CAR BURGLAR ALARM K3504

Similar documents
LED CLOCK with SLOW ON DIMMER. Total solder points: 120 Difficulty level: beginner advanced K8091EU ILLUSTRATED ASSEMBLY MANUAL

G34 AU1B (External Ultrasonic Sensor) Version 3

Service Manual 26 Self Trimming Fireplace with 3 Stage Remote

Service Manual 26 Self Trimming Export Fireplace with 3 Stage On/Off Remote

How to modify Volvo Alarm Siren after it has given Message: Alarm system Service Required Ver. 1.2

Victoreen Primalert 35 Area Radiation Monitor

Part 1: Playing with Electricity

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

INSTRUCTION MANUAL FOR. Remote Control Car Alarm with Impact Sensor, Mini-Battery Backup Siren & Engine Immobiliser

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

KIT 53. CODEPAD/ALARM USING 68HC705P9

REMOTE CONTROL CAR ALARM SYSTEM

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

IDM4 CARAVAN ALARM. Operating instructions

AXE102 PICAXE-08M2 Alarm / Steady Hand Kit

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

Control Panel Engineering and Commissioning Instructions

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MODEL 5800A CARBON MONOXIDE (CO) MONITOR AND ALARM SAMPLE-DRAWING TYPE

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

AED Alarm System Model Operations Manual

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

reading carefully this guide, operating this system strictly on the standard procedure. System 816

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FEC400 Series. Installation Manual

reading carefully this guide, operating this system strictly on the standard procedure.

LUCCI AIRFUSION RESORT DC CEILING FAN

D-TEK -MS Vehicle Loop Detector. Operating Instructions

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

/ /24 INSTALLATION AND USE MANUAL. Made in Italy AC 2710/UK Rev /12

Installation, Operating and Maintenance Manual

Constant voltage 3-phase rectifier.

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Fire Control Panel FS4000

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

Intruder alarm panel Terxon MX Operating instructions

General Purpose IO Technical Manual

User manual and installation instruction Control for Fire Ventilation RV / RV 24-32

CA60Plus. Installation manual

Conventional Fire Alarm System 2014 V1.2

CONSTANT VOLTAGE CHARGER TYPE RKAS

SERVICE MANUAL REFRIGERATION

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

ENGINEERED PARKING SYSTEMS MODEL 3416D

WM3000 WIRELESS MODULES

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Operating Instructions

-1- REMOTE CAR ALARM SYSTEM. Technical Help Line

CORNELL Emergency Response Systems

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

DOLKPS1KB Programming & Installation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN

Part. Test System Weekly See Watch ~Test. Points

Instruction Manual. for. Soldering / SMD Rework Station. For Lead-free soldering application and rework on professional SMD electronics.

HOME SECURITY MICROPROCESSOR CENTRAL UNIT HOME 5 USER S MANUAL

CONTENTS Introduction and Characteristics. 1 Fire Alarm System Assembly Diagram.. 2 Fire Alarm Signal Flow Chart.. 2 Panel Descriptions 3 Standard

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

Premier Hazard STC Instructions

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Operating Instructions

DYGIZONE GJD910 Lighting Controller & Enunciator

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

SPLIT-DECODED CONTROLLER

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GSM RFID VOICE Alarm System

Application, Installation, Operation & Maintenance Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Installation & Programming Guide

ZSC100 Gas Detection and Alarm System Controller

Fire Control Panel FS4000

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

Phoenix 2 Rev. A - Owner's Manual 0399

For silent arm / disarm use BUTTON 2.

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

Premium 8 Zone Wireless Alarm Kit

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Operation and Maintenance Manual

FX FIRE DETECTION SYSTEM

I make no guarantee(s) about this project and am not liable for any issues that may arise from the information provided here.

380 SERIES REMOTE SIREN ETSA380R

BSR Addressable Fire Detection control panel. Installation operation manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

CARSON MANUFACTURING CO., INC NORTH RURAL STREET INDIANAPOLIS, IN (888) TECHNICAL BULLETIN OFF/ON PA VOL

Operating instructions 2-channel code lock. Item No

Installation & Operating Instructions

Transcription:

CAR BURGLAR ALARM K3504 Low cost reliable car alarm. ILLUSTRATED ASSEMBLY MANUAL H3504IP - 1

Features & Specifications The alarm detects sudden voltage drops of the battery when the interior, trunk, or hood lights are switched on. To ensure correct operation, a number of control indications have been included, such as : flashing LED to indicate that the alarm is in standby mode after a set time (after you have left the car). Pre-alarm (built-in buzzer) to indicate that the alarm is activated, so that you will not forget to switch it off. The alarm is easy to switch on and off, either automatically or by means of the ignition switch or a remote control unit, such as the K8059 / K8057 or VM109. Specifications: detects voltage drops of the battery entry delay time: 2 to 30 seconds with buzzer indication exit delay time: 2 to 180 seconds with LED indication alarm period: 60 seconds with automatic reset power supply: 12V standby current: 25mA relay output: 5A PCB dimensions: 62 x 100mm (2.4" x 3.9") recommended housing: WCAH2853 2

Assembly hints 1. Assembly (Skipping this can lead to troubles! ) Ok, so we have your attention. These hints will help you to make this project successful. Read them carefully. 1.1 Make sure you have the right tools: A good quality soldering iron (25-40W) with a small tip. Wipe it often on a wet sponge or cloth, to keep it clean; then apply solder to the tip, to give it a wet look. This is called thinning and will protect the tip, and enables you to make good connections. When solder rolls off the tip, it needs cleaning. Thin raisin-core solder. Do not use any flux or grease. A diagonal cutter to trim excess wires. To avoid injury when cutting excess leads, hold the lead so they cannot fly towards the eyes. Needle nose pliers, for bending leads, or to hold components in place. Small blade and Phillips screwdrivers. A basic range is fine. For some projects, a basic multi-meter is required, or might be handy 0.000 1.2 Assembly Hints : Make sure the skill level matches your experience, to avoid disappointments. Follow the instructions carefully. Read and understand the entire step before you perform each operation. Perform the assembly in the correct order as stated in this manual Position all parts on the PCB (Printed Circuit Board) as shown on the drawings. Values on the circuit diagram are subject to changes. Values in this assembly guide are correct* Use the check-boxes to mark your progress. Please read the included information on safety and customer service * Typographical inaccuracies excluded. Always look for possible last minute manual updates, indicated as NOTE on a separate leaflet. 3

Assembly hints 1.3 Soldering Hints : 1- Mount the component against the PCB surface and carefully solder the leads 2- Make sure the solder joints are cone-shaped and shiny 3- Trim excess leads as close as possible to the solder joint REMOVE THEM FROM THE TAPE ONE AT A TIME! DO NOT BLINDLY FOLLOW THE ORDER OF THE COMPONENTS ONTO THE TAPE. ALWAYS CHECK THEIR VALUE ON THE PARTS LIST! 4

Construction 1. Jumper wires J J J Continuous alarm : JC OR JC JI Intermittent alarm : JI 2. 1/4W resistors R... R1 : 1K (1-0 - 2 - B) R2 : 1K (1-0 - 2 - B) R3 : 10K (1-0 - 3 - B) R4 : 47K (4-7 - 3 - B) R5 : 47K (4-7 - 3 - B) R6 : 47K (4-7 - 3 - B) R7 : 47K (4-7 - 3 - B) R8 : 47K (4-7 - 3 - B) R9 : 47K (4-7 - 3 - B) R10 : 680 (6-8 - 1 - B) R11 : 1M (1-0 - 5 - B) R12 : 1M (1-0 - 5 - B) R13 : 1M (1-0 - 5 - B) R14 : 220K (2-2 - 4 - B) R15 : 220K (2-2 - 4 - B) 3. Diodes. Watch the polarity! D1 : 1N4148 D2 : 1N4148 D3 : 1N4148 D4 : 1N4148 D5 : 1N4148 D6 : 1N4148 D7 : 1N4007 4. IC sockets. Watch the position of the notch! IC1 : 8p IC2 : 14p IC3 : 16p IC4 : 8p CATHODE D... 5

Construction 5. Capacitors c... C1 : 10nF (103) C2 : 10nF (103) C3 : 100nF (104) C4 : 100nF (104) 6. Trim potentiometers RV1 : 4M7 RV2 : 1M RV... 7. Transistors T1 : BC547C T2 : BC547C T3 : BC557B 8. Screw connectors J1 : 3 x 2p 9. Electrolytic capacitor. Watch the polarity! C5 : 4µ7 C6 : 4µ7 C7 : 4µ7 C8 : 220µF C9 : 220µF C10 : 47µF C11 : 47µF C12 : 100µF C13 : 100µF 10. Buzzer. Watch the polarity! BUZ1 C... Attention: the longest connection has to be put in the hole marked +. 6

Construction 11. Relay RY1 : VR15M121C (1 contact) RY... 12. IC's. Watch the position of the notch! IC1 : UA741M IC2 : CD4093 IC3 : CD4098 IC4 : NE555 Apply some extra solder to the wider PCB tracks, starting from the relay contacts towards contacts NO and COM. 7

Test & usage 13. Test & Usage Connect the LED between the points LD1 and the earth (-). Connect the + and - of the battery direct to the + and - connections of the circuit. Remark: switching the + and - connections by mistake will only cause IC1 to be destroyed, because the rest of the circuit is protected by D7. + - + - Fig. 1 Turn both trimming potentiometers to their minimum position (completely to the left). The LED should be flashing now. 8

Test & usage Connecting the point DIS to the + should extinguish the LED. Interrupting the connection should restore the flashing state after 2 seconds. This delay time, which is the step out delay time or in other words the delay time between the point of time the voltage disappears from the point DIS (coming from the ignition lock or from the remote control) and the rearming of the alarm, can be made longer with RV1. Remark: when the circuit is first powered on, the delay times may deviate. This is caused by the fact that the circuit first has to stabilize. Fig. 2 The alarm, when armed, can be activated e.g. by switching the courtesy light (however the alarm DOESN'T react upon SWITCHING OFF loads). Before the relay, which controls the alarm signal, gets activated, you will hear a buzzer tone for 2 seconds so that you have time enough to switch off the alarm. This "step in delay time" can be made longer with RV2. Remark: To use the alarm together with the infrared code lock, it is advisable to set the step in and out delay times to their minimum. Together with the alarm you could also control the central car-door locking (possibly with an additional relay depending on the type of car-door locking). 9

Final connection 14. Final Connection Take care that the under mentioned connections cannot be cut through from the outside. You can install a lamp under the bonnet which activates the alarm when the bonnet is opened. Install the LED by preference at a place where it is visible from the outside (use the supplied LED-holder if necessary). Connect the shortest connection of the LED to the earth (chassis) and its shortest connection to the point LD1 of the circuit. (A) Car burglar alarm used as stand-alone unit. Connect the klaxon or siren to the relay as shown in the figures. Attention: The common wire of the klaxon can be connected either to the + or the - of the alarm (check with a volt-meter). Connect the connecting terminals"+" and"-" of the alarm to the corresponding poles of the battery. For normal use, connect the point DIS of the circuit to a"+" wire AFTER the ignition lock. 1. Warning device connected to chassis MAX. 5A Fig. 3 10

Final connection 2. Warning device connected to "+" MAX. 5A Fig. 4 11

Final connection (B) Car burglar alarm used in combination with our RF codelock (K8057 & K8059 - VM109). Connect the klaxon or siren to the relay as shown in the figures. Attention: The common wire of the klaxon can be connected either to the + or the - of the alarm (check with a volt-meter). Connect the connecting terminals"+" and"-" of the alarm to the corresponding poles of the battery. Connect the point COM of the code lock with the "+" and the point NO with the connection DIS of the alarm. The receiver must be set to "TOGGLE" mode. 1. Warning device connected to chassis 12 Fig. 5

Final connection 2. Warning device connected to "+" Fig. 6 K8057 : 2 Channel RF codelock receiver K8059 : 2 Channel RF codelock transmitter VM109 : 2 Channel RF remote control set 13

PCB 15. PCB 14

Schematic diagram 16. Schematic diagram. 15

VELLEMAN NV Legen Heirweg 33, B-9890 GAVERE Belgium (Europe) Modifications and typographical errors reserved Velleman nv. H3504IP 1-2014 (rev.1) 5 410329 403485