Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Similar documents
Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

for relative humidity and temperature

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Relative Humidity Transmitters

Duct Temperature Sensors

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

OEM Alpha Thermostat direct Analog

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Product data sheet AIRWIN BO-FK-120J Humidity sensors

Products. World Edition

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

for relative humidity and temperature

TER Active Room Temperature Sensor (Controller),

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

SDR Dry Room. Outstanding performance

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Using the DewTrak II Dew Point/ Humidity Transmitter

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Gas Central with built-in Gas Detector for Nitrogen Dioxide (NO 2

Potential Applications

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Sensor unit MC2 with analog output for Freon gases and refrigerants

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Installation Manual. esense Duct (Disp) Figure 1 The esense Duct with and without display

Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Advantages / Characteristics

ST Wiring diagram. Product description. Standard temperature controller. Order number

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Hygro/hygrothermal transducers (hygrometric)

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Hygro/hygrothermal transducers (hygrometric)

Duct Air Quality Sensors

Duct Temperature Sensors

EasyLog Data Logger Series

Inductive. Range. S410/IND Electrodeless Conductivity Sensors

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Accessories, interfaces, sensors and complete solutions.

QPM21 Series Duct CO 2 and Air Quality Sensors

SUPPLY TO CENTRAL HEATING SYSTEM SUPPLY TO DHW TANK RETURN FROM CENTRAL HEATING SYSTEM RETURN FROM DHW TANK

Sensor Selection Guide. Sensing for Building Applications

Outside Air Humidity & Temperature Sensor

Sitron s CF Line of Flow Switch Monitors

EasyLog Data Logger Series

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Accessories, interfaces, sensors and complete solutions.

HVAC Sensors Catalogue

Using the Model 1500 Portable Chilled Mirror Hygrometer

HYGROPHIL H process hygrometer

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

Temperature Controllers

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

MELA Sensortechnik GmbH

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

MultiFix Central unit

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

HSD Dry Cabinet. Outstanding performance

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Constant climate chambers

DETECTORS, REMOTE CONTROLS & VARIOUS ACCESS.

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Heat Sensor Cable Alarm Units DT650L / DT950L

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

XSD Dry Cabinet

1. Product description

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

Room controllers with manual forced ventilation function

Hygrostats (hygrometric)

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Transcription:

Features Humidity and Temperature outputs in same unit With or without display Humidity output 0-10 Vdc or 4-20 ma Temperature output 0-10 Vdc or 4-20 ma As option passive direct temperature output PT1000, PT100, NTC, NI1000 etc Humidity tolerance ± 2% at 20 to 80% rh Temperature tolerance ± 0,5K Relative humidity measuring range 0 to 100% rh DIP switch on pcb to select: Relative Humidity, Absolute Humidity, Dew Point and Entalpy Absolute humidity measuring range 0 to 30g/ m3 Dew point measuring range -50 C to +100 C Entalpy 0 to 85 kj/kg Including duct mounting flange IP65 protection Ordering Type no. Humidity Temperature Display Passive Output Output Temp. Output 010 010 0-10 Vdc 0-10 Vdc No No 010 010 D 0-10 Vdc 0-10 Vdc Yes No 420 420 4-20 ma 4-20 ma No No 420 420 D 4-20 ma 4-20 ma Yes No 010 010 XXX 0-10 Vdc xxx (see below) No Yes 010 010 XXX D 0-10 Vdc xxx (see below) Yes Yes 420 420 XXX 4-20 ma xxx (see below) No Yes 420 420 XXX D 4-20 ma xxx (see below) Yes Yes XXX = Passive sensor PT100, PT100 1/3 DIN, PT1000, PT1000 1/3 DIN, NI1000, NI1000/TK5000, NTC 1.8K, NTC 5K, NTC 10K, NTC 20K, KTY81-210 Example: Humidity output 0-10 Vdc, Temperature Output 0-10 Vdc, PT1000 temperature direct sensor output and Display, type is : 010 PT1000 D

Technical data Humidity output: 0-10 Vdc or 4-20 ma Temperature output for active versions: 0-10 Vdc or 4-20 ma Temperature output passive sensor: Power supply with 0-10 Vdc output: Power supply with 4-20 ma output: Sensor element (humidity): Sensor element (temperature): Sensor element with passive temperature output: Humidity (relative) measuring range: Humidity (relative) tolerance Temperature operating: PT1000, PT100, NTC, NI1000 etc. 16-36 Vdc or 24 Vac 16-36 Vdc Capacitive sensor Capacitive sensor At customer's selection PT1000, PT100, NTC, NI1000 etc. 0 to 100% rh ± 2% at 20 to 80% rh -30 C to +70 C Temperature tolerance: ± 0,5K Load for analogue 0-10 Vdc output: Apparent ohmic resistance for analogue output: Operating temperature: Operating range: Response time for rh: Connection: 10 to100 kohm 300 to 1000 Ohm -30 C to +50 C 0 to 98% rh 8 Secs. (63% at condensation) Screw clamps 1,5 mm² Casing: Material ABS, Colour RAL 9010 Dimensions Housing (L x W x H): Probe lenght: Protection class: Absolut humidity measuring range: Dew point measuring range : Entalpy: 65 x 60 x 38 mm 220 mm IP65 0 to 30g/ m3-50 C to +100 C 0 to 85 kj/kg

Description The duct humidity and temperature sensor measures the humidity and temperature of air. The duct humidity and temperature sensor converts the measurements humidity and temperature into standard signals of 0-10 Vdc or 4-20 ma, temperature passive sensor PT1000, PT100, NTC, NI1000 also available as direct temperature output. The duct humidity and temperature sensor can be ordered with or without display. DIP switch on pcb to select relative humidity, absolute humidity or dew point measurement. The built-in display on room humidity and temperature sensor show actual humidity and actual temperature. Probe lenght for duct humidity and temperature sensor is 220 mm. Mounting flange is included in the scope of delivery for room humidity and temperature sensor. E-paper Display The display versions for duct humidity and temperature sensor is an E-Paper display that reflect light just as regular paper, therefore the display is a passive (non-luminating) display. Thin, light, flexible, good contrast, low energy consumption and no light reflections. Easy reading even with high insolation and ambient brightness. E-Paper displays only need energy when the display contents change. Optics and readability are significantly better than with monochrome LCD s or other bi-stable systems. High readability independent of the reader's perspective.

Electrical Connection Configuration Configuration

Dimensions We reserve the right to make changes in our products without any notice which may effect the accuracy of the information contained in this leaflet.