Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor

Similar documents
CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

DIVISION 21 FIRE SUPPRESSION FIRE SUPRESSION

F Cleaning In Place. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

Gas Station & C Store SECTION CWM Job No

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

Automatic Sprinklers

Plumbing Solutions for Agriculture and Irrigation Applications

WATER POWERED OSCILLATING MONITOR

Model F3-80 Dry K8.0 (115 metric) Standard-Response, Standard Spray Sprinklers

SECTION FIRE PROTECTION

more powerful than hand-held alternatives so they do a better job of cleaning and removing deposits.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

esfr dry pendent sprinkler Vk502 (k14.0)

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

MODEL: FA003U FA004U FA005P FA006P STANDARD SPRAY, STANDARD QUICK RESPONSE, 5 3 mm BULB TYPE, K5.6, 1/2" CONNECTING THREAD

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Automatic Sprinklers

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

Model F1 Residential Sprinklers for Design Density of.10 gpm/ft 2

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

SECTION FIRE-SUPPRESSION STANDPIPES

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

Sprinkler Identification Numbers

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

TECHNICAL. Series 18. Pump Packages

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

mirage standard response concealed pendent sprinkler vk492 (K5.6)

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

Model G5 Series Sprinkler Summary. Listings and Approvals. G4/G5 QR Gasket culus QR G4/G5 SR Gasket culus, FM SR G4/G5

Sprinkler Identification Number (SIN)

B. Related Sections: The following Sections contain requirements that relate to this Section.

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

The Series LFII (TY3596) Residential

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

BAND HEATERS component parts

esfr dry pendent sprinkler Vk501 (k14.0)

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

SECTION PLUMBING EQUIPMENT

DATASHEET HIGH VOLUME LONG RANGE FOAM MONITOR GPM

MODEL WALL MOUNT AUTOPSY STATION DOUBLE SINK

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

Steel Casework Acid Storage

WALL MOUNT AUTOPSY STATION CENTER SINK

esfr pendent sprinkler vk510 (k25.2)

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Standard Spray concealed horizontal sidewall sprinkler VK481

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

DUKE UNIVERSITY CONSTRUCTION STANDARDS

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

SECTION WET FIRE SPRINKLER SYSTEMS

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

sprinkler vk538 (K11.2)

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Storage Solutions. New Items Inside. High Capacity Cabinets Heavy Duty Shelf Cabinets Shop Desks Modular Mobile Cabinets Security Trucks

TMV45 & TMV80 Standard Thermostatic Mixing Valves

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

STANDARD/quick. Sprinkler 42o. August 8, 2011

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

HL45, HL80 Thermostatic High-Low Valves

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION DOMESTIC WATER PUMPS

CO ALARMS GAS DETECTION HYDRANT BOOSTERS MOUNTS PUMP SOLUTIONS SUPPRESSION SYSTEMS. /fireprotection

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Safety is more than just being careful: it

Transcription:

Firefighting Group Water Systems 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water

Flat Spray Nozzle Model No.7010 Size ½ to 1 NPT Flat Type The GPE tank cooling water spray nozzles are designed to produce wide angle flat spraying flows and are available in a wide range of bore sizes and materials. The 7000 series is ideally suited to the protection of storage tank shells and roofs and is widely used in process plant to protect equipment and structural members from the damaging effect of heat. The nozzle is also particularly effective in applications where a water screen is required to isolate a risk and to prevent the spread of fire or to protect escaping personnel from radiated heat. Minimizing the flow rate of spray nozzle: The minimum flow rate of each spray nozzle with any K-factor is determined with following equation: Flow (LPM) = K-Factor P =Minimum pressure = 1 BARG. (Recommended) The range of pressure = 1 to 6 BARG. 90

Directional Spray Nozzle Model No.7020 Medium Velocity Water spray Size ½ to1 NPT The Model 7020 spray nozzles are open (non-automatic) directional spray nozzles and are designed for use in water spray fixed systems for fire protection applications. They are external deflector type nozzles that discharge a uniformly filled cone of medium velocity water droplets. The 7020 Nozzles are effective in covering exposed vertical, horizontal, curved, and irregular shaped surfaces in a cooling spray to prevent excessive absorption of heat from an external fire and possible structural damage or spread of fire to the protected equipment. The Type 7020 nozzles are available in a wide variety of orifice sizes and spray angles (included angle of discharge) to provide versatility in system design. These spray nozzles are using in off-shore platforms, Refineries, Power Station, LPG & LNG Plants, Spherical Tanks Minimum Flow Rate of Spray Nozzle: The minimum flow rate of each spray nozzle with different K-Factor determined with following equation: Flow (Lpm) = K-Factor P =Minimum pressure = 1 Barg. (Recommended) The range of pressure = 1.0 to 5.0 Barg. Recommended Pressure 1.5 to 3.5 Barg. A= Spray Angle D =Spray Distance from wall side Theoretical Coverage Distance = (2 D) tan(a) B=Wet acoverage Distance = 0.8(2 D) tan(a) 91

Fire Hose Box and Hose Reel Model No. 7200 Water Proof Self-Standing / Wall Mounted Indoor / Outdoor GPE fire hose/hose reel box used to store fire hose and equipment for outdoor use in industrial applications. The Hose Storage Cabinet, constructed of carbon steel or coat galvanized metal with two coats red baked enamel. Stainless steel piano hinges with chrome plated door latches. 0.8-1.5 mm Carbon Steel or galvanized steel sheet. Empty shelves 13 wide with 3 / 4 lip 2 slope on roof Rain trough over doors Door reinforcement at front, top and bottom Doors overlap tub at hinge side Piano hinge on both doors Door lock (R.H. door only) Chrome plated handle with 2 point catch Louvers on each end under bottom shelf (optional-please specify) Inside lips (front side) 3 at top 1 ½ at bottom 1 at sides and bottom Two coats red baked enamel Ral 3020 To Specify: Free Standing/without legs Wall Mounted (with rear lugs top & bottom) Concrete Base Mounted (with grouting lugs at bottom) Support Mounted - legs packed separately 92

Wet Barrel Fire Hydrant Model 7400 Group The fire hydrants provided under this category are post type, Wet barrel, class A fire hydrants. Wet Barrel hydrants are available in different model as below: Hose Connection Pumper Connection Model No Size (in) Type Size (in) Type 7410 2 ½ Thread 4 Thread _ 7412 2 ½ Thread 5 Thread _ 7414 2 ½ Thread 4 Flanged _ 7416 2 ½ Thread 5 Flanged _ 7418 2 ½ Thread 4 Flanged With Single Arm 7420 2 ½ Thread 5 Flanged With Double Arm 7430 2 ½ Flanged 4 Thread _ 7432 2 ½ Flanged 5 Thread _ 7434 2 ½ Flanged 4 Flanged _ 7436 2 ½ Flanged 5 Flanged _ 7438 2 ½ Flanged 4 Flanged With Single Arm 7440 2 ½ Flanged 5 Flanged With Double Arm fire hydrant main valve is a Butterfly Valve type. The hydrant main valve and operating parts including valve seat, valve seat insert are of bronze. Hydrant body consists of two 2½ inch hose nozzle and pumper nozzle in three sizes 4, 4½, 5 inches in tow Flanged and Threaded Types. These types of hydrants are available with water monitors. 93

Dry Barrel Fire Hydrant Model 7500 Group The Fire hydrants provided under this category are post type. Dry barrel hydrants are available in different models as below: Features and Benefits: s fire hydrant main valve is a manual type. The hydrant main valve and operating parts including valve seat, valve seat insert are of bronze. Hydrant body consists of two 2½ inch hose nozzle and 4½ inch pumper nozzle, all with NFPA No. 194 standard Fire Hose Coupling Screw Threads. Hose Connection Pumper Connection Model No Size Size Type Type _ (in) (in) 7510 2 ½ Thread 4 Thread _ 7512 2 ½ Thread 5 Thread _ 7514 2 ½ Thread 4 Flanged _ 7516 2 ½ Thread 5 Flanged _ 7518 2 ½ Thread 4 Flanged With Single Arm 7520 2 ½ Thread 5 Flanged With Double Arm 7530 2 ½ Flanged 4 Thread _ 7532 2 ½ Flanged 5 Thread _ 7534 2 ½ Flanged 4 Flanged _ 7536 2 ½ Flanged 5 Flanged _ 7538 2 ½ Flanged 4 Flanged With Single Arm 7540 2 ½ Flanged 5 Flanged With Double Arm 94

Water Model No. 7700 Sizes 3 or 4 2 No. Swivel Joint Fixed Type Manual Operating The handle monitor comes with both a left/right and an up/down lock handle. To disengage lock(s), turn handle(s) counterclockwise. Move the tiller handle to direct the stream to the desired position. Turn lock handle(s) clockwise to engage lock. Corrosion resistant with brass construction; Unique configuration; Flow up to 1250 gpm; Compact -3 or 4 150# ANSI flange; Vertical movement 90 degrees above horizontal to 45 degrees below; Full, continuous 360 degree rotation; Rugged, stainless steel lock hardware;grease fittings for easy lubrication;durable Electro Statics finish. 95