Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Similar documents
Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Study of R161 Refrigerant for Residential Airconditioning

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

CHAPTER 1 INTRODUCTION

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

DEEPAK PALIWAL, S.P.S.RAJPUT

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

η second law = Second law efficiency

International Journal of Advance Engineering and Research Development

International Journal of Multidisciplinary Research and Modern Education (IJMRME) ISSN (Online): (

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

ADVANCES in NATURAL and APPLIED SCIENCES

Department of MCE, Islamic University of Technology 2. Abstract

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Evaluation for Replacement of R22 as R161 in the Vapour Compression Cycle through Aspen Plus Software

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

JJMIE Jordan Journal of Mechanical and Industrial Engineering

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Experimental investigation on the performance of air conditioner using R32 Refrigerant

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

A Comparison Between Refrigerants Used In Air Conditioning

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

STUDY AND PERFORMANCE ANALYSIS OF ECO-FRIENDLY REFRIGERANT FOR RETROFITTING R22 IN RESPECT TO BANGLADESH

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

PERFORMANCE EVALUATION OF ALTERNATIVE REFRIGERANTS

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Evaluation of HCFC Alternative Refrigerants

Experimental study of R600a and R436a to replace R134a in a domestic refrigerator and freezer

Performance Assessment of Three Eco-Friendly Hydro-Fluorocarbon and Hydrocarbon Refrigerant Mixtures as R22 Alternatives in Refrigeration Systems

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

CHAPTER 1 INTRODUCTION

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Performance Evaluation of Vapour Compression System with R22 and Environment-Friendly Refrigerant

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

Review of Current Automobile Refrigeration System on Basis of Refrigerants Used & Their Impact on Global Warming Potential.

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Energy Performance Assessment of R32/R125/R600a Mixtures as Possible Alternatives to R22 in Compression Refrigeration Systems

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Performance improvement of vapour compression refrigeration systems

Chapter 2. Alternatives to HCFCs and their Characteristics

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

ADVANCES in NATURAL and APPLIED SCIENCES

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

ENERGY PERFORMANCE ASSESSMENT OF R134A/LPG BLEND AS REPLACEMENT OF R134A IN VAPOR COMPRESSION REFRIGERATION SYSTEM

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Keywords: Climate change; ozone depletion; Montreal protocol; eco-friendly refrigerant; hydrocarbon refrigerant; performance analysis.

Transcription:

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator Mr. Subodh S. Deshpande Department of Mechanical Engineering M.G.M.s College of Engineering Nanded-431606, India Asst. Prof. D. N. Hatkar Department of Mechanical Engineering M.G.M.s College of Engineering Nanded-431606, India Abstract In this paper, a detailed study of hydrocarbon refrigerants R134a and R161 is performed. The mixture after the theoretical study at specified temperature range in a domestic refrigerator is proposed as an alternative refrigerant to R134a. Study is performed by considering domestic refrigerator and its working conditions. The temperature range was set between -5⁰C and 50⁰C with 5⁰C sub cooling and 10⁰C compressor inlet superheating. The composition was selected such that the performance should not vary but the global warming potential must be lowered. The main objective of this study is to replace the existing refrigerant without modification in the existing design. So, this study compares the performance, economical and environmental aspects of existing R134a and mixture of R134a/R161. Keywords COP, Refrigerant, GWP, ODP, Montreal protocol and Kyoto ptrotocol. I. INTRODUCTION As we see the brief history of refrigerants, no refrigerant has made its firm position in the industry of refrigerant. The history starts with ether and now hydrocarbons are used. The major concern about the hydrocarbons is their flammability, global warming potential and ozone depletion potential. According to Montreal and Kyoto protocol the use of halons, chloroflourocarbons was banned serially.(john T. McMullan). And now the objective is to phase out the HCFCs also. So in order to achieve this objective there is a need of finding out the alternatives. R134a is a good alternative for the existing refrigerants as it is having 0 ODP. But the GWP value is very high (Wongwise et. al). So though the refrigerant is performing well with systems running on VCC it is lacking in full filling environmental requirements. In recent years, the study was performed for proposing the alternate refrigerants by using number of refrigerants like R290a, R600a, HFO1234yf, R152a, R161 etc. For example S. J. Sekhar et. al (2005) studied the performance of HFC134a/HC600a/HC290 mixture as a substitution for R12. Sad Jarall (2012) performed experiments by using HFO1234yf as a drop in substitute for existing R134a in a rotary compressor operated refrigeration system. And concluded with the results that states HFO1234yf has lower COP, refrigeration capacity but gives higher evaporation and convection heat transfer coefficients than R134a. A. S. Dalkilic et. al. (2010) compared the performances of various alternative refrigerants in a vapour compression refrigeration system. Results showed that HC290/HC600a (40/60 by wt.%) and HC290/HC1270 (20/80 by wt.%) are found to be the most suitable alternatives among the tested refrigerants for R12 and R22 respectively. Jianyong Chen et. al. (2008) proposed a new refrigeration cycle for residential air conditioning system using R32/R134a mixture. Results showed that (30/70 by wt.%) combination can be a strong replacement for R22. M. Wu et. al. (2014) studied the performance of refrigeration system by directly replacing R134a by R161. Results showed that the COP is more in case of R161 when the evaporator temperature is lower and it come closer to COP of R134a when the evaporation temperature rises. Recently, Prof. Zhao Yang et. al. (2015) experiments on flammability of R161 showed that the flammability range of this refrigerant can be reduced combining it with flame suppression inhibitors like 507

R227ea, R1234ze (E). As flammability of R161 is a major concern in the replacement the last mentioned study contributes much more in this concern. In this paper the mixture of R134a and R161 is studied as a replacement for the R134a in domestic refrigeration system. Its thermodynamic properties and cycle performances are investigated theoretically. II. THEORY A. Introduction to the refrigerant mixture and its composition Before proposing the new binary refrigerant mixture the operating of the domestic refrigerator needs an overlook. A domestic refrigerator generally operates in the moderate working temperature limits. -10⁰C to 5⁰C evaporation temperature and 45⁰C to 60⁰C condenser temperature. The compressor discharge temperature is obviously more than the condenser temperature. Considering capacity of the refrigerator and sealing provided to the cabin moderate cooling rate is required. So, not much change is required in the case of heat dissipation rate and evaporation rate in the case of new refrigerant. The refrigerant should be environment friendly in case it is leaked from the system. The new mixture is selected to full fill the following requirements: 1. Its GWP should be less than that of R134a 2. Specific refrigeration capacity should be more 3. It should be compatible with existing system without any modifications in the system. 4. The use of the new refrigerant should be economical. By considering these requirements as objectives this study was performed. Both refrigerants were first examined at different combinations by weight. REFPROP 9.0 routines were used for calculating the refrigerant properties at these different combinations. A simulation program in NETBEANS by using JAVA was constructed for calculation of the cycle performance at various compositions. The simulations of cycle performances for different refrigerant combinations were performed to find out the optimum combination. While calculating the cycle performances following basic assumptions were considered : 1. there are no pressure losses in the system, 2. there are no leakages in the system, 3. overall efficiency of compressor is predefined i. e. 0.51 (Xiao Hong Han et. al. 2012), 4. lubricating oil used and its oil circulation rate is same for both the refrigerants. All the calculations used to obtain the results were taken from the book (Refrigeration and air conditioning third edition by C. P. Arora). After calculating the performance parameters at various combinations finally at the combination of HFC-134a and HFC-161 (60/40 by wt.%) was considered for further study and it was referred as MR1. The results of performance of different combinations were plotted in table 1 and basic thermo-physical properties were listed in table 2. From table 1, it can be observed that at 60/40 (by weight %) combination of these two gases the COP was similar to that of R134a but the specific refrigeration effect was increased by 37% and volumetric refrigeration capacity by 32.6%. The GWP value if we calculate on weight basis comes down to 785 which is far lower than the existing refrigerants GWP value. Further the COP goes on increasing with increasing percentage of R161. But it will not be feasible to use R161 directly as it is inflammable and its lower flammability limit is 3.92% (Prof. Zhao Yang et. al. 2015). So there is a need of mixing it with some moderate amount of R134a. B. Theoretical cycle performance of MR1 and R134a The condenser and evaporator temperatures were considered to be constant firstly and then they were varied and different temperature combinations and results were studied. Initially the evaporator temperature was assumed to be -5⁰C. And the condenser temperature was assumed to be 50⁰C. subcooling of 5⁰C at condenser exit and superheating of 10⁰C at compressor inlet was considered. In later case evaporator temperatures were varied from -10⁰C to 0⁰C and similarly condenser temperatures from 45⁰C -55⁰C. Each evaporator temperature was matched with every condenser temperature and the results are discussed in the next section. Cycle performances using simulation were checked for both the refrigerants and then compared. III. RESULT AND DISCUSSIONS After simulating the cycle performance at specified temperature of evaporator and condenser the obtained results 508

are plotted in Table 3. From the results it was observed that the COP of the cycle increases with increase in evaporator temperature for same condenser temperature. And COP of MR1 is very close to R134a at different operating conditions. Specific and volumetric refrigeration effect also increases with increase in evaporator temperature. The specific refrigeration effect and volumetric refrigeration effect of MR1 were 37% and 32.6 % respectively more than that of R134a. The discharge temperature slightly decreases with increase in evaporator temperature. And it was more than that of R134a in each case. Pressure ratio also follows the same behavior like discharge temperature and goes on decreasing with increase in evaporator temperature. But it was lower in case of MR1 than R134a. So, all the results and discussions clears the picture that R134a can be replaced directly by MR1 in case of domestic refrigerator. Fig. 1 to Fig. 6 shows the results of comparison between the two refrigerants. Fig. 1 is the comparison of R134a and MR1 on a temperature versus saturation pressure graph. It can be observed that saturation pressure of MR1 at given temperature is more than that of R134a. The pressure of MR1 at lowest temperature is 1.43 times that of R134a and this changes to 1.24 times at highest temperature. Fig. 2 shows the COP variation with evaporator temperature. Results show that COP of both refrigerants do not vary from each other except in one or two cases. Fig. 3 is a comparison of specific refrigeration capacity at different evaporation temperatures. The refrigeration effect is about 1.46 times more than that of R134a. Fig. 4 compares the specific work consumption of compressor for both refrigerants. From fig. 5 it can be observed that the use of MR1 gives higher compressor discharge temperature in each working temperature range. And fig. 6 shows that the pressure ratio of MR1 is slightly lower than that of R134a. A. Abbreviations and Acronyms COP - Coefficient of performance GWP - Global warming potential ODP - Ozone depletion potential Re - Specific refrigeration effect Wc - Compressor work Rev - Volumetric refrigeration effect PR - Pressure ratio mr - mass flow rate of refrigerant Tdis - compressor discharge temperature Pe - evaporator pressure Pc - condenser pressure B. Equations Compressor work (Wc) = h2 - h1 (1) Refrigeration effect (Re) = h1 - h5 (2) COP = Re / Wc (3) Refrigerant mass flow rate (mr) = (TR x 3.51 / Re) (4) Power = mr x Wc (5) Volumetric refrigeration capacity (Rev) = Re / vs (6) Pressure Ratio (PR) = P2 / P1 (7) Figure 1 : Saturation pressure vs saturation temperature Figure 2 : COP vs evaporation temperatures 509

Figure 3 : Refrigeration effect vs evaporation temperature Figure 6 : Pressure ratio vs evaporator temperature Figure 4: Compressor work vs evaporation temperature IV. CONCLUSION In this paper a new substitute in the form of MR1 is proposed for substitution in domestic refrigerator in place of R134a. A mixture of HFC-134a and HFC-161 (60/40 by wt.%) was selected and the theoretical performances were checked by simulation. After studying the results it was observed that MR1 and R134a were having identical COP at each temperature combination. At same COP the specific and volumetric refrigeration effect were 37% and 32.6 % respectively more than that of R134a. Moreover the discharge temperature is more than R134a by 2.01%. Also the pressure ratio the pressure ratio is reduced by 10.2%. As per the environmental performance is concerned there is a considerable drop in GWP value. Thus overall the substitution of MR1 is most preferable as it is system compatible, environmentally sound and also gives superior performance than existing one. This study is purely theoretical and need further practical validation. ACKNOWLEDGMENT I submit my sincere thanks to my guide Asst. Prof. D. N. Hatkar, Prof. M.G. Harkare, Head Mechanical Engineering Department, M.G.M.s College of Engineering, Nanded for their constant support for this researchwork. Figure 5 : Discharge temperature vs evaporator temperature 510

REFERENCES [1] HFC134a/HC600a/HC290 mixture a retrofit for CFC12 systems. S.J. Sekhar, D.M. Lal, International Journal of Refrigeration 28 (2005) 735 743. [2] Study of refrigeration system with HFO-1234yf as a working fluid. Sad Jarall, International jou rnal of refrigeration-2012 [3] Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502. R. Camporese, G. Bigolaro, S. Bobbo, G. Cortella. International Journal of Refrigeration. Vol 20, 1997. [4] Hydrocarbons as refrigerants - an overview. Eric Granryd, International Journal of Refrigeration, 2000. [5] A performance comparison of vapour-compression refrigeration system using various alternative refrigerants. A. S. Dalkilic, S. Wongwises. International Journal of Heat and Mass Transfer. 2010 [6] Research on the Flammable Characteristics of Fluoroethane (R161) and Its Binary Blends. Prof. Zhao Yang, Xi Wu, Xiaoming Wang, Tian Tian, International Journal of Refrigeration 2015. [7] Performance of a new refrigeration cycle using refrigerant mixture R32/R134a for residential air conditioner applications. Jianyong Chen, Jianlin Yu, International Journal of Energy and Buildings. 2008. [8] Performance of mixture refrigerant R152a/R125/R32 in domestic air-conditioner. Jiangtao Wu, Yingjie Chu, Jing Hu, Zhigang Liu. International Journal of Refrigeration,2009. [9] Cycle performance study of ethyl fluoride in the refrigeration system of HFC-134a. M. Wu, X.R.Yuan Y.J. Xu, X.G. Qiao, X.H. Han, G.M. Chen. Applied Energy 2014. [10] Refrigeration and the environment - issues and strategies for the future. John T. McMullan, International Journal of refrigeration, 2002. [11] The next generation of refrigerants Historical review, considerations, and outlook. James M. Calm. International journal of Refrigeration. 2008. 511

TABLE 1 : CYCLE PERFORMANCES OF REFRIGERANT MIXTURE AT DIFFERENT COMPOSITIONS R134a R161 Wc Re COP P Tdis Pe Pc PR Rev 1 0 72.8 132.0 1.81 1.9 337.5 0.24 1.31 5.4 1585.6 0.9 0.1 80.0 142.8 1.78 1.9 339.8 0.27 1.43 5.2 1732.3 0.8 0.2 86.8 154.8 1.78 1.9 341.6 0.29 1.53 5.1 1874.5 0.7 0.3 93.4 167.8 1.79 1.9 343.0 0.31 1.60 5.0 2000.4 0.6 0.4 100.2 181.6 1.81 1.9 344.3 0.33 1.64 4.9 2103.9 0.5 0.5 107.2 195.9 1.82 1.9 345.5 0.34 1.68 4.8 2184.3 0.4 0.6 116.7 208.6 1.78 1.9 350.6 0.35 1.70 4.8 2222.2 0.3 0.7 122.1 225.9 1.85 1.8 347.8 0.36 1.71 4.7 2289.4 0.2 0.8 129.7 241.4 1.88 1.8 348.9 0.36 1.72 4.7 2322.8 0.1 0.9 137.5 257.0 1.86 1.8 350.0 0.36 1.72 4.7 2347.4 0 1 145.4 272.9 1.87 1.8 351.1 0.36 1.72 4.6 2366.1 TABLE 2 : THERMO-PHYSICAL PROPERTIES OF R134a, MR1 and R12 Property (Unit) R12 R161 R134a MR1 Molecular mass 120.93 48.1 102.03 80.45 Normal boiling point -29.8-36.0-26.07-30.04 temperature (⁰C) Critical temperature 112.0 102.2 101.06 101.51 (⁰C) Critical pressure 4.14 4.70 4.06 4.31 (MPa) ODP 0.82 0 0 0 GWP 8100 12 1300 785 512

TABLE 3 : THEORETICAL DATA AT DIFFERENT TEMPERATURES Refrigerant Tc Te COP Re Wc Rev Tdis PR Pe Pc MR1 45-10 1.8 187.7 104.1 1826.8 340.5 5.2 0.19 1.46 50-10 1.59 178.3 112 1735.2 345.8 5.9 0.33 1.64 55-10 1.41 168.7 119.6 1641.9 350.9 6.6 0.39 1.85 45-5 2.07 191 92.4 2212.9 338.9 4.3 0.19 1.46 50-5 1.81 181.6 100.2 2103.9 344.3 4.9 0.33 1.64 55-5 1.59 172 107.8 1992.8 349.5 5.5 0.39 1.85 45 0 2.38 194.2 81.3 2662.5 337.4 3.6 0.19 1.46 50 0 2.07 184.8 89 2533.4 342.9 4.1 0.33 1.64 55 0 1.81 175.2 96.5 2402.0 348.1 4.6 0.39 1.85 R134a 45-10 1.8 136.5 75.6 1362.9 333.3 5.7 0.19 1.15 50-10 1.5 129 81.3 1288.1 338.4 6.5 0.24 1.31 55-10 1.39 121.3 86.7 1211.9 343.4 7.4 0.29 1.48 45-5 2.07 139.2 67.3 1675.6 332.4 4.7 0.19 1.15 50-5 1.81 132.0 72.8 1585.6 337.5 5.4 0.24 1.31 55-5 1.58 124.3 78.2 1493.9 342.6 6.1 0.29 1.48 45 0 2.4 142.4 59.3 2044.6 331.6 3.9 0.19 1.15 50 0 2.07 134.9 64.8 1936.9 336.8 4.5 0.24 1.31 55 0 1.81 127.3 70.2 1827.5 341.9 5.1 0.29 1.48 513