Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods th July 2012

Similar documents
I.F.U Re/Processing Reusable Medical Devices

Christina Bradley Laboratory Manager Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

المملكة العربية السعودية وزارة الصحة اإلدارة العامة لمكافحة عدوى المنشئات الصحية

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

THE BASICS OF DECONTAMINATION

Classification of Instruments -

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

SUGGESTED POLICY FOR THE MONITORING AN ULTRASONIC CLEANER DAILY

EVALUATION REPORT DISPOCLEAN ENDOSCOPE CLEANING BLADE. ALKAPHARM UK Ltd

THE ULTRASONIC DISRUPTION OF ORGANIC SOIL ON COMPLEX INSTRUMENTATION

REUSABLE ENDOSCOPY INSTRUMENTS (thermo resistant)

Innova new M2 and M3 series

Elaborating of a Reprocessing Instruction According to ISO Klaus Roth

For the ultimate in flexibility and cleanliness. Container and trolley washers for hospitals and CSSD units

ENDOSCOPE DECONTAMINATION : Where are we now!

Qualification of Washer/Disinfectors. Dr. Winfried Michels

Fiona Collins Liliana Donatelli Andrew Smith

Processing (cleaning, disinfection and sterilization) of instruments from Smith & Nephew Orthopaedics AG

Cleaning and Sterilization for Instruments & Posts

WORLD LEADERS IN ADVANCED SURGICAL INSTRUMENT REPROCESSING TECHNOLOGY

From a Catalogue of measures to a Standard Operating Procedure Example: Reprocessing of flexible endoscopes

Processing instructions for the Ligamys suture forceps

CLEANING INSTRUCTIONS

Cleaning & Sterilization

Washer-Disinfectors - Effectiveness and Quality Assurance. T. Miorini Institute for Applied Hygiene / ÖGSV

2015 Myco Industries, Inc Fax:

Getinge 9100E Cart Washer-Disinfector. Your safe, efficient and sustainable cleaning solution

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

INSTRUCTIONS FOR USE & STERILIZATION FOR INSTRUMENTS

GETINGE CLEAN DETERGENT RANGE GET MAXIMUM PERFORMANCE VALIDATED

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Instructions for Use Spinal Punches IFU

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

Aesculap Implant Systems

When you sterilize an instrument set, you know what the standards are.

O-PEP Hygiene-Beileger

Accessories. Maybachstraße. Symmetry Fax: Revised 10/15

CONVENTUS CAGE TM - DR Procedure Instruments Instrument Tray. Equipment Cleaning and Sterilization

The Principles, The Process, and The Results:

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Cleaning and Sterilisation for Burs, accessories and filling material

CLEANING AND HANDLING OF WRIGHT INSTRUMENTS

CORRECT ENDOSCOPE REPROCESSING

Getinge WD14 Tablo Tabletop washer-disinfector

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

CLEANING OF INSTRUMENTS

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

STERITITE INSTRUCTIONS FOR USE

AMSCO Washer/ Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare.

AMSCO Washer-Disinfectors. Central Sterile Services DISCOVER POWERFUL WASHING WITH INCREASED EFFICIENCIES. One Integrated Approach to Healthcare

CONVENTUS CAGE TM PH Procedure Instruments Instrument Tray Cleaning and Sterilization

WORK IN THE DISINFECTION ROOM WITH WASHER-DISINFECTORS

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

Aesculap Implant Systems

Integra Salto Talaris and Integra XT Non-Sterile Device Reprocessing. Instructions for Use. 4. Manual Cleaning Instructions

X99 Series. Dental Handpiece. Instruction For Use

Data of 57 hospitals** Estimated for England and Wales

Institute of Decontamination Sciences Blackburn House, Redhouse Road, Seafield, Bathgate, West Lothian EH47 7AQ

PICNet CONFERENCE 2013

Technical Data Monograph. Reliance Vision Single Chamber Washer/Disinfector

Operating / User Manual

Washer disinfectors Small - Medium range

An evaluation of washer-disinfectors (WD) and dishwashers (DW) effectiveness in terms of processing dental instruments

IMPORTANT INFORMATION ON THE DEPUY SYNTHES

Precision Ultrasonic Cleaning Equipment Buyers Guide

RECOMMENDATIONS FOR CLEANING DEVICES

Recommendations for cleaning, decontamination and sterilisation. devices

Technical Data Monograph. AMSCO 3052 Single-Chamber Washer/Disinfector AMSCO 5052 Single-Chamber Washer/Disinfector

SterilContainer S for use in the Steris V-PRO 60 Low Temperature Sterilization System

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Getinge WD14 Tablo Tabletop washer-disinfector. Fast and with high-throughput

Rigid Reusable & Single use Sigmoidoscopes, Anoscopes, and Accessories ENGLISH 1. Perform reprocessing immediately after each use.

Technical Data Monograph. Prolystica HP Enzymatic Automated Detergent Instrument Protection Properties (North America)

Wet Loads presentation Tim Galekop Abstract 2006

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC Tips and Files

Ultrasonic From delicate microsurgery instruments to heavy duty sets

Instructions for care, maintenance, cleaning and sterilization of Smith & Nephew orthopaedic devices

Does your equipment meet your needs and the operational capacity stated by the manufacturer?

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

RAP-hip Hip stem extraction set

SteelcoSure Independent performance verification of your equipment and processes

AS Medizintechnik GmbH Sattlerstraße Tuttlingen Germany

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Operating instructions Washer-disinfector G 7824

STERIS Instrument Cleaning Chemistries

Aim. Learning outcomes. 13 May Megan Reilly RN BN Cert IV Assessment & Workplace Training MHlthSc (Inf Control) Immunise Cert MACN CICP 1

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

Operator s Guide. Autoclavable Internal Handles with Integrated Paddles Rev. M

Manual Pre-disinfection/Cleaning and Sterilization Instructions for SATELEC wrenches

Getinge WD15 Claro Washer-disinfector

Accurately With HSE COP PT 1 5

HTM made easy. Testing Explained... in fact everything you need to know about HTM but were too afraid to ask!

Pharmaceutical washing-systems

Processing Instructions. Cleaning so easy.

Transcription:

Manual Cleaning? SOBECC Round Table: Manual and Automated Cleaning Methods 11.40-12.30 27 th July 2012 Chirurgie-Instrumenten-Arbeitsgruppe Berlin Dr. med. Dipl.-Ing. Thomas W. Fengler

What is so manual about Cleaning? 1. Medical devices enable new surgical approaches 2. Remanents are a fact after cleaning 3. (Re-)Processing cycle is a quality cycle 4. We move manually from step to step through processing 5. Cleaning needs specific tools and considerable skills 6. Washing is not Cleaning/ is not automatically happening 7. Process of cleaning has to be documented 8. Countable events have to be identified, verified and validated together with not countable events. 9. Validation is a spot check 10.Operator is responsible in the first place

Environment and Hygiene in the Operating Theatre: The Medical Device is just a part of it!

Safe Function and adequate Usability

Adequate and intended Use Visual and tactile examination

Verification and Validation of the safe Function which includes Cleanliness and Cleanability

Defining Parameters for Cleanliness

6 Hospitals, 6 (Re-)Processing Departments, 6 different Instrument Designs 7 Samples each* *Fengler TW, Pahlke H, Bisson S, Michels W: Are processed Surgical Instruments Free of Protein? ZentrSteril 2001; 9(1):20-32 4 analytical Methods: visual, modified Biuret, OPA for Protein Contamination, Pseudoperoxidase Reaction for Detection of Hemoglobin

Why (oh so ) correct (Re-)Processing? The risks of reprocessing are considered to be fully manageable. Correctness is the basic requirement in order to rule out at least one source of infection! Incidence of nosocomial infections remains unclear, since they are difficult to trace back. They might concern patients, resulting possibly in fatalities; some of which (allegedly: 20-30%) could be prevented. The hygiene- and sterilisation risk has to be kept to the inevitable residual risk, according to the state of science and technology. (from a verdict of German Federal Supreme Court [BGH]) From a legal point of view, work in a CSSD is a task of a higher degree. This implies an obligation for the staff, to be guided by the current state of science and technology at all times and further their education to the limits of what can reasonably be expected (quotations from relevant verdicts). 9

A Quality Cycle? What does (Re-)Processing of Medical Devices imply: sterilize clean & disinfect dry inspect waste waste use traceability stock wrap & label raw material sterilize

Do we know their qualification? Do we care?

Parameters of cleaning Chemical Temperature Water Mechanics Time

Manual cleaning may waste water (rinsing from the tap) and needs more time by cleaning one part after the other

Flexible Bone Drills

Washer disinfectors may reduce the waste of water rinsing many instruments at the same time in the same process Important parameters are Water pressure Volume of water Coverage of water Rotation Temperature Selected detergent Quality and quantity of operating means Velocidad Chosen load carriers Positioning of the chosen load

Water is moving the easiest way possible

Washer disinfector Washer disinfector can rinse inner lumina of medical devices with a defined pressure

Beware of the load! Charge it correctly! CEN ISO 15 883 Part 1-7

Cleaning is more than washing

Invalidable? The often-advanced argument that manual procedures cannot be validated must be dismissed, because automated procedures require manual steps as well. From a statement of German Society for Hospital Hygiene (Deutsche Gesellschaft für Krankenhaushygiene - DGKH), Dec. 2010.

Manual Reprocessing: Pros Manual tasks have always been and will always be part of the reprocessing cycle; we could not completely automate the whole cycle even if we tried. For instance in the reprocessing of endoscopes manual precleaning is required and considered to be state of science and technology. Manual cleaning may also be neccessary after automated processes, in case of persistant soil Use of Ultrasound-Baths is also considered a manual procedure Manual procedures are always and everywhere available a low-priced alternative to investments in machines allow for specific, intensive cleaning are best combined with automated processes

Manual Procedures Manual Reprocessing: Cons more disturbance variables (the human factor) difficult to validate or even reproduce identically (speed of work, pressure of brushing, amount of water in rinsing etc.) higher consumption of water and man-hours higher risk of injuries (fault of concentration, poor performance, lack of discipline, stress and hurry)

Be in touch, beware of penetration: Manual steps may be infectious Risk-reduction: wear Personal Protective Equipment (PPE) sharp and pointy instruments (needles, scalpels etc.) should be carefully removed from the trays before handling (preferably in the operating theatre) devices and materials that are not designated for reprocessing (single use devices, gauze pads etc.) should not go in the trays

Personal Protective Equipment (PPE)

Manual Cleaning: If you do it, do it right! Sticking to the correct order of process steps is very important: use the same order as in automated reprocessing! Use Standard Operating Procedures (SOP)! Validation is very difficult for manual procedures; SOP are the next best thing in order to attain reproducible results. the International Conference on Harmonisation (ICH) defines SOPs as detailed, written instructions to achieve uniformity of the performance of a specific function. The international quality standard ISO 9001 requires the determination of processes (documented as SOP) used in any manufacturing process that could affect the quality of the product (in this case: clean/sterile medical devices). SOP provide employees with a reference to common practices; new employees can have answers to questions without having to interrupt supervisors. Keep SOP short; in easily understandable terms; related to specific workplaces.

Manual Cleaning: If you do it, do it right! Are you using TWO basins? one for cleaning, one for disinfection or rinsing under tap water? Then disinfection bath? What size is your containment? Documentation of chemicals? (name, frequency of change, concentration)

Manual Cleaning: If you do it, do it right! TWO BASINS are needed, one for cleaning, another for disinfection! Some detergents are combinations of cleaning and disinfection chemicals; but still: TWO BASINS (and two separate solutions with the same detergent) are needed!

Manual Cleaning and Disinfection Preparation disassemble instruments if neccessary Pre-Cleaning rinsing off and through instruments under clean running water avoid forming of aerosols (a spray of little drops of water, possibly mixed with blood or contaminants): do not use hard jets of water Cleaning Lay instruments in a basin with detergent (in correct concentration), then brush, rinse, move instruments under the surface. Detergent must be able to reach all (incl. inner) surfaces. Mind correct exposure time! Rinsing rinsing off and through instruments under clean running water, removal of contaminants and process chemicals

Manual Cleaning and Disinfection Dry off instrument so as not to dilute the disinfection solution Disinfection Lay instruments in a different basin, containing disinfection solution (in correct concentration) Remove air from tubes and lumina and fill with the solution Mind correct exposure time! Final rinsing off and through instruments under clean running water Final rinsing should be done with desalinated water (reduces risk of pitting corrosion and staining) Dry instrument with (medical) compressed air or fluff-free cloth

Manual Cleaning and Disinfection Maintenance according to manufacturer s instructions as laid out in the medical device s manual Do not maintain instruments for ophthalmic surgery, they need to stay free of remnants (oil) Finally, wrap and sterilize medical devices

Endoscopes are complexe. During reprocessing they need a lot of care, manually or by an adequate washer disinfector

Cleaning is brushing, is mechanical manual action

Brushing is helpful against remnants, microbes and biofilmes Cepillos diferentes

Space at the working place?

Ultrasound bathing or cleaning? Bathing instruments in between? Noisy, dirty, smelling or a well documented precleaning site for specific instruments?

Influences to Cleaning and Disinfection Processes Design of Instruments Permeability of the inner lumen Materials and coatings Joints, Hinges Hollows, Cavities Shafts Surface properties

Influences to Cleaning and Disinfection Processes Process Chemicals Cleaning agent Disinfection agent Neutralising agent Rinse agent Concentration of the agents

Correct means, correct tools at site?

Transport without complication in baskets One touch : -> Transport -> Washing -> Sterilization

... y punto de partida para optimizar el portador de los productos médicos Transport Transport of of small instruments/pieces, small secured instruments/pieces, secured against movement against movement Equal Equal heating heating time time for metals for metals and and plastics plastics Few changes Few position position changes necessary necessary Agents Agents for for washing, disinfection washing, disinfection and sterilization and sterilization have have good access good access to to the the entire surface entire surface of of the the instrument instrument Individual instruments Individual fitting fitting of instruments and of and parts parts

Modules for technical solutions

Sources of infection: Residual moisture (condensate) provides Microorganisms with the possibility of "swimming"

Trauma containers are a drama

Improving... Instrumentenpflege 1. Visual/tactile inspection 2. Maintenance 3. Function test

The right instrument in the right place?

Documentation is knowledge Appropriate means? Just do it!

Conclusion Medical devices are not always cleaned properly by washer disinfectors. Staff is not always able to work consistently and regular. Manual cleaning remains necessary as automated devices are limited in capacity and capability. (Re-)Processors have limited access to washer disinfectors as well. Validated (re)processing is mandatory. It requires verification of parameters that are predefined, in the case of manual cleaning mainly standard operating procedures (SOP). The specifications of validation must reflect the actual state of science and technology. They are partly measurements, partly descriptions and control of fulfillment (countable/ not countable events).

FORUM workshop CLEANICAL Thank you for your attention!