M100 LED Direct/Indirect

Similar documents
M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

M100 My White LED Direct Tunable White

M36 My White LED Direct

M60 LED Recessed Wet Location

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

LUX PENDANT DIRECT/INDIRECT

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

RECESSED T-Bar & Drywall

RECESSED - WITH StepLens OPTION

SURFACE Spec Guide. up to 105 lm/w performance

VESICA LINEAR SUSPENDED VES L

RECESSED Spec Guide. up to 111 lm/w performance

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

BAS SDL8' LED Strip Diffused Lens

Grüv Flare Regressed. Recessed Linear LED

SDL4 LED Strip Diffused Lens

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Grüv Flare Regressed. Recessed Linear LED

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Dimensions (111mm) (111mm) 3 (76mm)

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

l i g h t A B S O R B H

Fino. Asymmetric Wall Mount Indirect LED

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

LHBXD LED Linear High Bay

Linea 1.5. Linear Direct Wall Wash LED

FULL BLEED APPLICATION SHOT RENDERING

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

Alliance 4 - ALI4 LED 4 Linear High Bay

Fino Healthcare. Asymmetric Wall Mount Indirect LED

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Recessed LED Wall/Slot SAE 202

ArcLine Recessed LED luminaire

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Etch 2' x 2' Recessed LED

Project: Comments: Prepared By: Hardware Ordering Guide. Platform (see page 3 color chart) Wide Gamut. Tunable

Claude Indirect Wall WALL

Performance Chart Electrical Data

Performance Chart Electrical Data

lumenalpha downlight Specification Sheet

Performance Chart Electrical Data

Recessed. DuaLED 2x , 2700, 3000, 3400, 3800, or 4400lm

3.75 Gyro Shift Multiples Single Head

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

BAS SFP22 Edge-lit LED Panel

Project Name. Date. Cat. Number. Type

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

Essentials Series 4.0

CERRA 10 LED Design2Ship

DHL-LP-LED Low Profile LED Linear High/Low Bay

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

PRELIMINARY 2000K PERFORMANCE. CRI Lumen Maintenance Binning Tolerance Warranty

RLN Recessed LED luminaire

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

Hornet HP. Round Glass Downlight

BeveLED Cylinder LBRP6 Surface

DIMMING 0-10V Continuous

Classix 6" 6" Round Lens Wall Wash

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

FPLHB - Fidelux Premier Linear Highbay

CIRRUS CEILING WALL GRAZER WITH REMOTE POWER

Essentials Series 4.0

Performance Chart Electrical Data

NOVA CEILING WALL GRAZER WITH REMOTE POWER

Project Name. Date. Cat. Number. Type

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Lumen Output (3500K) Lumen Efficiency (3500K)

Metalux 4WSL / 8WSL LED

LIGHT CHANNEL TRIM 1.6

P ulse A new linear pendant from Prudential Ltg. that reshapes sinuous o rdinary spaces using the power of inspired design.

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Truss Surface SURFACE

GL BAL GLEDAL 150W B L A Z E AISL E L IGHT SPECIFICATION SHE ET OPTICAL SPECS ELECTRICAL SPECS CERTIFICATIONS OTHER DETAILS DIMENSIONS BEAM ANGLES

New Linear Series DISCONTINUED

Evoke Square Downlight

Evoke Square Downlight

SOLID STATE ILLUMINATED RAIL

LED HIGH BAY LINEAR ECO SERIES

LED FLAT PANEL EDGE LIT MLFP SERIES G2

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

800 TO 9000 LUMEN 8 LED RETRO-FIT HYPERBOLIC / PARABOLIC / WALLWASH LRT8 SERIES

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

Max 4 Flush Lens RECESSED

Product Specifications MaxLumen MRI LED Diffused Lighting

OLS-R-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL RECESSED LINEAR DIRECT SYSTEM 2" 4"

Transcription:

Date: Customer: Project: Type: Qty: Order Code: L1DI L1DI Series - - - - - - - - - - - - - - L1DI Direct Light Engine Indirect Light Engine 1B45 1,2,3 893lm/11.2W 1B45 1,2,3 893lm/11.2W 1B40 1,2,3 807lm/9.9W 1B40 1,2,3 807lm/9.9W 1B35 1,2 710lm/8.7W 1B35 1,2 710lm/8.7W 1B30 1,2 606lm/7.3W 1B30 1,2 606lm/7.3W 1B25 1,2 543lm/6.4W 1B25 1,2 543lm/6.4W 1B20 1,2 410lm/4.8W 1B20 1,2 410lm/4.8W 1 Values calculated from a 4 fixture @4000K using LW Shielding and DIM driver. For additional information please see page 2. 2 Mixed output available 4 and up, see page 7 for details. 3 Not available with Lutron. CCT 27 30 2700K 3000K 35 3500K 40 4000K Direct Shielding LW LED Optimized White lens MI Clear Lens with Microprism NB LMO Symmetric with Satine Lens A2 LMO Asymmetric 20 Wall Washer with Satine Lens A5 LMO Asymmetric 5 Wall Grazer with Satine Lens BW LMO Batwing with Satine Lens Indirect Shielding LW LED Optimized white lens Mounting C Cable S Swivel Stem RS Rigid Stem W Wall Mount Nominal Fixture Length 02 2 ft. 03 3 ft. 04 4 ft. 05 5 ft. 06 6 ft. 07 7 ft. 08 8 ft. 09 9 ft. 10 10 ft. 11 11 ft. 12 12 ft. Individual fixtures, Runs and Configurations are supplied in nominal lengths to ensure full, even, illumination. See pages 2 through 5 for additional details. XX Runs (over 12 ) are available in 1 nominal increments, round up to the nearest foot and replace the xx with the # (i.e. 13=13 nominal) Finish WH White Voltage 120 120 Volt Fixture Options DL 9 Damp Location Rated BK Black 277 277 Volt FS 9 In-Line Fuse SV Silver UNV 347 4 120 through 277 347 Volt 50/60hz capable (consult factory) DML 5,8 eldoled SOLOdrive 0-10V (Logarithmic) Driver DIM 5 DMD 5,8 0-10V (Linear) DM 5,8 eldoled SOLOdrive 0-10V (Linear) BL Semi-Matte Black SS 9 Separate Switching eldoled DALI (Logarithmic) SP Specify Premium Color DC2 5,6 Lutron 2-Wire DE1 5 Lutron Eco-System DC5 SR 5,7 Lutron 5-Series Philips (consult factory) Xitanium SR DALI Custom colors are available, Please consult factory 4 347V not available with EM internal battery option 5 See page 6 for full details 6 120V only 7 For use with E and P sensors only 8 EM option not available in 4 lengths 9 See page 7 for full details and restrictions Sensor Options xe 10,11 Enlighted xp1 10,11 Philips Daylight Replace x with quantity xp2 10,11 Philips Occ/Vac xp3 10,11 Philips Occ/Vac/ Daylight xs1 10,12 Sensor Switch Daylight xs2 10,12 Sensor Switch Occ/Vac xsn xs3 10,12 Sensor Switch nlight enabled Occ/Vac/ (consult factory) Daylight 10 Minimum length 2 See page 8 for full details and restrictions 11 For use with SR driver only 12 For use with DIM driver only Emergency Options Configuration Options EC 13,14 Emergency Circuit Wiring IL90 16 Lit Horizontal 90 Corner EMR 14 Remote Micro Inverter (consult factory) IT90 16 Lit T section EM 13,14,15 Integral EM Battery Pack (consult factory) IX90 16 Lit X section 13 See page 7 for full details and restrictions 14 For EM with sensors please consult factory 154 available with DIM driver only. 6 available with all driver options 16 See page 9 for full details and restrictions 5YEAR LED WARRANTY ARRA Compliant ADA Compliant Page 1 of 11 LED DI_v4.0

6 (152mm) LW lens shown for reference 3 11 /16 (94mm) 3 15 /16 (100mm) Construction: 35 C (95 F) for all drivers. Housing - Continuous, low copper 6063-T6 extruded aluminum profile with aluminum endcaps, available as Individual fixtures (up to 12 ) or Runs. Geartray - Low copper 6063-T6 extruded aluminum profile. Shielding - Extruded, impact resistant acrylic snap in lens: - LED Optimized White Lens (LW) - Clear Lens with Microprism (MI) LMO refers to the Selux proprietary LED optical system - Light modulation optics. These lenses are offered in behind a Satine Lens for even illumination and comfortable lit appearance. - LMO symmetric lens (NB) - LMO Asymmetric 20 wall washer (A2) - LMO Asymmetric 5 wall grazer (A5) - LMO Batwing (BW) Mounting(s)- 1/16 Aircraft Cable, Ø5/8 Swivel or Rigid Steel Stem, Wall Bracket, (see pages 3 through 5 for details). ** Cable, Stem and Wall mountings may not be symmetrical for Runs and Configurations due to the use of modular housing lengths. If symmetrical suspensions are required please consult the factory Standard Luminaire lengths - All standard luminaires are supplied in nominal lengths to ensure full, even, illumination. Runs and Configurations are available in approximately 1 increments starting at the nominal 12 fixture length. ** Individual luminaires are not joinable in the field Exact length luminaires - Individual luminaires, Runs, and Configuration are available in exact lengths to meet your project needs. Please consult factory with you requirements. ** Lens luminance may soften at the very ends of the straight sections for exact length luminaires L10 Joiner(s) - Runs and Configurations are supplied in multiple housing that are joined together in the field using the supplied L10 Joining System. This allows ease of installation and ensures a uniform appearance (see page 7 for detail). Weight: 4.3 lb.. Electrical/Performance: LED Light Engine - Brand-name mid-power LEDs create a high efficiency LED light engine able to provide a lumen maintenance of 96% at 25,000 hours and 93% at 60,000 hours at 25ºC per TM-21 reports. Reported L70 greater than 60,000 hours. Delivered Lumens - Due to LED manufacturer s tolerances the listed output has a ±5% tolerance. For outputs based on different shielding or CCT please see photometry section at the end. CCT - Available in 2700K, 3000K, 3500K and 4000K, tolerance within a 3-step MacAdam ellipse. CRl - Minimum 90. All Drivers - High efficiency, constant current, soft start, Electronic Class 2 with a PFC>0.90. For more detailed information on the available drivers please see page 6. Sensors - Selux offers a variety of integral sensor options. Sensors are placed on the direct side of the fixture, but can control the Indirect lighting. For details and specifications, please refer to page 8. Emergency - There are multiple emergency options available - emergency circuit, remote micro inverter, and integral battery pack. All options compliant with UL 924 listed emergency luminaire. Please consult factory for use of sensors with emergency options. For more details on EC and EM options, see page 7. Thermal Performance: Ambient Operating Temperature - Luminaires suitable for maximum ambient temperature of Luminaires are suitable for minimum ambient temperatures of: -40ºC (-40ºF) for DIM, DM, DML, and DMD drivers. -20ºC (-4ºF) for SR drivers. 0ºC (32ºF) for DC2 and DE1 drivers. Luminaire Finish: Powder Coat - All Selux luminaries are finished in high quality polyester powder coating in our Tiger Drylac certified facility and are tested in accordance with test specifications for coatings from ASTM and PCI. All products undergo a five stage intensive pretreatment process where product is thoroughly cleaned, phosphated, and sealed. Selux powder coated products provide excellent salt and humidity resistance as well as ultra violet resistance for color retention. Standard interior colors are White (WH), Black (BK), Semi-Matte Black (BL), and Silver (SV). Selux premium colors (SP) are available, please specify from your Selux color selection guide. Warranty: 5 Year Limited LED Luminaire Warranty - Selux offers a 5 Year Limited Warranty to the original purchaser that the series LED luminaire shall be free from defects in material and workmanship for up to five (5) years from date of shipment. This limited warranty covers the LED driver and LED light engine when installed according to Selux instructions and operated within the Ambient Temperature. For additional details and exclusions, see Selux Terms and Condition of Sale. Certifications and Compliance: NRTL - For Dry and Damp location (I.E. culus) ADA Compliant ARRA Compliant RoHS Compliant Page 2 of 11 LED DI_v4.0

Cable Mounting (C) Cable Mounting (C) 1. Ø1/16 Aircraft Cable with chrome gripper for easy adjustment (48 max. from ceiling to luminaire). Nominal Length A Housing Length Cable Mounting (C) - Dimensions * B (Ref.) End Suspensions C Mid. Suspension D Feed Location E Illuminated Length Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 02 (2 ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 7/8" 22 1' - 9" 534 03 (3 ft.) 3' - 5/16" 923 0' - 7/8" 22 2' - 10 5/8" 879 0' - 7/8" 22 2' - 7 5/8" 803 04 (4 ft.) 3' - 11 7/16" 1205 0' - 7/8" 22 3' - 9 11/16" 1161 0' - 7/8" 22 3' - 8 3/16" 1123 05 (5 ft.) 4' - 11 7/16" 1510 0' - 7/8" 22 4' - 9 11/16" 1466 0' - 7/8" 22 4' - 8 1/4" 1428 06 (6 ft.) 5' - 11 7/16" 1815 0' - 7/8" 22 5' - 9 11/16" 1770 0' - 7/8" 22 5' - 8 1/4" 1733 07 (7 ft.) 6' - 11 7/16" 2119 0' - 7/8" 22 6' - 9 11/16" 2075 0' - 7/8" 22 6' - 8 3/16" 2037 08 (8 ft.) 7' - 11 7/16" 2424 0' - 7/8" 22 7' - 9 11/16" 2380 0' - 7/8" 22 7' - 8 3/16" 2342 09 (9 ft.) 8' - 11 7/16" 2729 0' - 7/8" 22 8' - 9 11/16" 2685 0' - 7/8" 22 8' - 8 3/16" 2647 10 (10 ft.) 9' - 11 7/16" 3034 0' - 7/8" 22 9' - 9 11/16" 2990 0' - 7/8" 22 9' - 8 1/4" 2952 11 (11 ft.) 10' - 11 7/16" 3339 0' - 7/8" 22 10' - 9 11/16" 3294 0' - 7/8" 22 10' - 8 1/4" 3257 12 (12 ft.) 11' - 11 7/16" 3643 0' - 7/8" 22 11' - 9 11/16" 3599 0' - 7/8" 22 11' - 8 3/16" 3561 *Dimension(s) rounded to the nearest 1/16 with a ± 1/16 (1mm) tolerance. L1DI Cable (C) Suspension Detail (Feed location(s) only) L1DI Cable (C) Suspension Detail (Non-Feed location(s) only) Outlet box for feed only (by others) Cross bar with 1/4-20 rod and ground screw 2x Outlet box screws (by others) 1/4 x 5 diameter canopy (White) Cord strain relief bushing 1/4-20 Slip ring coupler Feed cord (White) 1/16 Aircraft cable 2x White cable stay Chrome gripper Luminaire 1/4-20 Threaded rod (supplied and installed in the field by others) 1/4 x 2 diameter canopy (White) 1/4-20 Slip ring coupler 1/16 Aircraft cable Chrome gripper Luminaire Page 3 of 11 LED DI_v4.0

Stem Mounting (S and RS) Swivel Stem (S) and Rigid Stem (RS) Mounting 1. Ø5/8 Swivel Stem provides 30 swivel and can be cut in field (48 max. from ceiling to luminaire). 2. Ø5/8 Rigid Stem is fixed and is not able to be cut/adjusted in field (48 max. from ceiling to luminaire). Nominal Length A Housing Length Swivel (S) and Rigid Stem (RS) Mountings - Dimensions * B (Ref.) End Suspensions C Mid. Suspension D Feed Location E Illuminated Length Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 02 (2 ft.) 2' - 1/4" 616 0' - 7/8" 22 1' - 10 1/2" 572 0' - 7/8" 22 1' - 9" 534 03 (3 ft.) 3' - 5/16" 923 0' - 7/8" 22 2' - 10 5/8" 879 0' - 7/8" 22 2' - 7 5/8" 803 04 (4 ft.) 3' - 11 7/16" 1205 0' - 7/8" 22 3' - 9 11/16" 1161 0' - 7/8" 22 3' - 8 3/16" 1123 05 (5 ft.) 4' - 11 7/16" 1510 0' - 7/8" 22 4' - 9 11/16" 1466 0' - 7/8" 22 4' - 8 1/4" 1428 06 (6 ft.) 5' - 11 7/16" 1815 0' - 7/8" 22 5' - 9 11/16" 1770 0' - 7/8" 22 5' - 8 1/4" 1733 07 (7 ft.) 6' - 11 7/16" 2119 0' - 7/8" 22 6' - 9 11/16" 2075 0' - 7/8" 22 6' - 8 3/16" 2037 08 (8 ft.) 7' - 11 7/16" 2424 0' - 7/8" 22 7' - 9 11/16" 2380 0' - 7/8" 22 7' - 8 3/16" 2342 09 (9 ft.) 8' - 11 7/16" 2729 0' - 7/8" 22 8' - 9 11/16" 2685 0' - 7/8" 22 8' - 8 3/16" 2647 10 (10 ft.) 9' - 11 7/16" 3034 0' - 7/8" 22 9' - 9 11/16" 2990 0' - 7/8" 22 9' - 8 1/4" 2952 11 (11 ft.) 10' - 11 7/16" 3339 0' - 7/8" 22 10' - 9 11/16" 3294 0' - 7/8" 22 10' - 8 1/4" 3257 12 (12 ft.) 11' - 11 7/16" 3643 0' - 7/8" 22 11' - 9 11/16" 3599 0' - 7/8" 22 11' - 8 3/16" 3561 *Dimension(s) rounded to the nearest 1/16 with a ± 1/16 (1mm) tolerance. L1DI Swivel Stem (S) Suspension Detail (feed wires through stem supplied by others) L1DI Rigid Stem (RS) Suspension Detail (feed wires through stem supplied by others) Outlet box (supplied and installed by others) 3/8 IP Crossbar with ground screws Cotter pin Hemispherical assembly 1 7/16 x 5 diameter canopy (white) 3/8 IP steel swivel stem (white) Dress nut Luminaire Square nut 3/8 IP nipple (supplied and installed by others) Outlet box (supplied and installed by others) Square nut Suspension hickey Square nut 1/4 x 5 diameter Canopy (white) Canopy securing screw 3/8 IP steel stem (white) Dress nut Luminaire Square nut Page 4 of 11 LED DI_v4.0

Wall Mounting (W) For patterns and configurations that are to include a wall mounted option, please see page 7for details. Nominal Length A Housing Length Wall (W) Mount - Dimensions * B (Ref.) End Suspensions C Mid. Suspension D Feed Location Feet/Inch MM Feet/Inch MM Feet/Inch MM Feet/Inch MM 02 (2 ft.) 2' - 1/4" 616 0' - 3 1/8" 79 1' - 6 1/16" 458 0' - 3 1/8" 79 03 (3 ft.) 3' - 5/16" 923 0' - 6 1/8" 156 2' - 1/8" 612 0' - 6 1/8" 156 04 (4 ft.) 3' - 11 7/16" 1205 0' - 6 1/8" 156 2' - 11 3/16" 894 0' - 6 1/8" 156 05 (5 ft.) 4' - 11 7/16" 1510 0' - 6 1/8" 156 3' - 11 3/16" 1199 0' - 6 1/8" 156 06 (6 ft.) 5' - 11 7/16" 1815 0' - 6 1/8" 156 4' - 11 3/16" 1504 0' - 6 1/8" 156 07 (7 ft.) 6' - 11 7/16" 2119 0' - 6 1/8" 156 5' - 11 3/16" 1808 0' - 6 1/8" 156 08 (8 ft.) 7' - 11 7/16" 2424 0' - 6 1/8" 156 6' - 11 3/16" 2113 0' - 6 1/8" 156 09 (9 ft.) 8' - 11 7/16" 2729 0' - 6 1/8" 156 7' - 11 3/16" 2418 0' - 6 1/8" 156 10 (10 ft.) 9' - 11 7/16" 3034 0' - 6 1/8" 156 8' - 11 3/16" 2723 0' - 6 1/8" 156 11 (11 ft.) 10' - 11 7/16" 3339 0' - 6 1/8" 156 9' - 11 3/16" 3028 0' - 6 1/8" 156 12 (12 ft.) 11' - 11 7/16" 3643 0' - 6 1/8" 156 10' - 11 3/16" 3332 0' - 6 1/8" 156 *Dimension(s) rounded to the nearest 1/16 with a ± 1/16 (1mm) tolerance. Wall Mount (W) (Covers a 4x4 or 2x4 J-Box) 4 (102mm) 1. Aluminum wall bracket (by Selux) 2. 4 x4 or 2 x4 J-Box at feed location (supplied and installed by others). 3. 1/4-20 Threaded rod, 1/4-20 lock washer and 1/4-20 nut required to anchor the wall bracket. Mounting hardware supplied and installed to code by others. 4 (102mm) 1 (25mm) 4 15 /16 (126mm) Page 5 of 11 LED DI_v4.0

Drivers: 0-10V linear dimming (DIM) Luminaires supplied with drivers offering the capability of either normal switched operation or 0-10V dimming for linear dimming curve. Fixtures ship wired for dimming. For on/off functionality, simply cap the dimming leads. Minimum dimming level preset at factory to 1%. (Due to size constraints, 1 luminaires are supplied with a driver from a different manufacturer than 2 and above luminaires. For details, please consult factory). eldoled SOLOdrive 0-10V linear dimming (DM) Luminaires supplied with SOLOdrive 0-10V dimming driver for linear dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. eldoled SOLOdrive 0-10V logarithmic dimming (DML) Luminaires supplied with SOLOdrive 0-10V dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. eldoled SOLOdrive DALI dimming (DMD) Luminaires supplied with SOLOdrive DALI dimming driver for logarithmic dimming curve. Minimum dimming level preset at factory to 1%. For dim to dark (down to 0.1%), please consult factory. * For control recommendations for eldoled drivers, please consult eldoled. LUTRON 2-wire dimming (DC2) Luminaires supplied with Hi-Lume 2-wire dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. LUTRON Ecosystem dimming (DE1) Luminaires supplied with Hi-Lume EcoSystem (4 wire, digital link) dimming driver programmed for Constant Current Reduction (CCR). For Pulse Width Modulation (PWM) dimming, please consult factory. Minimum dimming level down to 1%. * For control recommendations and system layout for Lutron drivers, please contact Lutron. Philips Xitanium Sensor Ready DALI dimming (SR) Luminaires supplied with Xitanium SR dimming driver programmed for Constant Current Reduction (CCR). Minimum dimming level down to 5%. For use with E and P sensors only. * For control recommendations and system layout for Philips drivers, please contact Philips. Driver Quantity 2 ft. 3 ft. 4 ft. 5 ft. 6 ft. 7 ft. 8 ft. 9 ft. 10 ft. 11 ft. 12 ft. RUN DIM 1 1 2 3 4 3 4 5 6 5 6 DM, DML and DMD drivers 1 1 2 2 2 3 4 4 4 5 6 Approximately 2 driver per 4 ft. Approximately 2 drivers per 4 ft. DC2 and DE1 drivers 1 2 2 3 4 4 4 5 6 6 6 Consult Factory *For SR driver counts, please consult factory *For inrush and control current, please refer to the driver manufacturers spec sheets. Wiring Diagrams Sensor Wiring Diagrams 0-10V linear (DIM) 0-10V linear eldoled SOLOdrive (DM) 0-10V logarithmic eldoled SOLOdrive (DML) DALI eldoled SOLOdrive (DMD) Philips SR DALI (SR) - The following wire(s) are in addition to the standard above - DIM, DM, DML, DMD & SR Gray = (-) DALI or 0-10V Dimming Control Purple = (+) DALI or 0-10V Dimming Control ENLIGHTED OR PHILIPS SENSOR DE1 Violet = E1 Digital Link Dimming Control Violet/White = E2 Digital Link Dimming Control SR (+) SR (-) PHILIPS XR DE1 SENSOR SWITCH ELDO 0-10V (+) (-) 0-10V AUX (+) AUX (-) Page 6 of 11 LED DI_v4.0

Fuse (FS) - Fusing, luminaires supplied with a in-line fuse located on the hot wire for each feed (supplied with an 8A slow burn fuse). Mixed Output - Luminaires have ability to offer mixed light engines (i.e. 1B35 direct and 1B25 indirect) starting at 4 and then in 2 steps (i.e. 6, 8, 10, 12...). Damp Location (DL) -Luminaires are suitable for use in damp location(s). Examples of such locations include protected areas under canopies, marquees, roofed porches, and similar locations where the fixture(s) are protected from direct contact with rain, snow, or excessive moisture (such as ocean spray). Interior locations include areas subject to moderate degrees of moisture, such as basements and certain barns and cold storage buildings. All solder points on LED boards are conformal coated. The phosphor layer of the LEDs is free of coating to avoid hazing. Separate Switching (SS) - Luminaire available with the Direct side switched separately from the Indirect side starting at the 4 nominal length and then in 2 nominal steps, i.e. 6, 8, 10, 12, etc. *For Damp Location with sensors, please consult factory. Emergency Circuit (EC) - Luminaires with EC option compliant to UL 924 listed emergency luminaire. EC luminaires are intended to be wired to separate panels/breakers for emergency use. - For 1 to 6 nominal luminaires, the entire fixture is wired for operation on emergency circuit. - For 7 and up nominal luminaires, the first 4 nominal length is wired for operation by a separate EM circuit by default to meet the required Life Safety Code (NFPA 101). *If a different configuration is needed please consult the factory. *For EC with sensors, please consult factory. Emergency Battery (EM) - Luminaires with EM option are provided with factory installed emergency battery. In the event of an emergency, EM battery will illuminate a nominal 4 section at 12W (constant) for 90 minutes (250C). Recharge time of 24 hours. If a different configuration is needed, please consult factory. The emergency battery pack is located integral to fixture and available in fixtures 6 with both direct and direct/indirect distributions and all driver options. Emergency option will illuminate the first nominal 4 section of fixture. For fixtures >12 or if a different configuration is needed, please consult factory. *Emergency battery option is UNV for use with 120/277V and is not available for 347V. *For EM with sensors, please consult factory. Joiner System - Standard for Runs and Configurations Fixture extrusion Joiner extrusion Recommended 5/32" Allen wrench Fixture extrusion Page 7 of 11 LED DI_v4.0

LED Direct / Indirect Sensor Ordering Chart Quantity Sensor Settings * x Number of Sensors E Enlighted FS-D22 P Philips Easy Sense SNS102 S Sensor Switch MSD EZ 1 Daylight 2 Occupancy/Vacancy 3 Daylight/Occupancy/Vacancy * Settings not available with Enlighted Enlighted FS-D22 (E) Occupancy/vacancy, daylight harvesting, plus the Internet of Things (IoT) data collection and reporting. For full details, please see FS-D22 spec sheet on the Enlighted website. Must be paired with Philips Xitanium SR driver (SR driver selection). Commissioning by Enlighted. *Please contact Enlighted for complete details prior to specifying. *Sensor can control up to 4 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Philips EasySense SNS102 (P) Occupancy/vacancy and daylight harvesting. Sensor can be programmed on-site via NFC or IR using Android app only, by others. For full details, please see the SNS102 spec sheet on the Philips website. Must be paired with Philips Xitanium SR driver (SR driver selection). Wall dimming via wireless wall switch from Philips/Illumra (www.illumra.com/easysense). **Please contact Philips for complete details prior to specifying. *Sensor can control up to 10 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Sensor Switch MSD EZ (S) Occupancy/vacancy and daylight harvesting. For full functionality and programming options, select settings option 3. If a different settings option is selected, other settings may be unavailable. For full details, please see MSD EZ spec sheets on the Sensor Switch website. Must be paired with eldoled 0-10V driver (DIM driver selection). Manual control of dimming not available with MSD EZ sensor. *Please contact Sensor Switch for complete details prior to specifying. *Sensor can control up to 30 drivers. Please refer to driver quantity chart on page 7. Multiple sensors may be required for longer lengths. Occupancy Vacancy Daylight Harvesting Driver Compatibility Enlighted FS-D22 (E) See Enlighted s website for full capabilities SR Philips EasySense SNS102 (P) SR Sensor Switch MSD EZ (S) DIM Factory Presets - Sensors come from the sensor manufacturer with factory presets for each of the settings in above chart. Please see sensor manufacturers spec sheets for details on presets and re-programming. Commissioning - Commissioning of sensors and installation by others. Contact sensor manufacturer for details and costs associated with commissioning the system prior to specification of sensors. Standard Sensor Placement - for other placement options, please consult factory. For functionality and limitations, please see sensor details above. Qty 1 Sensor - Beginning Qty 2 Sensor - Beginning and End (9 fixtures and longer) Fixture Length Lit Section* 3 (76mm) Qty 3+ Sensor - For spacing between sensors, please consult the sensor manufacturer 3 15 /16 (100mm) Beginning of Run Lens Aluminum Sensor Plate -to be painted same as fixture unless specified otherwise Notes: 1. For spacing between sensors, please consult the sensor manufacturer. 2. Exact sensor placement and coverage will be defined by approved factory drawing. 3. Sections controlled by sensors may not be symmetrical - consult factory for layout. * Lit section will be the fixture length minus 3 for sensor plate. Page 8 of 11 LED DI_v4.0

Standard Direct/Indirect shapes/configurations: Listed below are the minimum lengths and details for standard shapes. These standard shapes can be combined with each other and/or the standard luminaire lengths, ensuring full even illumination. If you have any questions, please consult the factory. The minimum standard lengths for L shapes: - IL90 or V90 open shapes is 4 x 4 nominal (example: leg, 90, leg) - IL90 or V90 closed shapes is 6 x 6 nominal (example: 90, leg, 90) (Exception is that the IL90 and V90 s can be joined directly to provide a 4 x 4 nominal shape) *For sensors in configurations, please consult factory For patterns and configurations that are to include a wall-mounted option, please consult factory to identify location, on which side of housing and spacing of brackets required. The minimum standard lengths for T and X shapes: - IT90 = 4 nominal on the short leg and 8 nominal on the long side - IX90 = 8 nominal for either direction Project Specific Direct/Indirect shapes/configurations: Selux is capable of supplying a wide range of project solutions including different shapes, angles, and sizes to meet the project requirements. Due to the complex nature of these project specific layout(s) we ask that you please consult the factory with the project requirements for review. Note: The indirect side of the cable and stem mounted configurations has small unlit sections for suspensions. For wall mounted configurations, the indirect side is fully lit. Direct/Indirect Lit Corner and Section - Dimensions IL90 IT90 IX90 Feet/Inch MM Feet/Inch MM Feet/Inch MM A Housing (Outside) 2' - 2 1/16" 662 A1 Housing (Inside) 1' - 10 1/8" 562 B Housing 2' - 2 1/16" 662 * B1 Ref. 2' - 1/8" 612 C Housing 4' - 3/16" 1224 * C1 Ref. 2' - 1/8" 612 D Housing 4' - 3/16" 1224 * D1 Ref. 2' - 1/8" 612 *Dimension(s) rounded to the nearest 1/16 with a ± 1/16 (1mm) tolerance. Page 9 of 11 LED DI_v4.0

Photometry LW Optics / 69W LED / 4000K CCT 1031 773 516 258 Catalog #: L1DI-1B35-1B35-40-LW-LW-X-04-XX-UNV Report #: 11685024.05 Delievered Lumens: 5677 Input Watts: 69.4848 Efficacy: 82 CCT: 4000K CRI: 95.7 2 1 Maximum Candela = 1031 Located At Horizontal Angle = 22.5, Vertical Angle = 1.5 # 1 - Vertical Plane Through Horizontal Angles (90-270) # 2 - Vertical Plane Through Horizontal Angles (0-180) MI Optics / 69W LED / 4000K CCT 2110 1583 1055 528 Catalog #: L1DI-1B35-1B35-40-MI-MI-X-04-XX-UNV Report #: 11800001.02 Delievered Lumens: 6342 Input Watts: 69.4865 Efficacy: 91 CCT: 4000K CRI: 95.7 1 2 Maximum Candela = 2110 Located At Horizontal Angle = 0, Vertical Angle =.5 # 1 - Vertical Plane Through Horizontal Angles (90-270) # 2 - Vertical Plane Through Horizontal Angles (0-180) Page 10 of 11 LED DI_v4.0

Photometry L100 LED Photometry Multiplier Table CCT Multiplier 4000K 1.000 3500K 0.972 3000K 0.963 2700K 0.931 CCT and CRI multipliers apply to the photometry, IES files, and values listed on page one (light engine). Light engine multiplier supplied for values listed on page one (light engine). Page 11 of 11 LED DI_v4.0