MD6-ES24VK. Installation, Operation, and Maintenance Manual

Similar documents
Installation Instructions

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

DBF 4XL Dryer Booster Fans

Bathroom Exhaust Fan

Easy installation in both new construction and retrofit

HUMIDITY SENSING BATH FAN

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Easy installation in both new construction and retrofit

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

Operator: Save these instructions for future use!

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

breeze easytm model # F100-1W

e Heater/Exhaust Fan/Light User s Guide

VENTILATION FAN / LED LIGHT / LED NIGHT LIGHT

VENTILATION FAN WITH LIGHT AND HEATER

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS. MODEL Pro200/Pro300 TABLE OF CONTENTS. Package Contents. General Safety Information

VENTILATION FAN / LED LIGHT

Please Read and Save These Instructions Safety Information

INTELLIMIST Residential Atomizing Humidifier and Control

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

e Bath Fan with Light User s Guide

RP, GP, XP Pro Series Installation Instructions

Owner s Guide. TrueIAQ Digital IAQ Control

e Bath Fan with Light User s Guide

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

READ AND SAVE THESE INSTRUCTIONS

e Bath Fan with Light User s Guide

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION MANUAL AND USER GUIDE

UNDER CABINET RANGE HOOD

RP / RPc Series Installation Instructions

IN014 Rev P Saber Way, Ward Hill, MA radonaway.com

Installation Instructions Remote Blowers

CVS Model Inline Multi-Port Ventilators

INSTALLATION INSTRUCTIONS Apartment Fan Coil

PLAN THE INSTALLATION Planning the installation first requires selecting the most appropriate installation approach. The chart below offers suggestion

Active Thermal Management. SEC-1 Installation Instructions

LOW VOLTAGE CONTROL CIRCUIT WIRING

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

SF180 Installation Instructions

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

VENTILATION FAN WITH BLUETOOTH SPEAKER

COMBUSTION AIR SYSTEM Model: CAS-3

7-Day. Digital Thermostat. residential. & 2-cool

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

FE1 Series Ventilation Fans 2007 Soleus Air International. Soleus Air Ultra Quiet Ventilation Fan

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

INSTALLATION MANUAL AND USER GUIDE

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS FOR WHOLE HOUSE FANS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR DUCTED WHOLE HOUSE FANS

SAFETY AND INSTALLATION MANUAL MODEL 8100

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS FAN COIL PROGRAMMABLE DIGITAL THERMOSTAT. Meets California Title 24

Bathroom Exhaust Fan/Fluorescent Light Combination

Wiring: All wiring should be conventional 18 gauge thermostat wire. Thermostats and zone dampers may be located up to 300 feet from the Z-300 panel.

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

ZONE PANEL KIT INSTALLATION MANUAL COMMUNICATING ZONE PANEL KIT - (S1-TCZCB01A) ZONE PANEL WITH ZONING TOUCH SCREEN FIRMWARE

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Smart Si Thermostat. Installation Manual

DIGITAL THERMOSTAT. I2:00 Su AUTO OPTIONAL HUMIDITY MODULE

Self-Cleaning Range Hoods

TH8320U and TH8321U Touch Screen Programmable Thermostats

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

MX Series Indoor Modular Blowers ModuleFlex Electric or Hot Water Heat with available Variable-Speed High Efficiency ECM Motor

Installation Instructions

Y8150 Fresh Air Ventilation System, W8150 Fresh Air Ventilation Control

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

INSTALLATION INSTRUCTIONS Venstar Inc. 08/07

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

Transcription:

MD6-ES24VK Installation, Operation, and Maintenance Manual EAD AND SAVE THESE INSTUTIONS The purpose of this manual is to aid in the proper installation and operation of fans manufactured by S&P. These instructions are intended to supplement good general practices and are not intended to cover detailed instruction procedures, because of the wide variety and types of fans manufactured by S&P. 6393 Powers Ave Jacksonville, FL 32217 P: 800.961.7370 F: 800.961.7379 MD6-ES24VK-IOM_v.2 / 09-2018

Installation Instructions MD6-ES24VK 1. WANINS EAD AND SAVE THESE INSTUTIONS. FAILUE TO OMPLY WITH INSTUTIONS OULD ESULT IN PESONAL INJUY AND/O POPETY DAMAE! AUTION: (1) For eneral Ventilating Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors. (2) The MD6-ES24VK is suitable for operation within indoor environments only. WANIN: TO EDUE THE ISK OF FIE, ELETI SHOK O INJUY, OBSEVE THE FOLLOWIN: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, efrigeration and Air onditioning Engineers (ASHAE), and the local code authorities. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 2. PE-INSTALLATION INSPETION The MD6-ES24VK has been manufactured in accordance with rigorous standards of production. All the components have been checked and tested at the end of the manufacturing process. We recommend that you check the following after receiving this product: 1. The correct size has been received. 2. The correct model has been received. 3. The details on the rating label correspond to the electrical supply: voltage, frequency etc. emove the unit from packaging and inspect for shipping damage within 15 days of receipt. If the product is found to be damaged, immediately contact your local authorized supplier. DO NOT OPEATE THE UNIT IF DAMAED. These instructions should be considered as a supplement to EPA standard practices, as well as all state and local building code regulations. Before installing the product check the following points: 1. The damper blade opens and closes freely. 2. There are no obstructions to the airflow. 3. ENVIONMENT The MD6-ES24VK IS suitable for operation within indoor environments only. The MD6-ES24VK is suitable for the supply of both conditioned and un-conditioned airstreams within the temperature ranges (inclusive of duct airstream s temperature) of -40 up to +60. 1

4. MOUNTIN hoose a mounting location which allows convenient wiring and maintenance accessibility. The MD6-ES24VK can be mounted in any orientation, horizontal or vertical, and is suitable for supply/fresh air applications. The 6 MD6 motorized damper will be installed between the fresh air wall cap/roof cap/soffit vent (with insect screen) and the HVA unit return duct. The ES24V fresh air control can be mounted: On the 6 insulated ductwork between the wall cap and the MD6 motorized damper, or (Note, the 24V power wires ( & ) will need to be extended from the HVA unit power supply or a separate 120V-24V transformer) On the HVA unit (Note, the temperature (26AW cable) and humidity (6P6 phone cable) sensor wires will need to be extended.) 2

Make sure the temperature and humidity sensors are installed into the 6 insulated fresh air duct between the wall cap and MD6 motorized damper if necessary. 5. DUTIN All ducting and fresh air intake construction/location must comply with local and national building codes. Do not locate fresh air intakes near contaminant sources (ex: dryer exhaust vent, garbage, etc). onnect the ductwork to the wall cap and HVA return duct with screws, cable ties, worm clamps, and rated tape as necessary. Ensure that the ductwork is properly connected to a properly sized, low restriction fresh air intake with weather hood and insect screen. S&P recommends round 6 insulated rigid ductwork for best air and sound performance. ound 6 flexible ductwork is acceptable, but ensure that it is pulled tight to reduce losses. Keep the length of duct and number of elbows to a minimum for best air and sound performance. Insulated ductwork will minimize building heat loss/gain and reduce the potential for condensation. The ducting from the HVA unit fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Ductwork connections and penetrations should be sealed with duct tape, duct fast-clamps, or caulk (available through your local distributor) to create an air-tight path from the building exterior to the ventilated space. 6. WIIN AUTION: Ensure that power is turned off and locked out before making any wiring connections. The MD6-ES24VK operates from a standard 24V 60Hz A electrical supply. There are multiple wiring scenarios available depending on the installer preferences. The diagrams below show 3 common scenarios where the ES24V is connected either directly to the HVA unit transformer or an auxiliary transformer and the MD6 is connected either directly to the ES24V damper terminals or to the ES24V damper terminals through a SPST, N.O. 24V relay and transformer. This will depend on the VA available from the HVA unit transformer. S&P recommends 20VA be available to operate the MD6 motorized damper. If 20VA is not available from the HVA unit transformer, then an auxiliary transformer to power the ES24V and MD6 is recommended (transformers and relays provided by others). All wiring must be carried out by a qualified electrician in accordance with National Electrical ode and all applicable state and local buildings codes. Electrical connections should be made in accordance with the following Figures: 1-3 3

TS TS TS TS SENSO SENSO SENSO SENSO OMMON TANSFOME ES24V - (20VA EQUIED TO OPEATE MD6 MOTOIZED DAMPE. LASS II POWE SUPPLY AN OME FOM HVA TANSFOME, IF ADEQUATE, O AUXILIAY TANSFOME IF NEESSAY) FIUE 1 ES24V - (20VA NOT AVAILABLE FO DIET ONNETION OF MOTOIZED DAMPE) FIUE 2 TS TS SENSO SENSO TANSFOME OMMON ES24V - (20VA NOT AVAILABLE FO DIET ONNETION OF MOTOIZED DAMPE) FIUE 3 efer to the ES24V Envirosense Ventilation ontrol IOM on pages 8-9 for ES24V wiring connections and operation. 4

7. AIFLOW SETTIN AUTION: efer to local and national Ventilation and Indoor Air Quality standards to ensure the proper airflow rate. Ensure the HVA unit air filter is clean and installed. Turn the ES24V to the ON position and wait approximately 10 seconds for the HVA unit fan to turn on and the MD6 motorized damper to open. (Note, ensure that the Motorized Damper is enabled on the ES24V, refer to ES24V IOM on page 8-9). Using a manometer, measure and record the airflow through the fresh air duct (refer to the manometer instructions). Once complete, turn the ES24V to the OFF position and calculate the required continuous FM based on the ventilation code. ASHAE 62.2-2010 equired ontinuous FM = ((0.01 * Floor Area in ft²) + 7.5(# of bedrooms + 1)) Example: 2,000 sqaure foot dwelling 3 bedrooms = 50 FM continuous ASHAE 62.2-2013 & 2016 equired ontinuous FM = ((0.03 * Floor Area in ft²) + 7.5(# of bedrooms + 1)) Example: 2,000 sqaure foot dwelling 3 bedrooms = 90 FM continuous Now that the required continuous FM is known, calculate the required run time / hour. un Time / Hour = 60 * (equired ontinuous FM / Actual Measured FM) Example (based on ASHAE 62.2-2010 example above): 50 equired ontinuous FM 150 Actual Measured FM = 20 minutes / hour Set the ES24V to the correct un Time / Hour and High / Low Temperature & Humidity limits per the ES24V IOM on pages 8-9. 5

Airflow / Air Velocity eference Table Airflow (FM) Duct Size (in) 6 7 8 Air Velocity (FPM) 30 153 112 86 40 204 150 115 50 255 187 143 60 306 225 172 70 357 262 201 80 407 299 229 90 458 337 258 100 509 374 286 110 560 412 315 120 611 449 344 130 662 486 372 140 713 524 401 150 764 561 430 160 815 599 458 170 866 636 487 180 917 674 516 190 968 711 544 200 1019 748 573 Note, if the Actual Measured FM is not enough, the installer may need to increase the duct size or add a booster fan if necessary. Ensure there is no blockage in the ductwork first. 9. MAINTENANE AUTION: BEFOE AYIN OUT ANY MAINTENANE O SEVIIN, ENSUE THE UNIT IS DISONNETED FOM THE MAIN ELETIAL SUPPLY. S&P recommends inspection of the MD6 and ES24V at least once every twelve (12) months. To inspect the unit disconnect from electrical supply. emove the MD6 motorized damper from the fresh air ductwork and inspect the damper blade for damage and proper function. If any debris is evident on the damper blade clean with a damp (not wet) cloth. DO NOT USE any detergents or abrasive materials for cleaning. einstall MD6 motorized damper to the fresh air ductwork and reseal joints. 6

11. WAANTY S&P USA - S&P anada warrant that the MD6-ES24VK will be free from defective materials and workmanship for the period of (5) years from the date of original purchase. In the event that we find any part is defective the product will be repaired or, in the ompany s discretion, replaced without charge provided that the product has been installed in accordance with the enclosed instructions and all applicable EPA Standards and state and local building codes. IF LAIMIN UNDE WAANTY: Please return the complete product, freight paid, to your local authorized distributor. All returns must be accompanied by a valid Bill Of Sale. All returns must be clearly marked Warranty laim, with an accompanying description stating the nature of the fault. THE FOLLOWIN WAANTIES DO NO APPLY: Damages from shipping, either concealed or visible. laim must be filed with the carrier. Damages resulting from improper wiring or installation Damages caused by acts of nature, or resulting from improper consumer procedures such as: Improper Maintenance; Misuse; Negligence; Alteration; Abuse; Abnormal Use; or Accident or Incorrect Electrical Voltage and urrent. emoval or alteration to the S&P USA - S&P anada data plate label. WAANTY VALIDATION: The end user must keep a copy of the Bill of Sale to verify purchase date. THE ABOVE (5) YEA WAANTY IS EXPESSLY IN LIEU OF ALL OTHE WAANTIES, EXPESSED, WITTEN O IMPLIED, INLUDIN THE WAANTIES OF MEHANTABILITY AND FITNESS FO USE. IN NO EVENT SHALL Soler & Palau USA - Soler & Palau ANADA BE LIABLE FO ANY SPEIAL, ONSEQUENTIAL, O INIDENTAL DAMAES, INLUDIN LOSS OF POPETY, EVENUES, LOST POFITS, OSTS OF EMOVAL, INSTALLATION O EINSTALLATION. 7

ES24V Envirosense Ventilation ontroller The ES24V controls a ventilator to meet fresh air supply requirements while limiting operation during periods of extreme temperature and/or humidity. INSTALLATION & OPEATION MANUAL AUTION: 1. EAD AND SAVE THESE INSTUTIONS. 2. Before installation or maintenance, disconnect the power supply. 3. This control is for 24 VA applications only. 4. All wiring must be done by qualified person(s) in accordance with all applicable codes & standards. WIIN Use opper onductors Only Terminal Type Description 24Vac Input: 24Vac input (50/60 Hz) 24Vac Input: 24Vac common 24Vac Input: Furnace Blower (Optional) B 24Vac Output: Furnace Blower (2A max) (Optional) F+ 24Vac Output: Fresh Air Fan output + (2A max) F- 24Vac Output: Fresh Air Fan output - (2A max) D+ 24Vac Output: Motorized Damper + (2A max) (Optional) D- 24Vac Output: Motorized Damper - (2A max) (Optional) H+ 24Vac Output: Duct Heater output + (2A max) (Optional) H- 24Vac Output: Duct Heater output - (2A max) (Optional) MOUNTIN Front over emoval Insert a flathead screwdriver into the slot on the right side of the controller and apply gentle pressure inward and up so that the front cover disengages from the back cover. Pull the front cover up and to the left. Back over Mounting Locate the control on the mounting surface being sure to allow clearance for the necessary wiring connections. Mark the mounting hole locations and remove the back cover from the work space. Make the stripped/labelled wiring connections now. AUTION: Be sure that no exposed portions of wires are touching. If installing onto wood, mount the back cover with the provided screws. If installing onto drywall, drill pilot holes using a 7/32 drill bit (not provided) and tap the provided drywall anchors into place. Mount with provided screws. NOTE: Velcro can be used to mount the control instead of screws if necessary. Verify that wiring connections are correct and secure. Align the front cover with the back cover starting on the left side. Push the front cover towards the back cover in a hinging motion from the left to the right. AUTION: Make sure the front cover is aligned properly with the back cover to avoid damaging the control. Press down until the front cover snaps securely into place. Sensor Mounting The ES24V comes with a temperature sensor (26AW, 2 wire) and humidity sensor (6P6, telephone wire), both 10 long. Install the sensors at a location so that they will be exposed to the fresh air intake (ex: the fresh air ductwork). Drill 2, 3/4" diameter holes, spaced appropriately and install the sensors with the provided hardware. NOTE: the sensor wires can be extended up to 300 feet without deviation. Use appropriate duct tape to seal joints/openings as necessary. DIMENSIONS (in) SEEN DIAAM Operating Modes: OFF, ON, or Eco Motorized Damper indicator elative Humidity % Temperature (F or ) Fresh Air Fan indicator Thermostat integration indicator Duct Heater indicator OPEATIN MODES OFF Mode: All outputs are off. ON Mode: The Fresh Air Fan, Motorized Damper (if enabled), and Furnace Blower (if enabled) are on continuously. The Duct Heater will follow the user settings (see FUNTION SETTINS below). Eco Mode: Eco Mode limits the Fresh Air Fan operation during periods of extreme temperature and/or humidity. The Fresh Air Fan, Motorized Damper (when enabled), Furnace Blower (when enabled), and Duct Heater (when enabled) will follow the user settings when the outside air temperature/humidity is within the user set limits (see FUNTION SETTINS below). The Fresh Air Fan will run for the user set amount of time/hour while the temperature/humidity limits are within range. The temperature/humidity sensors evaluate the fresh air conditions every 10 seconds. While the fresh air temperature/humidity is within the user set limits, the Fresh Air Fan/accessories will run per the user settings. When the fresh air temperature/humidity exceeds the user set limits, the Fresh Air Fan/accessories will turn off and engage a timer. The timer will run the fan for 5 minutes every 15 minutes in order to meet code requirements. NOTE: the Furnace Blower (if enabled) will not run during this check procedure to prevent cycling. The fan will continue this check procedure until the temperature/humidity limits are within the user set limits. If Enabled (in SETUP): The Furnace Blower will be on: any time there is a call from Input or any time the Fresh Air Fan is on (excluding the check procedure above). The Motorized Damper will be on anytime the Fresh Air Fan is on. The Duct Heater will be on any time the Fresh Air Fan is on and the set point > room temperature +2 F. (Motorized Damper, Furnace Blower, and Duct Heater are required to be enabled in SETUP) BUTTONS Keys Description Mode Select the operating mode Set onfirm settings Increase settings Decrease settings 8

SETUP Press and hold [MODE] for 3 seconds to enter setup mode. O 01 Optional Duct Heater (Default: heater disabled) Press [ ]/[ ] to enable or disable duct heater. O 02 Temperature Unit (Default: degrees F) Press [ ]/[ ] to select degrees or degrees F. O O 03 Humidity/Temperature (Default: temperature and humidity) Press [ ]/[ ] to evaluate temperature only, humidity only or both temperature and humidity. O 04 Optional Motorized Damper (Default: motorized damper disabled) Press [ ]/[ ] to enable or disable motorized damper. O 05 Optional Thermostat Integration (Default: standalone system) Press [ ]/[ ] to enable or disable thermostat integration. 06 Fan un Time per Hour (Default: 15 minutes) Press [ ]/[ ] to adjust 5-60 Minutes/Hour (Increments of 5). Press [SET] to confirm settings and return to normal mode. All setting screens will return to the normal mode screen automatically after 20 seconds. FUNTION SETTINS Press <Set> key to set the temperature/humidity limits and duct heater set point. Press [ ]/[ ] to change the high limit temperature setting. Press [ ]/[ ] to change the high limit humidity setting. Press [ ]/[ ] to change the low limit temperature setting. Press [ ]/[ ] to change the low limit humidity setting. Press [ ]/[ ] to change the duct heater activation temperature setting. Press [SET] to confirm settings and return to normal mode. FATOY ESET Press and hold [ ]&[ ] buttons in OFF mode for ~5 seconds to reset the control to factory settings. will be displayed on the screen when complete. FEATUES Voltage supply: 24VA +/- 15% 50/60Hz System mode: Off / On / Eco Temperature unit mode: F or Temperature measurement range: 15 F - 130 F (-10 to 55 ) High Limit Temperature settings range: 65-105 F (18 to 40 ) Low Limit Temperature settings range: 20-60 F ( -6 to 16 ) Heater Temperature settings range: 32 F - 62 F (0-16 ) Temperature resolution: 1 F or 0.5 Temperature Accuracy: +/-1 F or 0.5 Humidity measurement range: 10-95% High Limit Humidity settings range: 55-90% Low Limit Humidity settings range: 10-50% Humidity resolution: 1 % Humidity Accuracy: +/- 5 % 10 inch J11 (6 wires) phone cable for humidity sensor 10 inch 26AW (2 wires) cable for temperature sensor Max Sensor Wire Length: 300 feet (100 m) Motorized Damper relay output (Maximum 2A) Fan relay output (Maximum 2A) Duct Heater relay output (Maximum 2A) Furnace Blower Output (Maximum 2A) Non-volatile memory to store settings, configuration parameters Operating temperature: 15 F to 130 F (-10 to 55 ) Storage temperature: -20 F to 158 F (-29 to 70 ) Temperature limit of mounting surface: 130 F (55 ) Terminals: 2.5mm 2 cable Pollution Degree: 2 Degree of protection: IP20 Electronic control: Type 2.B lass II ontrol culus listed: UL60730-1 Housing Material: Lexan 943(f1), 1.6mm thick, V-0 (UL94 ating) Time Setting ange: 5-60 Minutes Power: 1.5W (Max) 180129 9