BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

Similar documents
BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

CHEF BASE CABINETS Installation, Operation and Maintenance Instructions

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

User Manual. Commercial School Milk Cooler User s Manual. Commercial School Milk Coolers: MC34, MC49, MC58

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

ICE CREAM TOPPING CABINETS REFRIGERATOR or FREEZER Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Installation and Operation Guide For

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Refrigerators. Technical Manual and Replacement Parts List FORM NO REV H MODEL SKTTR7FW MODEL SKC1220W

Glass Door Merchandiser Refrigerator and Freezer

Installation and Operation Guide For

Solid Door Top Mount Reach-In Freezer

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

COUNTER TOP REFRIGERATION MODEL SERIES HUBM-2RB/HUBM-2FB/HUBM-3.5RB/HUBM-3.5FB HUBM-2R/HUBM-2F/HUBM-3.5R/HUBM-3.5F

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

Chef Base Refrigerators

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

EQUIPMENT CARE AND CLEANING

Glass Door Refrigerators

Technical Manual and Replacement Parts List. f Real Freezers

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

INSTALLATION and OPERATION INSTRUCTIONS

User Manual. Commercial Refrigerator And Freezer User s Manual

COMMERCIAL REFRIGERATOR AND FREEZER USER S MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

INSTALLATION and OPERATION INSTRUCTIONS

TECHNICAL MANUAL F49-S, F49-SH F72-S, F72-SH R49-S, R49-SH, R49-G R72-S, R72-SH, R72-G - 1 -

SERIES NAV S Display Merchandisers

G-10f/GCG-10f UPRIGHT COOLER

11 0 Wo o d c r e s t R o a d, C h e r r y H i l l, N J For Models: VR-1, VR-2, VR-3 VF-1, VF-2, VF-3

BLG-HGP Model Bottom Mounted Full-Length Swing Glass Door Freezer Merchandisers

Installation & Operation Manual Undercounter & Prep. table units

INSTALLATION AND OPERATION MANUAL

SCIENTIFIC WARMING CABINET Installation, Operation and Maintenance Instructions

ref. com Owner s Manual for models: A Step Above the Standard Thank you for choosing EVEREST

Installation & Operations Manual for R-290 SERIES. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers 2/

Beverage Air IMPORTANT

Hoshizaki America, Inc.

Installation & Operations Manual for. BMG-HGP Model Bottom Mounted Full-Length Swing Glass Door Refrigerator Merchandisers. 4/17 Rev.

Outdoor and Indoor Electric Refrigerator Model COAR

Upright Chiller & Freezer Service, Installation and Care Manual

GCG-26c. Instruction Manual. G-Series Cooler

Technical Manual and Replacement Parts List. Mobile Freezer

GLASS DOOR MERCHANDISER REFRIGERATOR & FREEZER. Installation, Operation and Maintenance Instructions

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

This manual describes how to operate and care for your appliance to get the best, most efficient, performance. READ THIS BOOK!

Instruction Manual. Commercial Series Refrigerated Kitchen Equipment Models Reach-In S-Series. hoshizakiamerica.com

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

Drop-In Refrigeration System

Installation and User's Manual for Refrigerator Model SCR33

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

BMG-HGP & BMG-SLP Model Bottom Mounted Full-Length Glass Door Refrigerator Merchandisers

BSD SERIES REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

Installation and Operation Instructions

Isotemp Plus General Purpose Laboratory Freezers

Operation Manual and Parts Directory

SERVICE MANUAL Undercounter Refrigerator Drawer Units

Installation, Operation & Troubleshooting Instructions Pizza Table Refrigerator

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

User Manual. SKOPE Backbar, Counterline & Slimline BB, CL & CC Series. 1, 2 & 3 Door Horizontal Chillers. MAN11015 Rev. 2.0 Feb.

REF Series Undercounter Refrigerator

Glass Door Undercounter and Countertop Freezers

Preparing the Cabinet

INSTRUCTIONS FOR OPERATION AND CARE OF. P.O. Box 3527 City of Industry, CA, , U.S.A

Refrigerator Freezer Installation and Operation Manual

Refrigerator Freezer Installation and Operation Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

40KMC KMQ

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Owner s Guide Installation & Operation

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) REV: LN PN

!"#$%&'(&) !(*$%"'&!$() !"#$

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

Installation & Operation Instructions

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

BOTTLE COOLERS SLIDE TOP INSTALLATION AND OPERATION INSTRUCTION MANUAL MODEL SERIES BC24- BC36- BC48- BC72- BC96-

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Installation, Operation, and Maintenance Information

Hoshizaki America, Inc.

Installation & Operations Manual Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800)

Installation & Operations Manual. Master-Bilt Products 908 Highway 15 North New Albany, MS Phone: (800) /17 Rev.

Transcription:

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the Bill of Lading to ensure all crates and cartons have been received. Do not sign the freight bill clear until the freight has been properly inspected for damage. All units should be inspected for damage including concealed damage by uncrating immediately. If any damage is found, it should be reported to the carrier at once, noted on the Bill of Lading and a claim should be filed with the carrier. This equipment has been inspected and tested in the manufacturing facility and has been crated in accordance with transportation rules and guidelines. The manufacturer is not responsible for freight loss or damages. INSTALLATION CAUTION: This unit uses a flammable refrigerant. Use care when handling and operating to avoid damaging the refrigerant tubing or increasing the risk of a leak. The unit has been secured to the shipping base with four bolts. Remove these bolts and separate the unit from the shipping base. Locate the casters or legs found inside the unit. Attach the casters or legs to the unit base by screwing them into the threaded fittings that were used to secure the shipping base. Use the wrench provided to tighten the casters to the unit. The casters with the brakes should be installed on the front of the unit. For proper drainage of condensate, the unit should be level when placed in its permanent location. Leveling shims are included in the accessories package in the cabinet. Loosen the casters and insert shims between caster and bottom of the unit. Re-tighten the caster. The exterior of the cabinet and doors have been protected by a plastic covering. Peel this protective covering before installation. After removing the covering, clean the interior and exterior surfaces of the unit with soap and water and a rinse with clean water. Do not use chlorinated cleaners on the surfaces as they can cause corrosion. If the door(s) have come out of alignment during shipping, they will need to be adjusted. This can be accomplished by opening the door(s) and loosening the screws that hold both the top and bottom hinges to the cabinet. After adjusting the door so it is aligned correct, tighten the screws to securely hold the hinges and door(s) in place. The shelves and shelf clips are packaged inside the unit. Install the shelf clips on the pilasters inside the unit and set the shelves on the clips. The shelves are adjustable in 12.7mm (½inch) increments. The refrigeration system located at the bottom of the unit requires free air access for proper operation. Allow a minimum of 180mm (7 inches) between the back of the cabinet 1 3/19 Rev.G 146527

and the wall. Do not locate the unit next to heat generating equipment or in direct sunlight. Confirm that the proposed electrical outlet has the correct voltage, frequency and current carrying capacity for the requirements of the unit. This information is noted on the data plate on the inside left wall of the unit. The unit should be isolated on a circuit. Do not use an extension cord to get power to the unit. OPERATION Once the unit is connected to the proper power supply, the display panel will be lit for two (2) seconds followed by a beep, the cabinet temperature will be displayed and the compressor will start to run. The compressor is running whenever COMP is lit on the display. If the cabinet temperature is higher than +68 (+15 ) (refrigerator) or +14 (-5 )(freezer), the display will read <Hi>. If the cabinet temperature is lower than +14 (-2 ) (refrigerator) or -50 (-40 )(freezer), the display will read <Lo>. If the unit does not start immediately, check the power switch located on the bottom of the top grill. If the cabinet temperature is below +14 (-10 ) (freezer) or +50 (+10 ) (refrigerator) when the unit is plugged in, there will be a three minute delay before the compressor will start. The interior light will come on when a door is opened. The top doors activate the light on half-door cabinets only. Note: the light is always on in the Glass Door models. If you want to turn off the light, use the light switch on the top grill. Whenever a door is opened, the door open light on the display will be lit and the evaporator fans will stop. The fans will start three seconds after the door is closed. If a door is open for more than 30 seconds, the door open alarm will beep three times. If a door is open more than 60 seconds, the alarm beeps five times and if open more than five minutes, the alarm will beep continuously. On half-door cabinets only, the top doors activate this feature. The electronic control has an alarm function to remind the operator to periodically clean the condenser coil. The condenser coil will collect dust and debris during normal operation. If left unclean, this will lead to poor performance, high energy consumption and possible compressor failure. Warranties do not cover failures related to condenser cleaning. At 6-month intervals, the display will blink CL and the buzzer will sound to remind the operator to clean the condenser coil. After one hour, the buzzer will stop but the display will continue to blink CL. Refer to the MAINTENANCE section of this manual to learn how to clean the condenser coil. The electronic control can be reset to normal operation by pressing the Mode/Set and Verify buttons at the same time for five seconds. Depending on conditions, the condenser coil may require more frequent cleaning. When a door is closed on a cabinet that is running, an internal vacuum is created as the internal air is cooled and the door can be difficult to open for a while. These units incorporate a pressure relief valve that equalizes the vacuum to allow the door to be opened sooner. 2 3/19 Rev.G 146527

MAINTENANCE All service should be performed by factory authorized personnel. All component parts will be replaced with like components to minimize the risk of possible ignition due to incorrect parts or improper service. Cleaning Beginning with the initial installation, the interior surfaces of the cabinet should be periodically cleaned with a solution of warm water and baking soda. This solution will remove any odors from spillage that has occurred. The exterior of the cabinet should also be cleaned frequently with a commercial stainless steel cleaner, glass cleaner or mild soap solution. Do not use chlorinated cleaners on the stainless steel surfaces. Note: do not use stainless steel cleaner or other solvent-based chemicals on plastic parts (door handle or façade parts) as they could cause failure. Use mild soap and warm water on plastic parts. The door gaskets should be cleaned in place with a mild soap solution to extend their life. The shelving can be cleaned in a sink with a mild soap solution and a soft bristled brush. Condenser Coil Disconnect the unit from power prior to cleaning the condenser coil. Periodic cleaning of the condenser coil will aid the heat transfer of the refrigeration system and increase its efficiency. Cleaning is recommended a minimum of every 6 months. To accomplish this, remove the lower front grill from the cabinet. The condenser coil is located behind the grill. Use a soft bristled brush to remove any dirt particles that are on the fins of the condenser coil. Use a vacuum cleaner or compressed air to remove the loosened particles. Replace the lower front grill and reconnect the unit to power. Failure to clean the condenser coil can lead to performance loss and compressor failure. 3 3/19 Rev.G 146527

ELECTRONIC CONTROL 1. ELECTRONIC CONTROLLER DISPLAY PANEL LAYOUT 4 3/19 Rev.G 146527

Display St di th dt tb df SE Description Temperature Setting Mode Temperature Differential Setting Mode Cabinet Temperature Verification Mode Defrost Frequency Setting Mode Rapid Freeze Mode (Freezers Only) Forced Defrost Mode Temperature Unit Converter mode ( ) In converting Temperature Unit ( ), 1 (1 ) deviation can occur. ELECTRONIC CONTROL SETTINGS Setting Temperature- The temperature set point is adjustable from -22 (-30 ) to +8 (-10 ) for the freezers and +25 (+2 ) to +50 (+10 ) for refrigerators. The default set point is -5 (-20 ) for freezers, +36 (+4 ) for solid door refrigerators and +35 (+4 ) for glass door refrigerators. To set or adjust the cabinet temperature; Press Up or Down button until<st> is displayed. Press Mode/Set button to display current temperature set point. Press Up or Down buttons until desired set point is displayed. Press Mode/Set button to set the new value. Press Up or Down button until <th> is displayed. Press Verify button to return to display cabinet temperature. Setting Temperature Differential- The temperature differential is the amount of swing that the cabinet temperature does either side of the temperature set point. If the temperature set point is +36 (+4 ) and the temperature differential is +8 (+4 ), the compressor will start when the control shows +40 (+6 ) and stop when the control shows +32 (+2 ). The default temperature differential set point is +8 (+4 ) and the range is +4 (+2 ) to +16 (+10 ). To set the temperature differential; Press Up or Down button until <di> is displayed. Press Mode/Set button to see current temperature differential setting. Press Up or Down button until the desired value is displayed. Press Mode/Set button to set the value. Press Up or Down button until <th> is displayed. Press Verify button to return to display cabinet temperature. 5 03/15 Rev.G 146527

Rapid Freeze Mode (Freezers Only) When in rapid freeze mode the compressor will run continuously for 120 minutes and then return to normal operation and set points. To Start Rapid Freeze Mode; Press Up or Down button until <tb> is displayed. Press Mode/Set button for two seconds to start rapid freeze. To Stop Rapid Freeze; During rapid freeze, press Mode/Set button for two seconds. <tb> will flash five times and then return to normal operation. Setting Defrost Frequency- The unit is preset to defrost every 6 hours for freezers ; 12 hours for refrigerators. The defrost frequency can be set from 4 to 12 hours with a two hour interval. During defrost <df> is displayed instead of cabinet temperature. To set defrost frequency; Press Up or Down button until <dt> is displayed. Press Mode/Set button to see current defrost frequency setting. Press Up or Down button until desired value is displayed. Press Mode/Set button to set the value. Press Up or Down button until <th> is displayed. Press Verify button to return to display cabinet temperature. Setting Forced Defrost- To start a forced defrost; Press Up or Down button until <df> is displayed. Press Manual DF for 2 seconds to start a forced defrost. To stop a forced defrost; During a forced defrost, press Manual DF button for 2 seconds to stop a forced defrost. <df> will flash five times and then return to normal operation. Setting Temperature Unit Setting the temperature unit and temperature control is possible. ( ) To select the temperature unit Press Up or Down button until <SE> is displayed. Press Mode/Set button and the current temperature unit is flashing. Press Up or Down button and set the desired temperature unit. ( ) Press Mode/Set button to set the value. Press Up or Down button until <th> is displayed. Press Verify button to return to display cabinet temperature. 6 03/15 Rev.G 146527

TROUBLESHOOTING Problem Possible Cause Remedy Compressor will not start Power connection failure Power switch is in off position Check power cord and plug it in Move it to on position Temperature set point is too high Correct temperature set point The door is opened too frequently The unit does not refrigerate well Loading of too much warm or moist product Not enough ventilation Move the unit in a well ventilated place with at least 180mm (7 inches) of clearance on all sides Condenser is clogged Clean it Condensation on cabinet exterior High humidity air can result in condensation Wipe with cloth 7 03/15 Rev.G 146527

SPECIFICATIONS PRODUCT Solid Full/Half Door Freezer Solid Full/Half Door Refrigerator MODEL F23-S F49-S F72-S R23-S R49-S R72-S Capacity 650 l (23 ft 3 ) 1,385 l (49 ft 3 ) 2,035 l (72 ft 3 ) 650 l (23 ft 3 ) 1,385 l (49 ft 3 ) 2,035 l (72 ft 3 ) Exterior Dimensions (including Casters & Door handles) (W) 695 mm (27.4 ) 1,400 mm (55.2 ) 1,980 mm (78.0 ) 695 mm (27.4 ) 1,400 mm (55.2 ) (D) 838mm (33 ) 838mm (33 ) (H) 2,127 mm (83.7 ) 2,127 mm (83.7 ) 1,980 mm (78.0 ) Swing Doors 1 2 3 1 2 3 Shelves 4 8 12 4 8 12 Compressor 3/5HP 3/4HP 1HP 3/8HP 3/8HP 3/8HP Power Voltage 115V 115V 115V 115V Plug In-Installation NEMA 5-15P NEMA 14-20P NEMA 5-15P Amps 8.0 10.5 14.5 7.5 7.5 7.5 Range of Temperature Below -18 (0 F) 0 ~ 4 (+32 F ~ +40 F) R290 R290 Refrigerant 100g (3.5 oz) 130g (4.6 oz) 140g (4.9 oz) 70g (2.5 oz) 90g (3.2 oz) 120g (4.2 oz) Product Weight 124 kg (273 lb) 194 kg (428 lb) 255 kg (562 lb) 121 kg (267 lb) 186 kg (410 lb) 253 kg (558 lb) Above specifications are subjected to change without prior notice for quality improvement. 8 03/15 Rev.G 146527

SPECIFICATIONS PRODUCT Glass Door Refrigerator MODEL R23-G R49-G R72-G Capacity 650 l (23 ft 3 ) 1,385 l (49 ft 3 ) 2,035 l (72 ft 3 ) Exterior Dimensions (including Casters & Door Handles) (W) 695 mm (27.4 ) 1,400 mm (55.2 ) (D) 835 mm (32.9 ) (H) 2,127 mm (83.7 ) 1,980 mm (78.0 ) Swing Doors 1 2 3 Shelves 4 8 12 Compressor 3/8HP 3/8HP 3/8HP Power Voltage 115V Plug In-Installation NEMA 5-15P Amps 7.5 7.5 7.5 Range of Temperature 0 ~ 4 (+32 F ~ +40 F) R290 R290 Refrigerant 70g (2.5 oz) 90g (3.2 oz) 120g (4.2 oz) Product Weight 126 kg (278 lb) 200 kg (441 lb) 271 kg (597 lb) Above specifications are subjected to change without prior notice for quality improvement. 9 03/15 Rev.G 146527