CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Similar documents
SUBMERSIBLE WATER PUMPS

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

SUBMERSIBLE DIRTY WATER PUMP

SUBMERSIBLE WATER PUMP. Model Nos. CSE1 - CSE1A - CSE2 - CSE2A CSD3- -CSD3A CSV1A - CSV2 - CSV2A - CSW1A OPERATING & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

DEVIL CERAMIC SPACE HEATERS

FAN HEATER. Models: DEVIL OPERATING & MAINTENANCE INSTRUCTIONS

DUST EXTRACTOR MODEL No: CDE1000

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

MOBILE PARTS WASHER MODEL No: CWM20

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

ORIGINAL INSTRUCTIONS

COLD WATER WASHER OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. ELS140, 140R & ELS150. Part Nos , &

NON-SUBMERSIBLE WATER PUMP

3KW ELECTRIC FAN HEATER

2.8KW ELECTRIC FAN HEATER

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

GAS HEATERS Models: Little Devil (inc ss), Devil 650/660(ss), Devil 850/860(ss), Devil 1250/1260(ss), Devil 1850, Devil 3000 & Devil 3150

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

5KW ELECTRIC FAN HEATER

ELECTRIC ASH CAN Model: CVACASH500 Part No:

DUST EXTRACTOR MODEL No: CDE7B

1/3 SHEET ORBITAL SANDER MODEL No. COS200

15KW ELECTRIC FAN HEATER

900W OIL FILLED RADIATOR

2 KW OIL FILLED RADIATOR

30KW ELECTRIC FAN HEATER

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

OPERATING & MAINTENANCE INSTRUCTIONS

20 LITRE DEHUMIDIFIER

WET & DRY VACUUM CLEANERS

PARAFFIN/DIESEL HEATERS

Model Nos CBM100SS, 130SS, 250SS, 240 & 240E CPE100P, 100TF, 120 & 130SS HANDY PUMP 2 OPERATING & MAINTENANCE INSTRUCTIONS 0406

DUST/CHIP EXTRACTOR OPERATING & MAINTENANCE. MODEL No. CDE7B INSTRUCTIONS. Part Part No

ELECTRIC FAN HEATERS

POWER WASHER MODEL NO: JET 9000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

submersible water pumps

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

OPERATING & MAINTENANCE INSTRUCTIONS

1300W Pressure Washer RACHP133A

2 KW OIL FILLED RADIATOR

18 INCH HIGH VELOCITY FLOOR FAN

PARTS WASHER Model: CW1D Part No:

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Model No: Little Devil II (inc ss)

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

24 & 30 INCH DRUM FANS

ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

PARTS WASHER Model: CW2D Part No:

Sip Vacuum Cleaner 1400/35 Wet & Dry

INDUSTRIAL VACUUM CLEANER WITH AUTO START/STOP

VARIABLE SPEED JIG SAW MODEL No. CJS350. MODEL No. CROS1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

Mobile Air Conditioner Instruction Manual Model TC-N9KM

DIRTY WATER SUBMERSIBLE PUMP

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

PARAFFIN/DIESEL HEATER

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

GAS HEATERS MODEL NOS: 900DV,1600DV & 2100DV PART NOS: , & USER INSTRUCTIONS ORIGINAL INSTRUCTIONS LS ISS 1

6000, 8000, & 15000

SUBMERSIBLE WATER PUMP

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

DIRTY WATER SUBMERSIBLE PUMP KIT

DIRTY WATER SUBMERSIBLE PUMP

V80-H Multistage Pump Instruction Manual

PORTABLE AIR CONDITIONER MODEL NO: AC9000

MODEL NO: CW2D PART NO: OPERATING & MAINTENANCE INSTRUCTIONS

DIESEL/PARAFFIN HEATERS

INSTRUCTION MANUAL Model: SU3022

HOT WASHER MODEL NO: KING150

VADA - Rain2Main Automatic Rainwater Controller

Heated Display. Instruction manual. Model: CW147 / CW148

150MM ELECTRIC EARTH BORER

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

CLEAN WATER SUBMERSIBLE PUMP

DRY:SOON TOWEL WARMER


10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

INSTALLATION GUIDE NZ AU C

INSTALLATION & USER INSTRUCTIONS

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

INSTALLATION & USER INSTRUCTIONS

Mini Tower Fan NSMTF-18

Vacuum Cleaner MC-E3003 MC-E3001. Operating Instructions. Model No.

POWER WASHER MODEL NO: JET 8000 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING: Do not use the machine without reading this manual PART NO:

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153


ELECTRIC FAN HEATERS Devil 6002, 6003, 6005, 6009 & 6015

2 IN 1 SUBMERSIBLE PUMP

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514

Operating Instructions

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

GAS HEATERS MODEL NOS: DEVIL 700, 900/910SS,1600/ 1610SS & 2100 PART NOS: , , , , , &

APW-VAP-150P High Pressure Cleaner Operator Manual

Operating Instructions UniTech Perfect

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

INSTALLATION & USER INSTRUCTIONS

Transcription:

CLEAN WATER PUMP MODEL No: Hippo4A Part No: 7230535 OPERATION & MAINTENANCE INSTRUCTIONS 0807

INTRODUCTION Thank you for purchasing this CLARKE clean water pump. This highly efficient pump is designed for pumping clean water only, and is ideal for draining ornamental ponds, swimming pools etc. GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months. Please keep your receipt as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not effect your statutory rights. CONTENTS Introduction... 2 Guarantee... 2 Contents... 2 Specifications... 3 For your own safety... 4 Electrical connections... 5 Parts identification... 6 Recommended uses... 7 Preparation... 8 Using the pump... 9 Cleaning and maintenance... 10 Troubleshooting... 11 2

SPECIFICATIONS Hippo4A M otor 230V 50Hz 1Ph. Motor Output Head Max Maximum Imersion Depth Max. Outlet Flow Rate Fittings Dimensions ( L x W x H ) 214 Watts 5.5 meters 8 meters 100 l/min 1 1/4 BSP Threaded 150 x 197 x 223 mm D uty Cycle S3-2 Hours* Sand handling Capacity Maximum Solid Body Diameter 3 30 g/m 5 mm Part No. 7230535 * Duty Cycle = 2 hours on, followed by 1 hour off. 3

FOR YOUR OWN SAFETY KEEP CHILDREN AWAY Do not allow children to touch the pump, cables or connections. USE A RESIDUAL CURRENT DEVICE: The pump must be connected to a high sensitivity residual current device (RCD) which has a tripping current of less than 30mA. STORAGE When not in use, the pump should be stored in a dry, secure place out of the reach of children. WATER TEMPERATURE Do not use the pump if the water is liable to freeze, as this can cause damage to the pump. MAINS SUPPLY Disconnect the pump from the mains supply when not in use. REPAIRS Have the pump repaired by a qualified person. DO NOT ABUSE THE MAINS LEAD Never carry the pump by the mains lead. Never pull the mains lead to disconnect the pump from the mains socket. Keep the mains lead away from heat, oil and sharp edges. Always check the plug, mains cable and float switch cable for damage before use. Do not use the pump if damaged. Refer to qualified service personnel for repair. If you have to use an extension lead with this product, it must be designed for outdoor use and incorporate a cable suitable for use with Class I appliances. Do not lower the pump using the mains lead, Always use the handle with a rope or cord attached if necessary. DO NOT ABUSE THE FLOAT SWITCH Do not lift the pump by the mains or float switch cables. 4

ELECTRICAL CONNECTIONS Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch. WARNING! THIS APPLIANCE MUST BE EARTHED IMPORTANT: The wires in the mains lead are coloured in accordance with the following code: Green & Yellow - Earth Blue - Neutral Brown - Live As the colours of the flexible lead of this appliance may not correspond with the coloured markings identifying terminals in your plug proceed as follows: Connect GREEN & YELLOW wire to terminal marked with a letter E or Earth symbol or coloured GREEN or GREEN & YELLOW. Connect BROWN wire to terminal marked with a letter L or coloured RED. Connect BLUE wire to terminal marked with a letter N or coloured BLACK. If this appliance is fitted with a plug which is moulded onto the electric cable (i.e. nonrewireable) please note: 1 The plug must be thrown away if it is cut from the electric cable. There is a danger of electric shock if it is inserted into a mains power socket. 2 Never use the plug without the fuse cover fitted. 3 When replacing a detachable fuse carrier, ensure the correct replacement is used (as indicated by marking or colour code). 4 Replacement fuse covers can be obtained from your local dealer or most electrical stockists. FUSE RATING The fuse in the plug must be replaced with one of the same rating (13 amps) and this replacement must be ASTA approved to BS1362. We strongly recommend that this machine is connected to the mains supply via a Residual Current Device (RCD) If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself. 5

RECOMMENDED USES The recommended uses for this pump are: Drainage after flooding The transfer of liquids Drainage of containers Taking water from wells and shafts Liquids that CAN be pumped: Clean water Contaminated water (maximum particle size 5 mm) Swimming pool water Note: After pumping chlorinated water or other liquids containing additives, the pump should be rinsed with clean water Soapy water Liquids that MUST NOT be pumped are: Corrosive substances Combustible or explosive substances (petrol, thinners etc.) Fats, oils or salts Waste from toilets or urinals 6

PARTS IDENTIFICATION Handle Pump Base Float Switch May be supplied fitted to the pump Multi Hose Adaptor 1/2 3/4 1 Elbow 7

PREPARATION CONNECTING THE MULTI HOSE ADAPTOR WARNING! DISCONNECTED THE PUMP FROM THE MAINS POWER SUPPLY BEFORE CONNECTING THE MULTI HOSE ADAPTOR An Elbow is provided with a 1-1/4 BSP thread at either end as shown in the diagram opposite. Multi Hose Connector Ensure the end fitted with an O-Ring is screwed into the pump. Screwed on to the other end of the elbow, is a multi hose connector capable of accepting 1, 3/4 or 1/2 hoses. Simply cut the multi hose connector to the required size and attach a suitable hose using with a worm drive clip. Elbow For maximum efficiency, we strongly recommend that you connect a 1 diameter hose to the multi hose adapter, Alternatively, you may remove the multi adapter altogether, and screw on a 1-1/4 BSP hose adapter The pump is completely submersible, and should be placed in a vertical position, on a solid flat surface, Placing the pump on a couple of house bricks if required. SUITABLE HOSES, and SPARE/REPLACEMENT MULTI HOSE ADAPTERS ARE AVAILABLE FROM YOUR CLARKE DEALER 8

USING THE PUMP CAUTION! CHECK THE PUMP FOR DAMAGE BEFORE USE, DO NOT USE THE PUMP IF IT IS DAMAGED IN ANY WAY 1 Place the pump on a flat surface in the area that you want to drain. If there is sediment in the operating area, the pump should be placed on house bricks, or similar. Ensure the pump is positioned with adequate space so that the movement of the float switch is not restricted - recommended minimum area of 40 x 40cm ALWAYS raise and lower the pump using a rope attached to the lifting handle. Take all necessary precautions as described on page 4 before plugging in, and switching ON. WARNING! NEVER CARRY THE PUMP USING THE MAINS POWER CABLE. DAMAGE TO ELECTRICAL CABLES CAN BE HAZARDOUS. ALWAYS USE THE HANDLE WHEN MOVING THE PUMP. 2 Connect the mains plug to a high sensitivity residual current device (RCD) which has a tripping current of less then 30mA. 3 Switch the mains power supply on, The pump incorporates a float switch, which automatically switches the pump ON when the water is above a pre-determined level. 4 The pump will begin to drain water. As the water level falls, so will the float switch, until it stops the pump. 5 When the pumping is finished, disconnect the pump from the mains power supply The pump is fitted with a thermal cut out to protect the motor from overheating. If the thermal cut out activates, the motor will automatically switch back on when it has cooled down sufficiently. CAUTION! DO NOT ALLOW THE PUMP TO RUN DRY. 9

CLEANING AND MAINTENANCE WARNING! MAKE SURE THAT THE PUMP IS DISCONNECTED FROM THE MAINS SUPPLY BEFORE CLEANING, OR PERFORMING ANY MAINTENANCE. These pumps should require no maintenance other than regular cleaning. If the pump starts to show signs of wear or damage, contact your CLARKE dealer for advice. Do not attempt to repair the pump yourself, repairs must be carried out by your CLARKE dealer, or contact the CLARKE Service Department, on 020 8988 7400. Check the pump regularly to ensure the base is clear of leaves or other debris. Replacing the Impeller 1 Remove the 3 screws on the base of the pump, and remove the cover. 2 Use a small flat headed screwdriver to remove the circlip. 3 Pull the old impeller off of the shaft. 4 Replace with a new impeller and lock it in place using the circlip. 5 Replace the base and use the 3 screws to secure. 10

TROUBLE SHOOTING PROBLEM PROBABLE CAUSE P ump will not start. Water level too low - float switch in OFF position. Float switch may be jammed against prevented from moving. side wall, or Pump will start but not pump. Check that the base is not blocked. Discharge tube clogged or obstructed. The head may be too great, i.e. you are trying to lift the water too great a distance for the pump to cope with. (See specification chart page 3). Air lock in the pump, produced during the plunge. Plunge the pump again, at an angle, and shake it whilst lowering to remove any air trapped in the system. Impeller may be damaged - Consult your CLARKE dealer. Pump will not stop. Float switch may be prevented from moving to the fully down position. Float switch may be faulty. dealer for advice. Consult your CLARKE Pump stops running. Thermal overload has operated. If this condition persists, investigate the cause. DO NOT attempt to pump anything other than clean water. Pump has run dry, or float switch has cut in. A foreign object has jammed the impeller. PARTS & SERVICE CONTACTS For spare parts and service, please contact your nearest dealer, or CLARKE International, on one of the following numbers. PARTS & SERVICE TEL: 020 8988 7400 or e-mail as follows: PARTS: parts@clarkeinternational.com SERVICE: service@clarkeinternational.com 11