KALIDO 73. Convector Gas Fire MODEL NUMBERS: ACF526NG & ACF526P INSTALLATION, USER AND SERVICING INSTRUCTIONS

Similar documents
INSET LIVE FUEL EFFECT GAS FIRE

OWNER S GUIDE MODEL BR417 VA

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

Dovre 250 Cast Iron Gas Stove

Model BR660VA Heat Engine

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

morsø PANTHER GAS STOVE

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

Sonnet Plus Anthem Genesis Soraya

Model 341 Black Beauty Slimline

Sonnet Plus Anthem Genesis Soraya

Limours. Balanced Flue Room Heater MODEL NUMBER : KBFP00RN INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Squirrel - Gas Stoves

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

VESTA LOG FIRE VLF45NG, VLF45NG, VLF45P, VLF45P Manual & Remote Operated Models

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

Dovre 280. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

Riva 53/67. Inset Convector Fire - Balanced Flue. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing

THIS PRODUCT IS APPROVED TO THE EUROPEAN GAS APPLIANCE DIRECTIVE

Exmoor. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Riva2 530/670. Inset Convector Fire - Conventional Flue. with Thermostatic Remote Control. Instructions for Use, Installation & Servicing

Huntingdon 20/30/40. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

MODEL 466 Radiant / Convector Gas Fire Black Beauty

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

Dartmoor. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

RADIANT / CONVECTOR GAS FIRE MODEL 426 (GC ) INSTALLATION & SERVICING INSTRUCTIONS INSTALLER: Please leave these instructions with the owner

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

Vogue Range. Conventional Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Kalahari RC & Camber RC

Riva Nemos. Balanced Flue Convector Fire. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Eire) IMPORTANT

Small Marlborough, Stockton & Steel Manhattan

Plus Model BR645 VA (G.C )

INSTALLER GUIDE. Firefox 8. Model 944. CAST-IRON GAS STOVE Fitted with a Ceramic Coal fuel effect. (GC No )

Dovre 280. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Decorative Fuel Effect Appliances

ULTRAFLUE ACCLAIM GAS COAL CONVECTOR

Firefox 5. Model 910 CAST-IRON GAS STOVE. Fitted with a Ceramic Coal fuel effect. INSTALLER: Please leave this guide with the owner

Conventional Flue Coal Effect Stove. With upgradeable control valve. Instructions for Use, Installation and Servicing

Marlborough & Stockton

Ceramica Log Effect Stove Range

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

Model 347 BLACK BEAUTY

Exmoor. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Exe. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Model Apex Falcon, Titan & Zenit

Clarendon & Ashdon. Conventional Flue Log Effect Stove Range. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing

Classic DECORATIVE FUEL EFFECT GAS FIRE. Installation, Maintenance & User Instructions

Steel Manhattan Coal Effect Stove Range

BALLADE BALANCED FLUE CONVECTOR FIRE

Model 939 Heat Engine

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

F67 RIVA, F67 RIVA PEDESTAL, F67 RIVA BENCH Conventional & Balanced Flue Convector Fire

INSTALLER S GUIDE. MODEL 639 Open Decorative Gas Fire

Dartmoor. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Huntingdon 20/30/40. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Riva2 F670. including optional Apex Stand and Bench. Conventional Flue with Thermostatic Remote Control

Dovre 280. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Riva2 530/670. Inset Convector Fire - Balanced Flue. With Thermostatic Remote Control. Instructions for Use, Installation & Servicing

VFC Radiant & Convector

Baxi Brazilia F5, F5S & F8S

Riva2 530/670. Inset Convector Fire - Conventional Flue. with Thermostatic Remote Control. Instructions for Use, Installation & Servicing

Riva2 530/670. Inset Convector Fire - Balanced Flue. With Thermostatic Remote Control. Instructions for Use, Installation & Servicing

Installation & Service Instructions

Clarendon & Ashdon. Balanced Flue Log Effect Stove Range. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing

Steel Manhattan. Balanced Flue Log Effect Stove Range With Upgradeable Control Valve. Instructions for Use, Installation & Servicing

INSTALLER AND OWNER GUIDE. For further advice please contact the retailer or company from where you purchased your stove

Yeoman CL3 & CL5. Conventional Flue Log Effect Fire. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Eire)

Stockton 5. Conventional Flue Coal Effect Stove. With upgradeable control valve. Instructions for Use, Installation and Servicing

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

Clarendon and Ashdon Log Effect Stove Range

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

Yeoman CL Range. Balanced Flue Log Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Marlborough & Stockton Coal Effect Stove Range

Huntingdon 30. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation and Servicing

Conventional Flue. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Republic of Ireland) IMPORTANT

Yeoman CL3 & CL5. Balanced Flue Log Effect Fire. Instructions for Use, Installation and Servicing. For use in GB, IE (Great Britain and Eire)

Clarendon and Ashdon Coal Effect Stove Range Conventional Flue

Stockton 5. Conventional Flue Coal Effect Stove. With Upgradeable Control Valve. Instructions for Use, Installation & Servicing

Model 339 Heartbeat Oxysafe 2

Riva Inset Convector Fire - Conventional Flue. with Thermostatic Remote Control. Instructions for Use, Installation & Servicing

INSTALLER AND OWNER GUIDE. Model 944 Manual & Remote Control (RC) GAS STOVE Supplied with a Ceramic Coal or Log fuel effect.

INSTALLER AND OWNER GUIDE. Model 944 Manual & 944RC Remote Control. CAST-IRON GAS STOVE Fitted with a Ceramic Coal or Log fuel effect.

FIRECHARM LF ELECTRONIC

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME EVOLUTION PLUS GAS EFFECT FIRES (NATURAL GAS & LPG) FOR DECORATIVE PURPOSES ONLY

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

Logic Hotbox & Convector Fire

INSTALLER GUIDE. Model 754. INSET LIVE FUEL EFFECT GAS FIRE Fitted with. Artura fascia. (GC No )

Sonnet Plus Anthem Genesis Soraya

MODEL 466 Radiant / Convector Gas Fire Black Beauty

Orchestra COAL EFFECT BALANCED FLUE GAS FIRE

Instructions for Use, Installation and Servicing

Installation & Operating Instructions For LPG Q5 Stoves IGNITE 5 GAS STOVE (CD1) HEREFORD 5 GAS STOVE (CD2) DESIRE 5 GAS STOVE (SD1) Manual Control

Transcription:

KALIDO 73 Convector Gas Fire MODEL NUMBERS: ACF526NG & ACF526P INSTALLATION, USER AND SERVICING INSTRUCTIONS THESE INSTRUCTIONS MUST REMAIN WITH THE USER 0120 THIS APPLIANCE MEETS THE REQUIREMENTS OF THE EUROPEAN GAS DIRECTIVE BEFORE INSTALLATION, CHECK THAT THE LOCAL DISTRIBUTION CONDITIONS, NATURE OF GAS & PRESSURE AND ADJUSTMENT OF THE APPLIANCE ARE COMPATIBLE. Ambifuego Avda Cañada del Cura, 29, Pol. Ind. de Levante 03187 Los Montesinos - Alicante. Tel. 96 6721018 Fax. 96 6721023 Correo electrónico: info@ambifuego.net web: www.ambifuego.net October 2005 ACF526 Issue Technigas

Installation & Service Record Please ensure that installer completes the installation record below RECORD OF 1 st SERVICE INSTALLATION RECORD Appliance Supplied by:... Installation Date: Serial No.:.... Installed By:.....Reg. No.:.. Signed by Installer:.. RECORD OF 3 rd SERVICE. RECORD OF 5 th SERVICE RECORD OF 7 th SERVICE RECORD OF 9 th SERVICE.. RECORD OF 2 nd SERVICE.. RECORD OF 4 th SERVICE.. RECORD OF 6 th SERVICE RECORD OF 8 th SERVICE.. RECORD OF 10 th SERVICE.. 2

Important Notes Please read before undertaking the installation 1. This is not a Do it yourself product and it must be installed by a competent person. 2. The fire has a ceramic Fire-bed arrangement; this contains Refractory Ceramic Fibres, which are man-made vitreous silicate fibres. Excessive exposure to these materials can cause irritation to eyes, skin and respiratory organs. Hence we recommend that when handling these materials the release of dust should be kept to a minimum. During installation and servicing we recommend that a HEPA filtered vacuum be used to remove any dust and soot in and around the fire. If any of the ceramic fire-bed components need to be replaced we recommend that the removed parts be sealed in a heavy-duty polythene bag, and be labelled as RCF waste. RCF not Hazardous waste and can be disposed of at a licensed tipping site for the disposal of industrial waste. The appliance incorporates a permanent pilot. This is located on the front of the burner, and must not be adjusted by the installer. This system must not be put out of operation, and if any parts require changing, only original manufacturer parts shall be used. This appliance is designed to be used either Natural or LPG gas however, each individual appliance is only capable of running off the type of gas specified at the time of purchase. It is important to note that once a type of gas has been specified the fire cannot run off any other type. The type of gas that your fire is capable of burning is stated on the data information panel. This appliance has been designed, tested and approved to meet standards in place for product use, performance and safety. Installation of your appliance must comply with current building regulations. It is therefore recommend that a registered gas installer be employed for this task. The engineer will provide you with information about the safety limits of the installation and should fix a notice plate in a place where it can be readily seen. This appliance is designed as a decorative heating device and consequently all body parts become very hot in use. Except for the control knob and control access door, which are designed to stay cool, all other parts are working surfaces and should not be touched. The front of this appliance does not give full protection for young children, the elderly or infirm, extra protection should be considered for these conditions conforming to BS 6539 or BS 6778. The appliance is not fitted with a functional integral guard. In normal use, consideration should be given to the use of an additional guard, conforming to the standard above, such that access to the open flame is minimised 3. The chimney must be swept before the appliance is fitted. 4. The Installation Instructions must be adhered to without exception. Before fitting this appliance, ensure that the following components are enclosed a) Gas Fired Convector complete with burner and controls. b) Installation, Servicing & Users Instructions c) 1 Packet of ceramic fibre flakes c) Decorative frame and louvered bottom cover 3

e) Five Piece Log Set. APPLIANCE DATA ACF526NG ACF7526P GAS TYPE NATURAL GAS PROPANE SUPPLY PRESSURE 20mb 37mb HEAT INPUT 6.8kW Net 6.6kW Net GAS RATE 0.72m/h 0.2m/h 512g/hr INJECTOR SIZE Ø 2.1 mm Ø 1.35mm GAS CONNECTION 8mm COMPRESSION ELECTRICAL 230V / 50Hz / 3A Burner Pressure 17,5mbr 27mbr NOX Concentration Class 5 GENERAL INSTALLATION REQUIREMENTS Fitting the Appliance 1 This installation must be carried out in accordance with all local laws and regulations. 2 The 526 Convector can be fitted into fireplace openings which are large enough or can be altered to accept this appliance. The dimensions are shown in Figure 1. If the fireplace has to be altered a lintel may be required to support the masonry over the opening. The fireplace opening should be formed FIGURE 1 from or lined with non-combustible material. 3 The installation must meet the requirements of the current CE regulations. 4 The Hearth The hearth supporting the appliance within the fireplace must be made of a non combustible material at least 12mm in thickness. Because of the heat radiated from this appliance the hearth should extend 250mm in front of the appliance. Alternatively the appliance may be installed 250mm above finished floor level without requiring the extended hearth. 5 The Chimney Flue The following types of chimney or flues are acceptable: a) A conventional open flue connected with a short length of 100mm diameter flue pipe and a register plate or lined with a flexible flue liner of at least 100mm diameter T250 rating. b) A 100mm diameter (or larger) gas flue The flue must have a minimum effective height of 3 metres. 90º bends are not allowed. 4

No restrictor plate or flue damper is permitted. Where a variable damper is fitted, this must be removed. c) A dedicated power flue kit is available for the appliance. The appropriate fitting instructions are supplied with the kit. 7 Ventilation. Purpose made ventilation must be installed in accordance with local regulations. 8 The appliance is designed for use with both natural gas and propane. The two gases require different burners that are not interchangeable between the different gas types.. 9 The appliance must not be installed in a room containing a bath or shower or in a private garage. 10 Shelf If a shelf made of combustible material is to be fixed to the wall above the appliance a space of at least 150mm must be left between the top of the fascia and the underside of the shelf. Fitting the Firebox 1 Check that the fireplace is of the correct size or has been modified to accept the selected firebox. (See Figure 1) 2 It is recommended that, before proceeding further, a simple smoke test be performed to check the condition of the chimney. Light a smoke match or a twist of rolled paper, hold it under the open flue and observe the behaviour of the smoke. If it is being drawn into the chimney proceed with the installation. If not, pre-heat the chimney over the period of a few minutes and recheck. If there is any doubt about the soundness of the chimney a smoke pellet should be used after preheating the flue and if smoke still fails to clear, further investigation of the chimney is required and the appliance MUST NOT be fitted until any fault has been rectified. 3 Clear the recess of any loose material and ensure that the base on which the appliance will stand is level. 4 Make good the plasterwork or wall decoration up to the edges of the fire opening. 5 Disassemble the appliance in order to separate the flue connector from the convector box so that it can be connected to the chimney. 5

a b c d e Remove the glass window by undoing the two nuts + two screws and lifting clear. Store it in a safe place. Remove the screw at the bottom of the fascia and pull the burner forward. Remove the four screws holding the control fascia in position. Remove the screw holding the circulation fan switch plate to the gas control valve. Loosen the thermocouple nut and remove the connection wires from the flue temperature switch. Lift the burner assembly clear of the appliance. Undo the four screws holding the firebox in the convector box and lift the firebox out of the convector box. See figure 2. As the firebox is lifted away disconnect the circulation fan lead from the wiring box by separating the Molex connectors. Unscrew the ten self tapping screws securing the flue break assembly to the convector box and remove. From inside the convector box loosen the four screws holding flue connector, slide it sideways and remove from the outside of the convector box. FIG. 3 6 Install the register plate and the connecting length of flue pipe or line the chimney with 100mm flexible flue liner. Connect and seal the lower end of the flue pipe or liner to the flue connector. Temporarily lodge the flue connector in position until the convector box is placed in position. Alternatively a gas flue can be used in which case the appropriate appliance connector will have to be selected. 7 The gas supply should be routed from the meter or cylinder to a point at the rear of the fireplace. This point should be on the centre line of the appliance and 35mm above the base on which the convector box will sit. From this point route the supply in 8mm diameter tubing forward to the front of the fire opening. Exposed pipe within the fire opening should be wrapped, painted with bituminous paint or factory sheathed. 8 Knock out the gas entry hole in the rear of the convector box with a sharp hammer blow. Place a diaphragm grommet (supplied) in the hole and cut a slit for the gas supply pipe. Slide the convector box into position. Reach up through the flue aperture and draw the flue connector down into position. Pull the four screws previously loosened through the keyhole slots, slide sideways and tighten the four screws. Re-assemble the flue break assembly into the convector box with the ten self tapping screws previously removed. Make sure the convector box is pushed fully home and then fix the flanges to the wall with wall plugs and screws. Make sure the flue temperature switch sensor is still in position in its bracket. 9 Place the heat exchanger in position in front of the flue assembly within the convector box making sure that the flue spigot on the back of the firebox is inserted into the rectangular hole in the flue break. Re-connect the power supply to the fan using the 6

molex connector. Fix into place with the four screws previously removed. 10 Temporarily place the burner and mark the gas pipe for cutting. Trim the gas supply pipe to the mark. The end of the supply tube should finish 10 mm above the base. Prior to connecting the burner to the gas supply it is advisable to blow out the pipe to clear any dirt that may be present and which could cause a blockage in the control valve or pilot. 11 Replace the connection from the flue temperature switch and tighten the thermocouple nut (Caution; do not over tighten). Replace the burner/control assembly in position and secure. Fix the switch box to the gas control valve with the M4 screw previously removed. Replace the fascia panel and secure with four black headed self tapping screws. Using the nut and olive provided, connect the 8mm supply pipe to the pressure test point fitting. 12 Gas Soundness Check Once the gas supply is connected, all joints must be checked for gas soundness. Note: It is permissible to light the fire for short periods when the burner has not been filled with the loose infill. ELECTRICAL CONNECTION TO MAINS SUPPLY 1 It is recommended that the electrical connection to the mains supply is made via a fused spur or an un-switched three-pin socket and plug. The supply MUST BE FITTED WITH A 3A FUSE. 2 The appliance is supplied with 2.5 metres of three-core mains cable pre- wired to the circulation fan and its speed control switch. This should be routed to the power point as inconspicuously as possible - i.e. chased into the plaster. Filling the Burner. Fill the burner tray level to the top using the ceramic fibre flakes provided making sure that the burner ports between the flame guides down the centre are left completely clear. Any flakes that are too large may be broken to fit. Placing of the Refractory Logs. Keep logs clear of the pilot flame to ensure good cross lighting. Lay the logs a shown in the Figures. 7

Closing the Glass Door. 1 Place the glass door in position over the studs on the heat exchanger making sure the joint in the rope seal lies along the lower edge. Secure in position with the 2 nuts and 2 screws. Tighten evenly. Installing The Decorative Frame. 1 Hook the decorative frame over the supporting lugs within the convector box. COMMISSIONING WARNING. This appliance is fitted with a spillage monitoring system consisting of a flue temperature switch. Should the chimney become blocked, the sensor will become hot, and the appliance will go out. The installer must not attempt to adjust this system, nor shall he put it out of operation. Should any part of this system need to be replaced, only original manufacturers parts shall be used. 1 Before attempting to light the appliance the gas supply must be turned on by removing the cap from the isolator fitting and unscrewing the plug all the way out. Replace the cap making sure that the tab engages with the slot in the top of the plug. Tighten the cap securely. Light the appliance in accordance with the instructions in the lighting section. Briefing the User 1 Demonstrate the full operation of the appliance to the customer. 2 Inform the customer that all cleaning procedures should be carried out only when the appliance is cold. 3 Leave these instructions with the customer. 4 Advice the importance of having the appliance serviced and the chimney checked for clearance of combustion products on an annual basis. SERVICE AND MAINTENANCE BEFORE ANY SERVICING IS CARRIED OUT ISOLATE THE APPLIANCE FROM THE GAS SUPPLY. AFTER REFITTING THE APPLIANCE, CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS AND TEST FOR SPILLAGE. This product may use fuel effect pieces containing Refractory Ceramic Fibre (RCF). This material contains man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. 8

To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that a HEPA filtered vacuum cleaner is used to remove any dust accumulated in and around the appliance before and after working on the appliance. We recommend that any replaced items are not broken up, but are sealed within heavy duty polythene bags and clearly labelled as RCF waste. RCF waste is classed as a stable, non-reactive hazardous waste and may be disposed of at landfill sites licensed to accept such waste. Protective clothing is not required when handling these articles but we recommend that the normal hygiene rules are followed of not smoking, eating or drinking in the work area and that hands are washed before eating or drinking. The appliance should be serviced at least once a year by a gas fitter registered in The UK & Ireland. This is the basic procedure, and law of the EU. 1 Unclip and lift away the decorative frame. 2 Unscrew the two nuts +two screws and remove the glass door. 3 The refractory logs should be taken off the fire and shaken to remove any debris but should only be cleaned if absolutely necessary. This should be done by gently brushing with a soft brush in a direction away from the person and any persons nearby. This operation should be performed outside facing downwind. A vacuum cleaner must not be used for this purpose. 4 The gas supply should have been turned off the isolation point. Disconnect the gas supply pipe from the pressure test point fitting. Remove the burner / control unit and lift it out of the firebox as described in the installation section. 5 Empty the ceramic flakes from the burner on to a clean surface and thoroughly clean the burner ports. 6 Operate the spark generator and observe that the spark is satisfactory. 7 Lay the control mount assembly on a flat surface and remove, clean and replace the main injector. 8 Any soot or debris should be removed from the flue ways and it should be inspected for soundness. To inspect the flue the main heat exchanger will have be removed as described in the installation section. 9 Refit the burner / control unit in position. Re-connect the gas supply. Refill the burner with the ceramic flakes making sure none is placed over the burner ports. Replace the refractory logs on the burner. 10 Replace the glass door and secure. Tighten the fastenings evenly. AFTER REFITTING THE APPLIANCE CHECK FOR GAS SOUNDNESS AT ALL GAS JOINTS AND TEST FOR SPILLAGE. 12 Replace the decorative frame. 13 The service record sheet enclosed with these instructions should be complete to maintain the validity of the warranty. 9

USERS GUIDE Useful tips & recommendations Once your appliance has been fitted, the following recommendations are made to ensure you enjoy the best results from your purchase; 1 The installation of this appliance must have been carried out by a qualified installer and in accordance with all local laws and regulations. 2 The chimney must be swept before the appliance is installed and checked annually to ensure continued clearance of combustion products and that there is no excessive buildup of soot. 3 The glass door and the upper part of the decorative frame are considered to be a working surfaces and as such will become hot when in use. Care should be exercised when using the controls of the appliance when it is hot. We also recommend that a fireguard be fitted for the protection of young children, the elderly or infirm. 4 When new any ceramic components may produce a slight odour, but this will completely vanish after a few hours of use. 5 The appliance MUST NOT be used with the door open or with the glass panel removed. If there is any suspicion of damage to the glass the appliance must not be used. 6 Check periodically that any purpose-made ventilation is free from obstruction. 7 To obtain the best results from your fire we recommend that it be serviced annually. 8 These instructions are provided to assist you to operate the fire correctly and should be kept in a safe place. 9 If you have any reason to suspect a gas leak, turn off the appliance at the isolating point and contact your installer. 10 This appliance is fitted with a flue blockage device that will shut off the appliance in the event of abnormal flue conditions. If this device repeatedly shuts off the appliance your installer should be informed and the cause rectified. This device is NOT a substitute for an independently mounted carbon monoxide detector. 11 Curtains should not be hung above the appliance. Operation of the fire 1 It should be noted that your fire is fitted with a Flame Supervision Device, which cuts off the gas supply to your fire if, for any reason the pilot light is extinguished. The pilot flame heats the thermocouple probe and allows gas to flow to the burners. If due to pilot failure, the thermocouple cools, no gas will flow to the main burner. If the fire is turned off or the flames go out, wait for AT LEAST 3 MINUTES before attempting to relight the fire. 2 The power supply to the appliance should be left on at all times as the appliance is fitted with a fan to increase the circulation of convicted air. The fan will operate when the interior temperature has reached approximately 50ºC. The fan has two speed settings which are controlled by a switch located beside the gas control. The lowest position is slow and the upper position is fast. The fan may be run at whatever speed the user finds most appropriate. Once the fire has been switched off, the fan will continue to run until the interior temperature reduces to 37ºC. The fire is to be used with the circulation fan turned ON. The control knob should be set to MIN to avoid the appliance overheating. 10

FIG. 7 Lighting the Appliance 1 Open the louvered door at the base of the appliance under the glass door by pulling on the top edge at the sides. 2 Push in and turn the control knob anti-clockwise to the PILOT position. 3 Hold the knob in for several seconds to purge any air from the system. 4 With the knob still depressed turn it from the "OFF" position to the "PILOT" position until the pilot light ignites Continue to depress the control knob for a further 10-15 seconds. Release the control knob, the pilot should stay alight. If the pilot flame goes out, repeat the process, holding down the control knob for a slightly longer period. 5 Depress the control knob slightly and turn anti-clockwise to the MAX position. The main burner should now light. 6 Turn the control knob clockwise to the MIN position. The flames will get lower but the main burner should remain alight. 7 Depress the control knob slightly and turn clockwise to the PILOT position. The main burner should go out but the pilot flame should remain alight. 8 Depress the control knob slightly and turn clockwise to the OFF position. The pilot flame should go out. IMPORTANT: After turning OFF, or if the pilot burner or main burner go out for any reason, wait 3 minutes before attempting to relight. Turning the fire off. 1. Slightly depress the control knob and turn clockwise to the "PILOT" position. The main burner will go out but the pilot will remain alight. 11

2. Depress the control knob and turn clockwise to "OFF". The fire is now turned off completely. REMOTE CONTROL ELECTRONIC IGNITION SYSTEM Igniting the Appliance. Simultaneously press the (Spark) OFF and or big flame buttons of the receiver for ignition. (Fig-A). An acoustic signal indicates that the start sequence has begun. The electronic system then checks that the main gas is flowing and ignites the main burner; this may take up to 20 seconds. IMPORTANT: During the lighting procedure the main valve button must be in the ON position. (Fig-B). Remember if you are trying to light the fire with your remote control and there is no acoustic signal or the pilot light does not ignites, change the batteries in the remote control and the receiver. The receiver box is located in the lower part of the insert in a box, next to the speed switch. In order to change the batteries of the receiver you will have to loose a screw. (Fig-C). Adjusting the Heat Setting You are now able to use the remote control. To increase the flame, the top button ( or big flame ) should be depressed. Pressing the lower button ( or small flame) on the handset will reduce the flame. It is also possible to turn the main burner all the way down so that it is effectively off, leaving only the pilot ignited. You can control the fan speed with help of the ventilator switch. (Fig-D). Fig-A Fig-B Fig-C Fig-D Extinguishing the Appliance Fully From any heat setting, press the OFF button for a few seconds. This will cause the burner to fully extinguish. IMPORTANT: After turning OFF, or if the pilot burner or main burner go out for any reason, wait 3 minutes before attempting to relight. There is a internal mechanism that will block it during some minutes. 12

Remote control with climate control system (depending the gas fire model) Display setting After having changed the batteries, press the symbols (OFF) and ( ) and select ºF/12 hours or ºC/24 hours. Hour setting For the selection of the hour you have to press ( ) and ( ). Once the screen light you can proceed to the hour ( ) and ( ) minutes setting. Setting of the temperature Press SET and select or C (Temperature day or night). Once choose the option press SET till it flickers. Then adjust the temperature pressing ( ) or ( ). (Fig.1). Setting the timer Press SET alternatively till the option TIMER appears. Keep pressing SET till it flickers. The program 1 (P1), set the lighting and C switch it off. In both options you an adjust the time by pressing ( ) or ( ). For the second program (P2) proceed the same way. (Fig.2) Fig. 1 Fig.2 Fig.3 Please note it is advised to replace the batteries yearly,on the remote and receiver, whilst servicing the appliance. Cleaning the fire Ensure that the appliance is cool. Regular dusting with a dry cloth is usually all that is necessary to keep your fire looking at it's best. From time to time it may be necessary to clean the steel surface with a slightly damp cloth - do this while the fire is cool and ensure that no water remains on the appliance surface. Glass. Let the fire and glass cool completely. Only the outside of the glass can be cleaned by the user. Wash the glass with warm water, using a soft paper towel or cloth, rinse and dry thoroughly. Never use abrasive or harsh chemicals to clean the glass. For stubborn deposits use a cleaner available from your dealer. Do not allow the cleaner to touch any brass ornamentation. 1 Ensure that the fire is cold before undertaking any cleaning. Remember that heat is retained for some time after the fire is switched off. In normal use your fire requires only minimal cleaning. Some soot may form on any ceramic pieces placed in the flames but this is generally harmless unless an excessive amount is deposited. 2 If large pieces of debris are found in the fire, sufficient to alter the appearance or operation of the appliance, the chimney / flue should be inspected and the appliance serviced before further use. 3 In any event, the chimney should be checked annually to ensure continued clearance of the combustion products and that there is no excessive build-up of soot. 13

Troubleshooting Pilot sparks but does not light No gas to fire, check isolators are open. Pipework blockage, clean out. Air not fully purged, repurge supply or wait longer. Spark earthing to metal work, reset gap correctly. Check for spilled ceramics in pilot area. Blocked pilot, clean out internally. Pilot lights but then goes out Severe restriction in gas supply, clear obstruction. Faulty thermocouple, replace pilot unit. Hold control knob in for longer. Check control knob does not foul control plate. Fire does not spark at pilot HT lead detached, refit. Spark gap too large or small, reset correctly. Faulty piezo unit, replace. Debris shorting out electrode, clean. Fire runs for a time and then cuts off Excessive room draught or flue pull, rectify. Loose or faulty thermocouple, rectify. TTB system in operation. Lint in pilot aeration hole, clean thoroughly internally Pilot flame shrinks when fire is on high Poor gas flow to fire, check pressure with fire on high. If pressure is low, remove any restriction in pipework or valve. Check all isolators are adequately sized and fully open. Check meter pressure is adequate. Lint in pilot aeration hole, clean thoroughly internally. Fire smells when first lit or in use Newness smell from brand new appliance. Spillage occurring. Carry out spillage test and rectify any problems. Low temperature sealants or combustible materials used in incorrect positions Failure of the fire not lighting remotely, may require new batteries been fitted to the hand set and receiver. It is recommended to replace the batteries when the fire is been serviced on a yearly basis. Guarantee The guarantee is valid for a period of 2 years from the purchase date. This guarantee does not cover parts normally subject to wear or which last less than the aforementioned Guarantee period, as thermocouples, batteries, gaskets, painted parts, logs or stones. The ceramic glass is not included in the guarantee. The guarantee will be invalided by incorrect installation or misuse of the appliance. During this period the Dealer undertakes to repair or replace the faulty parts. Such repairs shall not alter the date of expiry of the Guarantee. AMBIFUEGO RESERVES THE RIGHT TO MODIFY OR UPDATE ITS PRODUCTS OR SPECIFICATIONS WITHOUT PRIOR NOTICE, AS ITS POLICY IS ONE OF CONTINUAL IMPROVEMENT. 14