PROJECT CODE: 1446 FILENAME: 1446 A0.1 Cover.dwg KKC APPROVALS: DATE: NO: DATE: Mar 31, 2016, 12:21pm COMMENTS: A0.1 TITLE SHEET
MECH. ROOM DOOR VICINITY MAP N NORTH - PARKING SPACE STATISTICS SOUTH - PARKING SPACE STATISTICS VICINITY MAP N LEGEND
PROJECT CODE: 1446 FILENAME: 1446 A1.1 Site.dwg APPROVALS: DATE: Mar 31, 2016, 12:22pm NO: DATE: COMMENTS: MECH. ROOM DOOR A1.1 SITE PLAN
A2.1 CRN - TRASH ENCLOSURE PLAN PROJECT CODE: 1446 FILENAME: 1446 A2.1 Plans.dwg APPROVALS: DATE: Mar 25, 2016, 10:11am NO: DATE: COMMENTS:
PROJECT CODE: 1446 FILENAME: 1446 A2.1 Plans.dwg APPROVALS: DATE: Mar 25, 2016, 10:12am NO: DATE: COMMENTS: A2.2 CRP - TRASH ENCLOSURE PLAN
A3.1 CRN - TRASH ENCLOSURE ELEV PROJECT CODE: 1446 FILENAME: 1446 A3.1 Elevs.dwg APPROVALS: DATE: Mar 31, 2016, 3:13pm NO: DATE: COMMENTS:
A3.2 CRP - TRASH ENCLOSURE ELEV/DETAILS PROJECT CODE: 1446 FILENAME: 1446 A3.1 Elevs.dwg APPROVALS: DATE: Mar 31, 2016, 3:13pm NO: DATE: COMMENTS:
-USE (OR AS NOTED ON PLAN LEGEND): 1 EMITTER / 1gal PLANT (or smaller) 2 EMITTERS / 5gal PLANT 3 EMITTERS / 15gal PLANT 4 EMITTERS / 24" BOX NOTES: -PLACEMENT OF EMITTERS TO BE SUCH THAT ROOT BALL IS WETTED WITHOUT HAVING WATER TOUCH PLANT STEM OR TRUNK (JUST OUTSIDE OF ROOTBALL) -ON LEVEL GROUND, PLACE EMITTERS ON EITHER SIDE OF PLANTS FOR EVEN COVERAGE. ON SLOPE EMITTERS SHALL BE ON UPHILL SIDE OF PLANT. HARDY 'TURBO SC PLUS'-DPJ04-A PRESSURE COMPENSATING 1-GPH EMITTERS INSTALL PER MFR'S RECOMMENDATIONS SEE NOTE ABOVE FOR QTY. FIGURE 8 EXTEND LINES 3' 1 GAL PAST LAST PLANT 5 GAL 6" LONG 12ga WIRE STAPLES @ 4" O.C. P.E. TUBING-ALLOW FOR EXPANSION AND CONTRACTION OF HOSE DURING INSTALLATION. SEE LEGEND FOR SIZE. DRIP EMITTER-CLAY TREE BASIN ROOT BALL 15 GAL PLANT LOOP FOR TREES (INITIAL PLACEMENT) LEVEL 15 GAL ELEVATION VIEW 3' LOOP (FOR FUTURE GROWTH) EMITTERS ROOT BALL 5 GAL PLANT TREE LOOP FOR TREES (1-3 YRS. AFTER PLANTING (NIC) DOWN SLOPE 3' LOOP BASIN PLAN VIEWS NOT TO SCALE 3-4" DEEP MULCH EDGE OF BASIN P.E. TUBING FROM DRIP ASSEMBLY. BURY 2" BELOW GRADE. NOT TO SCALE 00 DETAIL-FILE TREE TREE STAKE; 2"Ø x 8' TREATED LODGEPOLE PINE FINISH GRADE ROOT BALL; SET 1" ABOVE FINISH GRADE TO ALLOW FOR SETTLING BACKFILL MIX 2'-0" SEE NOTE W SECTION DOUBLE TREE STAKE 1X2 OFFSET WIND 1'-6" PLAN NOTES: -SET STAKES PARALLEL TO PREVAILING WINDS ALL STAKES ON PROJECT IN SAME DIRECTION -FOR SPECIMEN TREES: 15 GAL- W=18" 20"BOX - W=24" 24"BOX - W=30" 30"BOX - W=36" 36"BOX - W=42" 1X2 REDWOOD BRACE (IF REQUIRED - SEE PLAN VIEW ABOVE) 2 TREE TIES FROM EACH STAKE TO TREE. NAIL TIES TO STAKE. -SET TREE TIES AT HEIGHT DETERMINED BY EACH TREE BACKFILL MIX: 4 PARTS TOPSOIL 1 PART NITROGEN-FORTIFIED REDWOOD SHAVINGS 5 LBS. GRO-POWER PLUS PER C.Y. BACKFILL PLANT HOLE: SIZE: TWICE DIAMETER OF CONTAINER & 6" GREATER IN DEPTH. BROADCAST BONEMEAL OVER BOTTOM OF PIT AND SCRATCH INTO SOIL AT RATE OF 1/4 C. PER 1 GAL PLANT, 1/2 C. PER 15 GAL, 1 C. PER 15 GAL. AFTER PLANTING, WATER IN WELL COMPACTED BACKFILL MOUND DEMOLITION / PROTECTION PLAN EX. LANTANA TO REMAIN, PROTECT IN PLACE EX. RHAPHIOLEPIS TO REMAIN, PROTECT IN PLACE, TYP. REMOVE EX. RHAPHIOLEPIS, TYP. REMOVE EX. 4" BRISBANE BOX REMOVE EX. LANTANA NOTE: REPLACE DAMAGED OR DEAD PLANTS LIKE IN KIND. PARKING LOT HARDSCAPE DEMO PER CIVIL, TYP. - SEE CIVIL ENGINEER'S DRAWINGS REMOVE EX. 20" EUCALYPTUS NOTE: PROTECT EX. IRRIGATION LATERALS - EXTEND TO NEW PLANTERS AND INSTALL SLEEVING PER PLANTING PLAN, TYP. EX. WALL TO REMAIN BUILDING "I" SCALE: 1/8" =1'-0" TRUE NATURE KIMBERLY TRUE, MLA 5266 Hollister Ave. Suite 230 Goleta, CA 93111 TrueNatureDesign.com 805-770-2100 Date Revisions 03/29/16 N.T.S. 1 N.T.S. DETAIL-FILE 0 4' 8' 16' RUST-PROOF, 3/8" MIN. EYEBOLTS OR EYESCREWS. PLACE AS DIRECTED BY LANDSCAPE ARCHITECT. 12 GAUGE GALV. WIRE ATTACH TO WOOD FENCE, WALL, ETC. PATTERN AS DIRECTED BY LANDSCAPE ARCHITECT. EYE BOLTS @ 6-8' O.C. PLASTIC PLANT TIES WALL VINE-REMOVE STAKE UNTANGLE PLANT SPREAD OUT FANWISE VINE TIE TO WALL 3/8" EYEBOLT & THREADED ANCHOR. INSTALL @ DIRECTION OF LANDSCAPE ARCHITECT GREEN PLASTIC PLANT TIES WALL SEE BELOW EYEBOLT OR EYESCREW 3 N.T.S. DETAIL-FILE CHAINLINK FENCE 1" LOP CON (1) HAR VIO (3) LAN PU2 (4) NOTE: ADAPT EX. DRIP IRRIGATION AS REQUIRED - SEE DETAIL #2, THIS SHEET FOR # OF EMITTERS PER PLANT, TYP. PLANTING PLAN PLANT SCHEDULE TRASH CONTAINER PER ARCHITECT TREES CODE QTY BOTANICAL NAME COMMON NAME CONT WATER USE LOP CON 3 Lophostemon confertus Brisbane Box 15 gal Low EX. LANTANA TO REMAIN, TYP. EX. RHAPHIOLEPIS TO REMAIN, TYP. OF (3) ATTACH VINES TO WALL W/ TIES & WIRE - SEE DETAIL #3, THIS SHEET, TYP. OF (5) VINES WALL PER ARCHITECT - SEE ARCHITECTURE DRAWINGS PARKING LOT 4" SLEEVE, TYP. NOTE: ADAPT EX. IRRIGATION - RUN LATERALS THROUGH NEW SLEEVES TO CONNECT PLANTERS CHAIN LINK FENCE PER ARCHITECT SEE ARCHITECTURE DRAWINGS, TYP. (11)LAN PU2 (3)HAR VIO (1)LOP CON LAN PU2 (2) HAR VIO (2) TRASH CONTAINER PER ARCHITECT ATTACH VINES TO FENCE W/ GREEN PLASTIC TIES; SEE DETAIL #4, THIS SHEET, TYP. OF (5) VINES PLANTING NOTES 1. 0 (2)HAR VIO (3)LAN PU2 EX. RHAPHIOLEPIS TO REMAIN, TYP. OF (3) (1)LOP CON BUILDING "I" SCALE: 1/8" =1'-0" 4' 8' 16' Calle Real Shopping Center - Trash Enclosure 5660 Calle Real Goleta, California 93117 SHRUBS CODE QTY BOTANICAL NAME COMMON NAME SIZE WATER USE SPACING CHAINLINK FENCE HAR VIO 10 Hardenbergia violacea Lilac Vine 5 gal Low 48" o.c. GROUND COVERS CODE QTY BOTANICAL NAME COMMON NAME CONT WATER USE SPACING LAN PU2 20 Lantana montevidensis `Purple` Trailing Lantana 1 gal Low 48" o.c. PRELIMINARY NOT FOR BIDDING NOT FOR CONSTRUCTION VINE-REMOVE STAKE PLANT VINE AGAINST CHAINLINK FENCE. UNTANGLE BRANCHES. ARRANGE & FASTEN W/ GREEN PLASTIC PLANT TIES AS SHOWN. VINE TIE TO CHAINLINK FENCE VINE TIE 4 N.T.S. DETAIL-FILE LANDSCAPE DEMOLITION, PLANTING PLAN & DETAILS Drawn By KJT Sheet Of 1 Job N o. L-1 XXXXX