The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

Similar documents
The D1000. Typical Specifications: Standard Options*: Model: D1030-I_-DF Spec & Submittal Version 2.3 D1000-I_-DF D1000-I_-DF-NFPA101

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

The D1000. Typical Specifications: Standard Options*: Model: D1030-R Spec & Submittal Version 2.1 D1000-R_ D1000-R_-NFPA101

XRRS Specification Fire Ready Hood

The D1000. Installation and Service Manual

EVALUATION SUBJECT: FIRE SUPPRESSION RANGE HOOD DIVISION: MECHANICAL SECTION: COMMERCIAL-KITCHEN HOODS.

CORE Protection Fire System Specification

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Ventless Operation Supplement GBF-D-VH

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Installation, Operation and Maintenance Manual

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR KITCHEN EQUIPMENT

Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

PARTS LIST. SERVICE PARTS LIST WVG-136 Ventless Griddle with or without Roll Warmer CONTENTS

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

PARTS LIST PL503 WVF-886 VENTLESS FRYER WITH OR WITHOUT ROLL WARMER CONTENTS

Installation, Operation and Maintenance Manual

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Types of Detection. Fusible Link Detection - Most Common

EVALUATION SUBJECT: GILES RECIRCULATING (VENTLESS) HOODS

Professional Ventilators

SPECIFICATION: DRY CHEMICAL FIRE SUPPRESSION SYSTEM FOR INDUSTRIAL APPLICATIONS MODEL IND

Agent Tanks PCL PCL PCL PCL - 600

FEATURES AND BENEFITS

PML SD Ventilators. Professional Mesh Liners Technical Features: Dimmer controlled halogen lighting

THE IDEAL SOLUTION FOR KITCHENS

KIC Air Curtains. Technical Guide

SECTION COMMERCIAL-KITCHEN HOODS

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Standard Features. Performance/Capacities

30" Electric Downdraft Slide-In MODELS: (Stainless) 05/31/ Sears Brands, LLC Part No. W Rev. B

Indirect Gas-Fired Make-Up Air

CATALOG OF REPLACEMENT PARTS

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

BCX-14 & BX-14 COMBINATION OVEN STEAMER CNVX-14 CONVECTION OVEN REPLACEMENT PARTS LIST

Replacement Parts List For Models COS-101 COS-101S

Direct Fired Heater Model AD Specification

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

Replacement Parts List For Models COS-20G

Steel Casework Acid Storage

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Dear Concessionaire,

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Over-the-Range Microwave professional series

Service & Testing Manual. Series. 20 Denlar Dr. Chester, CT (860) Fax: (860)

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

Effective october 14, 2014

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

KIDDE WHDR WET CHEMICAL FIRE SUPPRESSION AND INTELLIGENT CONTROL SYSTEM FOR COOKING OPERATIONS WITH ARIES-NET MULTI-LOOP INTELLIGENT CONTROL UNIT

Effective october 14, 2014

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

V * V V V V V-25L-230* V * V *

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

NFPA 96, 2017 REVIEW SUMMARY

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID

Providing Quality Ventilation Since modern-aire. Range Hoods

MODEL: JRSVH SERIES JEAN S RESTAURANT SUPPLY 426 SOUTH STAPLES CORPUS CHRISTI, TEXAS PH: (361)

Installation. Professional Built-in Hoods

PA 500/1100V Ultra Quiet Ventilation Fan

COMMERCIAL ELECTRIC DRYER

Over-the-Range Microwave

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

ICC CODE CORNER 2015 International Fire Code

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

TELESCOPIC HOOD SL10160I-3 SRECO160I-2 TECHNIKA USER S MANUAL 安装和 INSTRUCTIONS FOR INSTALLATION AND USE 使用指示

Direct Gas-Fired Make-Up Air

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Gas and Electric Convection Ovens

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Glass Canopy Wall-Mount Hood

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

APPUZO RANGE HOOD INSTALLATION

Residential Balanced Ventilation Systems

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

60 Years of Commercial Kitchen Fire Suppression

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Operations & Service Manual

for FRYER MODELS WVAE_30F WVPE-30F WVAE-55F WVAE-55FS SUPPLEMENTAL SERVICE INSTRUCTIONS VENTILATOR HOOD SECTION

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Conveyor. AJ-44 Vision Series. Standard Features. Power/Connections. Performance/Capacities

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

ANSUL I-101 INDUSTRIAL FIRE SUPPRESSION SYSTEM TECHNICAL MANUAL VEHICLE PAINT SPRAY BOOTH PROTECTION MANUAL

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

Centro-Matic Automated Lubrication Systems System Controls

Gas-Fired Indoor and Outdoor Duct Furnaces

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Cooker Hood User Manual

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Transcription:

Fan 10 Ductwork Cabinet 7 to 10 adaptor set Range Hood Fan D1000-I_-DF Air Flow Plenum Ready Supply Cable to Fan 120VAC Input Supply Line 120VAC Output Line, Power Disconnect D1000-I_-DF-NFPA101 12 Ductwork Cabinet 7 to 12 adaptor set Range Hood Cable to Fan Air Flow Plenum Ready Supply 120VAC Input Supply Line 120VAC Output Supply, Power Disconnect Typical Specifications: Hood shall: - be D1000 Series by DENLAR Fire Protection - be wall mounted so that the bottom of the mounting bracket sits 24 to 30 above the range - be of stainless steel construction (#18 & #20 GA, polished 304) with no sharp edges and brushed finish - have factory installed fire suppression system - have 212 or 280 degree fusible link (30 vs 36 ) which will activate the mechanical fire suppression system - have Wet chemical extinguishing agent: Low PH Amerex 660 (pressurized potassium citrate / potassium acetate mix) - have centrifugal fan with air delivery of 380 to 610 CFM, fan speed controller will be infinitely variable - be ETL listed, tested to UL300A standards, - fan motor shall be permanently lubricated and meet UL507 - include a power disconnect device for gas and electric appliances, activated at suppression system discharge - automatically disconnect range element once a certain preset temperature in reached - Unit shall have multiple alarm contacts pre-installed (local, remote and trouble alarms) and an audible buzzer - Lighting shall be by 60w shatter-proof bulb MPK - Manual Pull Station Kit NSF - Upgrade to National Sanitation Foundation Compliance ADA - Handicap Accessible Control Box CLBX - THE CLOCKBOX (Password Protected, Range Element Timer) NFPA101 - Upgrade to NFPA Life Safety Code Compliance Custom Powder coat Finishes Are Available Width Fan Type Venting CFM (at hood) DUCT LENGTH (max) D1030- F_ 30" INTERNAL FRONT (recirculating) 140 CFM N/A D1030- F_ (NFPA101) 30" INTERNAL FRONT (recirculating) 500 CFM N/A D1030- R_ 30" INTERNAL REAR EXPELLING 250 CFM N/A D1030- R_ (NFPA101) 30" INTERNAL REAR EXPELLING 500 CFM N/A D1030- I_- DF 30" In- Line Duct Fan Vertical Duct 470 CFM 35 FEET D1030- I_- DF (NFPA101) 30" In- Line Duct Fan Vertical Duct 510 CFM 35 FEET D1030- I_- WF 30" Exterior Wall Fan Vertical Duct 150 CFM 20 FEET D1030- I_- WF (NFPA101) 30" Exterior Wall Fan Vertical Duct 550 CFM 20 FEET D1036- F_ 36" INTERNAL FRONT (recirculating) 140 CFM N/A D1036- F_ (NFPA101) 36" INTERNAL FRONT (recirculating) 500 CFM N/A D1036- R_ 36" INTERNAL REAR EXPELLING 250 CFM N/A D1036- R_ (NFPA101) 36" INTERNAL REAR EXPELLING 500 CFM N/A D1036- I_- DF 36" In- Line Duct Fan Vertical Duct 470 CFM 35 FEET D1036- I_- DF (NFPA101) 36" In- Line Duct Fan Vertical Duct 510 CFM 35 FEET D1036- I_- WF 36" Exterior Wall Fan Vertical Duct 150 CFM 20 FEET D1036- I_- WF (NFPA101) 36" Exterior Wall Fan Vertical Duct 550 CFM 20 FEET Volts = 115 :: Hz = 60 :: Amps = 5 :: Light Bulb = 60A15/TF :: Elec. Cutoff = 50A- 208VAC Relay :: Gas Cutoff = 120VAC Solenoid Standard Options: 1

System Anatomy:: D1030-I_-DF Extinguisher Tank Safety Key Mounting Bracket S.S. Drip Cup D1000 System S.S. Grease Baffle Top View S.S. Drip Cup S.S. Grease Baffle Suppression Piping Note: Front Grille (charcoal filter) is only found on hoods with the F calibration Fusible Links D1000 System Mounting Bracket Bottom View 2

Integrated Fire Suppression System Cut-Away View from Bottom Nozzle Type: 40 degree Conical Spray Number of Nozzles: 4 protecting the appliance 1 located in the plenum Chemical Agent: AMEREX 660 -low PH wet chemical Bottle Volume: approximately 1.5 liters 3

0" 22 1/8" 29 7/8" System & Components 5 13/16" 6 9/16" D1030: Outer Shell 29 7/8" 7 5/8" 3 5/16" 10 1/2" 19 3/8" 4

D1000: Standard Mounting Plate D1000: NFPA101 Mounting Plate D1030TC: 30 Top Cover for I unit Indicates OPTIONAL component 5

D1000-G: Controlled GAS Solenoid Valve 8 feet MC wire D1000-E: Electric Range Element Disconnect 8 feet MC wire D1000-MPK: Manual Pull Station Kit 25 feet wire rope cable 3 corner pulleys Indicates OPTIONAL component 6

D1000-ADA: Handicapped Accessible Control Box 8 feet shielded MC wire -plug & play connection D1000-CLBX: CLOCKBOX II Range Element Timer / Password protected System 20 feet shielded communication cable Indicates OPTIONAL component 7

D1000-DF: Standard In-Line Exhaust Fan 25ft plenum rated wire -plug & play connection NFPA101 Calibration: : D1030-I_-DF-NFPA101 The NFPA101 Upgrade to the DENLAR D1000 is intended to offer total compliance to a 2012 Amendment to The NFPA Life Safety Code section 18.3.2.5.3. The NFPA101 calibration packages the following options into one simple upgrade: +500cfm of Air Delivery, a Manual Pull Station Kit and The CLOCKBOX. D1000-DF: NFPA101 In-Line Exhaust Fan 25ft plenum rated wire -plug & play connection 8

D1000 Electrical Diagram - Complete Schematic 9