INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation Instructions

INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION MANUAL

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Installation Instructions

INSTALLATION INSTRUCTIONS

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

INSTALLATION INSTRUCTIONS

Installation Instructions

Your safety and the safety of others are very important.

AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS

Installation Instructions

Installation Instructions

Installation Instructions

MERIT Series R-410A - Upflow / Horizontal

INSTALLATION INSTRUCTIONS

MERIT SERIES Up Flow / Horizontal

Installation Instructions

Electric Heat Accessory Installation Instructions

MERIT Series R-410A - Upflow / Horizontal

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

Installation Instructions

Installation Instructions

ACCESSORY KIT INSTALLATION INSTRUCTIONS

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

Installation Instructions

AG Series Electric Heaters

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

Installation Instructions

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Installation Instructions

B SERIES ELECTRIC FURNACE

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

CBX32MV (HFC-410A) SERIES UNITS

INSTALLATION INSTRUCTION

INSTALLATION MANUAL WARNING STANDARD PSC MODULAR MULTI-POSITION AIR HANDLERS MODELS: MP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

Installation Instructions

Installation Instructions

INSTALLATION MANUAL SINGLE PIECE, 4 POSITION AIR HANDLERS MODELS: AHR SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

F, P Series Multi-Position Air Handler Electric or No Heat, with available 5-Speed High Efficiency ECM Motor

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Owners Manual/Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHP SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Installation Instructions

INSTALLATION MANUAL LIST OF SECTIONS. 1 General 1 3 Louvered Door Frame Assembly Installation 3 2 Safety 2 4 Coil Cabinet Installation 5

MODELS B1PA024, 030 AND 036

Installation Instructions

Installation instructions for Plenum-mounted add-on electric heaters

INSTALLATION AND MAINTENANCE INSTRUCTIONS EF Electric Furnace

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Installation & Maintenance Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

INSTALLATION MANUAL SINGLE PIECE NON-VARIABLE SPEED AIR HANDLERS MODELS: AHX SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

Installation Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

USER'S MANUAL/INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Product Data. FH4A Fan Unit. Sizes 001 thru 004

INSTALLATION INSTRUCTIONS APARTMENT FAN COIL UNIT FMA4X, FMA4P

INSTALLATION INSTRUCTIONS

ELECTRIC UNIT HEATER UH SERIES

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Product Data. FH4A Fan Unit. Sizes 001 thru 004

INSTALLATION INSTRUCTIONS

USER'S MANUAL/INSTALLATION INSTRUCTIONS

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

INSTALLATION MANUAL SINGLE PIECE VARIABLE SPEED AIR HANDLERS MODELS: AV*(C) SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL

SM Field Installed Electric Heat Kit

Transcription:

INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED IF THE AIR HANDLER IS INSTALLED IN A UNCONDITIONED SPACE THAT A CIRCUIT BREAKER COVER (ORDERED SEPARATELY) IS USED. ORDER LENNOX CATALOG # 82W01. Table of Contents Electric Heat Sections... 1 Shipping and Packing List... 1 General Information... 1 Heat Section Installation... 2 Changing Circuit Breaker Orientation... 2 Electrical Connections... 4 Blower Speed Connections... 4 Unit Start-Up... 5 Wiring Diagrams... 5 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Electric Heat Sections KNOCKOUTS CIRCUIT BREAKER COVER BLOWER ACCESS PANEL The electric heat sections provide field installed electric heat for coil blower series air handler units. Table 1 shows the available heat sections. Refer to the engineering handbook for specific heat section applications. Table 1 Element Plate Kit Heater Kw Rating Stage Termination Type 0655009-01 5 1 Pig Tail Connector 0655009-02 5 1 Terminal Block 0655009-03 5 1 Circuit Breaker 0655009-04 7.5 1 Circuit Breaker 0655009-05 7.5 1 Terminal Block 0655009-06 10 1 Terminal Block 0655009-07 10 1 Circuit Breaker 0655009-09 15 2 Circuit Breaker 0655009-11 20 2 Circuit Breaker Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life, or damage to property. Installation and service must be performed by a licensed professional installer (or equivalent) or a service agency. CAUTION Physical contact with metal edges and corners while applying excessive force or rapid motion can result in personal injury. Be aware of, and use caution when working near these areas during installation or while servicing this equipment. Shipping and Packing List Package 1 of 1 contains 1 - Assembled electric heat section Check equipment for shipping damage. If you find any damage, immediately contact the last carrier. General Information These instructions are intended to be a general guide and do not supersede any local or national codes. Installation must conform with the local building codes and with the latest editions of the National Electric Code. Page 1 (0655012-30)

Be sure to disconnect all power to the unit while you install and service this equipment. Use proper tools and protective equipment during installation and service. Installation of blower section with or without optional electric heat must conform with standards in the National Fire Protection Association (NFPA) Standard for Installation of Air Conditioning and Ventilation Systems NFPA No. 90A, and Standard for Installation of Resident Type Warm Air Heating and Air Conditioning System, No. 90B, the manufacturer's installation instructions, and local municipal building codes. Heat Section Installation Before installing the unit, check information on the unit rating plate to ensure that the unit meets the job specification, proper electrical power is available, and that proper duct clearances are maintained. OFFSET WIRE HARNESS SEPARATE CONNECTOR; DISCARD WIRE HARNESS NO HEAT SEAL PLATE REMOVE WIRE TIE WRAP AND IT'S FASTENER AND DISCARD REMOVE SCREWS; THEN REMOVE NO-HEAT SEAL PLATE Figure 1. Prepare to Install Heat Element Before installing or servicing unit, be sure ALL power to the unit is OFF. More than one disconnect switch may be present. Electrical shock can cause personal injury or death! NOTE - If installing heat sections at the same time as the air handler unit, install the electric heat section in the air handler unit before setting the air handler unit and attaching the plenum. 1. Shut off all power to the air handler unit. More than one disconnect may be required. 2. Remove blower section access panel and keep the 6 screws to reattach access panel after installing heat elements. 3. Disconnect any existing field supply wires and pull them out of the air handler. Remove the wire tie and its fastener - if not removed, it will prevent the heat element's base from resting properly in the compartment. 4. Remove the no-heat seal plate in the air handler frame. See figure 1. 5. Slide the electric heat section into the blower section. Be careful that the heating elements do not rub against the sheet metal opening when they slide into the blower section. The side opposite the side with the mounting holes should slip behind the offset. The mounting holes should then line up with holes in the air handler control box. 6. Secure the electric heater assembly into place with the screws that were removed from the heat element panel. Install two field-provided #8 SDST screws in the front of the electric heater assembly (see figure 2). Foil face insulation must be cut to eliminate the possibility for any frayed foil to coming in contact with any main or low voltage connections. Insulation must be kept a minimum of 1/2 away from any electrical connection. INSTALL SCREWS REMOVED FROM THE NO-HEAT SEAL PLATE. INSTALL 2 FIELD PROVIDED SCREWS TO SECURE THE FRONT OF THE HEATER ASSEMBLY TO THE AIR HANDLER. Figure 2. Installing the Heat Element Assembly Changing Circuit Breaker Orientation The coil blower comes from the factory setup for horizontal left-hand discharge which will require no change in the circuit breaker orientation. However, if the coil blower is installed in a horizontal right-hand discharge position, the breaker will need to be rotated 180º so that the UP position of the breaker is the ON position. The circuit breaker orientation change is required by UL 1995, Article 26.18 (25 Sep 2005). Page 2 505084M

1 3 1. The factory default configuration for the two circuit breakers is horizontal left-hand discharge which will require no change. To change the two circuit breakers orientation for right-hand discharge, proceed to step 2. 3. Flip the breaker so that the wires attached to the circuit breakers terminals are on the left side. 2 NOTE - There may be only one clip securing each circuit breaker. 4 TAB WHITE MOUNTING CLIP TAB WHITE MOUNTING CLIP 2. Locate the two white clips which are located on the left and right side (see arrows) of each breaker. The four clips secure the two circuit breakers to the mounting bracket. Pull the tabs to release the breakers from the mounting bracket. 4. Use the white clip to reattach the circuit breaker to the mounting bracket. Page 3

5 6 in accordance with tables 310-16 and 310-17 in the National Electric Code, ANSI/NFPA No. 70 or tables 1 through 4 in the Canadian Electric Code, Part I, CSA Standard C22.1. Refer to figure 5 for typical low voltage field wiring for air handler/condensing unit and heat pump applications. Figure 8 is a diagram of the air handler connections and the heater elements high-voltage wiring. 1. Make wiring connections as follows - Heaters equipped with circuit breakers Connect field power supply wiring to circuit breaker(s). Figure 3 shows L1, L2 and ground (GND) connections for a 2-breaker configuration. KNOCKOUTS GND 208/240 VOLT FIELD SUPPLY WIRES L1 CIRCUIT 1 ON 60 OFF BLOWER ACCESS PANEL 5. The air handler access panels have knockouts over the circuit breaker opening. Knock out both plates to accommodate the circuit breaker levers. If installing a heat element assembly with circuit breakers, remove the knockouts but do not install the access panel until all electrical connections have been completed. 6. Electric heaters with circuit breakers: Using a sharp blade, cut the foil back insulation to allow the breaker to fit flat to access panel. Field Supply Ground Wires L2 L1 L2 CIRCUIT 2 Figure 3. Field Power Supply Wiring Heaters equipped with terminal blocks Connect field power supply wiring to terminal block(s).figure 4 shows L1, L2 and ground (GND) connection for a terminal block configuration. ON 60 OFF Electrical Connections Electric shock hazard. Be sure all poser supplies have been disconnected before making electrical connections. Failure to do so can result in death or electrical shock. GND FIELD SUPPLY GROUND WIRES L2 208/240 VOLT FIELD SUPPLY WIRES L1 USE COPPER CONDUCTORS ONLY. NOTE - Refer to the nameplate on the air handler unit for minimum circuit ampacity and maximum overcurrent protection size. The air handler units are provided with openings to be used with 1-1/2 inch trade size (1-31/32 inch diameter) conduit. If you want a single point power supply, refer to the nameplate on the single point power supply accessory for minimum circuit ampacity and maximum overcurrent protection size. Select the proper supply circuit conductors Figure 4. Terminal Block Connections 2. Remove the interface harness from the air handler unit and connect the 6-pin connector on the heater assembly to the mating connector on the air handler unit. 3. For applications using a two stage room thermostat and/or an outdoor thermostat, connect wiring as shown in figure 5. Blower Speed Connections When using the electric heat sections with coil blower series air handler units, you must adjust the blower speed according to the size of electric heat and air handler unit. The minimum blower setting for each blower size with any heat sections in Page 4 505084M

any application is LOW, except for 0655009-11 (20kw) which should be set to a minimum of HIGH speed. See specific air handler installation instructions for blower speed adjustment procedure and location. Unit Start Up 1. After all electrical connections have been completed and jumpers configured (if required), replace the blower compartment access cover. Wiring Diagrams 2. Restore power to the unit. 3. If using an electro-mechanical room thermostat, set the thermostat heat anticipator to 0.4 amps. 4. Set the thermostat above room temperature. 5. Check the heat pump and the heat section for normal operation. 6. Set the thermostat to desired setting. 7. Affix the wiring diagram sticker to blower scroll, aligned with CB unit wiring diagram sticker. R AIR HANDLER R AIR HANDLER HEAT PUMP UNIT G W G BK BU CONNECT COMMON WIRE ONLY IF REQUIRED (REFER TO THE APPROPRIATE INSTALLATION INSTRUCTIONS) S23 OUTDOOR (IF USED) BU BK K22 EM HEAT RELAY W Air Handler CONDENSING UNIT Heat Pump Application With Electric Heat Figure 5. Low Voltage Field Wiring Electric Heat Figure 6. Heat Selector Pin Page 5

Figure 7. Field Wiring Diagram Electric Heat & Hot Water Heat (B Series & MX Series Models Only) 4 8 2 6 RELAY 1 4 8 2 6 RELAY 2 18 WHT TIME DELAY H =1 SECOND TO HEAT UP C =45 SECONDS TO COOL DOWN USE COPPER CONDUCTORS ONLY Figure 8. Field Wiring Diagram - Electric Heat and Air Handler Page 6 505084M