Fan Coils & Air Handlers Product Catalog

Similar documents
TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils

PRODUCT CATALOG. Aspen Manufacturing - Evaporator coils - Air Handlers - Manufactured Home Products - Light Commercial Coils

AIR HANDLERS AIR HANDLERS

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

HIGH EFFICIENCY AIR HANDLER

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

DEDICATED VERTICAL/WALL MOUNT

Field Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.

AVPTC. Air Handlers 1½ to 5 Tons

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

TECHNICAL SPECIFICATIONS B6VMMX

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

AVPTC Multi-Position, Internal Txv

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

CWA4 Chilled & Hot Water Fan Coil

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Specifications. Vertical Floor Consoles By First Co.

Ruud Standard Efficiency Air Handler

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

Ruud Standard Efficiency Air Handler

Cooling/Heat Pump Convertible Air Handlers

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Bosch BVA Series Air Handler

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

INSTALLATION GUIDE. GFT/GFS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction. 2.

INSTALLATION AND OWNERS MANUAL

MERIT SERIES Up Flow / Horizontal

Cooling/Heat Pump Convertible Air Handlers

INSTALLATION GUIDE. AAM and AEM Series - Multi-Position Air Handler (Electric Heat) ! WARNING ! CAUTION. 1. Safety Instruction. 2.

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

INSTALLATION GUIDE. AFM Series - Multi-Position Air Handler (Hydronic Heat) 1. Safety Instruction. 2. Introduction !

Rheem Standard Efficiency Air Handler

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

DH SERIES HORIZONTAL DIRECT DRIVE CHILLED WATER/DX AIR UNITS. OPTIONAL ACCESSORIES Two Row Hot Water Coil

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

HIGH EFFICIENCY AIR HANDLER

Upflow/Downflow A-Coil Specifications

Modular Multi-position Air Handler

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Bosch BVA Series Air Handler

Rheem High Efficiency Air Handler

AVPTC Multi-Position, Internal Txv

WAHL A Product Specifications

FEM4X. Product Specifications FAN COILS /14/15

AVPTC. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

INSTALLATION GUIDE. AEC & AAC Series - Ceiling Mount Air Handler (Electric Heat) 1. Safety Instruction. 2. Introduction !

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

GFM SERIES INSTALLATION & OPERATING INSTRUCTIONS HIGH EFFICIENCY X13 MULTI-POSITION AIR HANDLER (HYDRONIC HEAT)

Cooling/Heat Pump Convertible Air Handlers

Hydronic Air Handler Powered by Tankless Technology

Vertical Upflow Horizontal Left Air Handlers

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Condensing Units & Air Handlers

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

AVPTC Multi-Position, Internal Txv

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

GUIDE SPECIFICATIONS AQUARIUS ii

INSTALLATION GUIDE. GBT/GBS Series - Cased/Uncased Ceiling Mount Hydronic Heat Dx Cool Air Handler ! WARNING. 1. Safety Instruction

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

CB X 32 mv

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

GBW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (HYDRONIC HEAT)

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

INSTALLATION GUIDE. GAT & GAS Series - Horizontal Ceiling Mount Electric Heat Dx Cool Air Handler ! WARNING ! CAUTION. 1. Safety Instruction

INSTALLATION INSTRUCTION

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

GAW SERIES INSTALLATION & OPERATING INSTRUCTIONS VERTICAL WALL MOUNT AIR HANDLER (ELECTRIC HEAT)

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Transcription:

Fan Coils & Air Handlers Product Catalog

120V/240V motors PSC and ECM high efficiency constant torque motors Heavy-gauge, galvanized steel construction High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer Compatible with most brands of air conditioners or heat pumps. Easy slide-out blower and coil assembly for installation and service 100% factory leak and performance tested ETL Certified Ceiling Mount Cased and uncased options available Electric and hydronic heating Can be ordered with or without pump Cooling Capacity (Tons): 1.5, 2.0, 2.5, 3.0 Electric Heat (Kw): 0, 3, 5, 6, 8, 10 Hydronic Heat : Up to 51,000 BTUH HW heat Multi-Position & Wall Mount Electric and hydronic heat DX Cool Modular electric and hydronic heat kits (can be ordered separately) with or without pump. Multi-Position Cooling Capacity (Tons): 1.5-5.0 Wall Mount Cooling Capacity (Tons): 1.5, 2.0, 2.5, 3.0 Electric Heat (Kw): 0, 3, 5, 6, 8, 10 Hydronic Heat: Up to 116,300 BTUH HW heat Ratings AirMark products are certified to meet the U.S. Department of Energy (DOE) requirements. Capacity and SEER values are calculated using the methodology in Section 430.23(M) of 10CFR Part 430. The calculation procedure utilizes test data collected in accordance with ANSI/AHRI 210/240-2008 and has been validated by an independent test in accordance with DOE standards.

To Place an Order 1. All orders MUST include the following information: ü ü ü ü Please address all AirMark orders to: APK Manufacturing LLC Unique quote reference number Account # & P.O.# Requested ship date If none, order will be placed and shipped ASAP ü COMPLETE model #, including Option Codes if standard, fill in the spaces with 000 ü ü Contact name, phone and e-mail MUST include all three. ANY notes regarding special pricing, terms, shipping etc. with supporting documentation. 2. Send Order To: Email orders: orderentry@airmark-ac.com Fax orders: (281) 441-6510* *Alternate Fax (281) 441-1863 is available if difficulties are encountered with primary Fax number. If faxing an order, it is customer s responsibility to confirm order placement. Email orders are encouraged and preferred. Phone orders not accepted. To Obtain a Quote Call Your Local Sales Representative APK Manufacturing LLC 373 Atascocita Road Humble, TX 76396 800.423.9007

NOMENCLATURE 4 MULTI-POSITION 5 GAM SERIES (PSC, ELECTRIC)...5 GBM SERIES (PSC, HYDRONIC)...9 GEM SERIES (X13, ELECTRIC)... 12 GFM SERIES (X13, HYDRONIC)... 16 WALL MOUNT 20 GAW SERIES (PSC, ELECTRIC)... 20 GBW SERIES (PSC, HYDRONIC)... 24 GEW SERIES (X13, ELECTRIC)... 28 GFW SERIES (X13, HYDRONIC)... 32 CEILING MOUNT 36 GAS SERIES (PSC, ELECTRIC, UNCASED)...36 GAT SERIES (PSC, ELECTRIC, CASED)...40 GBS SERIES (PSC, HYDRONIC, UNCASED)...44 GBT SERIES (PSC, HYDRONIC, CASED)...47 GES SERIES (X13, ELECTRIC, UNCASED)...50 GET SERIES (X13, ELECTRIC, CASED)...54 GFS GFT SERIES (X13, HYDRONIC, UNCASED)...58 SERIES (X13, HYDRONIC, CASED)...61 Copyright 2017 APK Manufacturing. All rights reserved. ARMK1-1117

NOMENCLATURE G Series Air Handler Nomenclature G A M 18 G -000 AirMark Air Handler Voltage A = 240V PSC Motor B = 120V PSC Motor E = 240V Constant Torque EC Motor F = 120V Constant Torque EC Motor Configuration M = Multi-Position T = Cased Ceiling Mount S = Uncased Ceiling Mount W = Wall Mount Nominal tonnage (MBTUH) Metering Device 4 = non-bleed A/C or H/P R410 TXV F = R-22 Flo-rater 6 = 20% bleed A/C or H/P R410 TXV G = R-410A Flo-rater B = 20% bleed A/C or H/P R22 TXV X = non-bleed A/C or H/P R22 TXV Option Code Electric Heat Kit Nomenclature E C S 10 E = Fits GAM, GEM Series F = Fits GAW, GEW H = Fits GAS, GAT, GES*, GET* Power Connection 3 = 3-phase Circuit Breaker P = Circuit Breaker W/Single Point Block 4 = 3-phase Terminal Block T = Terminal Block C = Circuit Breaker L = Large Cabinet (42-61) S = Small Cabinet (18-36) Heat Strip 00 = NO Heat 08 = 8 KW 20 = 20 KW 03 = 3 KW 10 = 10 KW 24 = 24 KW (3-phase Circuit Only) 05 = 5 KW 12 = 12 KW (3-phase Circuit Only) 25 = 25 KW 06 = 6 KW 15 = 15 KW 30 = 30 KW Hydronic Heat Kit Nomenclature W C 2 S P W = Fits GBM, GFM Series U = Fits GBW, GFW Z = Fits GBS, GFT, GBS, GFT Power Connection 3 = 3-phase Circuit Breaker C = Circuit Breaker T = Terminal Block Hydronic Coil Rows 2 3 4 Coil Dimensions L = Fits Large Chassis (42, 48, 60, 61) S = Fits Small Chassis (18, 24, 30, 36) Pump L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 4 Please refer to individual product specifications for additional details and a list of available options and accessories.

GAM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA MULTI-POSITION ELECTRIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications MULTI-POSITION GAM Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 01/24/17 2017 AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. 3-speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on rails so they can be easily removed for service. 1 DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. Drain pan is UV safe. Galvanized metal drain pan (on 60/61 models only) with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 5

MULTI-POSITION GAM MODEL GAM 18/19+ GAM 24/25 + GAM 30/31 + GAM 36/37 + GAM 42/43 + GAM 48/49 + GAM-60/61 + HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT HEATING CAPACITY (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V E(C,T)S00 0.0 0.0 1.6 1.8 15.0 15.0 E(C,T)S03 7.8 10.2 15.6 17.4 20.0 20.0 E(C,T)S05 13.0 17.1 24.6 27.8 30.0 35.0 E(C,T)S06 15.4 20.5 28.8 33.0 35.0 40.0 E(C,T)S08 20.8 27.3 38.4 43.4 45.0 50.0 E(C,T)S10 25.9 34.1 47.4 53.8 60.0 60.0 E(C,T)S00 0.0 0.0 1.6 1.8 15.0 15.0 E(C,T)S03 7.8 10.2 15.6 17.4 20.0 20.0 E(C,T)S05 13.0 17.1 24.6 27.8 30.0 35.0 E(C,T)S06 15.4 20.5 28.8 33.0 35.0 40.0 E(C,T)S08 20.8 27.3 38.4 43.4 45.0 50.0 E(C,T)S10 25.9 34.1 47.4 53.8 60.0 60.0 E(C,T)S00 0.0 0.0 2.9 3.3 15.0 15.0 E(C,T)S03 7.8 10.2 17.1 18.9 20.0 20.0 E(C,T)S05 13.0 17.1 26.1 29.3 30.0 35.0 E(C,T)S06 15.4 20.5 30.3 34.5 35.0 40.0 E(C,T)S08 20.8 27.3 39.9 44.9 45.0 50.0 E(C,T)S10 25.9 34.1 47.1 53.3 60.0 60.0 E(C,T)S15 38.6 51.2 48/23 56/27 50/25 60/30 E(C,T)S00 0.0 0.0 2.9 3.3 30.0 35.0 E(C,T)S03 7.8 10.2 17.1 18.9 35.0 40.0 E(C,T)S05 13.0 17.1 26.1 29.3 45.0 50.0 E(C,T)S06 15.4 20.5 30.3 34.5 60.0 60.0 E(C,T)S08 20.8 27.3 39.9 44.9 45.0 50.0 E(C,T)S10 25.9 34.1 48.9 55.3 50.0 55.0 E(C,T)S15 38.6 51.2 48/23 56/27 50/25 60/30 E(C,T)L00 0.0 0.0 5.0 5.5 15.0 15.0 E(C,T)L03 7.8 10.2 19.3 21.1 25.0 30.0 E(C,T)L05 13.0 17.1 28.3 31.5 35.0 40.0 E(C,T)L06 15.4 20.5 32.5 36.8 40.0 45.0 E(C,T)L08 20.8 27.3 42.2 47.2 50.0 60.0 E(C,T)L10 25.9 34.1 49.4 55.5 60.0 60.0 E(C,T)L15 38.6 51.2 48/23 56/27 50/25 60/30 E(C,T)L20 51.2 95.6 49/45 58/52 60/60 60/60 E(C,T)L25 64.2 85.3 49/45/23 58/52/26 50/50/30 60/60/30 E(C,T)L30 76.8 102.4 49/45/45 58/52/52 50/50/50 60/60/60 E(C,T)L00 0.0 0.0 5.0 5.5 15.0 15.0 E(C,T)L03 7.8 10.2 19.3 21.1 25.0 30.0 E(C,T)L05 13.0 17.1 28.3 31.5 35.0 40.0 E(C,T)L06 15.4 20.5 32.5 36.8 40.0 45.0 E(C,T)L08 20.8 27.3 42.2 47.2 50.0 60.0 E(C,T)L10 25.9 34.1 49.4 55.5 60.0 60.0 E(C,T)L15 38.6 51.2 48/23 56/27 50/25 60/30 E(C,T)L20 51.2 95.6 49/45 58/52 60/60 60/60 E(C,T)L25 64.2 85.3 49/45/23 58/52/26 50/50/30 60/60/30 E(C,T)L30 76.8 102.4 49/45/45 58/52/52 50/50/50 60/60/60 E(C,T)L00 0.0 0.0 5.0 5.5 15.0 15.0 E(C,T)L03 7.8 10.2 19.3 21.1 25.0 30.0 E(C,T)L05 13.0 17.1 28.3 31.5 35.0 40.0 E(C,T)L06 15.4 20.5 32.5 36.8 40.0 45.0 E(C,T)L08 20.8 27.3 42.2 47.2 50.0 60.0 E(C,T)L10 25.9 34.1 49.4 55.5 60.0 60.0 E(C,T)L15 38.6 51.2 48/23 56/27 50/25 60/30 E(C,T)L20 51.2 95.6 49/45 58/52 60/60 60/60 E(C,T)L25 64.2 85.3 49/45/23 58/52/26 50/50/30 60/60/30 E(C,T)L30 76.8 102.4 49/45/45 58/52/52 50/50/50 60/60/60 2 6

* Wet coil MODEL MODEL AIR HANDLER CHASSIS NOMENCLATURE GAM 18 F -001 GAM = 240V PSC Motor Multi-Position Air Handler NOMINAL COOLING (BTUS) HP AMPS GAM 18/19/24/25 1/5 2.8 GAM 30/31/36/37 1/3 5.4 GAM 42/43/48/49/60/61 3/4 9.5 208/240V- 3 PHASE CIRCUIT BREAKER PERFORMANCE DATA HEATING (KW) Nominal tonnage (MBTUH) HEATING CAPACITY (MBTUH) BLOWER DATA CFM V. EXTERNAL STATIC* VOLTAGE SPEED 0.10 0.20 0.30 0.40 0.50 LOW 835 800 790 750 695 HIGH 915 880 875 825 770 LOW 1130 1100 1050 1000 960 240 HIGH 1410 1350 1280 1200 1160 LOW 1520 1500 1485 1460 1440 MID 1700 1675 1640 1620 1575 HIGH 2060 2020 1980 1935 1885 Metering Device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 204V 208V 204V 208V 204V 208V 204V GAM42-61+E312 9.0 12.0 30.7 40.9 36.0 42.0 40.0 50.0 GAM42-61+E315 42,000 11.3 15.0 38.4 51.2 44.0 50.0 50.0 50.0 48,000 GAM42-61+E324 60,000 18.0 24.0 61.4 81.9 55 50/45 60 50/40 GAM42-61+E330 22.5 30.0 76.8 102.4 44/39 50/45 50/40 50/50 Option Code MULTI-POSITION GAM ELECTRIC HEAT KIT NOMENCLATURE E C S 03 Electric Heat Interruption C = Circuit Breaker T = Terminal Block P = Circuit Breaker w/single Point 3 = 3-Phase Circuit Breaker 4 = 3-Phase Terminal Block S = 18-37 L = 42-61 Heat strip 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 12 = 12 KW 15 = 15 KW 20 = 20 KW 24 24 KW 25 = 25 KW 30 = 30 KW 3 7

MULTI-POSITION GAM Fig 1 DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F G GAM18,19+E* GAM24,25+E* GAM30,31+E* GAM36,37+E* GAM42,43+E* GAM48,49+E* GAM60,61+E* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 40 [102] 40 [102] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 10-1/2 [27] 10-1/2 [27] 10-1/2 [27] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 10-1/4 [26] 16X20 0.055 99 4 12-1/4 [31] 16X20 0.059 100 4 14-1/4 [36] 16X20 0.068 118 4 16-1/4 [41] 16X20 0.074 147 4 16 [41] 20X20 0.080 153 4 18 [46] 20X20 0.084 180 4 20 [51] 20X20 0.092 200 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 4 8

GBM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA MULTI-POSITION HYDRONIC AIR HANDLERS Product Dimensions & Specifications MULTI-POSITION GBM Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/17 2017 AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row. Modules are easily installed in the field using Molex plugs or can be ordered factory-installed. Freeze stat is wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Totally lead free constructed coil. Suitable for potable applications. 1 BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. 3-speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on rails so they can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged GLP drain pan on 60/61 models holds minimal condensate while eliminating the possibility of corrosion. Drain pan is UV safe. All drain connections are 3/4 FPT. Access door allows for coil cleaning. 9

MULTI-POSITION GBM Model HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA Nominal Cooling GBM18/19 18,000 GBM24/25 24,000 GBM30/31 30,000 GBM36/37 36,000 GBM42/43 42,000 GBM48/49 48,000 GBM60/61 60,000 Model Nominal Cooling GBM18/19 18,000 GBM24/25 24,000 GBM30/31 30,000 GBM36/37 36,000 GBM42/43 42,000 GBM48/49 48,000 GBM60/61 60,000 Hydronic Heat Kit Model Rows PERFORMANCE DATA Coil P.D. (FT.WTR.) Heating Capacity BTU/HR Standard pump at 3.5 GPM Nominal Airflow Entering Water Temp 120 140 160 180 W*2SP 2 5.6 17770 24900 32250 39600 W*3SP 3 4.2 21600 30500 39450 48400 W*2SP 2 5.6 20200 28500 36950 45400 W*3SP 3 4.2 25000 35300 45800 56300 W*2SP 2 5.6 22100 31300 40645 49990 W*3SP 3 4.2 27700 39100 50750 62400 W*4SP 4 2.2 31000 43900 57000 70100 W*2SP 2 5.6 23700 33500 43550 53600 W*3SP 3 4.2 29800 42100 54700 67300 W*4SP 4 2.2 33500 47400 61600 75800 W*2SP 2 5.6 30200 42600 55300 68000 W*3SP 3 4.2 36300 51400 65000 78600 W*4SP 4 2.2 43600 61600 77250 92900 W*2SP 2 5.6 31700 44800 58100 71400 W*3SP 3 4.2 38200 54000 67300 80600 W*4SP 4 2.2 45900 64900 81450 98000 W*2SP 2 5.6 32900 46600 60500 74400 W*3SP 3 4.2 39700 56200 70100 84000 W*4SP 4 2.2 47800 67600 84900 102200 PERFORMANCE DATA Hydronic Heat Kit Model Rows Coil P.D. (FT.WTR.) Heating Capacity BTU/HR High Pressure Drop pump at 5 GPM Nominal Airflow Entering Water Temp 120 140 160 180 W*2S8 2 5.6 18700 26400 34150 41900 W*3S8 3 4.2 22900 32300 41750 51200 W*2S8 2 5.6 22600 31600 40550 49500 W*3S8 3 4.2 26900 38000 49150 60300 W*2S8 2 5.6 23900 33800 43800 53800 W*3S8 3 4.2 30100 42500 55100 67700 W*4S8 4 2.2 34000 48000 62300 76600 W*2S8 2 5.6 25800 36500 47350 58200 W*3S8 3 4.2 32800 46300 60000 73700 W*4S8 4 2.2 37200 52600 68200 83800 W*2S8 2 5.6 33200 46800 60650 74500 W*3S8 3 4.2 40500 57300 70850 84400 W*4S8 4 2.2 49000 69300 86450 103600 W*2S8 2 5.6 34900 49300 63900 78500 W*3S8 3 4.2 42750 60450 74825 89200 W*4S8 4 2.2 52000 73500 91725 109950 W*2S8 2 5.6 36600 51800 67150 82500 W*3S8 3 4.2 45000 63600 78800 94000 W*4S8 4 2.2 55000 77700 97000 116300 ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 4.1 15 4.1 15 7.4 15 7.4 15 12.6 15 12.6 15 12.6 15 ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 5.3 15 5.3 15 8.5 15 8.5 15 13.6 15 13.6 15 13.6 15 HYDRONIC HEAT KIT NOMENCLATURE W C 2 S P Water Heat (Hydronic) Interruption C = Circuit Breaker T = Terminal Block Row 2 3 4 S = GBM18-37 L = GBM42-61 L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 2 10

MODEL GBM18/19/24/25 GBM 30/31/36/37 GBM 42/43/48/49/60/61 * Dry coil with filter in place SPEED HP BLOWER DATA AMPS VOLTAGE CFM V. EXTERNAL STATIC* 0.10 0.20 0.30 0.40 0.50 LOW 780 740 700 645 585 1/5 2.8 HIGH 850 800 745 685 620 LOW 1000 980 920 870 800 1/3 5.4 HIGH 120 1210 1190 1160 1130 1070 LOW 1360 1340 1310 1280 1230 MED 3/4 9.5 1530 1470 1420 1360 1310 HIGH 1730 1670 1600 1540 1480 AIR HANDLER CHASSIS NOMENCLATURE GBM 18 F -001 GBM = 120V PSC Motor Multi- Position Hydronic Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F G GBM18/19+W* GBM24/25+W* GBM30/31+W* GBM36/37+W* GBM42/43+W* GBM48/49+W* GBM60/61+W* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 14-3/4 [37] 14-3/4 [37] 14-3/4 [37] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE Option Code SHIP WEIGHT (LBS) SKID QTY 16X20 0.055 99 4 16X20 0.059 100 4 16X20 0.068 118 4 16X20 0.074 147 4 20X20 0.080 153 4 20X20 0.084 180 4 20X20 0.092 200 4 MULTI-POSITION GBM Fig 1 3 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 11

MULTI-POSITION GEM GEM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 01/24/17 2017 AirMark Product Dimensions & Specifications STANDARD FEATURES HIGH EFFICIENCY MULTI-POSITION ELECTRIC HEAT DX COOL AIR HANDLERS APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). For use with either R22 or R410A when proper metering device is used. Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available from 3 to 30 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Fan time delay relay standard for increased efficiency. 1 BLOWER Direct drive blowers circulate air quietly and efficiently. Motor speeds and torques programmed in the motor. Blowers mounted on rails so they can be easily removed for service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged, UV safe, GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. All drain connections are 3/4 FPT. Access door allows for coil cleaning. 12

MODEL GEM18,19 GEM24,25 GEM30,31 GEM36,37 GEM42,43 GEM48,49 GEM60,61 ELECTRIC HEAT KIT MODEL E(C,T)S00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING (KW) HEATING CAPACITY (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V 0.0 0 0.0 0.0 3.2 3.5 15.0 15.0 E(C,T)S03 2.6 3 7.8 10.2 17.3 19.1 20.0 20.0 E(C,T)S05 18,000 3.8 5 13.0 17.1 26.3 29.5 30.0 30.0 E(C,T)S08 6.0 8 20.8 27.3 40.2 45.2 45.0 50.0 E(C,T)S10 7.5 10 25.9 34.1 49.2 55.6 55.0 60 E(C,T)S00 0.0 0 0.0 0.0 3.2 3.5 15.0 15.0 E(C,T)S03 2.6 3 7.8 10.2 17.3 19.1 20.0 20.0 E(C,T)S05 24,000 3.8 5 13.0 17.1 26.3 29.5 25.0 30.0 E(C,T)S08 6.0 8 20.8 27.3 40.2 45.2 40.0 50.0 E(C,T)S10 7.5 10 25.9 34.1 49.2 55.6 55.0 60 E(C,T)S00 0.0 0 0.0 0.0 4.6 5.1 15.0 15.0 E(C,T)S03 2.6 3 7.8 10.2 18.9 20.8 20.0 20.0 E(C,T)S05 3.8 5 13.0 17.1 28.0 31.2 25.0 30.0 30,000 E(C,T)S08 6.0 8 20.8 27.3 41.8 46.8 40.0 50.0 E(C,T)S10 7.5 10 24.9 32.8 49.0 55.1 55.0 60 E(C,T)S15 11.3 15 38.6 51.2 48/23 56/27 50/25 55/30 E(C,T)S00 0.0 0 0.0 0.0 4.6 5.1 15.0 15.0 E(C,T)S03 2.6 3 7.8 10.2 18.9 20.8 20.0 20.0 E(C,T)S05 3.8 5 13.0 17.1 28.0 31.2 40.0 40.0 36,000 E(C,T)S08 6.0 8 20.8 27.3 41.8 46.8 50.0 60.0 E(C,T)S10 7.5 10 24.9 32.8 49.0 55.1 55.0 60 E(C,T)S15 11.3 15 38.6 51.2 48/23 56/27 50/25 55/30 E(C,T)L00 0.0 0 0.0 0.0 8.6 9.5 15.0 15.0 E(C,T)L05 3.8 5 13.0 17.1 32.3 35.5 40.0 50.0 E(C,T)L10 7.5 10 24.9 32.8 53.4 59.5 40/25 40/30 E(C,T)L15 42,000 11.3 15 38.6 51.2 50/25 60/30 50/25 60/30 E(C,T)L20 15.0 20 51.2 68.3 50/50 60/60 50/50 60/60 E(C,T)L25 18.8 25 64.2 85.3 50/50/25 60/60/30 50/50/25 60/60/30 E(C,T)L30 22.5 30 76.8 102.4 50/50/50 60/60/60 50/50/50 60/60/60 E(C,T)L00 0.0 0 0.0 0.0 8.6 9.5 15.0 15.0 E(C,T)L05 3.8 5 13.0 17.1 32.3 35.5 40.0 50.0 E(C,T)L10 7.5 10 24.9 32.8 53.4 59.5 40/25 40/30 E(C,T)L15 48,000 11.3 15 38.6 51.2 50/25 60/30 50/25 60/30 E(C,T)L20 15.0 20 51.2 68.3 50/50 60/60 50/50 60/60 E(C,T)L25 18.8 25 64.2 85.3 50/50/25 60/60/30 50/50/25 60/60/30 E(C,T)L30 22.5 30 76.8 102.4 50/50/50 60/60/60 50/50/50 60/60/60 E(C,T)L00 0.0 0 0.0 0.0 15 15 15 15 E(C,T)L05 3.8 5 13.0 17.0 30 35 30 35 E(C,T)L10 7.5 10 25.6 34.1 50 60 50 60 E(C,T)L15 60,000 11.3 15 38.5 51.2 50/25 60/30 80 90 E(C,T)L20 15.0 20 51.2 68.2 50/50 60/60 100 110 E(C,T)L25 18.8 25 64.0 85.3 50/50/25 60/60/30 120 150 E(C,T)L30 22.5 30 76.8 102.4 50/50/50 60/60/60 140 170 MULTI-POSITION GEM 2 13

MULTI-POSITION GEM MODEL GEM 18/19/24/25 GEM 30/31/36/37 GEM 42/43/48/49/60/61 *Wet coil BLOWER DATA SPEED CFM V. EXTERNAL STATIC* TAP HP AMPS VOLTAGE 0.10 0.20 0.30 0.40 0.50 0.60 0.70 TAP 5 932 894 862 827 800 762 TAP 4 750 706 674 627 600 561 TAP 3 1/3 2.8 600 565 539 502 480 449 TAP 2 932 894 862 827 800 762 TAP 1 750 706 674 627 600 561 TAP 5 1291 1280 1252 1227 1200 1171 TAP 4 1122 1091 1066 1034 1000 982 TAP 3 1/2 4.1 240 898 873 853 827 800 786 TAP 2 745 698 668 630 600 558 TAP 1 1291 1280 1252 1227 1200 1171 TAP 5 2018 1987 1961 1922 1889 1856 1823 TAP 4 1738 1696 1667 1636 1598 1566 1527 TAP 3 1 7.6 1546 1521 1482 1439 1396 1360 1321 TAP 2 1367 1342 1303 1260 1217 1181 1142 TAP 1 2018 1987 1961 1922 1889 1856 1823 AIR HANDLER CHASSIS NOMENCLATURE GEM 18 F -001 GEM = 240V Constant Torque ECM Multi-Position Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code ELECTRIC HEAT KIT NOMENCLATURE E C S 03 Electric Heat Interruption C = Circuit Breaker T = Terminal Block P = Circuit Breaker w/single Point 3 = 3-Phase Circuit Breaker 4 = 3-Phase Terminal Block S = 18-37 L = 42-61 Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 12 = 12 KW 15 = 15 KW 20 = 20 KW 24 24 KW 25 = 25 KW 30 = 30 KW 3 14

DIMENSIONS AND SPECIFICATIONS (In. [mm]) MODEL A B C D E F G GEM18,19+E* GEM24,25+E* GEM30,31+E* GEM36,37+E* GEM42,43+E* GEM48,49+E* GEM60,61+E* 21 [53] 40 [102] 21 [53] 40 [102] 21 [53] 49 1/4 [125] 21 [53] 49 1/4 [125] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 10-1/2 [27] 10-1/2 [27] 10-1/2 [27] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 16X20 0.055 99 4 16X20 0.059 100 4 16X20 0.068 118 4 16X20 0.074 147 4 20X20 0.080 153 4 20X20 0.084 180 4 20X20 0.092 200 4 MULTI-POSITION GEM 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 15

MULTI-POSITION GFM GFM SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY MULTI-POSITION HYDRONIC HEAT DX COIL AIR HANDLERS Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/17 2017 AirMark STANDARD FEATURES APPLICATION VERSATILITY Upflow or horizontal right as shipped (field-convertible for down-flow or horizontal left applications). Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. CABINET Sturdy, galvanized steel cabinet with painted front panels. Cabinet fully insulated with 1/2 faced insulation to prevent sweating and mold growth, to encapsulate glass fibers, and to provide excellent R-value. Stick pins ensure insulation remains in place. Units ship with disposable filter in filter rack. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row. Heat kits are easily installed in the field using Molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. 1 BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently and allow for precise air volume selection. Motor speeds and torques programmed in the motor. Blowers mounted on rails so they can be easily removed for service. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquidline Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Rugged, UV safe, GLP drain pan holds minimal condensate while eliminating the possibility of corrosion. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 16

Model HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA Nominal Cooling GFM18/19 18,000 GFM24/25 24,000 GFM30/31 30,000 GFM36/37 36,000 GFM42/43 42,000 GFM48/49 48,000 GFM60/61 60,000 Model Nominal Cooling GFM18/19 18,000 GFM24/25 24,000 GFM30/31 30,000 GFM36/37 36,000 GFM42/43 42,000 GFM48/49 48,000 GFM60/61 60,000 Hydronic Heat Kit Model Rows PERFORMANCE DATA Coil P.D. (FT.WTR.) Heating Capacity BTU/HR Standard pump at 3.5 GPM Nominal Airflow Entering Water Temp 120 140 160 180 W*2SP 2 5.6 17770 24900 32250 39600 W*3SP 3 4.2 21600 30500 39450 48400 W*2SP 2 5.6 20200 28500 36950 45400 W*3SP 3 4.2 25000 35300 45800 56300 W*2SP 2 5.6 22100 31300 40645 49990 W*3SP 3 4.2 27700 39100 50750 62400 W*4SP 4 2.2 31000 43900 57000 70100 W*2SP 2 5.6 23700 33500 43550 53600 W*3SP 3 4.2 29800 42100 54700 67300 W*4SP 4 2.2 33500 47400 61600 75800 W*2SP 2 5.6 30200 42600 55300 68000 W*3SP 3 4.2 36300 51400 65000 78600 W*4SP 4 2.2 43600 61600 77250 92900 W*2SP 2 5.6 31700 44800 58100 71400 W*3SP 3 4.2 38200 54000 67300 80600 W*4SP 4 2.2 45900 64900 81450 98000 W*2SP 2 5.6 32900 46600 60500 74400 W*3SP 3 4.2 39700 56200 70100 84000 W*4SP 4 2.2 47800 67600 84900 102200 PERFORMANCE DATA Hydronic Heat Kit Model Rows Coil P.D. (FT.WTR.) Heating Capacity BTU/HR High Pressure Drop pump at 5 GPM Nominal Airflow Entering Water Temp 120 140 160 180 W*2S8 2 5.6 18700 26400 34150 41900 W*3S8 3 4.2 22900 32300 41750 51200 W*2S8 2 5.6 22600 31600 40550 49500 W*3S8 3 4.2 26900 38000 49150 60300 W*2S8 2 5.6 23900 33800 43800 53800 W*3S8 3 4.2 30100 42500 55100 67700 W*4S8 4 2.2 34000 48000 62300 76600 W*2S8 2 5.6 25800 36500 47350 58200 W*3S8 3 4.2 32800 46300 60000 73700 W*4S8 4 2.2 37200 52600 68200 83800 W*2S8 2 5.6 33200 46800 60650 74500 W*3S8 3 4.2 40500 57300 70850 84400 W*4S8 4 2.2 49000 69300 86450 103600 W*2S8 2 5.6 34900 49300 63900 78500 W*3S8 3 4.2 42750 60450 74825 89200 W*4S8 4 2.2 52000 73500 91725 109950 W*2S8 2 5.6 36600 51800 67150 82500 W*3S8 3 4.2 45000 63600 78800 94000 W*4S8 4 2.2 55000 77700 97000 116300 ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 6.6 15 6.6 15 9.1 20 9.1 20 14.3 30 14.3 30 14.3 30 ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 6.6 15 6.6 15 9.1 20 9.1 20 14.3 30 14.3 30 14.3 30 MULTI-POSITION GFM 2 17

MULTI-POSITION GFM *Dry coil MODEL GFM 18/19/24/25 GFM 30/31/36/37 GFM 42/43/48/60/61 SPEED TAP TAP 5 HP AMPS BLOWER DATA VOLTAGE CFM V. EXTERNAL STATIC* 0.10 0.20 0.30 0.40 0.50 900 853 797 738 673 TAP 4 670 646 613 592 553 TAP 3 1/3 4.8 500 476 452 421 400 TAP 2 900 853 797 738 673 TAP 1 400 381 360 339 312 TAP 5 1150 1087 1030 975 910 TAP 4 1080 1048 1010 960 895 TAP 3 1/2 6.8 120 900 862 825 796 745 TAP 2 700 663 632 600 552 TAP 1 500 473 449 421 395 TAP 5 1850 1806 1752 1700 1652 TAP 4 1704 1656 1600 1532 1479 TAP 3 1 10.9 1494 1461 1426 1400 1364 TAP 2 1350 1310 1272 1229 1175 TAP 1 676 652 621 600 559 AIR HANDLER CHASSIS NOMENCLATURE GFM 18 G -001 GFM = 120V Constant Torque ECM Multi-Position Air Handler Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE W C 2 S P Water heat (hydronic) Interruption C = Circuit Breaker T = Terminal Block Row 2 3 4 S = GFM18-37 L = GFM42-61 L = Less Pump and Check Valve P = with Standard Pump and Check Valve R = with 009 High Pressure Drop Pump 8 = with 008 High Pressure Drop Pump 3 18

DIMENSIONS AND SPECIFICATIONS (In. [mm]) MODEL A B C D E F G GFM18/19+W* GFM24/25+W* GFM30/31+W* GFM36/37+W* GFM42/43+W* GFM48/49+W* GFM60/61+W* 21 [53] 21 [53] 21 [53] 21 [53] 24-1/2 [62] 24-1/2 [62] 24-1/2 [62] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 49 1/4 [125] 57 [145] 57 [145] 57 [145] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 22-1/4 [57] 22-1/4 [57] 22-1/4 [57] 12 [30] 12 [30] 12 [30] 12 [30] 14-3/4 [37] 14-3/4 [37] 14-3/4 [37] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 18-1/2 [47] 22 [56] 22 [56] 22 [56] 7-1/4 [18] 8-1/4 [21] 8-1/4 [21] 10-1/4 [26] 11 [28] 13 [33] 15 [38] 10-1/4 [26] 12-1/4 [31] 14-1/4 [36] 16-1/4 [41] 16 [41] 18 [46] 20 [51] FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 16X20 0.055 99 4 16X20 0.059 100 4 16X20 0.068 118 4 16X20 0.074 147 4 20X20 0.080 153 4 20X20 0.084 180 4 20X20 0.092 200 4 WALL MOUNT GFM 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 19

GAW GAW SERIES VERTICAL WALL MOUNT ELECTRIC HEAT DX COIL AIR HANDLERS WALL MOUNT WARRANTY One year limited parts warranty OPTIONS See options menu Product Dimensions & Specifications MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air position. Offset hanging brackets attach to unit and wall to allow hanging inside closet. For use with either R22 or R410A when proper metering device is used. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 0, 3, 5, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device factory installed. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. Rev. Date: 08/11/17 2017 AirMark 1 20

MODEL GAW18 GAW23 GAW24 GAW30 GAW36 HEAT KIT HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING CAPACITY HEATING (KW) (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V F(C,T)S00 0.00 0.00 0.00 0.00 2.30 2.30 15 15 F(C,T)S03 2.25 3.00 7.80 10.20 15.80 17.90 20 20 F(C,T)S05 18,000 3.80 5.00 13.00 17.10 24.80 28.30 25 30 F(C,T)S08 6.00 8.00 20.4 27.30 38.30 43.90 40 45 F(C,T)S10 7.50 10.00 25.5 34.10 47.30 54.30 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 2.30 2.30 15 15 F(C,T)S03 2.25 3.00 7.80 10.20 15.80 17.90 20 20 F(C,T)S05 23,000 3.80 5.00 13.00 17.10 24.80 28.30 25 30 F(C,T)S08 6.00 8.00 20.4 27.30 38.30 43.90 40 45 F(C,T)S10 7.50 10.00 25.5 34.10 47.30 54.30 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 2.30 2.30 15 15 F(C,T)S03 2.25 3.00 7.80 10.20 15.80 17.90 20 20 F(C,T)S05 24,000 3.80 5.00 13.00 17.10 24.80 28.30 25 30 F(C,T)S08 6.00 8.00 20.4 27.30 38.30 43.90 40 45 F(C,T)S10 7.50 10.00 25.5 34.10 47.30 54.30 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 3.30 3.30 15 15 F(C,T)S03 2.25 3.00 7.80 10.20 16.80 18.90 20 20 F(C,T)S05 30,000 3.80 5.00 13.00 17.10 25.80 29.30 30 30 F(C,T)S08 6.00 8.00 20.4 27.30 39.30 44.90 40 45 F(C,T)S10 7.50 10.00 25.5 34.10 48.30 55.30 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 3.30 3.30 15 15 F(C,T)S03 2.25 3.00 7.80 10.20 16.80 18.90 20 20 F(C,T)S05 36,000 3.80 5.00 13.00 17.10 25.80 29.30 30 30 F(C,T)S08 6.00 8.00 20.4 27.30 39.30 44.90 40 45 F(C,T)S10 7.50 10.00 25.5 34.10 48.30 55.30 50 60 WALL MOUNT GAW BLOWER DATA MODEL HP AMPS VOLTAGE GAW18/23/24 1/5 1.8 240 GAW30/36 1/3 2.6 240 * Wet coil with filter, - For 208 V multiply by 0.90 CFM V. EXTERNAL STATIC* SPEED 0.10 0.20 0.30 0.40 0.50 LOW 834 795 746 687 620 HIGH 930 888 823 749 680 LOW 1123 1094 1062 1034 1000 HIGH 1396 1358 1313 1261 1200 AIR HANDLER CHASSIS NOMENCLATURE GAW 18 F -001 GAW = 240V PSC Motor Vertical Wall Mount Nominal tonnage (MBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 21

WALL MOUNT GAW ELECTRIC HEAT KIT NOMENCLATURE F C S 05 Wall Mount Electric Heat Interruption C = Circuit Breaker T = Terminal Block S = 18-36 DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F GAW18* GAW23* GAW24* GAW30* GAW36* 37-1/2 [95] 37-1/2 [95] 37-1/2 [95] 40-1/2 [103] 40-1/2 [103] 22 [56] 22 [56] 22 [56] 22 [56] 22 [56] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 14 [36] 14 [36] 14 [36] 14 [36] 14 [36] 10 [25] 10 [25] 10 [25] 11-1/2 [29] 11-1/2 [29] FILTER SIZE PISTON SIZE Heat strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 08 = 8 KW 10 = 10KW SHIP WEIGHT (LBS) SKID QTY 3-1/4 [8.3] 20X20 0.055 90 4 3-1/4 [8.3] 20X20 0.059 90 4 3-1/4 [8.3] 20X20 0.059 90 4 1-3/8 [3.5] 20X20 0.068 102 4 1-3/8 [3.5] 20X20 0.074 102 4 Fig 1 INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR 0 0 3 22

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GAW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-7(S/L) GAW 18/24 Embossed 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-8(S/L) GAW 30/36 Embossed 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 WAD-18(S/L) GAW 18/24 Smooth 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-19(S/L) GAW 30/36 Smooth 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 23

WALL MOUNT GBW GBW SERIES WARRANTY One year limited parts warranty OPTIONS WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications See options menu MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 05/11/17 2017 AirMark STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU s of heat. Heat kits are easily installed in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. 1 Fan time delay relay standard for increased efficiency. Heat kits are available with or without bronze circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquidline Schrader allows pre-installation pressure testing. Available with either factory installed check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 24

UNIT MODEL GBW 18 GBW 24 GBW 30 GBW 36 MODEL HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HYDRONIC HEAT KIT MODEL HP NOMINAL COOLING (BTUS) AMPS GBW18 & GBW 24 1/5 2.8 GBW30 & GBW36 1/3 5.4 PERFORMANCE DATA HEATING COIL BLOWER DATA VOLTAGE 120 Hydronic Coil Delta P. SPEED Heating Capacity(BTU) @ 3.5 GPM ENTERING WATER TEMP ROW Ft.Water 120º 140º 180º U(C,T)2S(P,L) 2 3 18,800 26,600 42,300 18,000 U(C,T)3S(P,L) 3 1.8 21,600 30,400 48,500 U(C,T)2S(P,L) 2 3 21,000 30,100 48,000 24,000 U(C,T)3S(P,L) 3 1.8 24,700 34,800 55,600 U(C,T)2S(P,L) 2 3 23,200 32,800 52,500 U(C,T)3S(P,L) 30,000 3 1.8 27,000 38,200 61,100 U(C,T)4S(P,L) 4 1.1 28,300 40,100 64,000 U(C,T)2S(P,L) 2 3 24,700 35,000 56,000 U(C,T)3S(P,L) 36,000 3 1.8 29,900 41,000 65,500 U(C,T)4S(P,L) 4 1.1 30,400 43,000 68,800 ELECTRICAL DATA MINIMUM MAX CIRCUIT BREAKER OR AMPACITY FUSE SIZE (MCA) 4.1 15 4.1 15 7.4 15 7.4 15 CFM V. EXTERNAL STATIC* 0.10 0.20 0.30 0.40 0.50 LOW 772 736 690 633 574 HIGH 829 784 732 663 600 LOW 1000 980 920 870 800 HIGH 1210 1190 1160 1130 1070 WALL MOUNT GBW * Dry coil AIR HANDLER CHASSIS NOMENCLATURE GBW 18 F -001 GBW = 120V PSC Motor Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE U C 2 S P Wall Mount Hydronic Heat Interruption C = Circuit Breaker T = Terminal Block # of rows 2 = 2 rows 3 = 3 rows 4 = 4 rows S = 18-36 P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less pump 2 25

DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) WALL MOUNT MODEL A B C D E GBW18* GBW24* GBW30* GBW36* Fig 1 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) 22 (56) 22 (56) 22 (56) 22 (56) 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 17-5/8 (45) 17-5/8 (45) 17-5/8 (45) 17-5/8 (45) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) FILTER SIZE PISTON SIZE SHIP WEIGHT (LBS) SKID QTY 20X20 0.055 110 4 20X20 0.059 110 4 20X20 0.068 118 4 20X20 0.074 118 4 INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR 0 0 3 26

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-9(S/L) GBW Embossed 22 1/4 46 24 1/4 48 24 1/8 47 7/8 1 WAD-10(S/L) GBW Embossed 22 1/4 52 24 1/4 54 24 1/8 53 7/8 1 WAD-16(S/L) GBW Smooth 22 1/4 52 24 1/4 54 24 1/8 53 7/8 1 WAD-17(S/L) GBW Smooth 22 1/4 46 24 1/4 48 24 1/8 47 7/8 1 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 27

WALL MOUNT GEW GEW SERIES WARRANTY One year limited parts warranty OPTIONS HIGH EFFICIENCY VERTICAL WALL MOUNT ELECTRIC HEAT DX COIL AIR HANDLERS Product Dimensions & Specifications See options menu MANUFACTURED IN THE USA STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air position. Offset hanging brackets attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 06/30/17 2017 AirMark Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. MODULAR ELECTRIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 3, 5, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Modules are easily installed in the field using molex plugs or can be ordered factory-installed. Controls are accessible from the front for easy service. Electrical connections can be 1 ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either check style flowrater or TXV metering device factory installed. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 28

MODEL GEW18 GEW23 GEW24 GEW30 GEW36 HEAT KIT HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING CAPACITY HEATING (KW) (MBTUH) MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V F(C,T)S00 0.00 0.00 0.00 0.00 3.50 3.50 15 15 F(C,T)S03 2.30 3.00 7.80 10.20 17.00 19.10 20 20 F(C,T)S05 18,000 3.80 5.00 13.00 17.10 26.00 29.50 30 30 F(C,T)S08 6.00 8.00 20.4 27.30 39.60 45.20 40 50 F(C,T)S10 7.50 10.00 25.5 34.1 48.60 55.60 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 3.50 3.50 15 15 F(C,T)S03 2.30 3.00 7.80 10.20 17.00 19.10 20 20 F(C,T)S05 23,000 3.80 5.00 13.00 17.10 26.00 29.50 30 30 F(C,T)S08 6.00 8.00 20.4 27.30 39.60 45.20 40 50 F(C,T)S10 7.50 10.00 25.5 34.1 48.60 55.60 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 3.50 3.50 15 15 F(C,T)S03 2.30 3.00 7.80 10.20 17.00 19.10 20 20 F(C,T)S05 24,000 3.80 5.00 13.00 17.10 26.00 29.50 30 30 F(C,T)S08 6.00 8.00 20.4 27.30 39.60 45.20 40 50 F(C,T)S10 7.50 10.00 25.5 34.1 48.60 55.60 50 60 F(C,T)S00 0.00 0.00 0.00 0.00 5.10 5.10 15 15 F(C,T)S03 2.30 3.00 7.80 10.20 18.70 20.80 25 25 F(C,T)S05 30,000 3.80 5.00 13.00 17.10 27.70 31.20 30 35 F(C,T)S08 6.00 8.00 20.4 27.30 41.20 46.80 45 50 F(C,T)S10 7.50 10.00 25.5 34.1 50.20 57.20 60 60 F(C,T)S00 0.00 0.00 0.00 0.00 5.10 5.10 15 15 F(C,T)S03 2.30 3.00 7.80 10.20 18.70 20.80 25 25 F(C,T)S05 36,000 3.80 5.00 13.00 17.10 27.70 31.20 30 35 F(C,T)S08 6.00 8.00 20.4 27.30 41.20 46.80 45 50 F(C,T)S10 7.50 10.00 25.5 34.1 50.20 57.20 60 60 WALL MOUNT GEW BLOWER DATA MODEL HP AMPS GEW 18/23/24 1/3 2.8 GEW 30/36 1/2 4.1 * Wet coil with filter For 208 operation multiply by 0.90 VOLTAGE 240 SPEED TAP CFM V. EXTERNAL STATIC* 0.10 0.20 0.30 0.40 0.50 TAP 5 909 864 840 800 782 TAP 4 723 690 652 631 600 TAP 3 600 565 539 502 480 TAP 2 723 690 652 631 600 TAP 1 909 864 840 800 782 TAP 5 1365 1332 1303 1271 1240 TAP 4 1174 1132 1106 1078 1047 TAP 3 898 873 853 827 800 TAP 2 745 698 668 630 600 TAP 1 1365 1332 1303 1271 1240 AIR HANDLER CHASSIS NOMENCLATURE GEW 18 F -001 GEW = 240V Constant Torque ECM Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 29

WALL MOUNT GEW ELECTRIC HEAT KIT NOMENCLATURE F C S 03 Wall Mount Electric Heat Interruption C = Circuit Breaker T = Terminal Block S = 18-36 DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) MODEL A B C D E F GEW18* GEW23* GEW24* GEW30* GEW36* 37-1/2 [95] 37-1/2 [95] 37-1/2 [95] 40-1/2 [103] 40-1/2 [103] 22 [56] 22 [56] 22 [56] 22 [56] 22 [56] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 18-3/4 [48] 14 [36] 14 [36] 14 [36] 14 [36] 14 [36] 10 [25] 10 [25] 10 [25] 11-1/2 [29] 11-1/2 [29] FILTER SIZE PISTON SIZE Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 08 = 8 KW 10 = 10 KW SHIP WEIGHT (LBS) SKID QTY 3-1/4 [8.3] 20X20 0.055 90 4 3-1/4 [8.3] 20X20 0.059 90 4 3-1/4 [8.3] 20X20 0.059 90 4 1-3/8 [3.5] 20X20 0.068 102 4 1-3/ [3.5] 20X20 0.074 102 4 Fig 1 INSTALLATION CLEARANCES OPERATION SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR 0 0 3 30

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GEW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-7(S/L) GEW 18/24 Embossed 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-8(S/L) GEW 30/36 Embossed 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 WAD-18(S/L) GEW 18/24 Smooth 22 1/4 39 1/2 24 1/4 41 1/2 24 1/8 41 3/8 1 WAD-19(S/L) GEW 30/36 Smooth 22 1/4 42 1/2 24 1/4 44 1/2 24 1/8 44 3/8 1 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 31

WALL MOUNT GFW GFW SERIES WARRANTY One year limited parts warranty OPTIONS See options menu HIGH EFFICIENCY WALL MOUNT HYDRONIC HEAT DX COOL AIR HANDLERS Product Dimensions & Specifications MANUFACTURED IN THE USA Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 05/11/17 2017 AirMark STANDARD FEATURES APPLICATION VERSATILITY Front or bottom return air. Offset hanging brackets included standard attach to unit and wall to allow hanging inside closet. Can be DOE matched with most brands of air conditioners or heat pumps. ETL listed for use with either R22 or R410A when a proper metering device is used. Constant torque ECM speeds and torques are controlled by software embedded in the motor to maintain constant torque. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Aspen installation instructions. Sturdy, fully insulated galvanized steel cabinet. MODULAR HYDRONIC HEAT KITS Heat kits available with either circuit breakers or terminal blocks. Available in 2, 3 & 4 row, providing 16,000 to 59,000 BTU s of heat. Heat kits are easily installed in the field using molex plugs or can be ordered factory-installed. Freeze stat is standard, wired into circulating pump control circuit. Controls are accessible from the front for easy service. Electrical connections can be made from the top or left. Disconnect does not protrude through the wall panel. Fan time delay relay standard for increased efficiency. Heat kits are available with or without circulating pump and check valve. Units are provided with auxiliary relay for remote pump. Schrader ports are 1 standard on water-out manifold, hose bib available as an option. Totally lead free constructed coil. Suitable for potable applications. BLOWER Direct drive multi-speed blowers circulate air quietly and efficiently. Motor speeds can be easily selected via motor terminals. Swing mounted blowers can be easily removed for service. ELECTRONIC CONTROL BOARD An electronic board controls the functioning of the system reducing moving parts. The board provides for various hot water supply source connections and the blower time delay to maximize heat/cool extraction. As an enhanced feature the pump circulates hot water every 6 hours to prevent coil freeze during off cycle. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with factory installed check style flowrater or TXV metering device. Field-installable TXVs are also available. Galvanized metal drain pan with bottom primary and secondary drain connections or alternate right side primary. All connections 3/4 FPT. Access door allows for coil cleaning. 32

MODEL GFW18 GFW24 GFW30 GFW36 MODEL GFW18 & GFW 24 GFW30 & GFW36 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HYDRONIC HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING COIL HEATING CAPACITY [BTU] @ 3.5 GPM ENTERING WATER TEMP ROWS SIZE 120 O 140 O 180 O U(C,T)2S(P,L) 2 18,800 26,600 42,300 18,000 U(C,T)3S(P,L) 3 21,600 30,400 48,500 U(C,T)2S(P,L) 2 21,000 30,100 48,000 24,000 U(C,T)3S(P,L 3 24,700 34,800 55,600 U(C,T)2S(P,L) 2 23,200 32,800 52,500 18 x10-1/2 U(C,T)3S(P,L) 30,000 3 27,000 38,200 61,100 U(C,T)4S(P,L) 4 28,300 40,100 64,000 U(C,T)2S(P,L) 2 24,700 35,000 56,000 U(C,T)3S(P,L) 36,000 3 29,900 41,000 65,500 U(C,T)4S(P,L) 4 30,400 43,000 68,800 BLOWER DATA ELECTRICAL DATA MINIMUM CIRCUIT AMPACITY (MCA) MAX BREAKER OR FUSE SIZE 6.6 15 6.6 15 9.1 20 9.1 20 SPEED CFM V. EXTERNAL STATIC* TAP HP AMPS VOLTAGE 0.10 0.20 0.30 0.40 0.50 TAP 5 900 851 800 742 682 TAP 4 652 630 591 556 530 TAP 3 1/3 4.8 500 476 452 421 400 TAP 2 400 381 360 339 312 TAP 1 900 851 800 742 682 120 TAP 5 1150 1087 1030 975 910 TAP 4 1080 1048 1010 960 895 TAP 3 1/2 6.8 900 862 825 796 745 TAP 2 700 663 632 600 552 TAP 1 500 473 449 421 395 WALL MOUNT GFW *Dry coil with filter AIR HANDLER CHASSIS NOMENCLATURE GFW 18 G -001 GFW = 115V Constant Torque ECM Vertical Wall Mount Nominal tonnage (MBTUH) Metering device 4 = R410A non-bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE U C 2 S P Wall Mount Hydronic Heat Interruption C = Circuit Breaker T = Terminal Block # of rows 2 = 2 rows 3 = 3 rows 4 = 4 rows S = 18-36 P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = less pump 2 33

WALL MOUNT GFW MODEL GFW18* GFW24* GFW30* GFW36* Fig 1 HEIGHT A 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) 44-1/2 (113) DIMENSIONS AND SPECIFICATIONS (In. [mm]) (Fig 1) WIDTH B 22 (56) 22 (56) 22 (56) 22 (56) DEPTH C 18 3/4 (48) 18 3/4 (48) 18 3/4 (48) 18 3/4 (48) D 17 5/8 (45) 17 5/8 (45) 17 5/8 (45) 17 5/8 (45) E 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) 10-1/2 (27) FILTER SIZE PISTON SIZE INSTALLATION CLEARANCES OPERATION SHIP WEIGHT (LBS) SERVICE TOP 0 0 FRONT 0 30 SIDES 0 0 REAR 0 0 SKID QTY 20X20 0.055 110 4 20X20 0.059 110 4 20X20 0.068 118 4 20X20 0.074 118 4 3 34

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with powder paint and smooth finish. Can be latex painted in the field. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. Fig 2 WALL MOUNT GFW PANEL MODEL ACCESS PANEL DIMENSIONS AND SPECIFICATIONS (Fig 2) FOR USE WITH FINISH OPENING SIZE PANEL DIMENSION FRAME DIMENSION # OF PANELS A B C D E F WAD-9(S/L) GFW Embossed 22 1/4 46 24 1/4 48 24 1/8 47 7/8 1 WAD-10(S/L) GFW Embossed 22 1/4 52 24 1/4 54 24 1/8 53 7/8 1 WAD-16(S/L) GFW Smooth 22 1/4 52 24 1/4 54 24 1/8 53 7/8 1 WAD-17(S/L) GFW Smooth 22 1/4 46 24 1/4 48 24 1/8 47 7/8 1 4 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 35

CEILING MOUNT GAS GAS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Direct drive multi-speed blowers circulate air quietly and efficiently. Two speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on plate so they can be easily removed for service. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Primary & secondary condensate drain. All drain connections are 3/4 MPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 11/03/17 2017 AirMark 1 36

MODEL GAS 18/19/20 GAS 24/25 GAS 26/28 GAS 30/31/32 GAS 36/37 UNIT MODEL GAS 18/19/24 GAS 20/25 GAS 26 GAS 28 GAS 30 GAS 31 GAS 32 HEAT KIT HTS00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA HIGH 1350 1325 1285 1225 1190 1140 1090 1050 GAS 36/37 LOW 1040 1030 1010 990 960 940 900 850 Note: Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 20.05 static when enclosure and/or ceiling panel are used. MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V 0.0 0.0 0.0 0.0 1.8 1.8 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 15.3 17.4 20.0 20.0 HTS05 18,000 3.7 4.8 12.6 16.4 23.4 26.8 25.0 30.0 HTS06 4.6 6.0 15.7 20.5 28.8 33.0 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 37.8 43.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 45.0 51.8 45.0 60.0 HTS00 0.0 0.0 0.0 0.0 1.8 1.8 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 15.3 17.4 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 23.4 26.8 25.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 28.8 33.0 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 37.8 43.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 45.0 51.8 45.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 30,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 36,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 SPEED TAP HIGH HP BLOWER DATA CFM VS. STATIC PRESSURE 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 880 800 770 740 705 670 640 610 LOW 732 711 690 645 620 600 570 543 HIGH 990 960 910 870 815 760 730 690 LOW 820 790 765 732 690 650 610 595 1/4 HIGH 1040 1008 956 914 856 798 767 725 LOW 861 830 803 769 725 683 640 625 HIGH 1040 1008 956 914 856 798 767 725 LOW 861 830 803 769 725 683 641 625 HIGH 1085 1045 1000 950 900 850 800 740 LOW 965 925 880 850 800 750 700 650 HIGH 1230 1150 1110 1070 1020 980 940 890 LOW 1057 1010 980 940 910 870 830 775 1/3 HIGH 1350 1325 1285 1225 1190 1140 1090 1050 LOW 1040 1030 1010 990 960 940 900 850 CEILING MOUNT GAS 37

CEILING MOUNT GAS AIR HANDLER CHASSIS NOMENCLATURE G A S 18 G -001 Voltage Configuration Option Code A = 240V PSC Motor S = Uncased Ceiling Mount AirMark Air Handler ENCLOSURES DIMENSIONS Nominal Tonnage (KBTUH) ELECTRIC HEAT KIT NOMENCLATURE UNIT MODEL A B C Weight (lbs) Skid Qty. GAS 18/19/24 37 1/4 34-5/8 30 125 8 GAS 20/25/30 43 1/4 40-5/8 36 135 8 GAS 26/31/36 49 1/4 46 5/8 42 145 8 GAS 28/32/37 56 1/4 53 5/8 48 155 8 Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 3 38

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GAS 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GAS 20/25/30 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GAS 26/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GAS 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GAS 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 4 39

CEILING MOUNT GAT GAT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Direct drive multi-speed blowers circulate air quietly and efficiently. Two speed motors allow for precise air volume selection. Motor speeds can be easily selected via motor terminals. Blowers mounted on plate so they can be easily removed for service. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Airmark installation instructions. Sturdy, fully insulated galvanized steel cabinet with knockout for duct return. DX COIL High efficiency rifled copper tubes/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs are also available. Primary & secondary condensate drain. All drain connections are 3/4 NPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 11/03/17 2017 AirMark 1 40

MODEL GAT 18/19/20 GAT 24/25 GAT 26/28 GAT 30/31/32 GAT 36/37 UNIT MODEL GAT 18/19/24 GAT 20/25 GAT 26 GAT 28 GAT 30 GAT 31 GAT 32 HEAT KIT HTS00 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA HIGH 1350 1325 1285 1225 1190 1140 1090 1050 GAT 36/37 LOW 1040 1030 1010 990 960 940 900 850 Note: Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 20.05 static when enclosure and/or ceilling panel are used. MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V 0.0 0.0 0.0 0.0 1.8 1.8 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 15.3 17.4 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 23.4 26.8 25.0 30.0 18,000 HTS06 4.6 6.0 15.7 20.5 28.8 33.0 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 37.8 43.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 45.0 51.8 45.0 60.0 HTS00 0.0 0.0 0.0 0.0 1.8 1.8 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 15.3 17.4 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 23.4 26.8 25.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 28.8 33.0 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 37.8 43.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 45.0 51.8 45.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 30,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 2.7 2.7 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 16.2 18.3 20.0 20.0 HTS05 3.7 4.8 12.6 16.4 24.3 27.7 25.0 30.0 36,000 HTS06 4.6 6.0 15.7 20.5 29.7 33.9 30.0 35.0 HTS08 6.1 8.0 20.8 27.3 38.8 44.4 40.0 45.0 HTS10 7.4 9.6 25.3 32.8 46.0 52.7 50.0 60.0 SPEED TAP HIGH HP BLOWER DATA CFM VS. STATIC PRESSURE 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 880 800 770 740 705 670 640 610 LOW 732 711 690 645 620 600 570 543 HIGH 990 960 910 870 815 760 730 690 LOW 820 790 765 732 690 650 610 595 1/4 HIGH 1040 1008 956 914 856 798 767 725 LOW 861 830 803 769 725 683 640 625 HIGH 1040 1008 956 914 856 798 767 725 LOW 861 830 803 769 725 683 641 625 HIGH 1085 1045 1000 950 900 850 800 740 LOW 965 925 880 850 800 750 700 650 HIGH 1230 1150 1110 1070 1020 980 940 890 LOW 1057 1010 980 940 910 870 830 775 1/3 HIGH 1350 1325 1285 1225 1190 1140 1090 1050 LOW 1040 1030 1010 990 960 940 900 850 CEILING MOUNT GAT 41

CEILING MOUNT GAT AirMark Air Handler AIR HANDLER CHASSIS NOMENCLATURE G A T 18 G -001 Voltage Configuration Nominal Option Code A = 240V PSC Motor T = Cased Ceiling Mount Tonnage B = 120V PSC Motor (KBTUH) ELECTRIC HEAT KIT NOMENCLATURE Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW ENCLOSURES DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GAT 18/19/24 40 30 30 125 5 GAT 20/25/30 46 36 36 135 5 GAT 26/31/36 52 42 42 145 5 GAT 28/32/37 60 48 48 155 5 3 42

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAT ACCESS DOOR AND FRAME A B C D GAT 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GAT 20/25/30 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GAT 26/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GAT 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GAT CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-1 GAT18/19/24 40"X24"X11" CAP-2 GAT20/25/30 46"X24"X11" CAP-3 GAT 26/31/36 52"X24"X11" CAP-4 GAT 28/32/37 60"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 4 43

CEILING MOUNT GBS GBS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT HYDRONIC HEAT DX COIL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/26/17 2017 AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Direct drive blowers circulate air quietly and efficiently. Multiple speeds allow for precise air volume selection. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 44

MODEL GBS 18 GBS 19/24 GBS 25 GBS 30 GBS 31/36 HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA PERFORMANCE DATA MODEL NOMINAL PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING COOLING DROP GPM (BTUS) (FT. WTR) 120 140 180 1 0.7 10.3 14.4 22.6 GBS 18 18,000 2 2.0 12.0 16.8 26.4 3 3.3 12.9 18.0 28.3 2 2.1 14.7 20.6 32.4 GBS 19/24 24,000 3 4.1 15.9 22.2 34.9 4 6.6 16.5 23.1 36.3 2 2.2 15.7 22.0 34.6 GBS 25 24,000 3 4.3 17.0 23.8 37.4 4 6.8 17.6 24.7 38.8 2 2.2 17.3 24.2 38.0 GBS 30 30,000 3 4.3 18.8 26.3 41.3 4 6.8 19.6 27.5 43.2 2 2.8 19.7 27.6 43.4 GBS 31/36 36,000 3 5.4 21.7 30.4 47.8 4 8.5 22.8 31.9 50.1 NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA SPEED CFM VS. STATIC PRESSURE AMP VOLT HP TAP 0.1 0.2 0.3 0.4 0.5 HIGH 820 750 685 615 540 2.5 1/4 LOW 715 670 610 555 460 HIGH 890 825 755 675 605 2.5 1/4 LOW 765 715 665 605 520 HIGH 975 900 830 745 680 3.8 120 1/3 LOW 900 840 770 690 620 HIGH 1055 965 865 755 605 2.3 1/5 (2) LOW 1015 915 815 705 565 HIGH 1235 1150 1040 925 830 2.3 1/5 (2) LOW 1050 980 900 800 680 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GBS 30, GBS31 and GBS 36 have two motors and four blowers. CEILING MOUNT GBS AIR HANDLER CHASSIS NOMENCLATURE G B S 18 G -001 AirMark Air Handler Voltage B = 120V PSC Motor Configuration S = Uncased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil GBS 18 - X GBS 19/24 - S GBS - 25/30 - M GBS 31/36 - L P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump 2 45

CEILING MOUNT GBS PHYSICAL DIMENSIONS UNIT MODEL A B C D Weight (lbs) Skid Qty. GBS 18 42 37 30 37 82 8 GBS 19-24 48 43 36 43 93 8 GBS 25 55 50 42 50 101 8 GBS 30 55 50 42 50 121 8 GBS 31-36 62 56 48 56 127 8 (GBS 18-25) Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL (GBS 30-36) GAS ACCESS DOOR AND FRAME A B C D GBS 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GBS 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GBS 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 FILTER 20 x 20 x 1 field supplied. GBS 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 WARRANTY One-year limited parts warranty. 3 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 46

GBT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT HYDRONIC HEAT DX COIL AIR HANDLER Product Dimensions & Specifications CEILING MOUNT GBT Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/17 2017 AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Fully insulated galvanized steel cabinet with knockout for ducted return. Direct drive blowers circulate air quietly and efficiently. Multiple speeds allow for precise air volume selection. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 47

CEILING MOUNT GBT MODEL HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA NOMINAL COOLING (BTUS) GBT 18 18,000 GBT 19/24 24,000 GBT 25 24,000 GBT 30 30,000 GBT 31/36 36,000 PERFORMANCE DATA PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING DROP GPM (FT. WTR) 120 140 180 1 0.7 10.3 14.4 22.6 2 2.0 12.0 16.8 26.4 3 3.3 12.9 18.0 28.3 2 2.1 14.7 20.6 32.4 3 4.1 15.9 22.2 34.9 4 6.6 16.5 23.1 36.3 2 2.2 15.7 22.0 34.6 3 4.3 17.0 23.8 37.4 4 6.8 17.6 24.7 38.8 2 2.2 17.3 24.2 38.0 3 4.3 18.8 26.3 41.3 4 6.8 19.6 27.5 43.2 2 2.8 19.7 27.6 43.4 3 5.4 21.7 30.4 47.8 4 8.5 22.8 31.9 50.1 NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP 0.1 0.2 0.3 0.4 0.5 GBT 18 HIGH 820 750 685 615 540 2.5 1/4 LOW 715 670 610 555 460 GBT 19/24 HIGH 890 825 755 675 605 2.5 1/4 LOW 765 715 665 605 520 GBT 25 HIGH 975 900 830 745 680 3.8 120 1/3 LOW 900 840 770 690 620 GBT 30 HIGH 1055 965 865 755 605 2.3 1/5 (2) LOW 1015 915 815 705 565 GBT 31/36 HIGH 1235 1150 1040 925 830 2.3 1/5 (2) LOW 1050 980 900 800 680 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GBT 30, GBT 31 and GBT 36 have two motors and four blowers. AIR HANDLER CHASSIS NOMENCLATURE G B T 18 G -001 AirMark Air Handler Voltage B = 120V PSC Motor Configuration T = Cased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil GBT 18 - X GBT 19/24 - S GBT - 25/30 - M GBT 31/36 - L P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump 2 48

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. ENCLOSURE DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GBT 18 46 30 34 110 5 GBT 19-24 52 36 40 125 5 GBT 25 60 42 47 135 5 GBT 30 60 42 47 155 4 GBT 31-36 67 48 55 165 4 ACCESS DOOR DIMENSIONS GAS ACCESS DOOR AND FRAME FOR USE WITH PANEL MODEL A B C D GBT 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GBT 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GBT 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GBT 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 CEILING MOUNT GBT FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-5 GBT18 46 X24 X11 CAP-6 GBT19/24 52"X24"X11" CAP-7 GBT25/30 60"X24"X11" CAP-8 GBT31/36 67"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration 3 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 49

CEILING MOUNT GES GES SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY ECM UNCASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. STANDARD FEATURES APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Constant torque ECM allows motor speed control with embedded software. Motors are pre-programmed at the factory. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8 & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Heat elements are replaceable without removing blowers. Easily accessible controls for quick service. Disconnect does not protrude through the wall panel. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. DX COIL High efficiency rifled copper tube/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs is also available. Primary & secondary condensate drain. All drain connections are ¾ MPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. Rev. Date: 03/28/17 2017 AirMark 1 50

MODEL GES 18/19/20 GES 24/25/26/27/28 GES 30/31/32 GES 36/37 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 18,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 30,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 36,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 CEILING MOUNT GES AIR HANDLER CHASSIS NOMENCLATURE G E S 18 G -001 Voltage & Motor Configuration Option Code E = 240V Constant Torque ECM S = Uncased Ceiling Mount AirMark Air Handler Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV ELECTRIC HEAT KIT NOMENCLATURE H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 2 51

CEILING MOUNT GES UNIT MODEL GES 18/19 GES 20/24 GES 25 GES 26/30 GES 28 GES 31/36 GES 32 GES 37 SPEED TAP AMPS HIGH 0.9 HP BLOWER DATA CFM VS. STATIC PRESSURE 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 732 711 690 645 620 600 570 543 MEDIUM 0.8 630 610 590 564 531 502 480 460 LOW 0.7 590 560 530 500 485 460 440 420 HIGH 0.9 732 711 690 645 620 600 570 543 MEDIUM 0.8 630 610 590 564 531 502 480 460 LOW 0.7 590 560 530 500 485 460 440 420 HIGH 1.4 960 934 920 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 HIGH 1.4 950 930 910 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 1/2 HIGH 1.4 960 934 920 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 HIGH 2.0 1240 1200 1180 1160 1150 1080 1040 1030 MEDIUM 1.9 1100 1085 1070 1040 1030 1010 1000 980 LOW 1.6 950 940 930 920 900 865 850 845 HIGH 1.9 1100 1085 1070 1040 1030 1010 1000 980 MEDIUM 1.7 1070 1042 1030 1010 1000 980 970 920 LOW 1.5 950 940 930 920 900 865 850 845 HIGH 2.1 1240 1200 1180 1160 1150 1080 1040 1030 MEDIUM 1.9 1100 1085 1070 1040 1030 1010 1000 980 LOW 1.7 1070 1042 1030 1010 1000 980 970 920 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceilling panel are used. CHASSIS DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GES 18/19/24 37 1/4 34-5/8 30 135 8 GES 20/25 43 1/4 40-5/8 36 145 5 GES 26/30/31/36 49 1/4 46 5/8 42 155 4 GES 28/32/37 56 1/4 53 5/8 48 175 5 3 52

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. FOR USE WITH ACCESS DOOR DIMENSIONS PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GES 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GES 20/25 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GES 26/30/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GES 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CEILING MOUNT GES 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 4 53

CEILING MOUNT GET GET SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA HIGH EFFICIENCY ECM CASED CEILING MOUNT ELECTRIC HEAT DX COOL AIR HANDLER Product Dimensions & Specifications STANDARD FEATURES Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. APPLICATION VERSATILITY Built in mounting tabs for ceiling or furrdown mounting. Louvered ceiling access panel has separate frame that attaches to ceiling joists. Solid access panel available for use with end return installations. Compatible with most brands of air conditioners or heat pumps. Constant torque ECM allows motor speed control with embedded software. Motors are pre-programmed at the factory. LOW LEAKAGE CABINET Less than 2% air leakage from cabinet when tested in accordance with ASHRAE standard 193. Unit must be installed according to Airmark installation instructions. Sturdy, fully insulated galvanized steel cabinet with knockout for duct return. ELECTRIC HEAT KITS Heat kits available in 3, 5, 6, 8, & 10 KW. Models with electric heat include sequencers and temperature limit switches for safe, efficient operation. Easily accessible controls for quick service. DX COIL High efficiency rifled copper tube/enhanced aluminum fins provide maximum heat transfer. All coils immersion tested at 500 psi then nitrogen pressurized and factory sealed for maximum reliability. Liquid-line Schrader allows pre-installation pressure testing. Available with either orifice or TXV metering device factory installed. Field-installable bolt-on TXVs is also available. Primary & secondary condensate drain. All drain connections are ¾ NPT. Powder-painted metal drain pan. Access door allows for coil cleaning. Certified for use with either R22 or R410A. ELECTRONIC CIRCUIT BOARD Electronic circuit board provides 30 secs ON/OFF blower time delay extracting more heat/cool from the coil. Rev. Date: 08/11/17 2017 AirMark 1 54

MODEL GET 18/19/20 GET 24/25/26/27/28 GET 30/31/32 GET 36/37 HEATING AND COOLING PERFORMANCE AND ELECTRICAL DATA HEAT KIT NOMINAL COOLING (BTUS) PERFORMANCE DATA HEATING KW HEATING KBTUH MINIMUM CIRCUIT AMPACITY (MCA) ELECTRICAL DATA MAX BREAKER OR FUSE SIZE 208V 240V 208V 240V 208V 240V 208V 240V HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 18,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 24,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 30,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 HTS00 0.0 0.0 0.0 0.0 5.0 5.0 15.0 15.0 HTS03 2.3 3.0 7.8 10.2 18.5 20.6 20.0 25.0 HTS05 3.7 4.8 12.6 16.4 26.6 30.0 30.0 30.0 36,000 HTS06 4.6 6.0 15.7 20.5 32.0 36.3 35.0 40.0 HTS08 6.1 8.0 20.8 27.3 41.1 46.7 45.0 50.0 HTS10 7.4 9.6 25.3 32.8 48.3 55.0 50.0 60.0 CEILING MOUNT GET AIR HANDLER CHASSIS NOMENCLATURE G E T 18 G -001 Voltage & Motor Configuration Option Code E = 240V Constant Torque ECM S = Uncased Ceiling Mount AirMark Air Handler Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV ELECTRIC HEAT KIT NOMENCLATURE H T S 10 H = Fits GAS, GAT, GES, GET T = Terminal Block S = Small Cabinet (18-37) Heat Strip 00 = NO Heat 03 = 3 KW 05 = 5 KW 06 = 6 KW 08 = 8 KW 10 = 10 KW 2 55

CEILING MOUNT GET UNIT MODEL GET 18/19 GET 20/24 GET 25 GET 26/30 GET 28 GET 31/36 GET 32 GET 37 BLOWER DATA SPEED CFM VS. STATIC PRESSURE TAP AMPS HP 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 HIGH 0.9 732 711 690 645 620 600 570 543 MEDIUM 0.8 630 610 590 564 531 502 480 460 LOW 0.7 590 560 530 500 485 460 440 420 HIGH 0.9 732 711 690 645 620 600 570 543 MEDIUM 0.8 630 610 590 564 531 502 480 460 LOW 0.7 590 560 530 500 485 460 440 420 HIGH 1.4 960 934 920 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 HIGH 1.4 950 930 910 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 1/2 HIGH 1.4 960 934 920 900 880 865 850 810 MEDIUM 1.0 850 835 825 815 810 770 730 710 LOW 0.9 785 775 750 732 710 690 670 645 HIGH 2.0 1240 1200 1180 1160 1150 1080 1040 1030 MEDIUM 1.9 1100 1085 1070 1040 1030 1010 1000 980 LOW 1.6 950 940 930 920 900 865 850 845 HIGH 1.9 1100 1085 1070 1040 1030 1010 1000 980 MEDIUM 1.7 1070 1042 1030 1010 1000 980 970 920 LOW 1.5 950 940 930 920 900 865 850 845 HIGH 2.1 1240 1200 1180 1160 1150 1080 1040 1030 MEDIUM 1.9 1100 1085 1070 1040 1030 1010 1000 980 LOW 1.7 1070 1042 1030 1010 1000 980 970 920 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. ENCLOSURES DIMENSIONS UNIT MODEL A B C Weight (lbs) Skid Qty. GET 18/19/24 40 30 30 135 5 GET 20/25 46 36 36 145 5 GET 26/30/31/36 52 42 42 155 5 GET 28/32/37 60 48 48 175 5 KNOCKOUT FOR DUCTED RETURN (Ducted return requires remote filter grille (field supplied) and non-louvered panel) 3 56

Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. ACCESS DOOR DIMENSIONS AND SPECIFICATIONS FOR USE WITH PANEL MODEL GAS ACCESS DOOR AND FRAME A B C D GET 18/19/24 GAD-1(S/L) 43-1/2 27-1/2 41-1/2 26 GET 20/25 GAD-5(S/L) 49-1/2 27-1/2 47-1/2 26 GET 26/30/31/36 GAD-2(S/L) 55-1/2 27-1/2 53-1/2 26 GET 28/32/37 GAD-6(S/L) 63-1/2 27-1/2 61-1/2 26 CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-1 GET18/19/24 40"X24"X11" CAP-2 GET20/25 46"X24"X11" CAP-3 GET 26/30/31/36 52"X24"X11" CAP-4 GET 28/32/37 60"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration CEILING MOUNT GET 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 4 57

CEILING MOUNT GFS GFS SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA UNCASED CEILING MOUNT HYDRONIC HEAT HIGH EFFICIENCY ECM DX COIL AIR HANDLER Product Dimensions & Specifications Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/26/17 2017 AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Constant torque ECM speeds and torques are controlled by embedded motor software and factory preprogrammed. Direct drive blowers circulate air quietly and efficiently. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 58

MODEL HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA NOMINAL COOLING (BTUS) GFS 18 18,000 GFS 19/24 24,000 GFS 25 24,000 GFS 30 30,000 GFS 31/36 36,000 BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP 0.1 0.2 0.3 0.4 0.5 HIGH 770 730 700 670 640 GFS18 MED 7.0 120 1/2 715 680 640 610 580 LOW 585 540 490 465 415 HIGH 950 915 875 830 800 GFS19/24 MED 7.0 120 1/2 820 780 745 710 670 LOW 700 675 630 590 545 HIGH 1005 965 920 850 780 GFS25 MED 7.0 120 1/2 845 795 755 720 680 LOW 765 710 665 635 600 HIGH 1180 1155 1100 1040 980 GFS30 MED 7.0 120 1/2 1085 1040 995 965 920 LOW 1030 965 935 885 845 HIGH 1455 1375 1285 1195 1105 GFS31/36 MED 7.0 120 1/2(2) 1300 1245 1185 1150 1075 LOW 1085 1030 975 915 860 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GFS 31 and GFS 36 have two motors and four blowers. PERFORMANCE DATA PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING DROP GPM (FT. WTR) 120 140 180 1 0.7 10.3 14.4 22.6 2 2.0 12.0 16.8 26.4 3 3.3 12.9 18.0 28.3 2 2.1 14.7 20.6 32.4 3 4.1 15.9 22.2 34.9 4 6.6 16.5 23.1 36.3 2 2.2 15.7 22.0 34.6 3 4.3 17.0 23.8 37.4 4 6.8 17.6 24.7 38.8 2 2.2 17.3 24.2 38.0 3 4.3 18.8 26.3 41.3 4 6.8 19.6 27.5 43.2 2 2.8 19.7 27.6 43.4 3 5.4 21.7 30.4 47.8 4 8.5 22.8 31.9 50.1 NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. CEILING MOUNT GFS AIR HANDLER CHASSIS NOMENCLATURE G F S 18 G -001 AirMark Air Handler F=120V Constant Torque ECM Motor Configuration S= Uncased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 59

CEILING MOUNT GFS HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil PHYSICAL DIMENSIONS GFS 18 - X GFS 19/24 - S GFS - 25/30 - M GFS 31/36 - L UNIT MODEL A B C D Weight (lbs) Skid Qty. GFS 18 42 37 30 37 86 8 GFS 19-24 48 43 36 43 97 8 GFS 25 55 50 42 50 105 8 GFS 30 55 50 42 50 125 8 GFS 31-36 62 56 48 56 135 8 P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. MATERIALS Galvanized steel construction with smooth powder paint finish. FILTER 20 x 20 x 1 field supplied. (GFS 18-30) (GFS 31-36) ACCESS DOOR DIMENSIONS GAS ACCESS DOOR AND FRAME FOR USE WITH PANEL MODEL A B C D GFS 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GFS 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 GFS 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GFS 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 WARRANTY One-year limited parts warranty. 3 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 60

GFT SERIES WARRANTY One year limited parts warranty OPTIONS See options menu MANUFACTURED IN THE USA CASED CEILING MOUNT HYDRONIC HEAT HIGH EFFICIENCY ECM DX COIL AIR HANDLER Product Dimensions & Specifications CEILING MOUNT GFT Representative image only. Some models may vary in appearance. Due to continuous product improvement, specifications are subject to change without notice. Rev. Date: 10/27/17 2017 AirMark STANDARD FEATURES Factory installed service switch Factory installed freeze protection Rifled copper tube/enhanced aluminum fins DX and hydronic coils for more efficient heat transfer Schrader valve on DX and hydronic coils for hisstest leak check Low leak cabinet design* APPLICATION VERSATILITY Built-in mounting tabs for ceiling or furdown mounting. Compatible with most brands of air conditioners and heat pumps. Optional louvered ceiling access panel has separate frame that attached to ceiling joists. Optional solid ceiling panel available for use with ducted return. Less than 2% air leakage (* when tested in accordance with ASHRAE standard 193 and AirMark installation instructions.) Fully insulated galvanized steel cabinet with knockout for ducted return. Constant torque ECM speeds and torques are controlled by embedded motor software and factory preprogrammed. Direct drive blowers circulate air quietly and efficiently. Air moving system is plated mounted to allow for easy removal and service. 1 ELECTRONIC CONTROLS Electronic board controls the functioning of system, increasing system reliability. Standard factory installed freeze stat wired into circulating pump control circuit. Standard factory installed fan time delay relay for increased efficiency and maximize capacity. Standard factory installed pump cycle timer circulates hot water every four hours to prevent coil freeze during off-cycle. DX/HYDRONIC COILS High efficiency rifled copper tube and enhanced aluminum fins provide maximum heat transfer. All coils are immersion tested at 500 PSI and nitrogen charged for maximum reliability. Schrader valve allows for hiss-test pre-installation pressure test. Available with factory installed orifice or TXV. Primary and secondary DX condensate drain with ¾ NPT connections. Powder-painted galvanized drain pan. Certified for use with R22 or R410A. Lead free construction. 61

CEILING MOUNT GFT HEATING AND COOLING PERFORMANCE & ELECTRICAL DATA PERFORMANCE DATA MODEL NOMINAL PRESS. BTU (1000) AT ENTERING WATER TEMPERATURE F HEATING COOLING DROP GPM (BTUS) (FT. WTR) 120 140 180 1 0.7 10.3 14.4 22.6 GFT 18 18,000 2 2.0 12.0 16.8 26.4 3 3.3 12.9 18.0 28.3 2 2.1 14.7 20.6 32.4 GFT 19/24 24,000 3 4.1 15.9 22.2 34.9 4 6.6 16.5 23.1 36.3 2 2.2 15.7 22.0 34.6 GFT 25 24,000 3 4.3 17.0 23.8 37.4 4 6.8 17.6 24.7 38.8 2 2.2 17.3 24.2 38.0 GFT 30 30,000 3 4.3 18.8 26.3 41.3 4 6.8 19.6 27.5 43.2 2 2.8 19.7 27.6 43.4 GFT 31/36 36,000 3 5.4 21.7 30.4 47.8 4 8.5 22.8 31.9 50.1 NOTES: Heat BTUH is at 70 degree EAT. 120 degree and 180 degree data is supplied for boiler applications. Heat BTUH output will not exceed output of water heater. BLOWER DATA CFM VS. STATIC PRESSURE UNIT MODEL RPM AMP VOLT HP 0.1 0.2 0.3 0.4 0.5 HIGH 770 730 700 670 640 GFT18 MED 7.0 120 1/2 715 680 640 610 580 LOW 585 540 490 465 415 HIGH 950 915 875 830 800 GFT19/24 MED 7.0 120 1/2 820 780 745 710 670 LOW 700 675 630 590 545 HIGH 1005 965 920 850 780 GFT25 MED 7.0 120 1/2 845 795 755 720 680 LOW 765 710 665 635 600 HIGH 1180 1155 1100 1040 980 GFT30 MED 7.0 120 1/2 1085 1040 995 965 920 LOW 1030 965 935 885 845 HIGH 1455 1375 1285 1195 1105 GFT31/36 MED 7.0 120 1/2(2) 1300 1245 1185 1150 1075 LOW 1085 1030 975 915 860 Units should not be applied to a system with less than 350 CFM/Ton airflow. Add 0.05 static when enclosure and/or ceiling panel are used. GFT 31 and GFT 36 have two motors and four blowers. AIR HANDLER CHASSIS NOMENCLATURE G F T 18 G -001 AirMark Air Handler F=120V Constant Torque ECM Motor Configuration T = Cased Ceiling Mount Nominal Tonnage (KBTUH) Metering Device 4 = R410A non-bleed A/C or H/P TXV 6 = R410A 20% bleed A/C or H/P TXV B = R22 20% bleed A/C or H/P TXV F = R22 Flo-rater G = R410A Flo-rater X = R22 non-bleed A/C or H/P TXV Option Code 2 62

Airflow Access Door VERSATILITY Equipped with hidden frame feature. Fastens to the outside wall surface and does not have to perfectly match the hole opening. Frame screws are not visible after installation. Available in either solid (S) or louvered (L) style. HYDRONIC HEAT KIT NOMENCLATURE Z T 2 S P Water Heat Hydronic Terminal Block 2 = 2 Row Hydronic Coil FOR USE WITH GFT 18 - X GFT 19/24 - S GFT - 25/30 - M GFT 31/36 - L ENCLOSURE DIMENSIONS ACCESS DOOR DIMENSIONS PANEL MODEL P = Taco 006 Bronze Pump 8 = Taco 008 Bronze Pump L = Less Pump UNIT MODEL A B C Weight (lbs) Skid Qty. GFT 18 46 30 34 115 5 GFT 19-24 52 36 40 130 5 GFT 25-30 60 42 47 140 5 GFT 31-36 67 48 55 170 4 GAS ACCESS DOOR AND FRAME A B C D GFT 18 GAD-5(S/L) 49 1/2 27 1/2 47 1/2 26 GFT 19/24 GAD-3(S/L) 55 1/2 27 1/2 53 1/2 26 CEILING MOUNT GFT MATERIALS Galvanized steel construction with smooth powder paint finish. GFT 25/30 GAD-6(S/L) 63-1/2 27 1/2 61-1/2 26 GFT 31/36 GAD-4(S/L) 70-1/2 27 1/2 68-1/2 26 FILTER 20 x 20 x 1 field supplied. WARRANTY One-year limited parts warranty. CAP KIT PART NUMBER Part Number Model Number Enclosure Size CAP-5 GFT18 46 X24 X11 CAP-6 GFT19/24 52"X24"X11" CAP-7 GFT25/30 60"X24"X11" CAP-8 GFT31/36 67"X24"X11" Note: CAP kit is an insulated panel that covers the entire bottom opening and is utilized for optional ducted return configuration 3 373 Atascocita Rd Humble, TX 77396 Phone 800.423.9007 Fax 281.441.6510 www.airmark-ac.com 63