DASSAULT AVIATION Proprietary Data

Similar documents
DASSAULT AVIATION Proprietary Data

Canadair Regional Jet 100/200 - Water & Waste

DASSAULT AVIATION Proprietary Data

Bombardier Challenger Fire Protection

Fokker 50 - Fire Protection

DASSAULT AVIATION Proprietary Data

Dornier 328Jet - Lights

SECTION 2-07 FIRE PROTECTION

A AMM - TOILET SYSTEM - DESCRIPTION AND OPERATION

TOILET SYSTEM - DESCRIPTION AND OPERATION

SECTION 6-15 FIRE PROTECTION

TABLE OF CONTENTS FIRE PROTECTION. Page. 9-i

Section - III SYSTEMS DESCRIPTION

CIRRUS AIRPLANE MAINTENANCE MANUAL

Instrument and Control Panels

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION

DC3Training.com N28AA DC-3 Pilot s Handbook

Special Requirements For Health Care Facilities

CHAPTER 11 AIR CONDITIONING

Engine Fire Protection System

CHAPTER 11 HEATING AND VENTILATION

FIRE PROTECTION TABLE OF CONTENTS CHAPTER 9

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( )

Section - III SYSTEMS DESCRIPTION

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

Fokker 50 - Integrated Alerting Unit

Pressurization System

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

2011 Dassault Falcon 7X S/N: 107

Section - III SYSTEMS DESCRIPTION

2016 Plumbing Supplemental Plan Review List

WATER/WASTE SYSTEM - SERVICING

MINIMUM EQUIPMENT LIST ATA 33 - LIGHT F-27 Mk 050

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006

A380 Special Condition D 04 Crew Rest Compartment

PRE INSTALLATION PROCEDURES

Environmental Systems

182T and T182T Air Conditioning System ICA Revision: Date: 17 September, 2008

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

Electrofilm Manufacturing Company, LLC Repair Station Part Number Capability Iist

2007 Falcon 2000EX EASy

Canadair Regional Jet 100/200 - Lighting

Installation Manual CARBONATOR With Plain-Water Booster

INSTALLATION & SERVICE MANUAL

Installation & Operation

2001 CESSNA CITATION X

AIRCRAFT SALES & ACQUISTIONS GULFSTREAM G550

PART 135 CHARTER COMPANY, S/N

VIATION, LLC - MR. HARRISON LEFRAK

1994 Challenger 601-3R

2005 BOMBARDIER GLOBAL 5000 SERIAL NUMBER 9154 EQUUS GLOBAL AVIATION +1 (954)

Specialty Heated and Water Systems Components Catalog

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

HAWKER 800XP AND 850XP ILLUSTRATED PARTS CATALOG LOCATION FILAMENT/BULB VENDOR COCKPIT LIGHTING

2000 HAWKER 800XP SN

PRE INSTALLATION PROCEDURES

TROUBLESHOOTING VANGUARD

DESIGN STANDARDS SECTION PLUMBING FIXTURES AND EQUIPMENT. 1.3 Wall hung toilet room fixtures. Urinals for handicapped may be stall type.

AIRCRAFT SPECIFICATION

TUBS & SURROUNDS FIBERGLASS TUB STANDARD FIBERGLASS GARDEN TUB

HT V2 HT Split

Nexus FS Filtration Installation Guide. September 19, 2011

INSTALLATION & OPERATION MANUAL

PRE INSTALLATION PROCEDURES

FT60 Reduced Voltage - Autotransformer

Model Series Series

GRETEL II. FLYING DUTCHMAN BABA 30 Designed by Robert Perry US DOCUMENTATION NUMBER MEASUREMENTS

MATERIALS Traps TRAPS. No. IPC IRC Description

CIRRUS AIRPLANE MAINTENANCE MANUAL

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Mechanical Inspection Plumbing

2008 Gulfstream G550 S/N 5199, N443M (client will retain N#)

2011 GLOBAL 5000, S/N 9382

Isolux Arsenic Removal Systems Central Treatment Systems Operation and Maintenance Manual

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

WL380 QUICK START GUIDE

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

2006 Bombardier Global 5000 Serial Number: 9176 Registration: N720WS

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Read Only Document Not For Distribution

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Models Series Series

Simranjit Jakhar Wayne J Hilmer Jr HIGHLIGHTS:

2003 Gulfstream G550 Serial No. 5012

OPERATING AND INSTALLATION MANUAL

Operation. Operation. Hood-type High Temperature Dishwasher LISTED. Model: DH5000 Series

Models Series Series

OFFSHORE SUPPORT VESSELS 2014

5000 Series Bottled Water System by.

OPERATING AND INSTALLATION MANUAL

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

T0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29

Laundry hamper (most models) Wall mounted/framed TV cabinet (Columbus) Cherry hardwood dresser top (Columbus) Pillow top mattress

PLUMBING FIXTURES Reserved

FALCON 900EX EASy N988H S/N 125

2011 Falcon 2000LX. Aircraft Highlights. Jacksonville International Airport Jacksonville, Florida USA

Sun Bandit Hybrid Water Heater Installation and Operation Solar Hybrid Energy Systems Patent(s) Pending

FIRE EXTINGUISHING SYSTEM

APW PSI PRESSURE WASHER

Transcription:

F2000EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION Control 02-38-20 SYSTEM PROTECTION Introduction Circuit breakers Pressure Relieve Valves 02-38-25 ABNORMAL OPERATION CAS message

02-38-00 F2000EX EASY PAGE 2 / 2 CODDE 1 TABLE OF CONTENTS INTENTIONALLY LEFT BLANK

F2000EX EASY 02-38-05 CODDE 1 PAGE 1 / 6 GENERAL INTRODUCTION The F2000EX EASy is equipped with: - a pressurized water system to supply galley and toilet washbasin, - a chemical type front (option) and rear toilet unit with a flush and drain system. SOURCES EQUIPMENT POWER HP bleed air of engines or Tank pressurization APU bleed air or Air stored in specific accumulator (once the latter is charged) Cold water for: - RH front galley - Rear toilet washbasin Hot water Water heater Drain heat systems Pressurized water tank Pressurized water tank through toilet water heater LH (A4) bus RH (B2) bus

02-38-05 F2000EX EASY PAGE 2 / 6 CODDE 1 GENERAL EQUIPMENT LOCATION FIGURE 02-38-05-00 FRONT AND REAR DRAINING SYSTEM

F2000EX EASY 02-38-05 CODDE 1 PAGE 3 / 6 GENERAL FIGURE 02-38-05-01 POTABLE WATER SERVICE PANEL DOOR AND TANK

02-38-05 F2000EX EASY PAGE 4 / 6 CODDE 1 GENERAL FIGURE 02-38-05-02 TOILET SERVICE PANEL DOOR

F2000EX EASY 02-38-05 CODDE 1 PAGE 5 / 6 GENERAL Baggage compartment FIGURE 02-38-05-03 CABIN POWER SUPPLY BOX

02-38-05 F2000EX EASY PAGE 6 / 6 CODDE 1 GENERAL INTENTIONALLY LEFT BLANK

F2000EX EASY 02-38-10 CODDE 1 PAGE 1 / 4 DESCRIPTION GENERAL POTABLE PRESSURIZED WATER SYSTEM The pressurized water system supplies: - the RH front galley, - the rear toilet washbasin. The pressurized water system essentially includes a potable water tank that can be filled by gravity through a filling port located on the RH of the washbasin bowl, in the rear toilet or by pressure through a port inside potable water service door. Potable water tank capacity: 10 USG (38 liters). NOTE The water pressure of the external filling source must not exceed 60 psi (4 bar). NOTE To open gravity filling cap, press it before to depressurize the water tank. NOTE Water tank must be filled only with potable water (distilled and softened water prohibited). Water is distributed by tank pressure. Water system pressurization is ensured by pressurized air bled from the engines or from the APU, or in flight by air stored in one specific accumulator. Toilet water heater supplies hot water to the rear toilet washbasin. It provides 1.4 water liter at 52 C (125 F) approximately. It is load shed when GALLEY MASTER pushbutton is OFF. NOTE The water system can be drained to prevent damage by freezing in normal operating conditions, it is recommended to drain the tank to avoid contamination. For more information, see GROUND SERVICING (DGT681).

02-38-10 F2000EX EASY PAGE 2 / 4 CODDE 1 DESCRIPTION WASTE WATER Waste water is drained through water front and rear drain masts located under the fuselage. These masts and certain lines are electrically anti-ice. for more information, refer to ATA 30. CHEMICAL TOILET The chemical-type rear toilet unit features a drain pan with a drain valve and bowl equipped with a flush and drain system. Toilet waste water draining and toilet water tank filling can be performed through ports inside toilet service panel. Toilet has a fiberglass drain pan with a capacity of 14.3 USG ( 54 liters) included 2.5 USG (8.5 liters) for pre-loaded. FIGURE 02-38-10-00 REAR CHEMICAL TOILET

F2000EX EASY 02-38-10 CODDE 1 PAGE 3 / 4 DESCRIPTION FORWARD CREW LAVATORY (OPTION) A lavatory compartment is installed immediately in front of the main entry door. The compartment houses an electric-flush toilet serviced through an external panel on the forward lower RH fuselage. On the outboard side wall, a panel incorporates a fold-out sink with hot/cold water faucet. Waste water drains overboard through a heated drain mast system. The forward bulkhead contains a header incorporating a 220 V / 50 Hz power outlet, dual oxygen mask dropout box, a Public Ad system speaker and a RETURN TO SEAT sign. A ventilating system is installed in the compartment (2 fans under floor and 2 suction grids). FIGURE 02-38-10-01 FORWARD TOILET SERVICE PANEL DOOR (OPTIONAL) DOOR FWD TOILET not properly closed. CAS message appears when forward toilet service panel door is

02-38-10 F2000EX EASY PAGE 4 / 4 CODDE 1 DESCRIPTION INTENTIONALLY LEFT BLANK

F2000EX EASY 02-38-15 CODDE 1 PAGE 1 / 6 CONTROL AND INDICATION CONTROL DISTRIBUTION VALVES Located in front of the water tank in the toilet compartment, distribution valves allow to isolate or drain the different components of the water pressurized system. For more information refer to the GROUND SERVICING (DGT681) manual for use. Gravity filling cap FIGURE 02-38-15-00 DISTRIBUTION VALVES CONTROL FUNCTION Air valve Rear toilet distribution valve Drain valve Front galley distribution valve BP manometer To cut off the pressurized air supply to the potable water tank To isolate the rear washbasin from the fresh water supply system To drain the potable water tank To isolate the front galley from the fresh water supply system To Indicate air pressure in tank (normal: 20 psi)

02-38-15 F2000EX EASY PAGE 2 / 6 CODDE 1 CONTROL AND INDICATION GRAVITY FILLING CAP Red or green indicator Cap FIGURE 02-38-15-01 FILLING CAP CONTROL FUNCTION Cap Cap Red indicator Green indicator Press to depressurize the water tank Turn to move it Cap unlocked Cap locked

F2000EX EASY 02-38-15 CODDE 1 PAGE 3 / 6 CONTROL AND INDICATION WATER PRESSURE INDICATION The manometer(s) is(are) located: - on the rear toilet water tank, - in the forward galley (option). FIGURE 02-38-15-02 WATER TANK CONTROL AND INDICATION The pressure indicator located in RH bulkhead in baggage compartment indicates the accumulator water tank pressure. FIGURE 02-38-15-03 ACCUMULATOR WATER TANK PRESSURE

02-38-15 F2000EX EASY PAGE 4 / 6 CODDE 1 CONTROL AND INDICATION WATER HEATER TEST PANEL The water heater test panel is located in rear toilet, LH bulkhead. Test light Magnetic breaker Test switch FIGURE 02-38-15-04 WATER HEATER TEST PANEL CONTROL FUNCTION - It is used to test the water heating device Water heater test switch Water heater test light Water heater magnetic breaker - When set to TEST, the water heater test switch allows illumination of water heater test light if heating resistors are energized Illuminated if test switch in TEST position and heating resistors energized It is used to reset the water heater power supply unit after cut off due to failure detection

F2000EX EASY 02-38-15 CODDE 1 PAGE 5 / 6 CONTROL AND INDICATION POTABLE WATER SERVICE PANEL DOOR FIGURE 02-38-15-05 SERVICE PANEL DOOR CONTROL FUNCTION Control handle When the handle is pulled, the tank filling and venting lines open When the handle is pushed, the tank filling and venting lines close Water full light Indicates that the tank is full

02-38-15 F2000EX EASY PAGE 6 / 6 CODDE 1 CONTROL AND INDICATION TOILET SERVICE PANEL DOOR Cont rol handle Flushing port Draining port FIGURE 02-38-15-06 SERVICE PANEL DOOR CONTROL Drain valve control handle FUNCTION When the handle is pulled, the drain valve opens (connect the flushing tube before) Controls and functions are identical for the optional forward toilet service panel. FIGURE 02-38-15-07 TOILET PUSHBUTTONS

F2000EX EASY 02-38-20 CODDE 1 PAGE 1 / 2 SYSTEM PROTECTION INTRODUCTION The water system is protected by conventional trip-free circuit breakers located above the overhead panel and in the baggage compartment (cabin power supply box). CIRCUIT BREAKERS OVERHEAD PANEL FIGURE 02-38-20-00 DRAIN HEAT CIRCUIT BREAKER CABIN SUPPLY POWER BOX Water heater breaker FIGURE 02-38-20-01 WATER HEATER CIRCUIT BREAKER

02-38-20 F2000EX EASY PAGE 2 / 2 CODDE 1 SYSTEM PROTECTION PRESSURE RELIEVE VALVES The water supply system and the tank are protected against overpressure through pressure relief valves. The tank is also protected against negative pressure through a relief valve.

F2000EX EASY 02-38-25 CODDE 1 PAGE 1 / 2 ABNORMAL OPERATION CAS MESSAGE CAS MESSAGE DOOR FWD TOILET DEFINITION Forward toilet door is open (option).

02-38-25 F2000EX EASY PAGE 2 / 2 CODDE 1 ABNORMAL OPERATION INTENTIONALLY LEFT BLANK