THERMAL ANALYSIS OF CAR AIR COOLER

Similar documents
Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

*Corresponding author;

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Low GWP Refrigerants for Air Conditioning Applications

Chapter 10. Refrigeration and Heat Pump Systems

Design, Manufacturing of Chilled Water System for Process Cooling Application

A Comparison Between Refrigerants Used In Air Conditioning

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Heat pump supplemental heating system for motor vehicles

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

Oyelami S., Bolaji B. O.

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Brazed Plate Heat Exchanger for CO Applications

COMPARATIVE PERFORMANCE ANALYSIS OF EXPERIMENTAL FRIGORIFIC AIR CONDITIONING SYSTEM USING R-134A AND HFO-1234YF AS A REFRIGERANT

Computerized Simulation of Automotive Air-Conditioning System: A Parametric Study

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

η second law = Second law efficiency

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Sarthak Thakar, 2 R.P.Prajapati 1

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Pressure Enthalpy Charts

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Technical Information

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Chapter 9. Refrigeration and Liquefaction

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Development of Energy Efficient R-134a Automotive Air Conditioning System Using Internal Heat Exchanger

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Adsorption refrigeration system using waste heat

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

R-404A Alternative with Low Compressor Discharge Temperature

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

Figure 1: Overview of CO 2 evaporator types

II. OBJECTIVE OF RESEARCH

R07. Answer any FIVE Questions All Questions carry equal marks *****

Thermodynamics II Chapter 5 Refrigeration

Performance Study on A Window Type Air Conditioner Condenser Using Alternative Refrigerant R407C

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Executive Summary. Number of Low Number of High Number of Faults , Number of OK

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Performance of an Improved Household Refrigerator/Freezer

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Tube-in-tube heat exchanger Type HE

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Transcription:

Journal of KONES Powertrain and Transport, Vol. 8, No. THERMAL ANALYSIS OF CAR AIR COOLER Daniel Trzebiski Silesian University of Technology, Institute of Thermal Technology Konarskiego Street, - Gliwice, Poland tel.: +8 7 97, fax: +8 7 78 e-mail: daniel.trzebinski@polsl.pl Ireneusz Szczygie Silesian University of Technology, Institute of Thermal Technology Konarskiego Street, - Gliwice, Poland tel.: +8 7 8, fax: +8 7 78 e-mail: Ireneusz.szczygiel@polsl.pl Abstract People more and more time spend in vehicles (cars, trains, planes, buses or subway). This is the reason why the thermal comfort has more and more paid attention. In one hand people try to make comfort (in each situation) whatever they are at home, office or in car. In the other hand the thermal conditions in the cabin of vehicles directly influences on the driver's and passengers safety. The investigations presented in this paper are the part of larger project, which assumes complex modelling of thermal state of car interior. First part assumes creation of CFD model of car interior. Second part is thermodynamic modelling of air cooling unit in order to estimate the influence of basic cabin parameters on the A/C unit COP, power consumption of the unit and fuel consumption of the vehicle. In the paper thermodynamic analysis of car air cooler is presented. Typical refrigerator cycles are studied: one with uncontrolled orifice and non controlled compressor, second with thermostatic controlled expansion valve and externally controlled compressor. The influence of refrigerant charge and the inlet air temperature on the coefficient of performance, exergy efficiency, heat flux and temperature in evaporator and compressor net power were investigated. The impact of improper refrigerant charge on the performance of A/C systems was also checked. Keywords: car air conditioning, refrigerant, thermal comfort, thermodynamic cycle. Thermal comfort in vehicles Car compartment is a place where often thermal discomfort is obvious. In summer, the most important phenomenon of energy transfer is sun radiation. In hot summer day radiation heat flux can be even several times higher than convection heat flux. It can be easy to notice when one takes car to shady road after driving in the sun. Coldness and freshness feeling is almost immediate. Temperature in a vehicle cabin is closely related with the occurrence of traffic accidents []. In hot summer days internal temperature often exceeds + C. Zlatoper [8] has created the ranking list of the factors which affect the traffic accidents in United States and placed the temperature on the third position. So it is obvious, that the thermal conditions in the cabin of vehicles directly influences on the driver's and passengers safety. Both too high and too low ambient temperature influences human physical and mental state. Driver's efficiency researches indicate that it can be even % higher at + C than at + C. Decrease of efficiency at + C can be the same as that at + C [8][8]. It is impossible to ensure temperature at the same level as outside compartment using only ventilation, even with the strong flow. The internal temperature is almost always higher. Radiation

D. Trzebiski, I. Szczygie heat flux with green house effect in car compartment is higher that heat flux which can be refuse with ventilation. Situation is critical during car parking in hot clearly day with direct sun exposure. In summer, internal temperature can even reach 7 o C with o C outside. It is very dangerous for animals or children left inside car []. The techniques of achieving quite good effects of thermal comfort are well recognized in the habitats, but in mobile spaces, like cars, trains and buses are still under development. There are also additional parameters, which influence on the thermal comfort: air flow speed, air humidity, outer wall temperature and, what is important in vehicles cabins, sun radiation. In many cases thermal parameters are controlled only by regulation of the air temperature and the mass flow rate. Due to that, air flow speed can locally exceed its reasonable value. It is hard to strictly define the thermal comfort. Usually thermal comfort means that temperature is between C and C, humidity is about % and air velocity is under. m/s. This can be called independent factors. There is also second group of factors affecting thermal comfort individual human feelings which are much harder to define, because each person has their own preferences for thermal comfort. One can say there is thermal comfort when amount of people saying I fell badly here is the lowest []. The symptoms of thermal discomfort are intensive sweat production, increment of heart beat frequency, and as a result, the decrease of driver concentration and efficiency.. Thermal analysis of refrigerator cycle The heat flux which should be transferred out of the car cabin is about kw [] [6]. The only way to achieve internal temperature at desire level is use air conditioning systems. An optimum A/C unit should assure thermal comfort under time varying thermal loads with minimal energy consumption. Compressor in the unit is driven by the vehicle engine and therefore considerably increases the fuel consumption. In the paper three types of unit are considered. First with uncontrolled orifice and non controlled compressor (fixed piston displacement, Ra as refrigerant non controlled cycle), second with thermostatic controlled expansion valve assuring K superheating of refrigerant at compressor inlet and externally controlled compressor (piston displacement from 6 to cm, Ra controlled cycle), third with thermostatic controlled expansion valve assuring K superheating of refrigerant at compressor inlet and externally controlled compressor (piston displacement from to cm, R7 controlled cycle). All cases work with compressor speed and rev/min. Nominally refrigerant charge Ra is. kg. The charges. kg (% nominal) and. kg (% nominal) were also considered. For R7 nominally refrigerant charge is. kg. The charges. kg (% nominal),. kg (% nominal) and.7 kg (% nominal) were considered. Air temperature changes from C to C. The refrigerator scheme is shown in figure. For the simulations commercial software Kuli was used []. As it was mentioned, the aim of the investigations was the influence of refrigerant charge and inlet air temperature on the air A/C unit parameters: COP (), exergy efficiency - Carnot (), heat transferred in evaporator - Q evap (), refrigerant temperature inside evaporator and compressor driving power. The parameters are defined in the following way [6]: Q evap COP, () Q comp T T, cond evap carnot COP () Tevap

Thermal Analysis of Car Air Cooler M ( h ) h, () Q evap where: T cond - condenser temperature, K, T evap - evaporator temperature, K, h - refrigerant enthalpy at the evaporator outlet, kj/kg, h - refrigerant enthalpy at the evaporator inlet, kj/kg, M - refrigerant factor mass flow rate, kg/s.. Non controlled cycle In this case as expansion valve is orifice and everything depends on orifice effective throttle area. If the area is too high the compressor works properly (without fluid droplets) only in some range. If effective throttle area is too low the refrigerant at evaporator outlet is always superheated but the temperature at compressor outlet can be too high. That high temperature involves other problems. First is higher compressor material durability, second is a problem with liquid phase at condenser outlet, especially with higher ambient air temperature. 6 COP /. /. /. /. /. /. Fig.. COP as a function of ambient temperature When the refrigerant is not liquid or subcooled, efficiency of the system decreases significantly. In this case, at C irrespectively of refrigerant charge, COP is about for rev/min and for rev/min and decreases of at C air temperature. For. kg charge the drop is about for rev/min and for rev/min. It is shown in figure. Similar trend can be observed with heat transferred in evaporator. For the charge. kg and. kg, the heat flux increases with air temperature. It is shown in figure 6. For C the heat flux is two times higher than for C. For the charge. kg the situation is opposite heat flux decreases with air temperature. There is one advantage of. kg charge case: compressor power is low: at rev/min is below kw while for. kg is twice higher. But here is almost impossible to achieve required temperature inside car cabin in this case. Heat transferred in the evaporator is just too low (figure ).

D. Trzebiski, I. Szczygie Evaporator heat flux [kw] /. /. /. /. /. /. Fig.. Evaporator heat flux as a function of ambient temperature For the. and the. kg charge exergy is at the same level in whole temperature range and is about -%. For the. kg, charge decreases to % at o C air temperature. It is shown in figure. 6 Efficiency compared with CARNOT [%] /. /. /. /. /. /. Fig.. Exergy efficiency as a function of ambient temperature. Controlled cycle In this case there is no problem with too high temperature, because expansion valve always assures K of superheating. So there is no problem with high temperature material durability, because temperature at compressor outlet is lower too. If the temperature at compressor outlet is lower it is also easier to obtain liquid phase at condenser outlet. One can say the controlled cycle is more flexible. In this case heat flux in evaporator can be about. kw higher than in non controlled one, which means that we can reject. kw of heat

Thermal Analysis of Car Air Cooler flux more from car compartment. For. kg charge, compressor inlet (evaporator outlet) temperature is about C at C air temperature. COP /. /. /. /. /. /. Fig.. COP as a function of ambient temperature 6 Evaporator heat flux [kw] /. /. /. /. /. /. Fig.. Evaporator heat flux as a function of ambient temperature It means that temperature at compressor outlet can be about C. For other charges, inlet temperatures are similar and always below C. COP tendency is similar to non controlled cycle but the values are a little bit lower (figure ). The compressor power is always higher than in non controlled cycle. There is also higher heat flux in evaporator for both and rev/min cases (figure ). For the charge. kg COP is equal to. at C air temperature. Efficiency trend is similar to non controlled cycle. For. and. kg charge values are a little bit higher than in non control cycle. Opposite situation is for. kg charge, efficiency decreases to zero with air temperature. It is shown in figure 6.

D. Trzebiski, I. Szczygie Comparing the cases one can say that non controlled case is better than controlled one. COP values are higher for uncontrolled, compressor power is lower (lower fuel consumption), but on the other hand heat flux in evaporator is lower and refrigerant temperature is higher. Additionally it should be stressed out, that for the charge. kg compressor works only with vapour phase. For the charge. kg it works with vapour phase above C air temperature. For the charge. kg liquid always appears in compressor. 7 Efficiency compared with CARNOT [%] 6 /. /. /. /. /. /. Fig. 6. Exergy efficiency as a function of ambient temperature. All the simulations show how important is proper refrigerant charge in A/C systems. It is impossible to estimate the amount of refrigerant in the cycle without special measuring instruments. There is only one symptom to say that refrigerant charge is too low the outlet air temperature from A/C is too high. Exaporator heat flux [kw] 7 6 /. /. /. /. /. /. /.7 /.7 Fig. 7. Evaporator heat flux as a function of ambient temperature A/C cycle with CO (R7) as refrigerant was also considered. In this case refrigerant is in supercritical phase between compressor outlet and expansion valve inlet. Pressure levels are also different. At compressor outlet is up to bar (about bar for Ra cycle) and at evaporator

Thermal Analysis of Car Air Cooler outlet is about 8 bar (about. bar for Ra). This cycle can also be called controlled cycle because expansion valve always achieve K superheating at evaporator outlet. It can be noticed that evaporator heat flux is much lower for.7kg charge both at and at rpm. The difference increases with air temperature. Heat flux is over twice lower for.7kg than for other charges. It is almost impossible to achieve required temperature inside car cabin in this case. Heat transferred in the evaporator is just too low. It is shown in figure 7. COP value is similar for all charges in whole air temperature range. Except.7 kg, it is between. and. This value is lower than Ra cycle but still over, even for o C air temperature. For.7kg charge COP value is near at rpm and decrease to. at rpm (figure 8). COP /. /. /. /. /. /. /.7 /.7 Fig. 8. COP as a function of ambient temperature (R7) Efficiency compared with CARNOT [%] /. /. /. /. /. /. /.7 /.7 Fig. 9. Efficiency compared with CARNOT as a function of ambient temperature (R7) Exergy efficiency of the cycle is lower than for Ra. Difference is significant at high air temperature. For Ra cycle efficiency is between and 6% for whole air temperature range: only for the lowest charge decrease to %, for uncontrolled or near % for controlled cycle. For CO cycle efficiency is lower. The efficiency is the highest for. kg charge at o C and

D. Trzebiski, I. Szczygie decrease with air temperature, except.7 kg charge when is between and % for whole air temperature range. It is shown in figure 9.. Conclusions In the paper the thermal analysis of A/C unit cycle are presented. Basing on the simulations to date, it can be noticed that the decrease of the refrigerant charge decreases COP both for Ra and for CO as refrigerant.. For Ra case, decrease is higher in controlled cycle because the temperature in evaporator is higher which causes lower heat flux in evaporator and higher compressor power. Beneficial is that compressor works always with gas phase. For non controlled Ra cycle efficiency is higher but the hazard of compressor work with liquid appears. For CO case COP values are on the same level for all temperature, except. kg charge when it decreases significantly with air temperature. It can be noticed that COP values are lower than for Ra cycle. In all cases COP is lower when refrigerant charge is below its nominal value. There is one advantage of CO usage as refrigerant over Ra. Global Warming Potential (GWP), which is measure representing potential of a substance to contribute to the global warming, is for Ra and only for CO. It means kg Ra emission is equal kg of CO. Ozone Depletion Potential is zero for both cases. Car units are not so hermetic like home air conditioning. If it takes into account how many cars are equipped in A/C systems, emission from mobile systems has significant part in global green gas emission. References []. Cengiz, T. G., Babalik, F. C., An on-the-road experiment into the thermal comfort of car seats, Applied Ergonomics Volume, 8, Issue,, May, 7, pp. 7-7. []. Daanen Hein, A. M., van de Vliert, E., Huang, Xu, Driving performance in cold, warm and thermoneutral environments, Applied Ergonomics Volume,, Issue, 6, November,, pp. 97-6. []. Grundstein, A., Meentemeyer, V., Dowd, J., Maximum vehicle cabin temperatures under different meteorological conditions, International Journal of Biometeorology (9), pp.-6. []. KULI software, http,//www.kuli.at. []. Kwasniowski, S. (red), Ogrzewnictwo, wentylacja i klimatyzacja w pojazdach mechanicznych, Wrocaw, Nawigator, 99. [6]. Trzebinski, D., Szczygiel, I., Analiza komfortu cieplnego kabiny pasaerskiej samochodu osobowego, Systems 8, Volume, Special Issue /. [7]. Zhang, Y., Zhao, R., Overall thermal sensation, acceptability and comfort, Building and environment (8) -. [8]. Zlatoper, T., Determinants of motor vehicle deaths in the United States, a cross-sectional analysis, special issue, theoretical models for traffic safety, Accid. Anal. Prev. (), 99 pp. -6. 6