KAIROS XP 2.5-1V / 2.5-1H

Similar documents
October Solar Thermal

D O M E S T I C Solar Thermal

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

S SOLAR RANGE

Solar heating systems

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

For latest prices and delivery to your door visit MyTub Ltd

Solar Thermal Energy

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

1 VICTRIX ZEUS Superior kw I features

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

Gasketed and brazed plate heat exchangers

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Exclusive Green E Condensing Wall-Hung Boilers

Discover our product portfolio! All around heating and solar thermal control technology.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Power X High Power Condensing Wall-Hung Boilers

Solar water heating system

SOLAR TECHNIQUE ATTACK SOLARTHERM, VAKUUMTHERM

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Power X High Power Condensing Wall-Hung Boilers

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Germany 44% Spain 9% Italy 9% France 8% Austria 7% Greece 6% Poland 2% Belgium 2% Portugal 2% Switzerland 2% Great Britain 2% Cyprus 2%

Components for solar heating systems

C B SOLARTHERMAL. Solar thermal systems

ACCUMULATION OF EUROPEAN CLASS

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Planning guide. (2010/09) en

T. +44 (0) E.

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

International Markets. Product Catalogue. complementary items

Aquamatic Instantaneous DHW production unit with integrated storage tank

INDIRECT SYSTEM FOR FROST LOCATIONS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

ModuSat TP. Energy. Heat Interface Units

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

SOLAR THERMAL SYSTEM. Product catalogue

product overview ProControl

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

WOLF VENTILATION SYSTEM PRICE LIST

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

ECOplus Solar Cylinder

Technical documentation Solar technology

Heat Accumulation. thermal stores hot water storage tanks. Energy-saving solutions

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Advance Split

Trade Product List 2013 BIOMASS ACCESSORIES

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

Metering systems 0548EN April 2014

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Installation, Operating and Servicing Instructions

VICTRIX Superior kw Export VICTRIX Superior kw X Export

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Installation, Operating and Servicing Instructions

maximise the sun s energy with warmflow solar Warmflow Solar

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

COMMERCIAL SOLAR SOLUTIONS

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

Industrial and collective. With coil exchanger. Technical data. Initial heat-up. surface area. Exchanger. Exchanger capacity.

2011 Solar Thermal Water Heating Solutions

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

TERMO Combi Cylinder TECHNICAL INFORMATION

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

Solar thermal domestic hot water system

Solar technology. Technical documentation. Flat-plate collectors CFK-1/TopSonF3-1/F3-Q Vacuum tube collector CRK Swimming pool absorber

SOLAR HEATING SYSTEMS

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Systems for central heating

ThermoDual Domestic hot water charging system

The mechatronics of EVE 05

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

STORAGE WATER HEATERS

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

Transcription:

FLAT SOLAR COLLECTOR KAIROS XP 2.5-V / 2.5-H Solar collector for forced circulation PERFORMANCES Kairos XP 2.5- has a serpentine absorber that makes it suitable for big systems; The blue selective surface treatment forgives very high performances with the 95% absorbtion and only 5% reflection; The collectors increased surface gives the possibilty to produce even more domestic hot water; The laser welding technology guarantees a very smooth absorbing surface, maximizing the exploitation of the solar energy; The back and lateral insulation, with very low conductivity (only 0.035 W/mK), ensures higher efficiency; Thanks to the high transparent glazed covering, with an internal microprismatic treatment, the reflections are reduced; TECHNICAL DATA KAIROS XP 2.5-V Empty mass Kg 46 Working pressure bar 6 Collector pipe diameter mm 8 Amount of collector liquid l 2, Absorption % 95 Emission % 5 Aperture surface m 2 2,26 Absorbent surface m 2 2,24 Specific thermic capacity kj/k 5,32 η 0 0,8* k W/m 2 K 3,3* k 2 W/m 2 K 2 0,06* T stagnation C 98 * data refers to the aperture area CODE 3020058 Up to 0 collectors Up to 5 collectors 4 /

FLAT SOLAR COLLECTOR DESIGN AND TECHNOLOGY Kairos XP 2.5- offers a very enjoyble design in its category, thanks to the accurate study of the lines, and of the external shape; The new o-ring connection allows a very quick installation, even eliminating the risk to damage the hydraulic connection kit; Kairos XP 2.5- is availbel in two versions that allow vertical and horizontal installation; Additional accessories allow the built-in installation; QUALITY Kairos Thermo HF is made up with the best material available: the copper hydraulic circuit and the anodized aluminium chassis guarantee high reliabilty, corrosion proof and very long life cycle; The special tempered glass with low content iron assures very high protection against the hail, and against the collector s loading; The technopolymer angle, that integrates the condensate exhaust and the flanged manifold outlet, ensures a more precise production process; With the solar key mark and the test report according EN 2975-2, the compliance with the international standard is certified; TECHNICAL DATA KAIROS XP 2.5-H Efficiency Solar collector efficiency curve,0 Ppeak=.832 W 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0, 0,0 0,00 0,0 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,0 (T collector liquid average -T environment )/G K/(W/m 2 ) G = 000 W/m 2 Empty mass Kg 46 Working pressure bar 6 Collector pipe diameter mm 8 Amount of collector liquid l 2,5 Absorption % 95 Emission % 5 Aperture surface m 2 2,26 Absorbent surface m 2 2,23 Specific thermic capacity kj/k 7,98 η 0 0,8* k W/m 2 K 3,02* k 2 W/m 2 K 2 0,07* T stagnation C 93 * data refers to the aperture area CODE 3020057 8 Up to 0 collectors Up to 5 collectors / 5

FLAT SOLAR COLLECTOR KAIROS CF 2.0 Solar collector for forced circulation Absorber with highly selective treatment to titanium oxides (95% absorption 5% emission) Hail-proof anti-reflective glass Hydraulic circuit with copper pipes Harp geometry and continuous ultrasound welding Designed and sized for functioning in systems with forced circulation Can be inclined between 30 and 60 Test report according to en 2975 Efficiency Solar collector efficiency curve,0 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0, 0,0 0,00 0,0 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,0 T collector liquid average -T room /G K/(W/m 2 ) TECHNICAL DATA KAIROS CF 2.0 Empty weight kg 35 Working pressure bar 6 Collector pipe diameter mm 8 Amount of collector liquid l,0 Absorption % 95 Emission % 5 Aperture surface m²,82 Absorbent surface m²,74 Specific heat capacity kj/k 3 η0 0,74* k W/m²K 3,43* k2 W/m²K² 0,008* stagnation T C 82,3 * data referring to the aperture area CODE 3020055 6 /

VACUUM TUBE SOLAR COLLECTOR KAIROS VT 20 Solar collector for forced circulation Aluminium blue selective and adjustable absorber with concentric tube Very high transparency borosilicate vaccum single glass Structure with insulated technopolymer Connections with idler screw nut Integrated solar probe hole Vertical, horizontal, ground and sloped roof installation Efficiency Solar collector efficiency curve,0 Ppeak=.740 W 0,9 0,8 0,7 0,6 0,5 0,4 0,3 0,2 0, 0,0 0,00 0,0 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,0 (T collector liquid average -T environment )/G K/(W/m 2 ) G = 000 W/m 2 40 mm 90 mm TECHNICAL DATA SOLAR COLLECTOR KAIROS VT 20 Empty mass kg 68 Working pressure bar 6 Amount of collector liquid lt 5.7 Absorption % 92 Emission % 8 Aperture surface m 2 2,2 Absorbent surface m 2 2,0 η0 0.82* k W/m 2 K 2.82* k2 W/m 2 K 2 0.0047* T stagnation C 206, 840 mm Rule of composition of the line with temperature probe: a row of n manifolds consists of a solar collector Kairos VT 20 B and n- solar collectors Kairos VT 20 E. * data refers to the aperture area KAIROS VT 20 B KAIROS VT 20 E CODE 3023497 302022 Up to 6 collectors Up to 3 collectors / 7

COMPOSITION OF THE ROWS OF SOLAR COLLECTORS Efficient products for the satisfaction of the user,easiness and flexibility of installation to help the installer: this perfect coupling characterizes our solar collectors and is one of the reason why Ariston s solar products are choosen every year from millions of customer around the world. The collectors of Ariston solar range can be installed on the ground or flat roof, on sloped roof and in-roof (Kairos XP 2.5- V only). For any of the above mentioned installation possibility, the following tables are designed to help the installer and the end user choosing the correct installation and hydraulic accessories for any kind of solar collector. Example of ground installation Example of sloped roof installation Example of in-roof installation (only Kairos XP 2.5 V) KAIROS CF 2.0 2 3 4 5 6 TT TR Description Code TT TR TT TR TT TR TT TR TT TR TT TR Hydraulic fittings kit for collector forced circ.cf 302407 Hydraulic fittings kit for CF extension 302408 2 2 3 3 4 4 5 5 Roof frame for collector forced circulation CF 302404 Roof frame for 2 collectors forced circulation CF 302405 Extension roof frame for 2 collectors forced circulation CF 302406 2 2 Horizontal bar CF 2.0 3024249 2 3 4 5 6 Triangle 302403 2 2 3 4 5 6 8 /

KAIROS XP 2.5-V 2 3 4 5 6 7 8 9 0 TT TR IN IN² Description Code TT TR IN TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² TT TR IN IN² KAIROS XP 2.5- V 3020046 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 0 6 6 6 2 7 7 7 4 8 8 8 6 9 9 9 8 0 0 0 20 Hydraulic connection set collector Hydraulic connection set collector ext. 3024093 2 2 2 2 2 2 2 2 2 3024094 2 2 2 2 4 3 3 3 6 4 4 4 8 5 5 5 0 6 6 6 2 7 7 7 4 8 8 8 6 9 9 9 8 Horizontal Bars 302404 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 Triangle 302403 2 2 3 4 5 6 7 8 9 0 Inox Fixing Straps* 30242 2 3 4 5 6 7 8 9 0 In-roof kit ( collector) In-roof kit (2 collectors) In-roof kit (additional collector) 2nd row in-roof kit (2 collectors) 2nd row in-roof kit (additional collector) 372434 372428 372429 2 2 3 3 4 4 5 5 6 6 7 7 8 8 372430 TT TR IN IN² 37243 2 3 4 5 6 7 8 KAIROS XP 2.5-H 2 3 4 5 6 7 8 9 0 TT TR Description Code TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR TT TR KAIROS XP 2.5- H 3020047 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 Connection set coll 3024093 Connect set additional coll XP 3024094 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 Horizontal bars (XP 2.5- H) 302406 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 Triangle (XP 2.5- H) 302405 2 3 4 5 6 7 8 9 0 Inox fixing straps* (pair) 30242 2 3 4 5 6 7 8 9 0 * special fixing frame for sloped roof for xp collector Description Code Bent tile fixing brackets (pair) 30243 Flat tile fixing brackets (pair) 30244 Slate tile fixing brackets (pair) 3024083 Undulating roof fixing screws (pair) 30245 Wooden roof fixing screws (pair) 30246 / 9

KAIROS VT 20 TT TO OO TR 2 3 4 5 6 Description Code TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR TT TO OO TR Hydraulic kit for KAIROS VT extension 2043886 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 Horizontal bar 3024250 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6 KAIROS VT roof bracket kit 302447 2 2 2 3 3 3 4 4 4 5 5 5 5 6 6 6 Triangle 302425 2 3 4 5 6 Safety bracket 3024254 2 3 4 5 6 MINIMUM EXTERNAL TEMPERATURE / PERCENTAGE Natural Circulation kit Forced Circulation kit Supplementary CF kit connections -3 /0% -7 /20% -4 /30% -23 /40% -32 /50% water glycol water glycol water glycol water glycol water glycol MIXTURE CONTENT l 50/ 8 2 5 5 5 5 - - - - 20 l 200/ 22.5 2.5 20 5 7.5 7.5 - - - - 25 l 200/2 22.5 2.5 20 5 7.5 7.5 - - - - 25 l 300/2 22.5 2.5 20 5 7.5 7.5 - - - - 25 l 200/2 CF 2 0.5 2.5 9 4 8 5 6.5 6.5 3 l 200/2 CF2 8 7 2 6.5 2.5 5.5 3.5 4.5 4.5 9 l 300/2 CF 6 2 4.5 3.5 2.5 5.5 7 9 9 8 l 300/2 CF2 6 2 4.5 3.5 2.5 5.5 7 9 9 8 l 400/3 CF2 20.5 2.5 8.5 4.5 6 7 4 9.5.5 23 l 500/4 CF2 25 3 22.5 5.5 9.5 8.5 7 4 4 28 8-5 m_pipe + + 0 + + 0 + + + + + + + 8-0 m_pipe + 2 + 0 +.5 + 0.5 +.5 + + + + + + 2 8-20 m_pipe + 3.5 + 0.5 + 3 + + 3 + + 2.5 +.5 + 2 + 2 + 4 8-30 m_pipe + 5.5 + 0.5 + 5 + + 4 + 2 + 3.5 + 2.5 + 3 + 3 + 6 22-5 m_pipe + 2 + 0 +.5 + 0.5 +.5 + 0.5 + + + + + 2 22-0 m_pipe + 2.5 + 0.5 + 2.5 + 0.5 + 2 + + 2 + +.5 +.5 + 3 22-20 m_pipe + 5.5 + 0.5 + 5 + + 4 + 2 + 3.5 + 2.5 + 3 + 3 + 6 22-30 m_pipe + 8 + + 7 + 2 + 6 + 3 + 5.5 + 3.5 + 4.5 + 4.5 + 9 20 /

ACCESSORIES AND COMPONENTS / 2

Solar Accessories Solar system management accessories and devices Code Sensys, modulating system manager (wired) - Remote control of all boiler functions through the BUS Bridgenet protocol - User-Friendly Setting/Configuration of system parameters - thermoregulation - Display of solar system working (if connected) - Display of energy reports (kwh), solar energy production, CO2 savings, storaged DHW - Modulating sensor for detecting of the room temperature - User-friendly daily and weekly scheduling of central heating - User-friendly daily and weekly scheduling of domestic hot water (only in case of only-heating boiler coupled to a tank) 338585 IT-EN-FR-ES-PT 33863 TK-RUS- GR-HR- SRB 33865 PL-CZ-HU-RO Solar Manager IZY Control unit equipped with liquid crystal display that can show and manage up to 0 types of solar plants. Four sensor inputs Pt000, three relay outputs and two PWM to control variable speed circulators. The controller display the temperatures measured by the probes, diagnostic on-screen function test system, and anti-freeze function. Free Vbus and BACnet compatibility. Compatible with PRO datalogger DL2, DL3 DATALOGGER PRO INTERFACE LAN-SOLAR MANAGER PRO, PRO MODULE ALARM PROTECTION THE SURGE. Dimensions: 0 x 66 x 47 mm 3024340 Additional DHW solar probe Cylinder probe with diameter of 6 mm Pt000 Class B DIN with metre of blue cable suitable for measuring cylinder temperatures; range -50 C/+0 C. Compatible with Elios 25. 3024274 Additional collector solar probe Cylinder probe with diameter of 6 mm Pt000 Class B DIN with metre of grey cable suitable for measuring collector temperatures; range -50 C/+200 C. Compatible with Elios 25. Copper well and probe-holder clamp included. 3024273 Digital thermostat Device with input for probe and output for the actuation of a high voltage load at 250 V like a diverter valve with 2 or 3 wires. The three digit display allows to view the temperatures and the setting of the functioning parameters. Supplied cylindrical probe with diameter of 6 mm Ptc000 with.5 metres of cable. Dimensions: 79 x 5 x 42 mm. 800232 Electrical resistance Flanged resistance kit for.5 kw single-phase natural circulation systems and 220 V power supply. Includes flange, magnesium anode, thermostat and small cap. Suitable for Kairos Thermo Direct (all versions) and Kairos Thermo HF (all versions). 07069 Enamelled electrical resistance Flanged resistance kit for 2 kw single-phase natural circulation systems and 220 V power supply. Includes flange, magnesium anode, thermostat and small cap. Suitable for Kairos Thermo Direct (all versions) and Kairos Thermo HF (all versions). Safety group Pre-assembled group including safety valve, automatic air release valve and manometer 3024272 2053830 heating return probe S4 302475 22 /

Hydraulic devices and accessories Code Digital Solar Pump Group Pumping station for forced circulation plants, equipped with a safety, regulation and rinse unit, digital pressure and temperature sensors,electronic control board provided with a collector probe and two tank probes. Hydraulic connections in 8 mm or in 3/4 flat seal version. Dimensions: 275 x 480 mm. flow - return axles distance 25 mm.nb: system interface SENSYS to be ordered separately 338905 Solar pump group 25-70 Pumping station for forced circulation systems, equipped with safety unit, regulation and rinse unit. Hydraulic connections in 3/4 flat seal version. To be coupled to the solar pump unit 25-70 (AR) for management of systems with several cylinders or with several sets of collectors. Dimensions: 250 x 375 mm. 3024256 Solar pump unit 25-45 Pumping station for large forced circulation systems, equipped with safety unit. Hydraulic connections in 3/4 flat seal version. Flexible tube and quick-coupling fitting for expansion vessel. 3024258 Thermostatic mixer Bronze mixing valve designed for solar application able to supply constant temperature in a wide range of regulations with reaction times at extremely low thermal transients. Equipped with scald-proof mechanism, protection against calcification and corrosion. Dimensions: 5 x 74 mm. 3024085 GAL EVO motorized mixing valve (plus wires) 302476 Motorized diverter valve Diverter valve for DHW integration management. 230 V power supply. Temperature of the fluid + C/+95 C, maximum functioning differential pressure 4 bar. 3/4 male threaded connections. Dimensions: 94 x 30 x 68 mm. 3087085 Motorized three-way valve diverter motorized valve to use exclusively with Macc tank. Suitable with heating and domestic hot water. Includes wires. 3024076 GAL EVO motorized diverter valve 302477 Fresh water station DHW production module. Minimum flow rate 2,5 l/min. Maximum DHW flow rate 32 l/min. Adjustable temperature from 36 to 65 C. Dimensions 700x400x295 mm 302452 Recirculation kit FWS 30246 Hydraulic kit COMBI 302474 / 23

Solar Accessories Code 8 lt solar expansion vessel 25 lt solar expansion vessel 35 lt solar expansion vessel 50 lt solar expansion vessel 80 lt solar expansion vessel 50 lt solar expansion vessel 200 lt solar expansion vessel Suitable for use in closed heating systems with solar energy as per DIN 4757 and EN 2977. The vessel is equipped with a special membrane for solar systems, certified according to the DIN 4807-3 Standard, which separates the air side from the side containing the solar liquid. The fixing brackets allow stable and safe installation. Maximum pressure equal to 0 bar, System use temperature within -0 C/+99 C. 302438 302439 3024320 302432 3024322 3024323 3024324 Generic solar plate heat exchanger 6kW Generic solar plate heat exchanger 32kW Generic solar plate heat exchanger 48kW Brazed steel plate heat exchanger, suitable for use with domestic hot water and heating. Operational pressure 5 bar, maximum operational temperatures 60/45 C respectively with exchange surfaces (m2)* / number of plates / acceptable volumetric flow rate (l/h) equal to 0.4 / 8 / 720; 0.8 / 34 / 440;.2 / 48 / 2500 Solar heat exchanger for swimming pools 20kW Solar heat exchanger for swimming pools 40kW Solar heat exchanger for swimming pools 70kW *Titanium shell and tube heat exchanger, suitable for heating water in swimming pools. Operational pressure 2 bar. Primary/secondary operational flow rates (m3) respectively of 0.9/0;.7/5; 3/20. 3024036 3024037 3024038 3024039 3024040 302404 Collector side hydraulic adaptation kit Contains hydraulic fitting elements for smooth copper pipe measuring 6-8 and 22 mm and for connection with 3/4 flat seal. Pump unit side hydraulic adaptation kit. Contains hydraulic fitting elements for smooth copper pipe measuring 6-8 and 22 mm and for connection with 3/4 flat seal. Automatic air vent valve 3024070 302407 302458 Stainless steel roof passage pipes. Contains two flexible stainless steel pipes measuring 22 mm with isolation measuring m. Connections for smooth copper pipe measuring 6-8 and 22 mm. Twin pre-isolated pipes Kit containing 0 m of corrugated stainless steel dual piping with 6 mm diameter and preisolated. Collector probe cable is incorporated. A bronze fitting kit is supplied for connection to the collectors and the pumping station. 3024234 3024069 /2 hydraulic safety unit 3/4 hydraulic safety unit hydraulic safety unit siphon 877084 877085 88556 877086 Instruments for filling and maintenance of the solar system Code Pure anti-freeze liquid (5 lt) Non-toxic, odourless and hygroscopic propylene glycol. The corrosion inhibitors contained in the propylene glycol protect the metals normally used in solar installations. Can be mixed with water in all proportions between 25% and 75%. 80025 Anti-freeze liquid manual loading pump Bronze piston pump for connection to the solar system during the filling phase and pressurisation. 800235 24 /

COLLECTIVE SOLAR SYSTEMS / 25

General system diagrams Solar system with 2 tanks, probes and a three way valve Solar system with 2 tanks, valve control and heat exchange Solar system with 2 tanks, of which one is stratified Solar system with 2 tanks and est/ovest collectors Solar system with 3 tanks, valve control and priority logic Solar system with 3 tanks, pump control and priority logic Solar system with tank, swiming pool, collectors, external heat exchanger, three way valve Solar system with 2 tanks, external heat exchanger and pump control 26 /

SOLAR MANAGER PRO Menu simplified and quick to set-up 7 main schemes and + 20 variants 8 sensor inputs and 5 relay outputs 2 PWM or 0/0V signal to drive up to 2 modulating pumps Up to 2 extension modules via VBus connectable (2 sensors and 5 relays in total) Irradiation based function to exploit solar energy Possibility to set up by remote or by SD card Measure and report of solar energy expoitation Compatible with ADEME Fond Chaleur (GRS) protocol Complete accessories range for basic and evolved functions TECHNICAL DATA 205 SOLAR MANAGER PRO Inputs 8 Outputs 4 semiconductor relays, potential-free relay, 2 PWM outputs Power supply 230 Protection type 20 Ambient temperature 0 40 Dimensions 98 x 70 x 43 70 43 98 CODE 3024252 / 27

Solar Manager PRO Accessories Accessories to manage the solar system Code DATALOGGER DL3 PRO With the DL3 Pro you can easily and conveniently log system data of up to 6 controllers get a comprehensive overview of all controllers connected with the large full graphic display. Transfer data with an SD memory card, or use the LAN interface to view and process data on your PC. 3024276 DATALOGGER DL2 PRO This module enables the acquisition and storage of large amounts of data (such as measuring and balance values of the solar system) over a long period of time. System access is possible with just a few clicks via VBus.net For transmission of the data stored in the internal memory of the DL2 to a PC, an SD card can be used. I/O EXTENSION MODULE 6-5 PRO The extension Module provides 5 additional relays and 6 additional sensor inputs. Up to 3 extension modules can be connected to the Solar Manager Pro via VBus. The Extension Modules themselves do not require any adjustments, they are simply connected and assigned to the controller. The inputs and outputs of the registered modules will then be available for all functions of the controller. IRRADIATION SENSOR PRO The solar cell is used for measuring the irradiation intensity. The short-circuit current rises with increasing irradiation intensity. The sensor can also be used for additional functions. The connecting cable can be extended to 00 m. RPD SENSOR PRO Measure the temperature and the relative pressure with a single measuring element and then transmit the measured values directly. They can be optimally used for leakage and overpressure monitoring. Can be used in aggressive media as well as in domestic water and thus are ideal for the application in solar thermal and heating systems. VFD SENSOR PRO SMALL The digital sensor measure the temperature and the flow rate with a single measuring Can be used in aggressive media as well as in domestic water and thus are ideal for measuring the flow rate and the heat quantity in solar thermal and heating systems. VFD Pro Small has an operative flow range -2l / 25-80 C MaxT 00 C (20 C short). VFD SENSOR PRO BIG The digital sensor measure the temperature and the flow rate with a single measuring Can be used in aggressive media as well as in domestic water and thus are ideal for measuring the flow rate and the heat quantity in solar thermal and heating systems. VFD Pro big has an operative flow range 2-40l/ 25-80 C MaxT 00 C (20 C short). SOLAR MANAGER PROBE - COLLECTOR Probe for collectors, related to PRO electronics SOLAR MANAGER PROBE - CYLINDERS Probe for cylinders, related to PRO electronics SOLAR MANAGER PROBE - CUFF TUBE Probe for PRO electronics, to be applied on the pipes OVERVOLTAGE PROTECTION The device should be used in order to protect the susceptible temperature sensors in or at the collector against induced overvoltages. In the case of local thunderstorms, voltage peaks which could destroy the sensor can be induced in the sensor cable. The protector diodes in the Overvoltage protection limit these overvoltages to a value harmless to the sensor. The best way to protect the sensor is to install this connecting box close to the sensor. LAN INTERFACE - SOLAR MANAGER PRO It is designed for the direct connection of the controller to a PC or router. It enables easy access to the controller via the local network of the owner. Thus, controller access, system parametrisation and data read-out can be effected from every workstation of the network. ALARM MODULE PRO It is to be connected to the VBus of the controller and issues an optical signal via the red LED if a failure has occurred. It has a potential-free relay output, which can e.g. be connected to a building management system (BMS) to issue a general warning in the case of a system failure. 3024277 3024279 3024278 3024282 3024280 302428 3024273 3024274 3024275 3024284 3024283 3024292 28 /

PUMP GROUP PRO 20-70 Compact size External PPS casing High efficiency pumps 205 TECHNICAL DATA PUMP GROUP PRO 20-70 Residual loss [m.c.a.] 4,0 3,0 2,0,0 0,0 9,0 8,0 7,0 6,0 5,0 4,0 3,0 2,0,0 0,0 Wilo Yonos PARA ST 5/7 PWM Pump Group Pro 20-70 0 200 400 600 800 000 200 Capacity [m³/h] 37,2 27,4 7,6 07,8 98 88,2 78,4 68,6 58,8 48 39,2 29,4 9,6 9,8 0 Residual loss [kpa] Max. admissible pressure PN 0 Max. operating temperature 20 C Max. short-time temperature 60 C, < 5 minutes Max. propylene glycol content 50% Pressure relief valve 6 bars Pressure gauge 0-6 bars Check valves 2x200 mm wc Valves and fittings Brass Gaskets EPDM Check valves Brass Insulation 0,04 W/(m K) 334 50 CODE 3024256 386 332 7 320 205 60 53 00 For the whole accessory list see page 54 / 29

PUMP GROUP PRO 25-45 Compact size External PPS casing High efficiency pumps 205 TECHNICAL DATA PUMP GROUP PRO 25-45 Residual loss [m.c.a.] 5,0 4,0 3,0 2,0,0 0,0 9,0 8,0 7,0 47,0 37,2 27,4 7,6 07,8 98,0 88,2 78,4 68,6 6,0 Grundfos Solar PML 25-45 58,8 5,0 49,0 Pump Group Pro 25-45 4,0 39,2 3,0 2,0,0 0,0 29,4 9,6 9,8 0,0 0 250 500 750 000 250 500 750 2000 2250 2500 Capacity [m³/h] Residual loss [kpa] Max. admissible pressure PN 0 Max. operating temperature 20 C Max. short-time temperature 60 C, < 5 minutes Max. propylene glycol content 50% Pressure relief valve 6 bars Pressure gauge 0-6 bars Check valves 2x200 mm wc Valves and fittings Brass Gaskets EPDM Check valves Brass Insulation 0,04 W/(m K) 336 58 CODE 3024258 436 46 474 2 205 63 53 00 For the whole accessory list see page 54 30 /

SOLAR STATION PRO Compact size External PPS casing High performing Plate exchanger High efficiency pumps on Solar and secondary circuits DHW compliancy Solar Manager Pro embedded TECHNICAL DATA 205 SOLAR STATION PRO 5 4 3 2 0 9 8 7 6 5 4 3 2 0 Grundfos UPML 25-05 N Solar Station Pro - prim. Grundfos Solar PML 25-45 Solar Station Pro - sec. 0,0 0,2 0,4 0,6 0,8,0,2,4,6,8 2,0 2,2 2,4 47,0 37,2 27,4 7,6 07,8 98,0 88,2 78,4 68,6 58,8 49,0 39,2 29,4 9,6 9,8 0,0 Maximum pressure primary side bar 6 Maximum pressure secondary side bar 0 Maximum temperature primary side C 20 Maximum temperature secondary side C 95 Number of plates exchanger 60 Sensors installed 3 x Pt000 Sensors in the packaging 2 x Pt000 CODE 302426 67 99 7 220 674 602 298 500 27 20 98 795 829 For the whole accessory list see page 54 / 3

FWS PRO MIDI External PPS casing High performing Plate exchanger Instantaneous DHW production reduce bacteria risks ACS and DM74 compliancy Controller embedded TECHNICAL DATA 205 FWS PRO MIDI Tap capacity [l/min] 20 0 00 90 80 70 60 50 40 30 20 0 0 90 C 80 C 70 C 65 C FWS PRO MIDI STORAGE TANK TEMPERATURE Water temperature at the tap: 45 C Water temperature at production: 60 C Cold water temperature: 0 C 280 260 240 220 200 80 60 40 20 00 80 60 40 20 0 Power [kw] Maximum pressure primary side bar 6 Maximum pressure secondary side bar 0 Maximum temperature C 95 Number of plates exchanger 40 CODE 3024263 SINGLE INSTALLATION SCHEME CASCADE INSTALLATION SCHEME 95 50 /2 G 947 /2 G 22 27 27 20 297 52 265 564 32 08 90 G G 795 254 287 670 72 777 20 670 500 A 67 B 96 379 50 64 63 54 40 For the whole accessory list see page 54 32 /

FWS PRO MAXI External PPS casing High performing Plate exchanger Instantaneous DHW production reduce bacteria risks ACS and DM74 compliancy Controller embedded TECHNICAL DATA 205 FWS PRO MAXI Tap capacity [l/min] 20 0 00 90 80 70 60 50 40 30 20 0 0 90 C 80 C 70 C 65 C STORAGE TANK TEMPERATURE Water temperature at the tap: 45 C Water temperature at production: 60 C Cold water temperature: 0 C FWS PRO MAXI 280 260 240 220 200 80 60 40 20 00 80 60 40 20 0 Power [kw] Maximum pressure primary side bar 6 Maximum pressure secondary side bar 0 Maximum temperature C 95 Number of plates exchanger 60 CODE 3024264 SINGLE INSTALLATION SCHEME CASCADE INSTALLATION SCHEME 95 50 /2 G 947 /2 G 22 27 27 20 297 52 265 564 32 08 90 G G 795 254 287 670 72 777 20 670 500 A 67 B 96 379 50 64 63 54 40 For the whole accessory list see page 54 / 33

Solar Accessories Devices and accessories for solar collectors Code CIRCULATION KIT FWS PRO MIDI-MAXI 3024265 CASCADE KIT FWS PRO MIDI 3024268 CASCADE KIT FWS PRO MAXI 3024269 CIRCULATION KIT FWS PRO MIDI CASCADE 3024270 CIRCULATION KIT FWS PRO MAXI CASCADE 302427 3-WAY VALVE PRO - DN 20 Destratification valve to install SOLAR STATION PRO 3024262 3-WAY VALVE PRO - DN 25 Destratification valve to install single FWS PRO MIDI 3024266 3-WAY VALVE PRO - DN 32 Destratification valve to install single FWS PRO MAXI 3024267 3-WAY VALVE PRO - DN 40 Destratification valve to install FWS PRO MIDI in cascade 3024325 RPR SENSOR PRO - PRESSURE SENSOR 3024326 34 /

Devices and accessories to manage solar system SOLAR MANAGER IZY Unit equipped with liquid crystal display that can display and manage up to 0 types of solar plant. Four sensor inputs Pt000, three relay outputs and two PWM outputs to control variable speed circulators. Supplied three probes, two for cylinder and one for the collector. The controller has display the temperatures measured by the probes, diagnostic on-screen function test system, and anti-freeze function. Free Vbus and BACnet compatibility. Compatible with PRO datalogger DL2, DL3 DATALOGGER PRO INTERFACE LAN-SOLAR MANAGER PRO, and PRO MODULE ALARM PROTECTION THE SURGE. Dimensions: 0 x 66 x 47 mm. Code 3024340 SOLAR MANAGER PROBE - COLLECTOR Probe for solar collector, to be added on PRO electronics 3024273 SOLAR MANAGER PROBE - CYLINDERS Probe for cylinders, to be added on PRO electronics 3024274 SOLAR MANAGER PROBE - CUFF FOR PIPE Probe for PRO electronics to be added on pipes 3024275 SOLAR MANAGER CONTROL CARD Card for the complete management of a solar thermal system with forced circulation. Installation parameters completely configurable through system interface SENSYS (not supplied). It includes three temperature sensors NTC 0K B = 3977 (2 probes kettle and a solar collector sensor). It has an output Voltage 230V - max 20 W for managing solar circulator and a voltage output 230 V - max 0 W for managing motorized diverter valve. 302473 DIGITAL THERMOSTAT Device equipped with a probe input and an output for the implementation of a load the high voltage to 250 V as a diverter valve in 2 or 3 wires. The three-digit display It allows the display of the temperature and the setting of parameters operation. Supplied with a cylindrical probe of 6 mm diameter with Ptc000.5 meter cable. Dimensions: 79 x 5 x 42 mm. 800232 Electrical solar kit - natural circulation Flanged resistance kit for natural circulation systems from.5 kw single-phase and power supply of 220 V. Includes flange, magnesium anode, termostasto and cap. 07069 Security group R/2Z Assembly product including safety valve, automatic air vent valve and gauge. 2053830 EXTENSION PUMP PRO 25-45 3024259 PIPES KIT EXTENSION PUMP PRO 25 3024260 / 35

Solar Accessories Hydraulics devices and accessories Code Heating return sensor S4 302475 Thermostatic mixer Mixing valve brass designed for solar application able to provide constant temperature in a wide range of adjustment with reaction times at extremely low thermal transient. Equipped with anti-scald mechanism, protection against calcification and corrosion. Dimensions: 5 x 74 mm. 3024085 Motorized diverter valve Diverter valve for health management integration. 230 V power Fluid temperature + C / + 95 C, maximum differential pressure of 4 bar operation. Threaded male 3/4. Dimensions: 94 x 30 x 68 mm. 3087085 Motorized three-way valve for easy Description: motorized diverter valve vie for exclusive use with Form kettle Macc. Suitable for use with technical water and sanitary water. cabling included 3024076 Motorized diverter valve GAL EVO Diverter valve with spring return for installation on the primary circuit Kairos system Combi 302477 FWS Form instantaneous hot water. Flow Activation 2.5 l / min. Maximum flow health 32 l / min. Set of adjustable temperature between 36 and 65 C. Dimensions 700 x 400 x 295 mm NB: system interface SENSYS be ordered separately. 302452 Recirculation kit FWS 30246 Recirculation kit COMBI 302474 36 /

Hydraulics devices and accessories Code EXPANSION TANKS SOLAR Expansion sola vesselr / healthcare 6 lt for Macc Solar expansion vessel 8 lt Solar expansion vessel 25 lt Solar expansion vessel 35 lt Solar expansion vessel 50 lt Solar expansion vessel 80 lt Solar expansion vessel 50 lt Solar expansion vessel 200 lt 302483 302438 302439 3024320 302432 3024322 3024323 3024324 Generic solar plate heat exchanger 6kW Generic solar plate heat exchanger 32kW Generic solar plate heat exchanger 48kW Heat exchanger steel plate brazed, suitable for use with hot water and heating. 5 bar operating pressure, maximum operating temperature 60/45 C respectively with exchange surfaces (m2) * / number plates / volumetric flow permissible (l / h) of 0.4 / 8/720; 0.8 / 34/440;.2 / 48/2500 Solar heat exchanger for swimming pools 20kW Solar heat exchanger for swimming pools 40kW Solar heat exchanger for swimming pools 70kW * Shell and tube heat exchanger in titanium, suitable for heating swimming pool water. Operating pressure 2 bar. operating ranges (m3) primary / secondary respectively of 0.9 / 0;.7 / 5; 3/20. 3024036 3024037 3024038 3024039 3024040 302404 Adaptation kit hydraulic manifold side It contains hydraulic fitting elements for smooth copper pipe from 6 to 8 and 22 mm and for connection with flat 3/4. 3024070 Adaptation kit hydraulic pump unit side It contains hydraulic fitting elements for smooth copper pipe from 6 to 8 and 22 mm and for connection with flat 3/4. 302407 Steel roof passage pipes It contains two flexible stainless steel tubes from 22 mm insulated m long. Connections for smooth copper pipe from 6 to 8 and 22 mm. 308704 Pre-insulated pipes twins Kit containing 0 m of corrugated stainless steel tube twin 6 mm in diameter and insulated. Collector sensor cable is built. A kit of brass fitting for connection collectors and the pumping station. 3024069 Safety hydraulic group 3/4 877085 Siphon 877086 / 37

Solar Accessories Tools for filling and maintenance of the solar system Code Pure antifreeze liquid (5 lt) Propylene glycol non-toxic, odorless and hygroscopic. Corrosion inhibitors contained in the propylene glycol protect the metals normally used in solar installations. Miscible with water in all proportions between 25% and 75%. 80025 Manual charge pump antifreeze Piston pumps brass for connection to the solar plant during the phase filling and pressurizing. 800235 GROUP OF FILLING THE SOLAR POWERED Filling of the solar powered device that reduces up to 80% faster start-up of the system. Compact and transportable an indispensable tool for those who frequently install solar systems. Prevalence 40 m, tank capacity 20 liters. Dimensions 390 x 430 x 600 mm 302409 Mounting template THERMO HF 50- and 200- on the ground 302494 Mounting template THERMO HF 300-2 ground 302495 Carrying handles kettles THERMO HF 302498 SOLAR CASE Case containing all the tools specific to the pre-installation inspection, the first startup of the solar system and its maintenance ordinary and extraordinary. The case is composed of: A digital ph meter complete with screwdriver and solution (ph 7 @ 25 C) for calibration A refractometer full manual screwdriver, plastic dropper and cloth for cleaning of the prism A digital thermometer with 2 probe Tc-K Two temperature probes Tc-K Clamp A pressure gauge 0.. 4.5 bar A clinobussola A pack of maps for the measurement of ph 3024090 38 /

CYLINDERS / 39

D F K G L E C B 200 / 300 / 450 BCS Floor-standing indirect cylinder with coil Boiler protection with exclusive titanium-based enamel treatment at 850 C Single-coil, folded-down for uniform heating of tank Equipped for recirculation Upper flange with integrated anode and sensor sheath 0 mm front inspection flange Magnesium anode Adjustable support feet 3 kw electrical kit (for 200 and 300 litre models) or,5 kw available on request Ring nut for electrical kit insertion TECHNICAL DATA BCS 200 BCS 300 BCS 450 0 9 A 45 4 J Capacity l 200 295 434 Coil exchange surface m 2,3,6 Max absorbed power kw 3 36 43 Warming time min 28 36 46 DHW Production ΔT=30 C l/h 762 885 057 ΔT=45 C l/h 592 688 822 Pressure loss trought coil mbar 9,0 0,4 3,0 Max working pressure bar 0 0 0 Heat dispersion kwh/24h,74 2, 2,79 Cooling costant wh/l k j 0,8 0,4 0,3 Max working temperature C 90 90 90 Net weight kg 0 35 5 8 7. Domestic hot water outlet M 2. Domestic cold water inlert F 3. Coil return F 4. Coil outlet flow F 7. Side flange ø0 mm 8. Connection for heating element /2 9. Upper magnesium anode 0. Upper probe sheath. Side magnesium anode 2. Side probe sheath 3. Side access door 4. Upper access door 5. Recirculation 5 4 2 3 2 3 OVERALL DIMENSIONS A mm 600 600 74 B mm 32 834 744 C mm 272 794 704 D mm 248 248 270 E mm 434 663 646 F mm 338 338 360 G mm - - 003 J mm 500 500 630 K mm 324 324 354 L mm 730 959 964 CODE 3060440 306044 3060442 For the whole accessory list see page 48 40 /

D F K G L E C B 200 / 300 / 450 BC2S Floor-standing indirect cylinder with double coil Boiler protection with exclusive titanium-based enamel treatment at 850 C Double coil with high surface to couple with fossil or renewable energies Equipped for recirculation Upper flange with integrated anode and sensor sheath 0 mm front inspection flange Magnesium anode Adjustable support feet 3 kw electrical integration kit (for 200 and 300 litre models) or 6 kw available on request Ring nut for electrical kit insertion (for 300 and 450 litre model) TECHNICAL DATA BC2S 200 BC2S 300 BC2S 450 4 Capacity l 200 295 434 Coil Upper Lower Upper Lower Upper Lower Coil exchange surface m² 0,8 0,8,3,6 Max absorbed power kw 27,3 3,0 27,3 36,0 30,8 43,0 0 9 8 A 45 6 5 5 J DHW Production ΔT=30 C l/h 67 762 67 885 757 057 ΔT=45 C l/h 497 667 497 688 589 925 Pressure loss trought coil mbar,0 9,3 0,4,6 3,0 Max working pressure bar 0 0 0 Heat dispersion kwh/24h,74 2, 2,79 Cooling costant wh/l k j 0,8 0,3 0, Max working temperature C 90 90 90 Net weight kg 0 35 5 7. Domestic hot water outlet M 2. Domestic cold water inlert F 3. Lower Coil return F 4. Lower Coil outlet flow F 5. Upper coil return F 6. Upper coil outlet flow F 7. Side flange ø0 mm 8. Connection for heating element /2 (not for 200 l) 9. Upper magnesium anode 0. Upper probe sheath. Side Magnesium Anode 2. Side probe sheath 3. Side access door 4. Upper access door 5. Recirculation 4 2 3 2 3 OVERALL DIMENSIONS A mm 600 600 74 B mm 32 834 744 C mm 272 794 704 D mm 248 248 270 E mm 434 663 646 F mm 338 338 360 G mm 595 998 003 H mm 770 67 089 I mm 270 270 282 J mm 500 500 630 K mm 324 324 354 L mm 730 959 964 CODE 3060448 3060449 3060450 For the whole accessory list see page 48 / 4

MAXIS CDZ 800 / 000 / 500 / 2000 / 2500 / 3000 Floor-standing vertical cylinder with high capacity for the storage of domestic hot water Steel boiler with exclusive titanium-based enamel treatment Magnesium anti-corrosion anode Recirculation Inspection flange Integrated probe-housing sheath Flexible removable insulation Active anode available as accessory 400 mm inspection flange Available heating element up to 5 kw TECHNICAL DATA MAXIS MAXIS MAXIS MAXIS MAXIS MAXIS CDZ 800 CDZ 000 CDZ 500 CDZ 2000 CDZ 2500 CDZ 3000 N O Capacity l 764 884 493 205 2436 2857 Max. working pressure bar 7 7 7 7 7 7 Max. cylinder working pressure C 95 95 95 95 95 95 Cylinder s thermal dispersions kwh/24h 4,59 4,96 6,5 7,75 8,56 9,30 Mempty mass kg 26 237 360 47 550 67 J I H G 7 8 8 5 P 9 2 3 K L M 800-000-500 2000-2500-3000. Cold water inlet G2 F G2 F 2. Hot water outlet G 2 F G 2 F 3. Recirculation G F G ½ F 4. Sanitary circuit return G 2 F G 2 F 5. Draining fitting connection G ¼ F G ¼ F 6. Well G ½ F G ½ F 7. Flange ø 400 ø 400 8. Magnesium anode G ¼ F G ¼ F 9. Upper fitting connection G ¼ F G ¼ F F E D C B A 4 4 4 6 6 6 OVERALL DIMENSIONS A mm 420 420 490 570 540 540 B mm 520 520 590 670 640 640 C mm 965 60 40 25 220 370 D mm 065 260 240 225 320 470 E mm 460 70 780 60 870 2220 F mm 560 90 880 70 970 2320 G mm 800 830 905 975 960 960 H mm 265 050 065 25 50 50 I mm 600 650 550 800 250 J mm 945 295 2335 2245 2465 285 K mm 295 295 365 435 400 400 L mm 835 835 945 025 05 05 M mm 665 95 985 820 2080 2430 N mm 790 790 000 200 250 250 O mm 990 990 200 400 450 450 P mm 00 00 220 420 470 470 CODE 3060464 3060465 3060466 3060467 3060468 3060469 For the whole accessory list see page 48 42 /

MAXIS CD F 800 / 000 Floor-standing vertical single-coil cylinder for the production of domestic hot water. Integrable with forced circulation solar system or high power heating system Steel boiler with exclusive titanium-based enamel treatment Magnesium anti-corrosion anode Recirculation Inspection flange Two integrated probe-housing sheaths Available heating element kit Integrated thermometer Pre-assembled flexible removable insulation Active anode available as accessory Available heating element up to 6 kw TECHNICAL DATA MAXIS CD 800F MAXIS CD 000F Q 2 2 6 O P 9 8 Capacity l 72 860 Max. working pressure bar 7 7 (EN 2897-2006) Max. working cylinder temperature C 95 95 Solar coil surface m 2 2,5 3,0 Solar coil capacity l 4,2 8 Max. working coil temperature C 0 0 Coil power at 900 l/h kw 23,8 / 22 30,9 / 39,5 (according to EN2897/EN5332) Coil load losses at 900 l/h mbar 2 33 Max. coil working pressure bar 0 0 Cylinder s thermal dispersions kwh/24h 5,7 6,05 Empty mass kg 20 272 K J L I H 5 0 6 3 E C D B A F G. Cold water inlet G2 F 2. Hot water outlet G 2 F 3. Recirculation G F 4. Sanitary circuit return G ½ F 5. Draining fitting connection G ¼ F 6. Well G ½ F 7. Flange ø 0 8. Magnesium anode G ¼ F 9. Thermometer 0. Primary ciurcuit flow G ½ F. Primary ciurcuit return G ½ F 2. Upper fitting connection G ½ F 4 7 OVERALL DIMENSIONS A mm 295 295 B mm 460 440 C mm 660 730 D mm 760 830 E mm 90 030 F mm 560 80 G mm 665 95 H mm 475 495 I mm 000 35 J mm 540 790 K mm 945 295 L mm 360 685 M mm - - N mm - - O mm 790 790 P mm 990 990 Q mm 005 005 CODE 3060485 3060486 For the whole accessory list see page 48 / 43

MAXIS CD 800 / 000 / 000 / 500 / 2000 / 2500 Floor-standing vertical single-coil cylinder for the production of domestic hot water. Integrable with forced circulation solar system or high power heating system Steel boiler with exclusive titanium-based enamel treatment Magnesium anti-corrosion anode Recirculation Inspection flange Integrated probe-housing sheath Available heating element kit Integrated thermometer Flexible removable insulation Active anode available as accessory 400 mm inspection flange Available heating element up to 5 kw on the lateral flange, and up to 6 kw on the cap connection TECHNICAL DATA MAXIS CD 800 MAXIS CD 000 MAXIS CD 500 MAXIS CD 2000 MAXIS CD 2500 Q 2 2 O P Capacity l 72 860 458 896 2399 Max. working pressure (EN 2897-2006) bar 7 7 7 7 7 Max. working cylinder temperature C 95 95 95 95 95 Solar coil surface m 2 2,5 3 4,5 5,4 6 Solar coil capacity l 4,2 8 26,6 32,6 36,6 Max. working coil temperature C 0 0 0 0 0 Coil power at 900 l/h (according to EN2897/EN5332) kw 22/23,8 30,9/39,5 30,9 / 39,5 39,9 / 57,5 46, / 65,3 Coil load losses at 900 l/h mbar 2 33 33 44 48 Max. coil working pressure bar 0 0 0 0 0 Cylinder s thermal dispersions kwh/24h 5,55 5,9 7,45 8,25 9,04 Empty mass kg 246 272 420 487 630 K J I H 7 5 6 0 6 A B E C D G F. Cold water inlet G2 F 2. Hot water outlet G 2 F 3. Recirculation G ½ F 4. Heating element G ½ F 5. Draining fitting connection G ¼ F 6. Well G ½ F 7. Flange ø 400 8. Magnesium anode G ¼ F 9. Thermometer 0. Primary ciurcuit flow G ½ F. Primary ciurcuit return G ½ F 2. Upper fitting connection G ¼ F 9 4 8 8 8 L M N OVERALL DIMENSIONS A mm 295 295 365 435 400 B mm 45 425 495 560 555 C mm 795 865 980 060 065 D mm 895 965 080 60 65 E mm 95 35 435 460 535 F mm 560 80 880 70 970 G mm 665 95 985 820 2080 H mm 800 830 905 975 960 I mm 260 395 505 525 660 J mm 540 790 875 695 955 K mm 945 295 2335 2245 2465 L mm 900 930 005 075 060 M mm a a 590 N mm 500 765 750 650 920 O mm 790 790 000 200 250 P mm 990 990 200 400 450 Q mm 00 00 220 420 470 CODE 3060475 3060476 3060477 3060478 3060479 For the whole accessory list see page 48 44 /

MAXIS CD2 F 800 / 000 / 500 / 2000 / 2500 Floor-standing vertical double-coil cylinder for the production of domestic hot water. Integrable with forced circulation solar system or high power heating system Steel boiler with exclusive titanium-based enamel treatment Magnesium anti-corrosion anode Recirculation Inspection flange Integrated probe-housing sheath Available heating element kit Integrated thermometer Flexible removable insulation Large solar surface exchanger and integration for the maximum efficiency Coil and back sanitary connections for easy installation Available 6 kw heating element TECHNICAL DATA MAXIS CD2 800F MAXIS CD2 000F MAXIS CD2 500F MAXIS CD2 2000F MAXIS CD2 2500F Q P O N M L K 4 9 6 7 T 4 5 800-000 - 500 2000-2500. Cold water inlet G2 F G2 F 2. Hot water outlet G 2 F G 2 F 3. Recirculation G F G ½ F 4. Heating element G ½ F G ½ F 5. Draining fitting connection G ¼ F G ¼ F 6. Well G ½ F G ½ F 7. Flange ø 0 ø 0 8. Magnesium anode G ¼ F G ¼ F 9. Thermometer 0. Lower coil flow G ½ F G ½ F. Lower coil return G ½ F G ½ F 2. Upper coil flow G ½ F G ½ F 3. Upper coil return G ½ F G ½ F 4. Upper fitting connection G ¼ F G ¼ F 2 6 2 6 3 3 0 6 A B R C D S E F G H I J 8 8 Capacity l 706 846 44 883 2378 Max. working pressure (EN 2897-2006) bar 7 7 7 7 7 Max. working cylinder temperature C 95 95 95 95 95 Solar coil surface m 2 2,4 2,5 4,2 4,5 6,0 Solar coil capacity l 4,2 4,5 24,6 27, 36,6 Solar coil power at 900 l/h* kw 24,6 / 45,3 30, / 62, 37,2 / 70,9 39,9 / 57,5 5,2 / 72,4 Coil load losses at 900 l/h mbar 23 23 67 45 50 Max. working coil pressure bar 0 0 0 0 0 Solar coil surface m 2 2,4 2,5 2,5 3 3,5 Upper coil capacity l 4,2 4,5 4,5 8, 2,2 Upper coil power at 900 l/h kw 8 / 23,5 34,7 / 60,3 34,7 / 60,3 35,2 / 65,2 36 / 70, Upper coil load losses at 900 l/h mbar 5 22 22 23 28 Max. working coil pressure bar 0 0 0 0 0 Max. working coil temperature C 0 0 0 0 0 Cylinder s thermal dispersions kwh/24h 4,44 4,9 6,6 7,03 8,7 Empty mass kg 236 257 40 477 635 * (according to EN 2897/EN5332) OVERALL DIMENSIONS A mm 295 295 365 435 400 B mm 460 460 520 560 555 C mm 760 760 995 925 030 D mm 90 90 230 0 270 E mm 050 5 380 265 475 F mm 290 360 555 45 645 G mm 350 465 650 520 755 H mm 500 565 785 645 895 I mm 560 80 880 70 970 J mm 665 95 985 820 2080 K mm 475 475 570 690 645 L mm 65 325 M mm 980 05 305 25 405 N mm 250 25 45 450 O mm 560 685 865 700 955 P mm 540 790 875 700 955 Q mm 945 295 2335 2245 2465 R mm 790 790 000 200 250 S mm 990 990 200 400 450 T mm 005 005 25 45 465 CODE 3060487 3060488 3060489 3060490 306049 For the whole accessory list see page 48 / 45

G H I D EF L A B C L BUFFER CYLINDER FOR PRIMARY CIRCUIT WATER WITH COIL 400 / 600 / 800 / 000 MAXIS CK Buffer cylinder for primary circuit water with coil Black steel cylinder Parallel connections for the solar coil, arrangement for easy connection to the digital solar pump group-internal pipes and arrangement for easy installation on dhw module Possibility of integration with electrical resistance and connession for air release system Designed for integration with Fresh Water Station and Solar Pump Group TECHNICAL DATA MAXIS CK 400 MAXIS CK 800 MAXIS CK 600 MAXIS CK 000 Q R Capacity l 374 559 724 830 Max. working pressure bar 3 3 3 3 Max. working cylinder temperature C 95 95 95 95 Solar coil surface m 2,5 2, 2,8 3,4 Solar coil capacity l 9,3 3 7,5 2 Max. working coil temperature C 0 0 0 0 Coil power at 900 l/h kw 24/ 6,2 28,4/ 50,7 28,6/ 24,8 32,4/ 57,7 (according to EN2897/EN5332) Coil load losses at 900 l/h mbar 2 25 32 32 Max. working coil pressure bar 0 0 0 0 Cylinder s thermal dispersions kwh/24h,75 2,20 2,5 2,7 Empty mass kg 92 3 55 76 2 3 4 5 6 7 8 9 0. Air valve G F 2. Boiler flow G F 3. Well G ½ F 4. Heating flow G F 5. Heating element G ½ F 6. Well G ½ F 7. Return boiler G F 8. Well G ½ F 9. Heating return G F 0. M6 bolt for connection of digital solar pump group. Solar flow G ¾ F 2. Solar return G ¾ F 3. DHW production module return G ¾ F 4. M8 bolt for connection of DHW production group 5. DHW production module flow G ¾ F 2 3 o 5 4 M N P OVERALL DIMENSIONS A mm 235 230 260 260 B mm 45 405 500 500 C mm 630 760 775 900 D mm 700 85 855 980 E mm 785 900 950 075 F mm 880 000 060 85 G mm 060 400 35 550 H mm 50 550 405 640 I mm 240 645 495 730 L mm 550 865 725 975 M mm 380 380 380 380 N mm 80 80 80 80 O mm 80 80 80 80 P mm 630 945 805 2055 Q mm 800 850 990 990 R mm 600 650 790 790 CODE 3060460 306046 3060462 3060463 For the whole accessory list see page 48 46 /

MAXIS CKZ BUFFER CYLINDER FOR PRIMARY CIRCUIT WATER, WITHOUT COIL 500 / 2000 / 2500 / 3000 Buffer cylinder for primary circuit water, without coil Black steel cylinder 82 connections to manage high power and high capacity sources Ideal to match with plate heat exchangers to storage primary circuit water from solar and other sources Direct connection with the boiler thanks to 6 bar working pressure 8 probe holders (4 immersed and 4 contact probe holders) TECHNICAL DATA MAXIS CKZ 500 MAXIS CKZ 2000 MAXIS CKZ 2500 MAXIS CKZ 3000 G F 2 3 Capacity l 473 97 2363 2667 Max. working pressure bar 6 6 6 6 Max. working cylinder temperature C 95 95 95 95 Cylinder s thermal dispersions kwh/24h 6,52 7,77 8,2 8,75 Empty mass kg 224 256 297 324 G F 2 3 3 3 A B OVERALL DIMENSIONS A mm 372 335 390 390 B E mm 87 885 860 950 CD mm 342 44 365 50 D mm 750 990 820 2070 CE mm 250 2408 2265 255 F mm 000 00 250 250 G mm 200 300 450 450 3 3 E 3 D C 3 B A. Primary ciurcuit connection G 2 F 2. Air release valve G 2 F 3. Probe well G ½ CODE 3060456 3060457 3060458 3060459 For the whole accessory list see page 48 / 47

Cylinder Accessories Electrical kits Code BCS BC2S CDZ CDF CD CD2F CK Electrical kit 3 kw Includes: heating element, flange 0 mm, wiring and rod thermostat 9358 (only for 200 and 300 liters) Electrical kit three-phase 6 kw Includes: heating element, flange 0 mm, wiring and bubl thermostat mono and threephase 9359 Electrical kit,5 kw Includes: /2 screw-on heating element and thermostat. EPR: IP 2 for installation on single-phase side flange 935393 (no BC2S 200) (only 800 000) Electrical kit 2,5 kw Includes: /2 screw-on heating element and thermostat. EPR: IP 2 for installation on single-phase side flange 935394 (no BC2S 200) Electrical kit 6 kw Includes: /2 screw-on heating element and thermostat. EPR: IP 2 for installation on three-phase side flange 3078066 Electrical kit 9 kw Includes heating element on 400 mm flange and thermostat. 3078058 (only CD) Electrical kit 5 kw Includes heating element on 400 mm flange and thermostat. 3078059 (only CD) Small active anode Kit 307806 (800 000) Medium active anode Kit 3078062 (500) (800) Large active anode Kit 3078063 (2000) (000 500) Extra Large active anode Kit 3078064 (2500 3000) (2000 2500) Safety group Hydraulic safety group 88556 Hydraulic safety group R/2Z 2053830 48 /

HOW TO READ THE SYMBOLS The icons have been designed to facilitate the reading of the features of each product. Ariston makes it possible, from the very beginning, to quickly and easily identify performance levels, understand the different ranges and evaluate purchasing criteria. In short, users can familiarise themselves with each machine without becoming confused or wasting time, in line with the Ariston philosophy of always offering the customer - and the professional technician - a service which is clear and easy to use. ENERGY EFFICIENT Better exploitation of energy and renewable sources, enhanced performance MADE IN ITALY Made in Italy SYSTEM MANAGEMENT Manage all Ariston products connected in system thanks to BusBridgeNet technology SOLAR KEYMARK Compliant with European quality certification for solar systems HAIL-PROOF Hail-resistant thick glass EASY INSPECTION Large inspection flange for an easier access to the internal components of the products SOLAR INTEGRATION It can be connected in system with Ariston solar-sourced products PERFORMANCE PLUS Enhanced performance thanks to the high quality material selection to increase heat absorption and limit heat dispersion MADE IN EUROPE Made in Europe / 49