Uponor Comfort E AL-Foil Mat

Similar documents
CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

Royden. Look how easy it is to roll out the heat

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

WATCH OUT! UNDERNEATH THE WOODEN FLOORING IS A 230 VOLT HEATING FOIL SYSTEM! NEVER DRILL OR SCREW INTO THE FLOOR!

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

floor heating system

Underfloor Heating Cable Installation Manual

Underfloor Heating Mat Installation Manual

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Carbon Film Installation Instructions

emat Pro 100/150/200 Installation Manual

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

Underwood Heater Installation Manual

ELEKTRA RadiantFloor Heating

amuheat Cable Mat floor heating systems Installation Manual CM02-12

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1

Underlaminate Foil Heater

Underfloor Heating Inscreed Cable System

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Click & Plug Floor Heating. Installation instruction Devidry Kit

ELECTRIC HEATING THERMOSYSTEM

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

UNDERWOOD HEATING SYSTEM

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

Installation Instruction

Warm Feet For Uncoupling Membrane Pour membrane de désolidarisation. Installation Guide Floor Heating Cable

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

Electric Warm-Stretch under floor heating

Overview Frost Heave Prevention for Freezer floors on ground.

Intro. Intro. Table of Contents

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

Classic Mats Installation Manual

IdealFILM. Do-It-Yourself Installation Manual

Installation Instruction Devidry - for installation with Devidry Pro Kit

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

Self Regulating Trace Heating Systems Installation and Maintenance. Non-Hazardous Area Installations

HEATING USER GUIDE. Philex Support Line: Monday to Friday 9.00am to 5.00pm (Local rate - UK only)

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

F1202 TRACE HEATING. Road & Ramp

US: CA:

Always make sure to check the heating film before, during, and after installation of the floor covering.

Introduction. Please read the following instructions carefully before commencing installation.

Comfortline Ceiling Heating Foils INSTALLATION INSTRUCTIONS. Rev Mar-2016

Heating Mats. Single-side power supply Double-side power supply

Installation And User Instructions

Single-side powered heating cables

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

Installation Manual. Warmset. Warmset srl. Floor heating system

Underlaminate Foil Heater

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Installation Guide For your AHT Underfloor Heating System

FloorHeat Installation Manual

Installation Manual. Warmset. Warmset srl. Floor heating system

electric floor heating for everyone Heating mats Heating cables Temperature controllers

Documentation. Parallel Heating Cable. Type: ELP

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

electric floor heating Heating mats Heating cables Temperature controllers

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier

electric floor heating Heating mats Heating cables Temperature controllers

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Instructions for Operation and Maintenance of Containers

ELECTRIC UNDERFLOOR HEATING SYSTEMS. Operating Guide & Guarantee. The Underfloor Heating Specialists Tel:

HANDBOOK FOR COMFORTABLE WARM FLOORS

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

DOMOTHERM CLASSIC TWIN/S MAT

HEAT CABLE underfloor heating

amuheat Laminate Panel 14 floor heating systems Installation Manual LP12-V1

Under Carpet Heater Kit Installation Guide

EasyWire Between Joists Installation Instructions

Polymer solutions Heating mat EM2-CM

Installation and User Guides

INSTALLATION. For more information on this product or to order samples call or visit our website at builddirect.com.

Installation Guide - Heating Cables. Installation Guide. Heating cables. for In-Slab and In-Screed Applications BROCDEV135.1

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Hydronic Underfloor Heating

MONTAGE INSTRUCTIONS OF HEAT DECOR S HEATING FILM BELOW CONCRETE OR TILES

Snow melting for ramps, access ways, and footpaths

Water Underfloor Heating Kit

Foil Heating System. Installation Manual. for Carpet and Laminate TECHNICAL HELPLINE 0800 WARMUP ( )

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

How to install underfloor heating

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

Electrical Heating Solutions. Energy efficient building technology

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

Build on Uponor with Ecoflex Thermo PRO

Documentation. Glass -/quartz insulated Heating Cable. Factory terminated. Type: ELK-H, -HS, -Q ELW-H, -HS, -Q

TXLP Heating Cable Nexans Underfloor Heating. TXLP Nexans Underfloor Heating

Electric Under Floor Heating

Katherm NE - Natural convection with electric heating element 2.45

ATC Electric Under Floor Heating

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

Transcription:

Uponor Comfort E AL-Foil Mat

Contents Important notes on the intended use, safety and warranty...3 Intended use...3 Uponor Declaration of Warranty...3 System description...4 Floor construction...4 Technical specifications...4 Design data...4 Installation and commissioning...5 Installation instructions...5 Step by Step Installation...6 Commissioning...6 Uponor Comfort E installation and handover protocol...7 Installation images...8 Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous improvement and development. 02 l Uponor Comfort E AL-Foil Mat Installation Manual

Important notes on the intended use, safety and warranty Intended use Important safety instructions for installation Uponor Comfort E is an electric underfloor heating system that is used for heating rooms and tile warming. Installation should be conducted in accordance with local building regulations and laws. All installations must be carried out on sound subfloors by approved installers. Any other use apart from its intended purpose will void any manufacturing warranty. Uponor Declaration of Warranty for Comfort E AL-Foil Mat Obtain up to a 10-year warranty on the Uponor Comfort E system. This also covers any damages to the flooring during repair. The Uponor Declaration of Warranty is based on the confirmation that all Uponor products have been installed by an installation specialist in accordance with the relevant assembly instructions, in compliance with the relevant laws, regulations and the established rules of technology. How to obtain the Uponor Declaration of Warranty : 1. You must be an installation specialist, who has installed the appropriate Uponor system for which the Uponor Declaration of Warranty is to be issued. 2. The products are installed no more than 3 months ago. 3. Please ensure you have read and understood the "Uponor Declaration of Warranty" shown above. Following this, complete the "Uponor Comfort E Installation and Handover Protocol" found on page 7. The documents should be sent by e-mail (warranty.comfort-e@uponor.com) to Uponor. 4. Within a few working days, you will receive the original Uponor Declaration of Warranty. If Uponor products are assembled or mixed with third-party products within an installation, no Uponor Declaration of Warranty can be issued or it will lose its validity in retrospect. The heating mats may only be operated in combination with a room temperature thermostat with a fitted floor sensor. The heating mats must be connected to a 230 V mains voltage supply. A residual current circuit breaker with a tripping current of 30 ma has to be installed. When laying the heating mat, a distance of at least 60 mm to conductive building surfaces (such as water pipes) must be observed. The heating mats must not be laid underneath fixed furniture or sanitaryware, which stand directly and without feet on the floor in order to avoid overheating during operation. The heating cableass must not be passed through expansion joints or below insulation material. For the heating cables, a minimum bending radius of 30 mm must not be exceeded. The heating cables must not be kinked or otherwise damaged during installation. Crossing of the heating cables is not permitted. If several heating mats are installed in a room, they must only be connected in parallel to the mains voltage. Never connect in series! If several heating mats are installed on to one thermostat, please ensure the maximum current does not exceed 16 amps. The laying temperature must be at least 5 C. Attention! Risk of electric shock! The Uponor Comfort E electric floor heating is operated with a 230 V AC voltage. Connections to the power supply network must be carried out by a qualified electrician. Uponor Comfort E AL-Foil Mat Installation Manual l 03

System description Floor construction (Example) Technical specifications Technical specifications Uponor Comfort E AL-FOIL MAT Nominal voltage 230 V, AC Rated capacity 140 W/m 2 1 4 3 2 Circuit breaker 1) with C-Characteristics Min. bending radius Max. 16 A 30 mm 5 Min. installation distance 60 mm Max. operating temperature +90 C 6 Min. installation temperature +5 C 6 Conductor cross section of the connection cable Length of the connection cable 3 x 0,75 mm 2 3,0 m 1 Flooring (e.g. parquet, laminate) 2 Uponor Comfort E AL-foil mats (ca. 2 mm) 3 Uponor Comfort E AL-foil insulation board (5 mm) 4 Floor sensor in protective tube 5 Existing screed 6 Insulation layer with PE foil covering 7 Load-bearing substrate (e.g. concrete) Approvals CE and BEAB 1) When several heating mats are connected to a fuse box, the total connection current of the mats is limited to max. 16 A. Design data type Laying area (m 2 ) length (m) capacity (W) resistance 1 (Ω) UPONOR COMFORT E AL-FOIL MAT 140-1 1 2 140 378 UPONOR COMFORT E AL-FOIL MAT 140-2 2 4 280 189 UPONOR COMFORT E AL-FOIL MAT 140-3 3 6 420 126 UPONOR COMFORT E AL-FOIL MAT 140-4 4 8 560 94 UPONOR COMFORT E AL-FOIL MAT 140-5 5 10 700 76 UPONOR COMFORT E AL-FOIL MAT 140-6 6 12 840 63 UPONOR COMFORT E AL-FOIL MAT 140-7 7 14 980 54 UPONOR COMFORT E AL-FOIL MAT 140-8 8 16 1120 47 UPONOR COMFORT E AL-FOIL MAT 140-9 9 18 1260 42 UPONOR COMFORT E AL-FOIL MAT 140-10 10 20 1400 38 1) Tolerance -5% to +10% 04 l Uponor Comfort E AL-Foil Mat Installation Manual

Installation and commissioning Installation instructions General information The heating cables must not be shortened or come into contact with any other cables. It is not permissible to lay the heating cables over movement joints. The connection cable must be laid in a protective tube when crossing movement joints. No heating cables may be installed underneath floor standing sanitaryware. Likewise, the laying under fixed furniture without legs such as wardrobes is not allowed, as this can lead to overheating of the mat. Planning notes The existing floor must be structural, flat and free from damage. If necessary, the sub-floor must be levelled and or repaired for the installation of the Comfort E system. Before laying commences, the relevant standards and guidelines for the floor construction must be known and observed. Please note the warranty claim will be void if installed incorrectly. When planning, the position of the heating mats, the floor temperature sensor and the room temperature controller should be entered into the construction drawing. The arrangement of existing and future furnishings, such as floor-standing wardrobes, cabinets, etc., must be taken into account. Preparation of the substrate It is recommended to lay the Uponor Comfort E AL-foil underfloor heating on the Uponor Comfort E AL-foil insulation board. This will ensure maximum heat output of your system and reduce any step noise. If necessary, a PE foil should be laid above the insulation board to stop any ascending moisture. A direct laying of the electric floor heating on the existing surface without the Uponor Comfort E AL-foil insulation board is not recommended. Installation of room thermostat and floor temperature sensor For the installation of the room temperature thermostat, a 230 V AC power supply must be provided to a suitable location with an adequate sized backbox (minimum 35mm). From there, two protective tubes for the connection cable and the floor temperature sensor cable must be cut into the wall. The protective tube for the floor temperature sensor must also be installed in to the floor and finished flush with the surface of the Comfort E AL-foil insulation board. The heating mat connection cable and floor temperature sensor cable must not be installed in the same protective tube! If several heating mats are to be connected in parallel to the room temperature controller, a flush-mounted junction box must be installed. A residual current circuit breaker (30 ma) must be installed for safety. Separate instructions for the room temperature controller must be observed. Floor coverings The Uponor Comfort E AL-foil mat is designed for dry-laid flooring (e.g. parquet and laminate). The suitability of the chosen floor coverings must be checked by the respective manufacturer for use with electrical underfloor heating. In addition, any further specifications from the manufacturer have to be observed. In the area of the installed heating mats, no fixings may be inserted into the floor. Heat insulating floor coverings such as thick carpets are not permitted in areas where electric floor heating is installed, since this can lead to overheating. Important! The heating mats must not be shortened and must therefore be ordered in accordance with the room dimensions, taking into account any fixed furniture. Uponor Comfort E AL-Foil Mat Installation Manual l 05

Step by Step Installation 1. Compare the delivered materials with your order 2. Measure for any damage with a continuity test across the two conductor wires by placing one probe on the earth cable and the other on the live cable, looking for no continuity. Repeat this step with the neutral and earth cable. 3. Using a multimeter tester set to check for resistance, place one probe on the live cable and the second probe on the neutral cable, ensuring that it does not come into contact with the earth wire. Record the heating mat resistance in the Uponor Comfort E installation and handover protocol form and compare the values supplied with the mat. 4. Lay the Uponor Comfort E AL-foil insulation board onto a level and clean substrate. To protect the floor covering against ascending moisture, an additional PE foil on top of the insulation layer may be necessary. 5. Install the protective tubes, the back box and, if necessary, the junction box in the wall. Lay the sensor protective tube between two heating cables flush with the surface of the insulation boards. If necessary, the substrate has to be cut open. Insert the floor temperature sensor and the cable into the sensor protective tube. 6. Roll out the Comfort E AL-foil heating mats according to the layout plan. For change of direction, cut the aluminium foil of the underfloor heating mat with scissors, ensuring you do not sever the cable. Any joints should be covered using the supplied AL-foil tape. 7. Insert the cold cable through the protective tube into the flush-mounted back box or into the flush-mounted junction box and mark the cable ends of the respective heating mat. 8. Once the cable mat is installed, re-measure the continuity and resistance as per steps 2 and 3. 9. Enter the measured values into the enclosed Uponor Comfort E installation and handover protocol. 10. Once the test procedure has been completed, lay your desired flooring in accordance with the flooring manufacturer. 11. Following the laying of the floor covering, a final test is required in accordance with steps 2 and 3. Enter the measured values into the enclosed Uponor Comfort E installation and handover protocol. To receive the Uponor product warranty, all measurements must be documented in the Uponor Comfort E installation and handover protocol. This protocol has to be attached to the warranty request. 12. Connect the supply cable of the heating mats as well as the floor temperature sensor to the room temperature thermostat and connect it to the 230 V power supply. Observe the additional installation and operating instructions of the room temperature thermostat. Attention! Risk of electric shock! The Uponor Comfort E electric floor heating is operated with a 230 V AC voltage. Connections to the power supply network have only to be carried out by qualified electrician. Commissioning Carry out a function test by turning on the room temperature thermostat ensuring that the floor sufficiently heats. Please ensure the thermostat is set to a maximum floor temperature of 27 degrees. The heating system can now be handed over to the client or the user. In the handover you should include: The installation plan, on which the number and position of the individual heating mats (including the respective heating capacities) as well as the location of the junction boxes, the floor temperature sensor and the room temperature thermostat are located. The assembly and operating instructions. The Uponor Comfort E installation and handover protocol. The documents must be stored carefully and must be available at any time for warranty issues or changes to your system. Attention! In the area of the installed heating mats, no fixings may be inserted into the floor. 06 l Uponor Comfort E AL-Foil Mat Installation Manual

Uponor Comfort E installation and handover protocol* Building project / address Specialist for installation and 230 V connection Stick on product labels here Stick on product labels here Compare the values entered in the table below with the factory default values according to the table "Design data" Resistance and installation measurements Before laying the heating mats After laying the heating mats / Before laying the covering After laying the covering Room no. / designation Item no the heating mat resistance 1) (Ω) Installation resistance 2) (MΩ) resistance 1) (Ω) Installation resistance 2) (MΩ) resistance 1) (Ω) Installation resistance 2) (MΩ) 1) Tolerance -5% to +10% 2) Minimum installation resistance 10 MΩ The Uponor Comfort E electric underfloor heating has been professionally installed in accordance with the manufacturer's instructions, connected to the 230 V power network and handed over fully functional with the following documents: Installation and operating instructions Installation plan/ drawing Installation photos Comfort E installation and handover protocol Location, date Signature Contractor / qualified electrical installer Location, date Signature customer / building owner * To receive the Uponor product warranty, all measurements must be documented in the Uponor Comfort E installation and handover protocol. This protocol has to be attached to the warranty request. Uponor Comfort E AL-Foil Mat Installation Manual l 07

1 2 R =? Ω R =? MΩ 3 optional 4 1088707 A A 6 cm 6 cm STOP 08 l Uponor Comfort E AL-Foil Mat Installation Manual

5 6 R =? Ω R =? MΩ 7 8 R =? Ω R =? MΩ 230 V 50 Hz More information about Uponor Comfort E Uponor Comfort E AL-Foil Mat Installation Manual l 09

Uponor UK The Pavilion, Blackmoor Lane Watford Hertfordshire WD18 8GA 1090641_08/2017_MLD Uponor reserves the right to make changes, without prior notification, to the specification of incorporated components in line with its policy of continuous Producer: KAL improvement and development. 10 l Uponor Comfort E AL-Foil Mat Installation Manual www.uponor.co.uk