Appendix 1 LACCD Districtwide Security Performance Requirements

Similar documents
DIVISION 28 ELECTRONIC SAFETY AND SECURITY

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Access Control System - CAAMS. Basis of Design

BSD Technical Standard. Division 28: Electronic Safety & Security

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

CARD ACCESS CONTROL SYSTEM

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

ACTIVE INFRARED BARRIER

Card Access Control Specifications

USD 380 Centralia, Frankfort & Vermillion

SECTION INTRUSION DETECTION

APPENDIX F: LOCKSETS AND ACCESS CONTROL

A Beginners Guide to Inner Range Systems

Access Professional Edition. The flexible access control system that grows with your business.

ARCHITECTURAL AND ENGINEERING SPECIFICATION

ELECTRONIC SAFETY AND SECURITY SYSTEMS

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

I. See paragraph 1.1 in specification section SCOPE OF WORK FOR CONTRACTORS. II. See paragraph 1.1 in specification section

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

DIVISION 28 ELECTRONIC SAFETY & SECURITY Section Title Number ELECTRONIC SAFETY AND SECURITY

PIV-Enabled. Access Control Solutions for Government Facilities

RFP Addendum 2 March 31, 2016

106. LOCK AND CARD ACCESS GENERAL DESIGN INFORMATION

ACCESS CONTROL ENTERPRISE SYSTEM (ACES) CARD ACCESS DIVISION , ISSUE # 6, JANUARY,

Fiber Optic Cable Fence Disturbance Sensor

EC-BOS-602/616 AX Security

16722 ELECTRONIC SAFETY AND SECURITY SYSTEMS

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

SECTION SECURITY AND ACCESS CONTROL

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Access CONTROL. MANAGEMENT Software

DS7400Xi Addressable Control/ Communicator

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

NATIONAL TRAINING BOARD (ELECTRICIAN) REGULATIONS 2008 BR 54/2008 NATIONAL OCCUPATIONAL CERTIFICATION ACT :38

D1255RB/D1256RB/D1257RB

DESIGN GUIDELINES AND TECHNICAL STANDARDS

DS160/161 Request To Exit PIR sensors Installation Instructions

DIGI*TRAC Annunciator Guide DTA

Paradox Integration Module Settings Guide

RMS/RPX Reader. User Manual

OnGuard 7.2 Resolved Issues

Electronic Safety and Security

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

CBI-064. User Manual. Caddx to KNX-BUS Interface

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

RE6100 Series Helix Security and Automation Platform

APPENDIX E ACCESS CONTROLS SYSTEM DESIGN GUIDELINES (TAMPA CAMPUS)

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

ELT-KLED EliteSuite LED Keypad Installation Manual

Building Integration System. Your platform for customized security and safety management.

KT-100 Door Controller

Security Considerations for Secure Workplaces

CODE SUMMARY REQUIREMENTS (NEW CONSTRUCTION/TENANT IMPROVEMENT (TI))

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

NetworX Series NX-4V2 Control Panel Installation and Startup

Access Control (card access)

DOOR MONITORING/DURESS SYSTEM

NetworX NX-8V2. LED Keypad User Manual

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Why Should You Invest In An Access Management System?

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Advisor Advanced Mobile Application User Manual

To activate the Net2 alarm integration software the correct check box must be ticked on the features tab in the Net2 server configuration utility.

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

Dell and Lenel Grow Globally, Together

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Instructions

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Request for Proposal (RFP) # For Building Access Control System Upgrade Posting Date: May 11, 2016

NETWORX TM. User manual NX-4

D3D Wi-Fi GSM Smart Alarm System -User Manual

Developing a Healthcare Facility Fire Door Inspection Program

SECURITY SYSTEM NOTES

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Table of Contents. Appendix A Special Characters 31

UNC100 Integra Manual

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

Four-Door Access Controller User s Manual

Networked Access Control Panel. Installation Guide

HEAD OFFICE, SECURITY DEPARTMENT

Version 1.03 January-2002 USER S MANUAL

Austin Independent School District Police Department Policy and Procedure Manual

Cardax System Comparison

CRC Technical Reference Manual P/N Rev NOV01

Comprehensive Security for Banks and Credit Unions

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

NetworX Series NX-1500E LED Keypad

ELECTRONICACCESS ANDELECTRONICSECURITY BUDGETPRESENTATION

Integrated Security Solutions

CONSTRUCTION REQUIREMENTS

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Transcription:

Appendix 1 LACCD Districtwide Security Performance Requirements

SECTION LISTING 28 01 10 Overview 28 13 00 Access Control System 28 13 01 Access Control System Installation 28 13 26 Access Control Remote Devices 1 P a g e

28 01 10 Overview 1. The operation and maintenance of the Physical Access Control System software, servers, and field processors fall under the authority of LACCD IS Department. Any and all changes or modifications to any of these shall be coordinated with the LACCD IS Department prior to commencement of activity. 2. The operation and maintenance of the Physical Access Control System electrified locks and associated door hardware fall under the authority of LACCD Facilities Department. Any and all changes or modifications to any of these shall be coordinated with the LACCD Facilities Department prior to commencement of activity. 28 13 00 Access Control System 1. DESCRIPTION a. The PACS componentry consists of items including, but not limited to: Lenel-S2 System Controllers Lenel-S2 Reader Interfaces HID Card Readers Lenel-S2 software client software Lenel credential design and printing software Districtwide Lenel-S2 Master Server Distributed Lenel-S2 servers (1 at each College) Lenel-S2 OnGuard Enterprise Software Cabling and network supporting infrastructure and devices b. All servers and software associated with the PACS shall be administered by LACCD IS Department. c. LACCD shall retain a Master Lenel Integrator to oversee system programming, configuration, and commissioning alongside the Integrator selected to perform the installation and configuration of the field devices. d. Per LACCD Chancellors Directive 185, all perimeter doors into buildings containing classrooms as well as all perimeter doors leading directly into classrooms shall have electronic access control integrated into the Districtwide PACS. 28 13 01 Access Control System Installation 1. DESCRIPTION a. Refer to Appendix 2 Typical Access Control Installation Details for installation of all components. Installation details shall be clarified, deleted, or added to on a project by 2 P a g e

project basis through coordination between the Designer, the General Contractor, if applicable, and the LACCD CPM. b. The Integrator for this scope shall be responsible for the procurement and installation of a complete Physical Access Control System, including: all electronic components generally considered to be directly related to the functions of an access control system integration of this system with the existing PACS procurement and transfer of any and all applicable Lenel hardware, software, or firmware licenses. c. Based upon the scope requirements as detailed in 28 13 01.1.b above, the integrator shall have the following certifications: Be designated by Lenel-S2 as a Value-Added Reseller (VAR) Be established as, or obtain status as, an LACCD Lenel-S2 VAR Have a Registered Communications Distribution Designer (RCDD) on staff d. Some of the PACS components will be specified and provided under Division 8 Doors and Windows. This will typically include hardware attached to the door and power supplies for hardware attached to the door. Project designer shall add a matrix of responsibility to project drawings as to delineate scope responsibilities. Contractor shall coordinate all access control installation activities with Division 8 Contractor. 2. INSTALLER REQUIREMENTS a. All installation of materials and equipment specified under the LACCD Districtwide Security Performance Specifications shall be completed by Lenel Certified Technicians. b. At least one installer assigned to the project shall have a current Lenel Enterprise certification. 3. PROJECT MANAGEMENT a. Integrator shall provide a Project Manager who is experienced in the administration and supervision of the security field and electrical work, both within the various types of security integration and with relation to other types of work and who is hereby authorized to act on behalf of Integrator. b. The project manager responsibilities will include but are not limited to providing schedules, attending project meetings, submittals, safety, quality control, and testing, training and asbuilt documentation. c. The project manager must be an employee of Integrator and working in the security field. 4. PROJECT COORDINATION 3 P a g e

a. Integrator shall coordinate meetings with all related trades to ensure that all necessary work by other trades is proceeding according to the project schedule and that there are no gaps in scope to provide a complete functioning access controlled door system. b. Related trades include but are not limited to the Door Hardware vendor, Auto-operator accessibility door vendor, LACCD Campus IT, Master Integrator, Low Voltage Contractor, and Electrical Contractor. 5. SYSTEM CONFIGURATION a. Integrator shall provide the necessary reader licenses to support the quantity of readers for the project. Licenses are ordered in blocks of 64 readers and the number of readers shall be rounded up to the nearest multiple of 64 to obtain the correct quantity of licenses. b. The licenses shall be delivered to the District representative to be added to the system license server. c. Integrator shall complete the programming sheets that document the panel loading schedule and provide to the LACCD PM so the Master Integrator can complete the programming in a timely manner prior to system power up and commissioning. Sample schedules and instructions will be provided by the LACCD PM. d. Integrator shall program the IP addresses according to the scheme provided by the LACCD PM and document them in the IP device worksheet along with MAC addresses and user names and passwords for all field hardware panels. e. Integrator shall install the access panels and interface boards according to the programming sheets completing all wiring between boards, lock control modules and field wiring. f. All locks shall be tested along with the door position switches and request to exit devices and deficiencies corrected prior to scheduling a system commissioning test with the LACCD PM and Master Integrator. 28 13 26 Access Control Remote Devices 1. APPROVED DEVICES a. Refer to Appendix 2 for all typical device installation and cabling details. b. The following is a list of access control field equipment that is approved for installation based upon system requirements: I. Single Reader Interface Module: Lenel LNL-1300-S3 II. Dual Reader Interface Module: Lenel LNL-1320-S3 III. Intelligent Dual Reader Controller: Lenel LNL-2210 IV. Intelligent Dual Reader Controller: Lenel LNL-X2220 V. Advanced Dual Reader Controller: Lenel LNL-X4420 VI. Intelligent System Controller: Lenel LNL-X3300 VII. 16 Input Control Module: Lenel LNL-1100-S3 VIII. 16 Output Control Module: Lenel LNL-1200-S3 IX. RS-485 Multiplexer: Lenel LNL-8000 X. Standard Wall Mount Card Reader: HID iclass SE R40 using OSDP communication, Mobile ready 920NMPTEKEA007 XI. Wall Mount Card Reader with Integral Keypad: HID iclass SE RK40 using OSDP communication, Mobile ready 921NMPTEKEA008 4 P a g e

XII. Mullion Mount Card Reader: HID iclass SE R15 using OSDP Communication, Mobile ready 910NMPTEKEA007 XIII. Unified Power Enclosure with SNMP: LifeSafety FPO150-D8C8P2NL2E4M XIV. Unified Power Enclosure: LifeSafety FPO150-D8C8P2E4M XV. Request-to-exit device (when not integrated into locking hardware): Bosch DS160 XVI. Door Position Switches: Schlage 7764 2. CONTROL PANELS a. Place power supply and associated hardware in same location. b. Label per LACCD labeling standards. 3. CARD READERS a. Wire the card reader using four conductor Telecommunications Industry Association / Electronic Industries Association (TIA/EIA) compliant RS-485 wiring to achieve secure encrypted communication using the latest Open Supervised Device Protocol standard. b. Readers shall be ordered with the optical tamper enabled. c. The card reader is to produce an audible beep tone to indicate to the user: I. The card was read and/or access was denied. II. Door is being held open and needs to be closed. d. Label per LACCD labeling standards e. Readers must support HID iclass corporate 1000 series cards as well as any LACCD credential issued since 2008. f. Whenever possible, a single composite cable ( banana cable ) shall be utilized to connect door access control components to the door controller. g. All devices shall be homerun directly to the system / door controller. 4. DOOR HARDWARE a. Connect fire alarm output to the disconnect relay on the associated 24VDC lock power supply for fail-safe, egress-controlled doors only. b. Setup and conduct a door hardware coordination meeting. c. Coordinate the installation and termination of the security cable with the installation of the electric door hardware and transfer hinge. d. It is the intent of the District that all perimeter doors leading to areas containing classrooms or directly into classrooms shall be capable of remote lockdown from the existing District wide access control system. e. Provide cable and terminate wires to delayed egress devices for monitoring activation of delayed egress by the PACS system if applicable. f. Door magnet style locking hardware (Electro-Magnetic Locks or Maglocks) shall not be used without prior written approval from LACCD IS Department. g. All doors with card readers shall have a hydraulic closer installed. h. ADA Low Power Energy (LPE) doors where required shall include access control and proper peripherals equipment and the involved trades shall coordinate all aspects of the installation. i. All devices shall be homerun directly to the system / door controller. 5 P a g e

j. Any new electronic access control installed on doors which fall under the prescripts of Chancellor s Directive 185 shall be capable of supporting both interior mechanical lockdown as well as remote electronic lockdown. 5. DOOR CONTACTS a. Install on protected (secured) side of door. b. Install 6 from leading edge at top of door. c. Perimeter door contacts shall be Double-Pole, Double-Throw (DPDT) to permit connections to both the Access control and Intrusion systems. d. Coordinate with the door frame supplier for location where the frame will be grouted. e. Whenever possible, a single composite cable ( banana cable ) shall be utilized to connect door access control components to the door controller. f. All devices shall be homerun directly to the system / door controller. 6. REQUEST-TO-EXIT a. Mount motion detector on the secured (protected) side of door. b. Install motion detector so that detection pattern is not obstructed by Exit Signs, light fixtures and other objects that would interfere with proper operation. c. Set motion detector to a 1 second pulse. d. Mask detector lens to provide a confined detection area limited to the door handle or push bar. e. Whenever possible, a single composite cable ( banana cable ) shall be utilized to connect door access control components to the door controller. f. All devices shall be homerun directly to the system / door controller. 7. LOCAL SOUNDERS a. Mount local alarm sounder as indicated on project drawings. b. Install local, square, and plumb. Set flush-mounted units so that the face of the cover, bezel, or escutcheon matches the surrounding finished surface. c. Mount so that there are no gaps, cracks, or obvious lines between the trim and the adjacent finished surface. d. All devices shall be homerun directly to the system / door controller. 8. SPARE PARTS a. The following spare parts shall be maintained on hand, by the integrator, for the length of the warranty period, with quantities specific to each project (fractions shall be rounded up to the nearest whole number): I. 5% of the total number of card readers installed II. 5% of the total number of reader interfaces of each type used III. (1) ISC of each type used IV. (10) of each type door position switch used V. 5% of the total number of Request-to-exit sensors used 6 P a g e

VI. VII. VIII. (1) spare power supply of each type used (1) spare Power distribution module (5) spare fuses of each type used 9. PACS INTEGRATION a. All intrusion functionality shall be monitored and controlled from within Alarm Monitoring in OnGuard. b. The Contractor shall perform all necessary programming in the PACS to accomplish this integration. c. If an area is armed, a code or authorized workgroup credential shall be required to disarm. d. When an area is armed, and someone enters the area the keypad shall audibly and visually indicate the entry warning signals. e. The system may be disarmed by presenting a valid PIN on the system keypad. f. The system may be armed or disarmed by presenting a valid authorized credential at a designated ARM/DISARM card reader located adjacent to the keypad. End of Section 7 P a g e