Afci TR Duplex 20A 125V La. Features amperage rating 20. Dimensions and Weight Width 3.3. Long Description

Similar documents
Afci TR Duplex 20A 125V Iv. Features amperage rating. Dimensions and Weight. Descriptions

AF/GF dual-purpose receptacles

Arrow Hart hospital grade self-test GFCI receptacles

Gfci Self Test Duplex 20A 125V WH

Arrow Hart specification grade GFCI receptacles

Specification Grade Straight Blade Receptacles. Quality solutions that provide reliable connectivity in all applications

Tamper & Weather Resistant Receptacles

Residential Occupancy & Vacancy Sensors

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Aspire LED, CFL & Incandescent Dimmer

SAL06PBK 300/600W 120V Dimmer. Features. Dimensions and Weight. Long Description

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Toggle AL series dimmer

Toggle AL series dimmer

Slide AL series dimmer

Introducing a revolutionary new line of 15 and 20 amp devices engineered for fast and easy installation

Recp Duplex 20A 125V 2P3W STR Swire WH

Smart AL series dimmers

Smart AL series dimmers

Decorator AL series dimmer

0ACDT2000MV Ultasonic/Infared Occ Sensor

3099-2E. Technical Information

Aspire smart AL dimmer

2014 NEC for. Understanding the. AFCI protection AFCI code compliant safety. Eaton is a registered trademark.

Switch Toggle DP 20A 120/277V Swire Iv

Recp HG Dup 20A 125V 2P3W STR B/Swire WH

MORE PROTECTION. MORE FUNCTIONALITY. IN MORE ENVIRONMENTS.

SECTION (16140) - WIRING DEVICES

AH8219HG Conn HG 15A 125V 2P3W STR BW

Receptacles. Wiring Devices Receptacles. Receptacle Families. Receptacle Colors. Standard Grade. Academy Series Outlets. Decorator Standard Grade

TAMPER & WEATHER RESISTANT RECEPTACLES

4SNLEDLD548SLUNV 4snledld548slunvl840cd1u

AFCI. RECEPTACLEFAQs. What is an arc fault? What causes arc faults?

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Rotary dimmer, single-pole

Gen Purpose Wiring Devices - Gen Purpose Switches

GE Industrial Solutions. Residential Electronic Circuit Interrupters

AUTOGUARD Hubbell Self Test Ground Fault Circuit Interrupters. More innovation. More protection. More safety.

Understanding Your Options: AFCI Protection and the 2015 CE Code

PART GENERAL 1.01 SECTION INCLUDES

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

2011 and 2014 National Electrical Code Changes Residential Only

PANELBOARDS & BUILDING DISTRIBUTION

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

Arc-Fault Circuit Interrupters (AFCIs) Frequently Asked Questions

Combination Type AFCI

Wallbox Lighting Controls Project Name:

LED Elite A19 Series 9W Non-Dimmable All-Purpose A19 A-Lamp 3000 K

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

TS 910/TS 920 AUTOMATIC TRANSFER SWITCHES OWNERS MANUAL

PANELBOARD PROTECTION ON A GLOBAL SCALE

Extra Heavy Duty Industrial & Hospital Grade GFCI Receptacles

How to keep you, your family, and your possessions safe usa.siemens.com/circuitbreakers

Introducing Hermaphroditic Blade and Receptacle Connector

Taxonomies, Classifications, and Categories NEMA RATED TURNLOK PLUGS, CONNECTORS, & RECEPTICLES Combo Telephone Tool

CIRCUITPRO Self Test Ground Fault Receptacles

Effective May 2017 Supersedes October 1998 (S )

The Safer Living Collection

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

Type MTS Miniature Test Switches

Engineered Solutions SYSTEMS CUSTOM ENGINEERED TO YOUR SPECIFICATIONS. Fused Coordination Panelboards...ES 2. Fusible Shunt Trip Switch..

Installation Instructions

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Entry Level Assessment Blueprint Electrical Construction Technology

SECTION POWER SUPPLIES AND DISTRIBUTION

Residual Current Devices

whole house safety Pocket Guide to Whole House Safety Siemens Energy & Automation, Inc Old Milton Parkway Alpharetta, GA 30005

Communications Point Data Base for Communications Protocol IEC

The most complete line of proven safety solutions.

* Consult factory on conditions for approval acceptability

A. This Section provides requirements and specifications for wiring devices, wiring device accessories, and wiring device assemblies including:

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

LED14DR5627K 14W Led 5"/6" Rec DWNLT 27K

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

PowerWave 2 Busway System

RZI06, RZE06, RZI10, RZM10

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Pocket Guide usa.siemens.com/afci

Overload relays. General descriptions. Configuration of the front

WHITE PAPER: ARC FAULT CIRCUIT INTERRUPTERS EXPANDING HOME SAFETY

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Two Circuit Heavy Duty Burner Connector

Advances in Load Center Technologies and End-of-Life GFCI Breaker Limitations

Power Blocks - Splicer/Distribution

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Retractable Work Surface Receptacle. Concealed Receptacle Provides Safe and Convenient Desktop Power

Wallbox Lighting Controls Project Name:

CHAPTER 20 SERVICE EQUIPMENT

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Guide Specification Model CTG Automatic Transfer Switch

OPTOTRONIC Power Supply OT96W/24V/UNV/DIM

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

A HOMEOWNERS HANDBOOK

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 TRAFCI20LA Afci TR Duplex 20A 125V La Eaton Wiring Devices Catalog Number Manufacturer Weight per unit Product Category TRAFCI20LA Eaton Wiring Devices Afci TR Duplex 20A 125V La 0.3700 (lbs/each) Gen Purpose Recept & Surge Pro Features amperage rating 20 connection Grounding Material Out branch circuit AFCI Receptacle Poles 2 Pole/ 3 Wire Voltage Rating 120 Dimensions and Weight Width 3.3 s Long Product Type Special Features Manufacturer Information Brand COOPER WIRING DEVICES GTIN 00032664739514 Manufacturers Part Number TRAFCI20LA sub brand ASPIRE UPC 032664739514 Taxonomies, Classifications, and Categories Category Commercial recepticals Type Duplex,AFCI, Tamper Reisitant Packaging Carton 1 Package 10 Weight Per each 0.37 Uses, Certifications, and Standards Application Enclosure standard 20A TR LA AFCI REC AFCI TR Duplex 20A 125V LA Afci TR Duplex 20A 125V La Tamper Resistant,AFCI,Lock Out Receptacle,NEC Requirements COMMERCIAL Tamper Reisitant NEC Requiremants UL

OBC Arc Fault Circuit Interrupter (AFCI) Receptacles 2-Pole, 3-Wire Grounding 15A, 125V/AC 20A, 125V/AC TRAFCI15 Design features Protects against arc faults in wiring resulting from damaged insulation and other causes that can lead to electrical fires Outlet Branch Circuit (OBC) AFCI receptacles protect from series and parallel arcs downstream Outlet Branch Circuit (OBC) AFCI receptacles also provide protection from upstream series arcs (no AFCI receptacle from any manufacturer can protect from upstream parallel arcs) Tamper resistant products comply with 2014 NEC Article 406.12 for all dwelling units Meets and exceeds Short Circuit Testing and Underwriters Laboratories UL 1699A and UL 498 Safety standards Ground termination with backwire clamp provides secure wiring and reduces installation time Line side terminals are backed out and staked for fast installation When downstream receptacles are wired from load side, a 20 amp feed-through rating offers full protection Tri-combo head terminal and mounting screws TRAFCI20V Table 1. Isolated Ground, Back & Side Wire Amps Volts Color Suffix TRAFCI15 Tamper Resistant OBC AFCI Receptacle TRAFCI20 Tamper Resistant OBC AFCI Receptacle 15 125 A, B, BK, GY, LA, V, W 20 125 A, B, BK, GY, LA, V, W

Applications Eaton s Wiring Devices Outlet Branch Circuit (OBC) AFCI receptacles provide protection against unseen arc faults that can result in electrical fires. With a 20A feed-through rating, arc fault protection extends to all down-stream devices and electrical cords when installed properly. Tamper Resistant shutters provide compliance with 2014 NEC Article 406.12 that states that all receptacles installed in dwelling units must be tamper resistant. TR designation provides visual identification. Terminal screws are backed out and ready to wire. Durable impact-resistant thermoplastic face and back body are virtually unbreakable. Table 2. Specifications Device Type Wiring Type Testing & Code Compliance Warranty Environmental Specifications Electrical Specifications Mechanical Specifications Table 3. Materials Top Housing Bottom Housing Strap Line Contacts Ground Contact Terminal Screws Ground Screw TRAFCI15 & TRAFCI20 Series Outlet Branch Circuit Arc Fault Circuit Interrupter Back & side wire culus Listed to UL1699A and UL498, File no. E341748 Meets all UL 1699A (AFCI) and UL498 (Receptacles) requirements and culus to CEC part II and CSA C22.2 No. 0 and C22.2, No.42 2-Year, Limited Flammability: Meets UL94 requirements; V2 rated Temperature Rating: -35 C to 66 C (-31 F to 150.8 F) Operating Areas: Indoor use Relative Humidity: 98% RH; non-condensing Dielectric Voltage: Withstands 2000V per UL498 Current Interrupting: Yes, at full-rated current Temperature Rise: Max. 30 C (86 F) after 100 cycles of overload @ 150% of rated current (DC) Trip Time: >110ms @ Series Arcs above 30A Frequency: 60 Hz; Voltage: 125V; Amperage: 15A/20A 20A Feed Through Short Circuit Testing: Meets and exceeds 10 ka Max. Interrupt Capacity: 20A Terminal Accommodation: #14 - #10 AWG Voltage Ratings: Permanently marked on device TRAFCI15 & TRAFCI20 Series Nylon PVC Steel Brass Brass #8-32 steel, brass plated; neutral screw nickel plated #8-32 steel, zinc plated, green Table 4. Color Ordering Information For ordering devices, include Cat. No. followed by the color code: A (Almond), B (Brown), BK (Black), GY (Gray) LA (Light Almond), V (Ivory), W (White) A B BK GY LA V W Almond Brown Black Gray Lt. Almond Ivory White 2 EATON www.eaton.com/arrowhart

Product Dimensions 1.30" (33.01mm) 1.00" (25.4mm) 1.30" (33.0mm) 1.00" (25.4mm) 3.28" (83.30mm) 3.78" (96.00mm) 4.20" (106.60mm) 3.28" (83.3mm) 3.78" (96.0mm) 4.20" (106.6mm) 1.26" (32.00mm) 1.26" (32.0mm) Figure 1. TRAFCI20 Figure 2. TRAFCI15 Wiring Diagrams Figure 3. OBC AFCI: Feed-Through Installation with Protection Provided Downstream Figure 4. OBC AFCI: Feed-Through Installation with Both Protected and Non-Protected Receptacles Downstream EATON www.eaton.com/arrowhart 3

Figure 5. OBC AFCI: Feed-Through Installation with Non-Protected Receptacles Downstream Certifications & Compliances TRAFCI15 TRAFCI20 KEY: culus 203 Cooper Circle Peachtree City, GA 30269 United States Eaton.com Canada Operations 5925 McLaughlin Road Mississauga, Ontario, L5R 1B8 Canada EatonCanada.ca Mexico Operations Carr. Tlalnepantla - Cuautitlan Km 17.8 s/n Col. Villa Jardin esq. Cerrada 8 de Mayo Cuautitlan, Mexico CP 54800 Mexico Eaton.mx Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2016 Eaton All Rights Reserved Printed in USA Publication No. TD610029EN May 2016 Eaton is a registered trademark. All other trademarks are property of their respective owners.