................................................ 5 1.2 PLC input set/reset........................................................7 1.3 Display LEDs............................................................. 8 1.4 "Enhanced immunity" version.............................................. 8 2 Technical data................................................... 9 2.1 Electrical and mechanical data..............................................9 2.2 Electrical connection.....................................................10 2.3 Dimensions.............................................................10 3 Accessories.................................................... 11 3.1 Mounting aid MHW 01....................................................11 3.2 Cable sockets...........................................................11 4 Notes.......................................................... 12 Used symbols This symbol warns the user of potential danger. Nonobservance may lead to personal injury or death and/or damage to property. Warning Attention This symbol warns the user of potential device failure. Nonobservance may lead to the complete failure of the device or other devices connected. This symbol calls attention to important notes.r Note 3

Security advice Warning This product must not be used in applications, where safety of persons depend on the correct device function. This product is not a safety device according to EC machinery directive. Notes These operating instructions refer to proper and intended use of this product. They must be read and observed by all persons making use of this product. This product is only able to fulfill the tasks for which it is designed if it is used in accordance with specifications of Pepperl+Fuchs. The warrantee offered by Pepperl+Fuchs for this product is null and void if the product is not used in accordance with the specifications of Pepperl+Fuchs. Changes to the devices or components and the use of defective or incomplete devices or components are not permitted. Repairs to devices or components may only be performed by Pepperl+Fuchs or authorized work shops. These work shops are responsible for acquiring the latest technical information about Pepperl+Fuchs devices and components.repair tasks made on the product that are not performed by Pepperl+Fuchs are not subject to influence on the part of Pepperl+Fuchs. Our liability is thus limited to repair tasks that are performed by Pepperl+Fuchs. The preceding information does not change information regarding warrantee and liability in the terms and conditions of sale and delivery of Pepperl+Fuchs. This device contains sub-assemblies that are electrostatically sensitive. Only qualified specialists may open the device to perform maintenance and repair tasks. Touching the components without protection involves the risk of dangerous electrostatic discharge, and must be avoided. Destruction of basic components caused by an electrostatic discharge voids the warrantee! Subject to technical modifications. Pepperl+Fuchs GmbH in D-68301 Mannheim maintains a quality assurance system certified according to ISO 9001. 4 ISO9001

Sensor description 1 Sensor description 1.1 Basic features The main feature of the inductive proximity switch NBB20-/NBN40-L2-E2B-C-V1 is the bistability of the switching output. The standard behaviour of an inductive proximity switch is such that the presence of an activator element (e.g. metal edge) activates the output. As soon as the activator element vacates the sensor detection area, the output returns to a passive state. The bistability of the output of the sensor described here causes the state of the output to change every time a new activator element is detected within the sensor detection area. Removing the activator element does not have an effect on the state of the output, however. Object in detection range 1 0 t Output 1 0 t Fig. 1.1: Output behaviour dependent on the presence of an activator element This output behaviour allows the sensor NBB20-/NBN40-L2-E2B-C-V1 to be used as a direct replacement for an electromechanical cross switch. motion direction Fig. 1.2: skid activator elements Skid measurement using an electromechanical cross switch cross switch 5

Sensor description The respective switching state of the sensor NBB20-/NBN40-L2-E2B-C-V1 is stored nonflush in the sensor at all times so that the last valid output state is made available when the sensor is activated again after disconnection from the power. The advantages of replacing the electromechanical cross switch with sensor NBB20-/NBN40- L2-E2B-C-V1 are: suitable for rapid handling systems non-contact, i.e. no mechanical wear no moving parts unintentional actuation by operating personnel not possible maintenance-free sensors easy to replace without subsequent readjustment motion direction skid sensor NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 activator elements Fig. 1.3: Skid measurement using sensor NBB20-/NBN40-L2-E2B-C-V1 6

Sensor description 1.2 PLC input set/reset The sensor has a function input which offers another way to change the output state of the sensor. When an input signal is created with the potential +U B, the output state of the sensor changes in the same way as when an activator element enters the sensor detection area.the switching state of the sensor can be set or reset specifically via a PLC without requiring a transport process. Object in detection range S n 1 0 t Output 1 0 t Set/Reset 1 Fig. 1.4: 0 Output behaviour dependent on the presence of an activator element and the activation of the PLC input t 1.3 Display LEDs A total of 4 extremely bright LEDs positioned on the corners allow the operator to visually check that the sensor is functioning correctly (2 green LEDs) and check the current switching state (2 yellow LEDs) from all sides and at a distance from the sensor. 1.4 "Enhanced immunity" version The inductive proximity switch NBB20-/NBN40-L2-E2B-C-V1 is largely immune to external magnetic fields generated by nearby electrical welding equipment. 7

Technical data 2 Technical data 2.1 Electrical and mechanical data 8 NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 GENERAL DATA Switching element function PNP, normally closed Sensing range s n 20 mm 40 mm Mounting flush nonflush Output polarity DC Guaranteed switching distance s a 0 to 16.2 mm 0 to 32.4 mm Reduction factor r Al 0.33 0.31 Reduction factor r Cu 0.31 0.3 Reduction factor r V2A 0.74 0.74 Reduction factor r Ms 0.41 0.31 Characteristic data Operating voltage U B 10... 30 V Switching frequency f 0... 50 Hz Hysteresis H typ. 5 % Reverse polarity protection protected Short circuit protection pulsing Voltage drop U d 3 V Rated value data Operating current I L 0... 200 ma Residual current I r 0... 1 ma No-load current I 0 25 ma Operating voltage indicator LED, green Switching state indicator LED, yellow Conformity with standards Standards IEC / EN 60947-5-2:2004 Ambient conditions Ambient temperature -25... 85 C (248... 358 K) Storage temperature -25... 85 C (248... 358 K) Mechanical data Connection type V1 connector plug Housing material PA 6 Grivory GVN-35H Front end PA 6 Grivory GVN-35H Protection class IP69K

Technical data 2.2 Electrical connection E2B I 1/BN 2/WH 4/BK 3/BU L+ S/R L- Fig. 2.1: Electrical connection NBB20-/NBN40-L2-E2B-C-V1 2.3 Dimensions LED ye LED gn LED ye 28 4 67 7 M12 x 1 LED gn 40 40 20 30 46 60 5.5 ø 5.5 Fig. 2.2: Dimensions NBB20-/NBN40-L2-E2B-C-V1 9

3 Accessories Accessories 3.1 Mounting aid MHW 01 Mounting aid MHW 01 is suitable for attaching sensor NBB20-/NBN40-L2-E2B-C-V1. 155 Y H 35 44 Fig. 3.1: Dimensions MHW 01 3.2 Cable sockets Our 4-pole cable sockets are suitable for the electrical connection of sensor NBB20-/NBN40- L2-E2B-C-V1 and are available in different lengths with various covering materials. Straight version: V1-G-2M-PVC V1-G-3M-PVC V1-G-5M-PVC V1-G-10M-PVC V1-G-2M-PUR V1-G-3M-PUR V1-G-5M-PUR V1-G-10M-PUR 10 Angled version: V1-G-2M-PVC V1-G-3M-PVC V1-G-5M-PVC V1-G-10M-PVC V1-G-2M-PUR V1-G-3M-PUR V1-G-5M-PUR V1-G-10M-PUR

4 Notes Notes 11

FACTORY AUTOMATION SENSING YOUR NEEDS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 44087 USA Tel. +1 330 4253555 E-mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Company Registration No. 199003130E Singapore 139942 Tel. +65 67799091 E-mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany TDOCT-1310_ENG 202415 06/2007