Stacklights E26 Series

Similar documents
Bulletin 855T 70 mm Control Tower Stack Lights

AUTOMAX devices for the automation industry

Attention-grabbing performance from two new stacklights

signaling solutions from auer signal

Series M22 Signaling Beacons and Alarms

Half-Dome. the Design-Tower. Compact

INDICATOR LAMPS & LED REPLACEMENT LAMPS

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

signaling solutions visual signaling signal towers Audible signaling

Pilot devices Stacklights Signal beacons

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

About Tomar Audible Alarms 1000 & 1100 Power Alarm WEP Explosion Proof Power Alarm Siren

INSTRUCTION & SERVICE MANUAL

Auer - Signal tower ECO Ø70 mm modular

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

standards: standards:

New Beacon Series T & U

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Celebrating YEARS Manufacturers of Visual & Audible Signalling Devices. NEW Exd

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

TrueAlert Multi-Candela Notification Appliances

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

High Intensity LED Strobe Light - 10 Watt - 10~30 Volts DC - Permanent Mount - 14 Strobe Patterns

Vibratone Horns. Models 350 and 450

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Applications. Standard Materials

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Smarter Signaling AUDIBLE/VISUAL SIGNALS

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

INSTRUCTION MANUAL (ATEX / IECEx)

E3M-V. Mark Sensor. Applications

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

ISIS SAFETY SYSTEM Installation guide

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Rugged LED shelter lighting

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Plug-in Base, Long Range Sensor E3B2

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

Oxygen (O2) Single-Point Gas Detection System

STROBE POWER SUPPLIES - two outlets by Tomar Electronics

FAQ s- 30mm Stacklights

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

LED Ultrastar. trobe beacons

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

VISUAL AND AUDIBLE SIGNALLING DEVICES

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Warning/Hazard Lighting MASTERY STATEMENT:

5.0. Photoelectric Sensors. Technical Reference. Introduction

WARRANTY FLEXOPTIX HIGH BAY/FLOOD.

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Bulletin 855X Horns, Beacons, and Loudspeakers... Page 11-65

Pictogram Exit Signs Catalogue

The Signal Is Clear TM

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Class 1 laser beam sensor safe for your eyes

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

NATELA 5. Based on 30 PRODUCT SPECIFICATIONS PRODUCT FEATURES PHOTOMETRIC DATA LIGHT DISTANCE CURVE 22W LINEAR WALL WASHER

OPERATING AND INSTALLATION

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Two-Channel Gas Controller

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Accessory Products

Class 1 laser beam sensor safe for your eyes

2 Tones to select LU7

Clear Choice VISUAL SIGNALS. The machines my company builds are recognized around the world as the very best.

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

POINT FLASHING BEACON PFB EX LED HAZARDOUS AREA CLASS I, DIVISION 2

INSTRUCTION & SERVICE MANUAL

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

Hot Products. Heavy Industrial Intercom Sytems. XLT Technology (extreme Light Technology) Federal Signal Introduces Hazardous Location with 27XL 225XL

NEMA-4X Series. Certified for Harsh Environment Applications

LMV Series W Low Profile - Medium Base

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Signaling Solutions for Alarm, Warning, and Indication

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

Obstruction Lighting Guide

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

ecolor Graze Powercore Linear LED surface light for wall washing and grazing

Industrial Signalling

N2MVF Series Compact Fluorescent

Transcription:

Stacklights Three- Stacklight with 60 mm Extension.1 Product Description............................................. 2 Features...................................................... 2 Benefits...................................................... 2 Standards and Certifications....................................... 2 Product Identification............................................ 3 Selection........................................ 4 Product Selection............................................... 5 Replacement Parts.............................................. 10 Technical Data and Specifications.................................. 11 Ratings....................................................... 12 Mounting Instructions........................................... 13 Dimensions.................................................... 14 Control Products Catalog CA08102001E August 2010 www.eaton.com 1

.1 Stacklights Stacklights Contents Description Page Product Identification........................... 3 Selection....................... 4 Product Selection.............................. 5 Replacement Parts............................. 10 Technical Data and Specifications................. 11 Ratings...................................... 12 Mounting Instructions.......................... 13 Dimensions.................................. 14 Product Description The E26 stacklight unit is a modular system that provides illuminated and audible status indication in all directions. Easily assembled plug-in modular units include constant, flashing and strobe light units, as well as monotonal, bi-tonal, intermittent audible alarms. Stacklights may be assembled in a variety of configurations, which are identified in the Maximum Configurations table on Page 3. Several lamp, col and mounting options further enhance the stacklight s versatility. Features Modular construction Six lens cols Variety of lamp types and voltages Mono-tonal, bi-tonal and intermittent audible alarms Benefits Combination of visible and audible alarms Modular components reduce inventy requirements, increase flexibility Steady and flashing modes allow one light to signal multiple conditions No-tools assembly permits easy lamp replacement Standards and Certifications CE 60947-5-1 UL 508 File No. E131568 cul C22.2 No. 14 File No. E131568 Ingress Protection Stacklight base and light units: IP65, NEMA 4, 4X and 13 units: IP20, NEMA 1 Electrical Shock Protection Stacklight base and light unit: IP2X units: IP0X 2 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 Product Identification Standard Stacklight F use with incandescent standard LEDs f steady, non-flashing illumination with flashing LEDs f flashing illumination. s include terminal block f wiring, stacklight cover and gasket. See Page 8. Flashing Stacklight Allows configuration of each light in the stack f either steady 60 times per minute flashing illumination. Flashing circuit f use with incandescent lamps only. (Maximum allowable number of light modules is 2 at 12V, 4 at 24V and 6 at 48V and above.) See Page 8. F flashing LEDs use standard base with flashing LED light module. Xenon Strobe Sets are similar to standard lens/diffuser units, except each set consists of two lens units. The lower unit includes the electronics and is permanently fused to the upper unit which contains the Xenon lamp. Xenon units may be placed in any position in a complete stacklight unit. They will flash 60 times per minute when used with a standard flashing base. See Page 6. s May be fitted to the top of a complete stacklight unit directly to the stacklight bases, if desired. Available in three versions, each with adjustable sound levels. See Page 9. Complete Stacklight Modules Level 3 Level 2 Level 1 Stacklight Extension Tube Mounting Maximum Configurations Incandescent LED Modules Xenon Modules Stacklights accept a maximum of six incandescent LED light modules two Xenon Flasher modules and can be mounted in any position on the stack. units are mounted in the top most position only. Modules 6 6 5 1 6 4 1 5 3 1 1 5 2 2 4 1 2 1 4 Max. Number of Modules Modules Available in a variety of cols f both incandescent lamps and LED lamps. To maximize illumination and light dispersion, incandescent units include an opal white diffuser while LED diffusers are clear. See Page 6. Control Products Catalog CA08102001E August 2010 www.eaton.com 3

.1 Stacklights Selection Stacklight ing System Voltage Codes Voltage Code Incandescent Lamp Cluster LED Cylindrical LED Xenon Flasher Flasher / (Blank) No lamp supplied No LED supplied No LED supplied V1 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc 12 Vac/Vdc V2 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc 24 Vac/Vdc V3 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc 48 Vac/Vdc V4 120 Vac/Vdc 120 Vac 120 Vac 120 Vac 120 Vac/Vdc V5 240 Vac/Vdc 240 Vac 240 Vac 240 Vac/Vdc Notes Unless base mount is specified, an extension tube must be selected f a complete unit. Component catalog numbers f flashing bases, alarm units and light modules are incomplete and require the addition of a suffix code to specify the required voltage rating. See table above. If no voltage is specified, assembled stacklight will be supplied without lamps LEDs. 240V not available f cylindrical LEDs. F complete length (extension tube and base), see Page 9. Code W 4 8 9 Extension Tube Code Description Component Catalog No. W None (base mount) Gray Aluminum HM JM KM MM HU JU KU MU RU Mounting Description None (base mount) 3/4 in NPT hub, chrome Standard three-hole Standard four-hole 20 mm 3/4 in NPT 160 mm 3/4 in NPT 360 mm 3/4 in NPT 760 mm 3/4 in NPT Black Aluminum 20 mm 3/4 in NPT 160 mm 3/4 in NPT 360 mm 3/4 in NPT 760 mm 3/4 in NPT Right angle 3/4 in NPT Code L F Flashing base is f use with incandescent lamps. E26X 9 KM L 39R W V 4 Component Catalog No. E26S104 E26S108 E26S109 E26BHM E26BJM E26BKM E26BMM E26BHU E26BJU E26BKU E26BMU E26BRU Stacklight Component Description Catalog No. Standard Flashing E26BL E26BF_ Code 0 2 3 4 6 9 W R G Y B A W1 R1 G1 Y1 B1 A1 M E U V K Z X0 X2 X3 X4 X6 X9 Code W Q N P Description None Mono-tonal Bi-tonal Intermittent Component Catalog No. E26BQ_ E26BN_ E26BP_ Module Description Clear incandescent Red incandescent Green incandescent Yellow incandescent Blue incandescent Amber incandescent White cluster LED with clear lens Red cluster LED with red lens Green cluster LED with green lens Yellow cluster LED with yellow lens Blue cluster LED with blue lens Amber cluster LED with amber lens White cylindrical LED with clear lens Red cylindrical LED with red lens Green cylindrical LED with green lens Yellow cylindrical LED with yellow lens Blue cylindrical LED with blue lens Amber cylindrical LED with amber lens Flashing white cluster LED with clear lens Flashing red cluster LED with red lens Flashing green cluster LED with green lens Flashing yellow cluster LED with yellow lens Flashing blue cluster LED with blue lens Flashing amber cluster LED with amber lens Xenon flasher with clear lens Xenon flasher with red lens Xenon flasher with green lens Xenon flasher with yellow lens Xenon flasher with blue lens Xenon flasher with amber lens Voltage Code Description V1 12V V2 24V V3 48V V4 120V V5 240V Component Catalog No. E26B0_ E26B2_ E26B3_ E26B4_ E26B6_ E26B9_ E26BW_ E26BR_ E26BG_ E26BY_ E26BB_ E26BA_ E26BW1_ E26BR1_ E26BG1_ E26BY1_ E26BB1_ E26BA1_ E26BM_ E26BE_ E26BU_ E26BV_ E26BK_ E26BZ_ E26BX0_ E26BX2_ E26BX3_ E26BX4_ E26BX6_ E26BX9_ 4 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 Product Selection Assembled s One-, Two- and Three- Assembled Stacklights mountable Incandescent LED versions 24V and 120V versions One- Stacklight Volts AC/DC Two- Stacklight Three- Stacklight Note First Level Col Illumination Type 24V None Red Incandescent steady E26XWWL2W-V2 24V None Red Cylindrical LED steady E26XWWLR1W-V2 24V None Green Incandescent steady E26XWWL3W-V2 24V None Green Cylindrical LED steady E26XWWLG1W-V2 24V None Amber Incandescent steady E26XWWL9W-V2 24V None Amber Cylindrical LED steady E26XWWLA1W-V2 120V None Red Incandescent steady E26XWWL2W-V4 120V None Red Cylindrical LED steady E26XWWLR1W-V4 120V None Green Incandescent steady E26XWWL3W-V4 120V None Green Cylindrical LED steady E26XWWLG1W-V4 120V None Amber Incandescent steady E26XWWL9W-V4 120V None Amber Cylindrical LED steady E26XWWLA1W-V4 Volts AC/DC First Level Col Illumination Type Second Level Col Illumination Type 24V None Green Incandescent steady Red Incandescent steady E26XWWL32W-V2 24V None Green Cylindrical LED steady Red Cylindrical LED steady E26XWWLG1R1W-V2 120V None Green Incandescent steady Red Incandescent steady E26XWWL32W-V4 120V None Green Cylindrical LED steady Red Cylindrical LED steady E26XWWLG1R1W-V4 Volts AC/DC First Level Col Illumination Type Second Level Col Illumination Type LED modules have very low current draw and should not be used with triac output devices like PLC triac output modules. It is recommended that dry contact outputs be used to switch 120 Vac modules. Third Level Col Illumination Type 24V None Green Incandescent steady Amber Incandescent steady Red Incandescent steady E26XWWL392W-V2 24V None Green Cylindrical LED steady Amber Cylindrical LED steady Red Cylindrical LED steady E26XWWLG1A1R1W-V2 120V None Green Incandescent steady Amber Incandescent steady Red Incandescent steady E26XWWL392W-V4 120V None Green Cylindrical LED steady Amber Cylindrical LED steady Red Cylindrical LED steady E26XWWLG1A1R1W-V4 Control Products Catalog CA08102001E August 2010 www.eaton.com 5

.1 Stacklights and Xenon Strobe Modules modules include lens diffusers which provide even illumination and eliminate hot spots. /LED Module Xenon Strobe Module Xenon strobes emit a bright attention-getting white flashing light. Flash rate = 60/min. and Xenon Strobe Modules LED/Lamp Voltage Lens Col Notes Include lens, diffusers and lamps unless otherwise noted. Incandescent bulbs are AC/DC rated, LEDs are AC rated only. Xenon strobe modules occupy two positions in the stacklight assembly. Incandescent Cylindrical LED Cluster LED Cluster LED Xenon Steady Flashing Steady Only Steady Flashing Flashing Without bulb Red E26B2 E26B E26BR E26BR LED Green E26B3 E26BG E26BG E26BG Yellow E26B4 E26BY E26BY E26BY Blue E26B6 E26BB E26BB E26BB Amber E26B9 E26BA E26BA E26BA Clear E26B0 E26BW E26BW E26BW 12 Vac/Vdc Red E26B2V1 E26BR1V1 E26BRV1 E26BEV1 E26BX2V1 Green E26B3V1 E26BG1V1 E26BGV1 E26BUV1 E26BX3V1 Yellow E26B4V1 E26BY1V1 E26BYV1 E26BVV1 E26BX4V1 Blue E26B6V1 E26BB1V1 E26BBV1 E26BKV1 E26BX6V1 Amber E26B9V1 E26BA1V1 E26BAV1 E26BZV1 E26BX9V1 Clear E26B0V1 E26BW1V1 E26BWV1 E26BMV1 E26BX0V1 24 Vac/Vdc Red E26B2V2 E26BR1V2 E26BRV2 E26BEV2 E26BX2V2 Green E26B3V2 E26BG1V2 E26BGV2 E26BUV2 E26BX3V2 Yellow E26B4V2 E26BY1V2 E26BYV2 E26BVV2 E26BX4V2 Blue E26B6V2 E26BB1V2 E26BBV2 E26BKV2 E26BX6V2 Amber E26B9V2 E26BA1V2 E26BAV2 E26BZV2 E26BX9V2 Clear E26B0V2 E26BW1V2 E26BWV2 E26BMV2 E26BX0V2 48 Vac/Vdc Red E26B2V3 E26BR1V3 E26BRV3 E26BEV3 E26BX2V3 Green E26B3V3 E26BG1V3 E26BGV3 E26BUV3 E26BX3V3 Yellow E26B4V3 E26BY1V3 E26BYV3 E26BVV3 E26BX4V3 Blue E26B6V3 E26BB1V3 E26BBV3 E26BKV3 E26BX6V3 Amber E26B9V3 E26BA1V3 E26BAV3 E26BZV3 E26BX9V3 Clear E26B0V3 E26BW1V3 E26BWV3 E26BMV3 E26BX0V3 120 Vac Red E26B2V4 E26BR1V4 E26BRV4 E26BEV4 E26BX2V4 Green E26B3V4 E26BG1V4 E26BGV4 E26BUV4 E26BX3V4 Yellow E26B4V4 E26BY1V4 E26BYV4 E26BVV4 E26BX4V4 Blue E26B6V4 E26BB1V4 E26BBV4 E26BKV4 E26BX6V4 Amber E26B9V4 E26BA1V4 E26BAV4 E26BZV4 E26BX9V4 Clear E26B0V4 E26BW1V4 E26BWV4 E26BMV4 E26BX0V4 240 Vac Red E26B2V5 E26BRV5 E26BEV5 E26BX2V5 Green E26B3V5 E26BGV5 E26BUV5 E26BX3V5 Yellow E26B4V5 E26BYV5 E26BVV5 E26BX4V5 Blue E26B6V5 E26BBV5 E26BKV5 E26BX6V5 Amber E26B9V5 E26BAV5 E26BZV5 E26BX9V5 Clear E26B0V5 E26BWV5 E26BMV5 E26BX0V5 6 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 LEDs Cylindrical Cluster Cylindrical Stacklight LED Cluster LED Cylindrical Cluster LEDs Voltage Col Cylindrical LED Cluster LED Cluster LED Steady Only Steady Flashing 12 Vac/Vdc Red E26S110 E26S15 E26S48 Green E26S114 E26S19 E26S53 Yellow E26S112 E26S23 E26S58 Blue E26S115 E26S27 E26S63 White E26S116 E26S71 E26S75 Amber E26S111 E26S79 E26S84 24 Vac/Vdc Red E26S117 E26S16 E26S49 Green E26S121 E26S20 E26S54 Yellow E26S119 E26S24 E26S59 Blue E26S122 E26S28 E26S64 White E26S123 E26S72 E26S76 Amber E26S118 E26S80 E26S85 48 Vac/Vdc Red E26S124 E26S17 E26S50 Green E26S128 E26S21 E26S55 Yellow E26S126 E26S25 E26S60 Blue E26S129 E26S29 E26S65 White E26S130 E26S73 E26S77 Amber E26S125 E26S81 E26S86 120 Vac/Vdc Red E26S138 E26S18 E26S51 Green E26S142 E26S22 E26S56 Yellow E26S140 E26S26 E26S61 Blue E26S143 E26S30 E26S66 White E26S74 E26S78 Amber E26S139 E26S82 E26S87 240 Vac/Vdc Red E26S44 E26S52 Green E26S45 E26S57 Yellow E26S E26S62 Blue E26S47 E26S67 White E26S101 E26S102 Amber E26S83 E26S88 Control Products Catalog CA08102001E August 2010 www.eaton.com 7

.1 Stacklights Mounting s Components Standard - C Supply 6 5 4 3 2 1 1 2 3 4 5 6 C 1 2 3 4 5 6 Facty Wiring Field Wiring External Switching Devices Flashing Mounting s and Hubs Description Voltage Mounting Standard three-hole mounting base E26S108 Notes Audible alarm units must be wired via the steady circuit on flashing base units. Audible alarm units can be wired in positions as shown but only one unit is permitted on each stack and unit must occupy the last top mounting position. - C Supply 6 5 4 3 2 1 1 2 3 Flashing Circuit 7 8 Orange Wire 4 External Switching Devices Flashing Module 5 6 Steady Circuit 9 10 Description Voltage Standard F use with steady incandescent steady/flashing LED 12 Vac/Vdc to 240 Vac/Vdc E26BL Flashing Enables configuration of incandescent light modules f steady flashing operation 12 Vdc E26BFV1 24 Vac/Vdc E26BFV2 48 Vac/Vdc E26BFV3 120 Vac/Vdc E26BFV4 240 Vac/Vdc E26BFV5 Standard Three-Hole Mounting Standard Four-Hole Mounting Myers Type Hub Standard four-hole mounting base E26S109 Myers Type Hub 3/4 in NPT threaded hub E26S104 C 1 2 3 4 5 6 7 8 9 10 Orange Flasher Wire Flasher Voltage 12 Vdc 24 Vac/Vdc 48 Vac/Vdc 120 Vac/Vdc 240 Vac/Vdc Flasher Max. Allowable No. of Modules 2 4 6 6 6 8 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 s and Extension Tubes Components E26B_ Extension Tube A Extension Tube E26BRU A Audible s-nema Type 1 (IP20) Description Voltage Mono-Tonal 4.5 ma 12 Vac/Vdc E26BQV1 12.6 ma 24 Vac/Vdc E26BQV2 9.4 ma 48 Vac/Vdc E26BQV3 11.5 ma 120 Vac/Vdc E26BQV4 5.1 ma 240 Vac/Vdc E26BQV5 Bi-Tonal 4.5 ma 12 Vac/Vdc E26BNV1 12.6 ma 24 Vac/Vdc E26BNV2 9.4 ma 48 Vac/Vdc E26BNV3 11.5 ma 120 Vac/Vdc E26BNV4 5.1 ma 240 Vac/Vdc E26BNV5 Intermittent 4.5 ma 12 Vac/Vdc E26BPV1 12.6 ma 24 Vac/Vdc E26BPV2 9.4 ma 48 Vac/Vdc E26BPV3 11.5 ma 120 Vac/Vdc E26BPV4 5.1 ma 240 Vac/Vdc E26BPV5 Extension Tubes Description Voltage Extension A 0.79 in (20 mm) extension E26BHM 6.30 in (160 mm) extension E26BJM 14.17 in (360 mm) extension E26BKM 29.92 in (760 mm) extension E26BMM Extension A 0.79 in (20 mm) extension E26BHU 6.30 in (160 mm) extension E26BJU 14.17 in (360 mm) extension E26BKU 29.92 in (760 mm) extension E26BMU Right angle extension tube E26BRU Notes Volume adjustment range: 64 db to 90 db typical current draw (ma). F use with standard mounting base 3/4 in NPT threaded hub gray aluminum. F use with standard mounting base 3/4 in NPT threaded hub black aluminum. Control Products Catalog CA08102001E August 2010 www.eaton.com 9

.1 Stacklights Replacement Parts Stacklight Replacement Parts Description Replacement cover Replacement lens O-ring Notes Nmally included with stacklight base Nmally included with light modules Number in Diagram 1 E26S68 2 E26S106 Replacement lenses Clear 3 E26S38 Red E26S39 Green E26S40 Yellow E26S41 Blue E26S42 Amber E26S43 Replacement Xenon 12 Vac/Vdc 4 E26S33 strobe dual high (does not include lenses) 24 Vac/Vdc E26S34 48 Vac/Vdc E26S35 120 Vac E26S36 240 Vac E26S37 Replacement diffusers White nmally supplied 4 E26S31 with incandescent light modules Clear nmally supplied E26S32 with LED light modules Replacement lamps 12V 5 E26S8 24V E26S9 48V E26S10 120V E26S11 240V E26S12 Replacement extension tube O-rings Nmally included with extension tubes 6 E26S107 Replacement mounting gasket Lamp removal tool Nmally included with stacklight base F E26 and E22 incandescent lamps 7 E26S105 E22BA3 Notes Sold in packages of 5 pieces. F replacement LEDs, see table on Page 7. Sold in packages of 10 pieces. Mounting gaskets have two sets of mounting holes one set with center-to-center spacing of 1.75 in (44.5 mm) and another set with center-to-center spacing of 1.65 in (42 mm). Typical Stacklight Assemblies 1 Cover 2 O-Ring 4 Diffuser Terminal Board Set Screw Recommended Tightening Tque Is 7 in-lb (0.79 Nm) 7 Mounting Gasket Lens 3 Lamp 5 O-Ring 2 Typical Stacklight Assembly (Exploded View) Panel Alternate Conduit Hub Stacklight O-Rings 6 Extension Tube Mounting Myers Type ST-2 ST-2CP Hub 10 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 Technical Data and Specifications General Specifications Description Mechanical Ratings Shock (IEC 68-2-27) Vibration (IEC 68-2-6) Bump (IEC 68-2-29) Climate Conditions Operating Specification 11 ms, 15g 10 sweeps 10 150 Hz, 2g 1000 pulses, 6 ms, 15g Maximum 104 F (40 C) at 95% RH, Temperature 4 to 140 F ( 20 to 60 C) Temperature 40 to 176 F ( 40 to 80 C) Stage Materials Cover Polycarbonate Lenses Polycarbonate Stacklight base Nylon Extension tubes Aluminum Mounting base Zinc die cast Terminals Single conduct 14 30 AWG (2.5 0.05 mm 2 ) Two conducts (same size)) 18 26 AWG (0.75 0.14 mm 2 ) Do not mix solid and stranded wire in the same terminal Recommended tightening tque 4.4 5.3 lb-in (0.5 0.6 Nm) Electrical Ratings Insulation voltage (U i ) 690V Operational voltage (U e ) 250V Impulse withstand voltage (U imp ) 1.5 kv Bulb Specifications Incandescent lamp type BA15d Maximum lamp wattage 6W Bulbs average life Incandescent 7,000 to 12,000 hrs. (based on voltage) Xenon flasher 20,000 hrs. LED 60,000 to 100,000 hrs. (based on cols) LED/Incandescent Comparison Incandescent lamps Average operating life of 7,000 hours Each lamp can be used with any col lens Low cost results in sht term savings LED lamps Average operating life of 60,000 to 100,000 hours Low power consumption Extended life results in long-term savings Control Products Catalog CA08102001E August 2010 www.eaton.com 11

.1 Stacklights Ratings Published theetical lamp lives are based on ideal labaty conditions and should be used f comparison only. Actual life may be shter due to various application conditions. Stacklight Incandescent Application Data Type of Lamp Used Approximate Current, ma per 12V BA15d 417 7,000 24V BA15d 208 7,000 48V BA15d 104 7,000 110 140V BA15d 36 50 7,000 220 260V BA15d 23 27 12,000 Xenon Flasher Application Data Type of Lamp Used Approximate Current, ma per 12V DC 0 ma 20,000 AC 780 ma 20,000 24V DC 190 ma 20,000 AC 320 ma 20,000 48V DC 100 ma 20,000 AC 150 ma 20,000 120V AC 60 ma 20,000 240V AC 30 ma 20,000 Theetical Lamp Life, Hours as Applied Theetical Lamp Life, Hours as Applied LED Application Data Type of Note Col Cluster LED Approximate Current, ma at Rated Volts Cylindrical LED Approximate Current, ma at Rated Volts Continuous/Flashing Stacklight LED 12 Red 92 92 100,000 Vac/Vdc Amber 92 92 100,000 Yellow 92 92 100,000 Green 60 60 80,000 Blue 60 60 60,000 White 60 60 60,000 24 Red 47 47 100,000 Vac/Vdc Amber 47 47 100,000 Yellow 47 47 100,000 Green 59 59 80,000 Blue 59 59 60,000 White 59 59 60,000 48 Red 25 25 100,000 Vac/Vdc Amber 25 25 100,000 Yellow 25 25 100,000 Green 18 18 80,000 Blue 31 31 60,000 White 31 31 60,000 60 Red 25 25 100,000 Vac/Vdc Amber 25 25 100,000 Yellow 25 25 100,000 Green 18 18 80,000 Blue 17 17 60,000 White 17 17 60,000 120 Red 24 24 100,000 Vac/Vdc Amber 24 24 100,000 Yellow 24 24 100,000 Green 17 17 80,000 Blue 16 16 60,000 White 16 16 60,000 Represents average current draw, 1.6A peak f 120V and 0.8A peak at 240V. Theetical Lamp Life, Hours as Applied 12 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 Mounting Instructions Stacklight bases may be mounted without the use of an extension tube mounting base. If additional height is required, choose Mounting Customer Supplied Customer Supplied Stacklight Mounting Gasket Panel 0.8 30 in (20 760 mm) extension tubes that fit between the mounting base and stacklight base. The extension tubes are threaded Utilizing Extension Tube and Mounting Mounting Dimensions Approximate Dimensions in Inches (mm) Three-Hole Mounting f Mounting E26S108 0.18 (4.6) Dia. #8 32 Thread (M4 x 0.7) 1.75 (44.5) 1.65 (42.0) 0.87 (22.1) Dia. Set Screw Recommended Tightening Tque Is 7 in-lb (0.79 Nm) 1.92 (48.8) Dia. Stacklight O-Rings Extension Tube Mounting Mounting Gasket Panel 0.87 (22.1) Dia. 120 0.18 (4.6) Dia. #8 32 Thread (M4 x 0.7) with 3/4 in NPT threads, allowing f direct connection to conduit fittings threaded holes without the use of a mounting base. Utilizing Extension Tube and 3/4 In (19.1 mm) Conduit Hub Set Screw Recommended Tightening Tque Is 7 in-lb (0.79 Nm) Four-Hole Mounting f E26S109 Note Stacklight base and gasket are supplied as standard with two sets of base mount holes. One set with center-to-center spacing of 1.75 in (44.5 mm) and another set with center-to-center spacing of 1.65 in (42 mm). Stacklight O-Rings Extension Tube Myers Type ST-2 ST-2CP Hub Panel (Use Rubber-Jawed Pliers f Installation to Avoid Scratching the Black Anodized Coating) 2.12 (53.8) Dia. 0.20 (5.08) Dia. #10 32 Thread (M5 x 0.7) 0.87 (22.1) Dia. 90 Conduit Hub f E26S104 3/4 In (19.1 mm) 1.06 (27) Dia. Control Products Catalog CA08102001E August 2010 www.eaton.com 13

.1 Stacklights Dimensions Approximate Dimensions in Inches (mm) Standard and Flashing s s Notes 2.32 (59) 2.56 (65) 1.75 (44) 0.59 (15) 1.69 (42.9) s also suitable f mounting with extension tubes listed on Page 9. Mounting gasket and cover are supplied as standard with stacklight bases. Assembled Extension Tubes Right Angle Extension Tubes A Tube Extension Height A 0.79 (20) 1.77 (45) 6.30 (160) 7.28 (185) 14.17 (360) 15.16 (385) 29.92 (760) 30.91 (785) 2.00 (50.8) 2.50 (63.5) 14 Control Products Catalog CA08102001E August 2010 www.eaton.com

Stacklights.1 Approximate Dimensions in Inches (mm) One- Stacklight Standard With With Xenon Flasher 0.59 (15) Two- Stacklight Standard With With Xenon Flasher 0.59 (15) 2.24 (57) 2.24 (57) 0.59 (15) 0.59 (15) Xenon (2 High) Xenon (2 High) Control Products Catalog CA08102001E August 2010 www.eaton.com 15

.1 Stacklights Approximate Dimensions in Inches (mm) Three- Stacklight Standard With With Xenon Flasher 0.59 (15) Modules Standard 0.59 (15) 2.72 (69.1) Note Cover included with stacklight base. 2.24 (57) Xenon 0.59 (15) 2.72 (69.1) 2.72 (69.1) 0.59 (15) Xenon (2 High) 16 Control Products Catalog CA08102001E August 2010 www.eaton.com