Complete packages with Software and Controller

Similar documents
SMS GSM Alarm Messenger

IntesisBox BACnet/IP Server - Notifier ID3000 series

Monitoring Solutions

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

Interface Modules for SENTRI

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

RACK MONITORING SYSTEM - RAMOS Ultra

Cold chain monitoring technologies. Facility monitoring

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

600 Range Dialer Installation Manual. Version 1.0

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

IP & SMS Alarm Communicator

APPLICATION DATA SHEET

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

UDC100 Universal Digital Controller Specifications

TER Active Room Temperature Sensor (Controller),

Fratech Multipath-IP

Outdoor Temperature Sensor

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Model 144H. Product Data Sheet , Rev DB February Content

Measuring Recording Online Monitoring Regulation Alarming

Conventional Smoke Detectors KFAPO

RACK MONITORING SYSTEM RAMOS Ultra

Dew point set DS 400

MiNi Server environment MoNitoriNg SySteM

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

PERMACONN PM1030 Includes DI300. Installation Manual

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

T4000 Security Communicator

Note that the cable must be handled with great care to avoid damages to the cable during transport etc.

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

EnvironmentalMonitoring

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

HOST SERVER CRITICAL INFRASTRUCTURE & ENVIRONMENTAL MONITORING SYSTEM DATA CENTER PLANT BASE STATION. Generator Fuel Level. Battery Monitoring

Accessories, interfaces, sensors and complete solutions.

Combined CAN Sensor Unit Temperature, Humidity and Smoke

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

HOBO U30 Remote Monitoring Systems

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

AirFlow Sensor for Dry Contact connection

METOS Compact SMS. The smooth change of a product. Gottfried Pessl

EasyLog Data Logger Series

Fratech Multipath-IP STU

PSM CONTROL & MANAGEMENT PRODUCT CATALOGUE. GAMATRONIC, A SolarEdge Division. 17 Hartom Street, Jerusalem , Israel

Thermoguard. Thermoguard Alarm Relay Channel Version 2.90 (as of April 26, 2014)

Analog Input Module IC670ALG630

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

Typical applications include the vibration detector. Detection of vibrations and shocks

APPLICATION DATA SHEET

CONTENT version Piccolo Object protection

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

RS485 MODBUS Module 8AI

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

GLOBAL. InstallatIon & operation manual

Relative Humidity Transmitters

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Process Alarm Module RTA 421

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

PURCHASING SECTION th Street, Surrey, B.C. V3S 3C7 Tel: Fax: ADDENDUM NO.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

EL-OEM-3 OEM Packaged Voltage Data Logger

Data Center. Cold Storage

your silent and loyal servant

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Monitoring. Catalog Data Input Processing M2M Transfer SW Applications.

Microprocessor Based 16 Channel Temperature Scanners (Product Code 7.2 To 7.3) MSI-16-H

Dräger X-zone 5500 Area Monitoring

Easy Series ICP-EZM2. System Reference Guide

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

GSM RFID VOICE Alarm System

Intelligent addressable fire alarm control panel

CAN unit for Analog Sensors

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

Duct and Rough Service Carbon Monoxide Sensor

Zareba Unipoint controller

Engineering Guideline. pac- Carriers Type Universal

GSM/SMS/3G/4G. Remote Alarm Controller Digital Input Monitoring Alarm Unit. S130/S140/S150 User Manual. Ver 3.0. Date Issued:

gas monitoring system

Model KBF 240 Constant climate chambers with large temperature / humidity range

MANUAL FOR PROFORT GSM/LAN DEVICES Ver MANUAL FOR PROFORT GSM/LAN DEVICES 3

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

7 USE THE COMMANDS INTERNET VOICE MESSAGES RECORD VOICE MESSAGE DURATION OF VOICE MESSAGES 64

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Dräger Polytron 7000 Fixed gas detector

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

DC-RMCU1 DC-Powered Remote Monitoring and Control Unit Owners Guide

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Panel Mounted Fault Annunciator Series

Transcription:

Thermoguard Basic Complete packages with Software and Controller Thermoguard Basic packages contain the software, one sensorcontroller and one sensor. The functional scope of the Thermoguard Basic software is identical to the Thermoguard Professional software but it only allows you to use one single sensorcontroller. Thermoguard Basic packages can be upgraded to Thermoguard Professional at any time. Thermoguard Basic1: Software, Sensorcontroller SC1ePn, 1 sensor PT100 725 Delivery contains: 1 x Thermoguard Software Basic 1 x Sensorcontroller SC1ePn, Power Supply 1 x Temperature sensor PT100 (-50..+180 C) Thermoguard Basic2: Software, Sensorcontroller SC2ePn, 1 sensor PT100 855 Delivery contains: 1 x Thermoguard Software Basic 1 x Sensorcontroller SC2eP, Power Supply 1 x Temperature sensor PT100 (-50..+180 C) Thermoguard Basic8: Software, Sensorcontroller SC8eP 1 sensor PT100 995 Delivery contains: 1 x Thermoguard Software Basic 1 x Sensorcontroller SC8eP, Power Supply 1 x Temperature sensor PT100 (-50..+180 C) 1 x DIN rail for mounting, about 9 cm Thermoguard HM Basic1: Software, HygroLAN-Controller HM1Pn 1 combined Temperature-/Humidity -/Atmospheric Pressure sensor 1.025 Thermoguard HF Basic1: Software, HygroLAN-Controller HF1Pn 1 combined Temperature-/Humidity sensor 985 Delivery contains: 1 x Thermoguard Software Basic 1 x Controller HM1Pn or HF1Pn Power Supply HM1Pn: 1 x Temper.-/Humidity-/Pressure sensor HF1Pn: 1 x Temper.-/Humidity sensor Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 1 of 9

Thermoguard Professional and Upgrade Software Thermoguard Professional: Software for central data recording of virtually any desired number of Thermoguard sensorcontrollers. Unlike Thermoguard Basic, Thermoguard Professional can centrally poll (interrogate) and monitor several sensorcontrollers. A typical area of application is monitoring for large numbers of cooling/refrigeration appliances, climatic chambers or incubators distributed throughout several rooms, buildings or locations. Thermoguard Professional: Software V2.9x 1.360 Thermoguard Professional is suited for all Microsoft Windows Operating Systems currently supported by Microsoft Thermoguard Professional Upgrade Software Upgrade for Thermoguard Basic Software to Thermoguard Professional. You can continue using your existing sensorcontrollers.. Thermoguard Professional: Software Upgrade 995 The Thermoguard Professional Upgrade is suited for all Microsoft Windows Operating Systems currently supported by Microsoft Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 2 of 9

Thermoguard SC1ePn, SC2eP and SC8eP Sensorcontroller Several Thermoguard sensorcontrollers are available: The SC1ePn "single" controller for one temperature sensor, the SC2eP dual controller to connect one or two sensors, and the SC8eP providing ports for a maximum of eight sensors. The HygroLAN Controller HM1Pn allows you to monitor and record temperature, relative humidity and atmospheric pressure with its included combined digital sensor (w/o pressure available as model HF1Pn). Thermoguard Sensorcontroller SC1ePn -200 C to +650 C 360 Supported Temper. sensors: Measuring range, resolution: Supply voltage: 1x PT100 or PT1000 with 4-wire technology -200 C...+650 C, 1/10 C ±0,3 C ± 0,2 % typically 62mA @24VDC Thermoguard Sensorcontroller SC2eP -200 C to +650 C 490 Supported Temper. sensors: Measuring range, resolution: Supply voltage: 1 to 2x PT100 or PT1000 with 4-wire technology -200 C...+650 C, 1/10 C ±0,3 C ± 0,2 % typically 70A @24VDC Thermoguard Sensorcontroller SC8eP -200 C to +650 C 630 Supported Temper. sensors: Measuring range, resolution: Supply voltage: 1 to 8x PT100 or PT1000 with 4-wire technology -200 C...+650 C, 1/10 C ±0,3 C ± 0,2 % typically 65mA @24VDC Plastic housing, 107 x 88 x 63 mm, Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 3 of 9

Thermoguard HM1Pn/HF1Pn HygroLAN Controller Thermoguard HygroLAN-Controller HM1Pn including combined Temperature-/Humidity-/Atmospheric Pressure sensor 520 Thermoguard HygroLAN-Controller HF1Pn including combined Temperature-/Humidity sensor 480 Sensor included: Measuring range, resolution: Supply voltage: for HM1Pn (for HF1Pn specifications for barometric pressure do not apply): Combined digital sensor for temperature, relative humidity and barometric pressure, 2m cable -40 C..+85 C, 1/10 C; 0..100% rh, 0,1%; 10..1100hPA, 0,1hPA ±0,3 C; ±2% rh (@23 C); ±0,8hPa (750..1100hPa, @25 C) typically 62mA @24V DC Options for HM1Pn/HF1Pn Splash water protection for HM1Pn/HF1Pn sensor 35 Optionally HM1Pn/HF1Pn can be ordered with a splash water protected combined sensor (sintered bronze cap): Protection class IP X4 Sealing according to DIN 40050: 1993 Part 9 Calibration of HM1Pn/HF1Pn including combined digital sensor 175 Optionally Thermoguard offers a factory calibration (Temperature and Humidity, atmospheric pressure excluded) Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 4 of 9

Thermoguard Temperature Sensors Temperature sensors for Thermoguard sensorcontrollers are available in a variety of designs for specific areas of use. On request, all the sensors can be factory calibrated with a certificate. Please ask us about special sensors for your particular application! Special cable length for designs with solid connection leads on request. Temperature Sensor Screw Mounting, PT100-50 C to +200 C 65 Temperature sensor for screw mounting to monitor temperatures, Type PT100. Temperature range -50 C to +200 C. Four wire connection, 10 m solid connection lead. Silicone cable with Teflon isolation of inner wire. Dimensions: 8 x 8 x 40 mm. Accuracy: DIN 60751 Class A Low Temperature Sensor, PT100-90 C to +200 C 110 Stainless steel temperature sensor for screw mounting to monitor ultra low temperatures. Type PT100 with coiled sensor probe. Temperature range -90 C to +200 C. Four wire connection, 10 m solid connection lead TT 4 x AWG 22. Dimensions: 8 x 8 x 40 mm. Accuracy: DIN 60751 Class A Very low temperature sensor "KW1", PT100-190 C to +180 C 245 Temperature sensor KW1, Type PT100, sealed, Temperature range -190 C to +180 C; Four wire connection, 10 m solid connection lead, cable type TT 4xAWG 26; stainless steel head; drummed twice; Dimensions: round shape, 5mm diameter, 100mm length; Accuracy: DIN 60751 Class A Temperature Sensor Indoor, PT100-40 C to +85 C 55 For measuring and monitoring temperatures in indoor rooms, type PT100. Version with slotted plastic housing. Temperature range - 40 C to +85 C. Four wire connection; connection lead not included. Dimensions: 70 x 70 x 27 mm. Accuracy: DIN 60751 Class A Temperature Sensor Cold Storage, PT100-40 C to +90 C 95 Temperature sensor, wall mounting, sealed plastic housing, type PT100. For measuring and monitoring temperatures in cooling chambers, climatic chambers, storage areas and machine halls; temperature range -40 C to +90 C. Four wire connection; connection lead not included. Dimensions, housing including sensors: 145 x 58 x 34 mm. Accuracy: DIN 60571 Class A Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 5 of 9

Calibration of temperature sensors Basic Charge (per Design): 125 Additional charge per sensor: 50 Thermoguard offers an optional factory based calibration for the Thermoguard PT100 sensors. The sensors will be calibrated at two measuring points by comparative measurements in an external laboratory. Traceability of the measurements to national standards is guaranteed. Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 6 of 9

Thermoguard Sensorcontrollers for analog values The Analog Controller series AC2 provides the possibility to record and monitor analog current values from 0-20 ma and voltage values from 0-10 Volt via the network. With the help of standardized transmitters practically all physical values can be recorded and controlled. Just some examples: Current, voltage, power, (air) pressure, light, frequency are just a few examples. Thermoguard Sensorcontroller AC2aPn 360 Input: Resolution: Supply Voltage: 2x Current: 0/4..20 ma, 100 Ohm Current input: 2.5 µa max. 0,5 % FSR (Full Scale Range 0..20 ma) T A = 0-60 C typically 100mA @24V DC Thermoguard Sensorcontroller AC2vPn 360 Input: Resolution: Supply Voltage: 2x Voltage: 0..10 V, 1 MOhm Voltage Input: 1,25 mv max. 0,5% FSR (Full Scale Range 0..10V) T A = 0-60 C typically 100mA @24V DC Thermoguard Water Detector Thermoguard Water Detector TG-W, ready for connection 485 Included: Housing SC1ePn fixed with mounting bracket DIN rail switching power supply 24V DC Water Detector with sensor, 5m cable (optionally one additional sensor connected in parallel, +25 ) Adapter /w resistors wired for Alarm Relay Channel operation 4 end clamps RJ45 "Feedthrough" Reset switch on housing 230V~ Connection cable, 5m, white with angled plug Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 7 of 9

GSM Modem By default, Thermoguard sends "e-mail as SMS" to mobile phones. In addition or alternatively the Thermoguard Software supports sending alarm or "heartbeat" messages directly over a GSM modem independently of an e-mail Server. The unit is supplied ready for connection in a mounting housing. A SIM card is required for operation. Two versions are available: GSM Modem, Serial Version 345 For direct connection to a free COM port* of the Thermoguard PC Included: Mounting housing with four wall mounting lugs DIN rail switching power supply, 24V DC GSM modem Antenna with magnetic base Serial connection cable (5m) 230V~ connection cable (5m) *or via USB-to-serial adapter GSM Modem, COM Server Version 425 For connection anywhere in the network* Included: Mounting housing with four wall mounting lugs DIN rail switching power supply, 5V DC GSM modem Antenna with magnetic base COM server with driver software for "virtual COM port" 230V~ connection cable (5m) *RJ45 connection cable not included Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 8 of 9

Thermoguard Mounting Cases and other Accessories Mounting Case including Power Supply for SC1ePn/SC2eP/AC2nPn/Hn1Pn 75 Mounting Case for wall mounting DIN rail switching power supply 24V DC included Dimensions WxHxD = 178 x 130 x 75 mm Without primary power cable. Power supply has to be wired by an authorized electrician. ISO Mounting Case including Power Supply for SC8eP 85 ISO Mounting Case, IP55, 10 units, for one sensorcontroller SC8eP DIN rail switching power supply 24V DC included Dimensions WxHxD = 230 x 180 x 110 mm Without primary power cable. Power supply has to be wired by an authorized electrician. Relay Interface, serial connection 265 Relay Interface Module with serial connection for switching of up to 8 external devices via potential-free relay contacts Mounted in ISO case including 12V DC DIN rail switching power supply and connection cable. Without primary power cable. Power supply has to be wired by an authorized electrician. Calibration Set 795 Thermoguard temperature calibration set with transport box. Contains a calibrated sensor controller SC1ePn and temperature sensor, calibrated together as one unit. Including factory certificate. For comparative On-Site Calibration of already mounted temperature sensors Thermoguard www.thermoguard.com Products and Prices as of March 1, 2019 Page 9 of 9