BUILDER S PRE-INSPECTION CHECKLIST

Similar documents
BUILDER S PRE-INSPECTION CHECKLIST

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

Conversion to Vacation Home Permit Life Safety Survey

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Short-Term & Accessory Short-Term Rental Safety Certification

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Habitability Guidelines

Inspection Checklist Mechanical Final

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Rental Housing Inspection Guide

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

CHAPTER 7 ALTERATIONS LEVEL

Short Term Accommodations Fire Code Requirements

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Inspection Checklist Mechanical Rough in

Module number 8 provides an on-line, self-paced training seminar on portions of Chapter 14-Fuel Gas, Chapter 25-Ohio Plumbing Code; Chapter 29-Fire

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

Code verification sign-off

Building and Safety Division Civic Center Dr, Bellflower, CA, (562) x

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

An Owner s Guide to Maintaining a Mobile / Manufactured Home August 2010

El 0. El 0. El El. El El. El 0 TWO FAMILY HOUSING INSPECTINO CHECKLIST

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

HVAC Equipment Access Equipment Location

OFFICE USE ONL Y BELOW

2015 MECHANICAL CODE REQUIREMENTS

Montgomery County Land Bank PRE SALE INSPECTION REPORT

Maintaining Your Rental Property Part 2. An Overview of the Local Laws that Apply to Rental Properties. Please Sign In

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

City of Rehoboth Beach

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

2012 B.C. Building Code Compliance Review (Division B Part 3)

2009 ELECTRICAL CODE REQUIREMENTS

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Residential-based Care Facility R-4 Guideline

2012 INTERNATIONAL FUEL GAS CODE VENTS

DUCT SYSTEMS CHAPTER 6

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Life Safety - Means of Egress/Exits NFPA 101

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

CHAPTER 8 CHIMNEYS AND VENTS

Montgomery County Land Bank 130 West 2nd Street, Suite 1425 Dayton, OH PRE SALE INSPECTION REPORT

Rental Registration & Safety Inspection Program: Inspection Checklist

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

Denver Fire Department Fire Prevention Division

TABLE OF CONTENTS. Part I Administrative... 1

Tarrant County Community Development Division

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Residential Care Facilities Requirements

CHAPTER 8 CHIMNEYS AND VENTS

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

The Home Inspector Alaska LLC Donna Ranson Certified Inspector Cell:

For additional information regarding R-3.1 residential care facilities please contact (951)

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

I. STRUCTURAL SYSTEMS

CHIMNEYS AND VENTS CHAPTER 8

INTERIOR FINISH REVIEW

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Inspection Checklist Residential Mechanical Rough In July 2016

TABLE OF CONTENTS. Part I Administrative... 1

FIRE PREVENTION STANDARDS

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

Home Safety Checklist From Adaptive Remodeling Solutions, LLC Monona, WI

CHAPTER 15 PART IV NATIONAL ELECTRICAL CODE, 2017

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

Inspection Report 123 My Street Midland, GA

[NOTE: Proposed additions to existing code language are highlighted in yellow.]

Certificate of Inspection CHECKLIST

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

DUCT SYSTEMS CHAPTER 6

Fire and Life Safety Review Form

Code Compliance Report

Large Family Daycare Guideline

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

CMHC HOME MAINTENANCE CHECKLIST

Defend In Place 2012 IFC Overview of Institutional Occupancies

Agency for Health Care Administration

Inspecta-Homes 2469 University Avenue West St. Paul MN Ph#: (651)

Ventilation for New Low-Rise Residential Buildings July 20, 2015

Steve Ramsey Home Inspections

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

QUALITY FEATURES Trent 24 7 & ascot semi-detached

APPLICATION FOR Large Family Day Care Permit

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

IFGC-2012 AMENDED IFGC-2015 IFGC-2018 CHAPTER 1 SCOPE AND

Agency for Health Care Administration

Agency for Health Care Administration

Inside Out Home Inspections

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

Aging-In-Place Remodeling Checklist

Transcription:

Warrenton Fire Protection District 606 Fairgrounds Rd. Warrenton, MO 63383 Ph: 636-456-8935 Fax: 636-456-7764 www.warrenton-fire.org BUILDER S PRE-INSPECTION CHECKLIST This checklist is designed as a general guide to assist residential builders in preparing for a fire inspection. This checklist contains many common inspection items, however it is not allinclusive and does not contain all code requirements. Further, the code contains many exceptions and more detailed requirements than are described within this checklist. Nothing contained within this document shall be interpreted as code, law, ordinance, or directive. Warrenton Fire Protection District Ordinance 2018-001, and the 2015 International Residential and Fire Code should be referenced in any matter relating to code requirements. For further information, questions, or concerns you may contact the Warrenton Fire Protection District at 636-456-8935. PERMIT & INSPECTION GENERAL Fire Permit card is posted in the window and visible from the street. Building is clear of obstructions, waste, etc. that may obstruct views or access. Two Inspections are required, typically a rough framing and a final inspection, additional inspections may be required as deemed necessary by fire official. Contact our office for inspection details. To request an inspection call 636-456-8935 at least 24 hours prior to inspection, give your permit number, address and a contact number for inspection. Permit card and approved plans must be present at site for inspection. Anti-tip device is installed on stove. TEMPERED GLASS Tempered glass is installed in the following locations: Swinging and sliding doors and their assemblies, including sidelights. Enclosures for showers, bathtubs, hot tubs, etc. including glass in walls. Glass within 24 of either side of a door when closed and within 60 of the floor. Glazed area is > 9 sq. ft, < 18 above floor, > 36 above floor, within 36 of walking surface. Glass in railings and guards, regardless of height above walking surface. Glazing within 36 of stairways, landings, or ramps when within 60 of the walking surface. Glass within 60 of the bottom tread of a stairway in any direction and within 60 of the tread nose. - 1 -

GARAGE SEPARATION The following applies to a fire separation between garage and living space areas Doors must be 20 minute labeled fire-rated or solid wood core not less than 1 ¾ thick and must have a self closing device ½ Type X drywall separates the garage from the living space and attic area. 5/8 drywall separates garage from living area above the garage and structural supporting members. All ductwork in garage is covered with drywall and does not serve any garage area. Garage floor is non-combustible material and is sloped toward the vehicle entry doorway. EMERGENCY ESCAPE & RESCUE OPENINGS Emergency escape and rescue openings are typically windows, but can be doors as well, but must exit directly to the exterior. Minimum requirements are 5.7 sq. ft. net clear opening, min. 24 high opening, min. 20 wide opening, and max. 44 sill height. Basements with habitable space and every sleeping room shall have at least one emergency escape and rescue opening. The net clear opening requirements are obtained by normal operation from the inside. Operational from the inside without the use of keys or tools. Openings below the adjacent ground elevation are provided with a window well (add l requirements) MEANS OF EGRESS All hallways are not less than 36 wide. Main exit door is a side hinged door, min. 36 wide and 80 high, exiting directly to the exterior. Main exit door is readily openable from the inside without the use of keys, special knowledge, or effort. Stairways are not less than 36 wide above the handrail. Stairways are not less than 31.5 wide at and below the handrail, if only one is provided. Stairways are not less than 27 wide at and below the handrails, if two are provided. Handrails do not project more than 4.5 on either side of the stairway. Stairway headroom is a minimum of 6 8 throughout. Minimum tread depth is 9, measured nose to nose. Maximum riser height is 8 ¼ measured top of tread to top of tread. Maximum 3/8 difference between any two treads or risers. Minimum ¾ nosing on all treads, maximum 1 ¼. A landing is provided at the top and bottom of each stairway if the door swings over the stairs. Landings are min. 36 wide and 36 measured in the direction of travel. Handrails are provided on at least one side of a continuous run of stairs with 4 or more risers. Handrails are continuous from top to bottom of run (top riser to bottom riser). Handrails are 34 38 in height, measured from the top of the handrail to the tread nose plane. Handrails shall have a min. 1 ½ between the wall and the handrail. Handrail ends are returned to the wall, terminated into a newel post or safety terminal. Circular handrails: Min. 1 ¼ diameter, max. 2 diameter. Handrails not circular: Max cross section dimension of 2 ¼ and must be graspable. Stairways are provided with illumination which illuminates the treads and landings. - 2 -

GUARDS Guards on porches, balconies, raised floor areas, etc. more than 30 above floor or grade. Guards are min. 36 in height. Guards on open sides of stairs are a minimum of 34 in height. A 4 sphere cannot pass through guards, rails, balusters, etc. SMOKE ALARMS All smoke alarms are hardwired w/ battery back up and interconnected. Smoke alarms and installation are NFPA 72 compliant. At least one smoke alarm is located in: Each sleeping room. (not on AFCI circuits) In the immediate vicinity of each sleeping room. On every story or level. Enclosed mechanical rooms. Smoke alarms are a minimum of 36 from return air vents. Smoke alarms are located a minimum of 4 from any sidewall, regardless of angle. Coffered ceilings: Smoke alarms are installed on the highest portion of the ceiling. Vault ceilings: Smoke alarms are located within 12 36 of the peak. PREMISES IDENTIFICATION Street address is permanently affixed to structure. Arabic or block numerals are a min. 4 high and ½ stroke width. Numbers are high contrast to the background and not shiny, reflective, or polished. Address is plainly visible from the street on which the building fronts. If building is set back more than 75 from the street, additional address is within 35 of street. Street address does not contain script or spelled out numbers. FIREBLOCKING Concealed draft openings, concealed stud walls, partitions, furred walls, and parallel rows of studs are fireblocked at: Vertically at floor and ceiling levels. Horizontally at intervals not exceeding 10. Fireblocking is complete at interconnections between vertical and horizontal concealed spaces. (Soffits, drop ceilings, cove ceilings, etc.) Between stair stringers at the top and bottom of the run. All openings around vents, pipes, and ducts at ceiling and floor level with an approved material. Fireplace chimney or vent chases. (See Fireplace & Chimney section.) The integrity of all fireblocks are maintained and secured in place. All floor assemblies not using dimensional lumber or structural composite lumber equal to or greater than 2-inch by 10-inch nominal dimension shall be protected on the underside of the floor framing member - 3 -

APPROVED FIREBLOCKING MATERIALS: 1. 2 nominal lumber 2. ¾ plywood, particleboard, or OSB 3. 5/8 Type X drywall 4. 28 gauge galvanized steel or tin 5. UL listed fire caulk or other caulk approved by the Fire Code Official. FIREPLACES & CHIMNEYS SOLID FUEL BURNING (PRE-MANUFACTURED) Fireplace chases are protected from the living space with min. 5/8 Type X drywall. Chase drywall extends past the attic area to the roof sheathing. (Attic space separated from chase.) Chase must be vertically fireblocked at each floor/ceiling level. Minimum 2 clearance to combustibles is maintained from the chimney/flue. Appropriate clearance is maintained from the firebox, per manufacturers specifications. Fireplace and chimney are installed properly and per manufacturer specifications. Manufacturers instructions and operating guide remain with the fireplace until final inspection. GAS FIRED APPLIANCES Chase must be vertically fireblocked at each floor/ceiling level. Appropriate clearance is maintained from the firebox and flue/vent, per manufacturers specifications. Fireplace and chimney are installed properly and per manufacturer specifications. Manufacturers instructions and operating guide remain with the fireplace until final inspection. Gas shutoff, separate from the appliance, is located within 6 of the fireplace. CLOTHES DRYER EXHAUST DUCT Exhaust duct is independent of other systems and terminates on the outside of the building. Screens are not installed at the duct termination. Ducts are not connected with metal screws or other fastening means which extend into the duct. Joints run in the direction of air flow. Maximum duct length is 25. ( Reduce 2.5 for 45 degree angles and 5 for 90 degree angles.) RETURN AIR & PLENUMS Return air vents not located in closets, bathrooms, toilet rooms, kitchen, garage, or mechanical rooms. Return air ducts are isolated from other concealed spaces by approved fireblocking. Return air ducts do not communicate between floors. Material installed in return air ducts is non-combustible or plenum rated. Wiring passing through the duct perpendicular to the duct is fire caulked at each stud space. Wiring does not run parallel or with the return air duct. - 4 -

FUEL GAS Appliances are not located in sleeping rooms, bathrooms, toilet rooms, storage closets. Other than black steel pipe, must have yellow labels with black GAS letters every 5 feet. Each appliance has a shutoff valve separate from the appliance and within 6. Shutoff valves are not located in concealed spaces or return air ducts. Appliance vents are adequately supported. Horizontal exhaust vent runs are a minimum of ¼ rise for every 1 of length. Appliances have safety covers installed. Water heaters have a pressure/temperature relief device and discharge which extends within 6 of floor. ELECTRICAL ELECTRIC PANELS Electrical panel clearance: 30 width, 36 depth, 78 height. Piping, drains, etc. are not installed above panel. Illumination is provided in the area of the panel. No open knock outs; and penetrating wiring protected with grommets or other approved means. Each circuit is labeled to indicate purpose or use on the face or inside of the door. Panel is effectively grounded. WIRING METHODS Cable may not be attached to the bottom of joists it must be run through bored holes in the joist or on running boards. All cable is protected from physical damage. Floor boxes are specifically listed for the application. Receptacles are not installed within a bathtub or shower space. All splices and taps are contained within a junction box, receptacle box, or other approved method. All junction boxes, receptacles, switches, etc. are covered and protected with faceplates. GROUND FAULT, ARC FAULT CIRCUIT INTERRUPTERS AND TAMPER RESISTANT RECEPTACLES Receptacles are GFCI protected in the following locations: Bathrooms Garage and accessory buildings Outdoors Unfinished basements Kitchen (receptacles on all countertop surfaces) Bar Sink (receptacles serving the countertop surface within 6 of the outside sink edge.) AFCI protection is provided for all bedroom circuits. Smoke alarms are not on AFCI or GFCI circuits. Tamper resistant receptacles in all areas except, receptacles that are more than 5.5 above the floor, where they are part of a luminaire or appliance, or single receptacle for a single appliance or a duplex receptacle for two appliances where such receptacles are located in spaces dedicated for the appliances - 5 -

served and, under conditions of normal use, the appliances are not easily moved from one place to another. The appliances shall be cord-and-plug-connected to such receptacles. CLOTHES CLOSETS Closets contain only surface mounted or recessed light fixtures with no exposed bulbs/lamps. A minimum of 12 is maintained between any light fixture and the nearest point of storage. (Fluorescent light fixtures must be a min. of 6 from the nearest point of storage.) - 6 -