Operating Manual MS220VA and MSR220VA

Similar documents
Operating Manual MS220KA and MSR220KA

Operating Manual MS220Vi and MSR220Vi

Operating Manual MS220DA

Operating Manual MSF220V(VU)

Operating Manual TR600

Manual Isolating Barrier D461R1 (Revision 01)

Manual Isolating Barrier D461 (Revision 05)

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Overload Relay EMT6 Overload monitoring system for machines operating in the EEx e area

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

M LLET. Silo pressure detector. Füllstandtechnik. Operating instructions. 1. Description. 1.5 Dimensions. 1.1 Intended use. 1.

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

PROTECT SRB 200EXi-1A

Physikalisch-Technische Bundesanstalt

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

OPERATING MANUAL RAY-NC 1000 SERIES

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Operating Guide Safe Torque Off

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

DTA. Motor thermistor relay. Benefits. Description

ISIS SAFETY SYSTEM Installation guide

Operating Instructions VLT PTC Thermistor Card MCB 112

DTA04. Motor thermistor relay. Benefits. Description

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Inductive slot sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Manual Power relay SR853

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

Datasheet - MZM 100 ST-SD2PREM-A

Technical Data. Dimensions

Datasheet - MZM 100 B ST2-SD2PREM-A

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Instructions for the fan motor control system, SILVER C

Datasheet - MZM 100 ST2-1P2PWREM-A

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Proservo NMS5- / NMS7-

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

DICTATOR Hold-Open Systems for Hazardous Areas

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

MANUAL Overflow sensor NVF-104/34-PF

Technical Data. Dimensions

RE-PR3-E-27 3-Phase Panel Mount 27kW

Liquiphant S, Nivotester FDL60/61, FTL670

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

GESTRA Steam Systems NRS English. Installation Instructions Level Switch NRS 1-51

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Soliphant M with electronic insert FEM52

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

UV Flame Supervision System

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Remote alarm indicator and test combination MK2430

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Original instructions Sense7-series Non-contact coded safety switch

1.7. Insulation fault evaluators EDS460/490 EDS461/491

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Operating Guide Safe Torque Off

SensaGuard TM Integrated Latch Installation Instructions

PolyGard 2-channel Gas Controller MGC-03

BES M30EP-PFC12F-S04G-D12 BES Q40ZU-PFC15B-S04G-D12 BES Q40ZU-PFC20F-S04G-D12 Inductive Safety Sensors User's Manual

OPERATING INSTRUCTIONS. for the heat press. Secabo TPD7

Gas cylinder scale Model GCS-1

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Drive systems for the chemical, oil and gas industry. Electric drives and systems

OPERATING INSTRUCTIONS. for the heat press. Secabo TC D7

QFM21... Duct sensors. Symaro. for relative humidity and temperature

MANUAL Oil Level Sensor

LAE10 LFE10. Use. Series 02

Instruction Manual. Electronic gas and smoke detector GRM

OPTISENS TUR 2000 Technical Datasheet

Flame Safeguards LFE10. Building Technologies HVAC Products

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

OPTIBAR DP 7060 Supplementary Instructions

SCHMIDT LED Measured Value Display MD Instructions for Use

C Note! LGI16... Burner Controls. Building Technologies

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

Temperature Sensor TRG Original Installation Instructions English

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Transcription:

ZIEHL industrie elektronik GmbH + Co KG Daimlerstr.13, 74523 Schwäbisch Hall, Germany + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panelmeters MINIPAN Switching Relays and Controls Measuring Transducers Grid- and Plant Protection Operating Manual MS220VA and MSR220VA updated: 2019-02-06/Su PTC thermistor relay with short-circuit detection Marking see type plate on the device - type examination certificate PTB 12 ATEX 3006 MS220VA and MSR220VA 11660-0701-03-GB Page 1 / 12 www.ziehl.de

Table of contents 1 General Notes... 3 2 Display- and control elements... 3 3 Pre-Adjustment... 3 4 Application and brief description... 3 5 Summary of features... 4 6 Connecting diagram... 4 7 Function diagram... 5 8 Important Notes... 5 9 Installation... 5 10 Commissioning... 6 11 Operating instructions... 6 12 Trouble shooting and remedies... 6 13 Technical data... 6 14 Dimensions - Design V2... 8 15 Safety Instructions and references for putting into operation... 8 15.1 Special remarks for explosive gas atmospheres areas (Zone 0, Zone 1 and Zone 2)... 8 15.2 Special remarks for use in the presence of combustible dust! (Zone 20, Zone 21 and Zone 22)... 9 15.3 Safety characteristics of the safety device... 9 15.4 Category and Performance-Level (EN ISO 13849-1)... 9 15.5 Application of the safety device used with equipment category (EN 50495/VDE 0171-18)... 9 15.6 Wiring... 10 15.7 Safe Separation... 10 15.8 Stop function... 10 15.9 Start and Restart... 10 15.10 Manual resetting... 10 16 Proof testing of the safety functions... 11 17 Maintenance and repair... 11 18 EU-Declaration of conformity... 12 MS220VA and MSR220VA 11660-0701-03-GB Page 2 / 12 www.ziehl.de

1 General Notes Compliance with the following instructions is mandatory to ensure the functionality and safety of the product. If the following instructions given especially but not limited for general safety, transport, storage, mounting, operating conditions, start-up, maintenance, repair, cleaning and disposal / recycling are not observed, the product may not operate safely and may cause a hazard to the life and limb of users and third parties. Deviations from the following requirements may therefore lead both to the loss of the statutory material defect liability rights and to the liability of the buyer for the product that has become unsafe due to the deviation from the specifications. 2 Display- and control elements 1 = LED red ALARM 2 = LED green Power ON 3 = built-in key button Reset 3 Pre-Adjustment No settings are necessary on the devices. The tripping temperature is determined solely by the response temperature of the connected PTC thermistors. Depending on the number of PTC thermistors the following tripping temperatures and reset temperatures arise related to TNF (detector operating temperature): Tripping temperature Reset temperature 1 PTC thermistor TNF + 15 K TNF + 5 K 3 PTC thermistors in series TNF + 5 K TNF 5 K 6 PTC thermistors in series TNF TNF 20 K 4 Application and brief description Ziehl PTC thermistor relays protect motors, transformers, machines and equipment against thermal overload. Used in conjunction with respective PTC thermistors they provide a reliable temperature protection in the temperature range 60 C up to 180 C. MS220VA and MSR220VA 11660-0701-03-GB Page 3 / 12 www.ziehl.de

ZIEHL PTC thermistor relays are conform to EN 60947-8 and are thus exchangeable. PTC-thermistors according DIN 44081 and DIN 44082 shall be connected. PTC thermistors are suitable for the installation into windings of electrical machines, bearings and transformers as well as to monitor the temperature of liquid media, airflow and gases. With ATEX approval, explosion-protected equipment in explosive gas atmospheres (marking G: gas) or in areas with combustible dust (marking D: dust) can be protected. 5 Summary of features 1 thermistor circuit for 1 6 PTC thermistors Short-circuit detection within the thermistor circuit Output relay with 1 change-over contact (co) Operating status display with LED A current monitors continuously the resistance of the sensors. In cold state, the resistance is <250 Ω per sensor (sensor circuit < 1.5 kω). The relay has picked up and contacts 11/14 are closed. The resistance of the thermistor rises rapidly at detector operating temperature TNF. The relay release at a resistance of 3 4 kω and contacts 11/12 close. The devices also switch off in the case of detector or line short-circuit (< approx. 20Ω) or detector or line interruption. MS types switch on automatically when the temperature has decreased approx. 5 C. MSR types store the switch-off and must be reset (to be acknowledged) manually with the builtin key button or an external push-button. Power-on is recognized as an automatic reset. With bridged terminals Y1 and Y2, the function reclosing-lock is disabled. Then the device works like type MS. 6 Connecting diagram Us = supply voltage S1 = off-switch S2 = push-button on S3 = remote reset only MSR type H1 = indicator lamp fault F1-F4 = fuses K1 = contactor PTC = PTC thermistor MS220VA and MSR220VA 11660-0701-03-GB Page 4 / 12 www.ziehl.de

7 Function diagram MS220VA (automatic reset) MSR220VA (reclosing lock) Caution! The released relay switches on automatically after a voltage dip. 8 Important Notes Attention! Observe safety rules and standards. Notice safety remarks! DANGER! Hazardous voltage! Will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device! 9 Installation The applicant must observe safety rules and standards. The device can be mounted on 35 mm rail according EN 60715 or with screws M4 (Option) The devices must be installed in a closed switchgear cabinet or in an enclosure of international protection class IP 5x according EN 60529 or better. Terminals with screw mounting M3 maximum tightening torque 0,5 Nm MS220VA and MSR220VA 11660-0701-03-GB Page 5 / 12 www.ziehl.de

When installing the device into the switchgear cabinet, please observe the max. admissible temperature. Care for both, sufficient clearance to other devices or sources of heat or enough forced draught. If cooling is made more difficult, e.g. close devices with increased surface temperature or by handicap of airflow cooling, the permissible ambient temperature has to be reduced. 10 Commissioning Attention! Before switching on make sure that the operational voltage Us of the Type plate and the mains voltage are the same! After the supply voltage is switched on and when the thermistors are correctly connected the green LED ON must light-up and the relay contacts 11,14 close. The correct function of the tripping device must be checked by resistance simulation at terminals T1 and T2. This check is also performed after changes to the installation. 11 Operating instructions MSR220VA devices have an built-in reset button and can be manually reseted after a fault signal (Red = alarm). For this purpose, also an external button (remote reset terminal Y1, Y2) can be used. Terminals Y1 and Y2 may be bridged so the function reclosing-lock is disabled. 12 Trouble shooting and remedies Relay does not pick up. Please check: The supply voltage Us at terminals A1-A2 (green LED lights-up). The PTC s at terminals T1-T2. In the case of disturbance the red LED lights-up. The resistance of a PTC circuit must be at 50 Ω < R < 1500 Ω. The terminal voltage T1-T2 is to be measured < 2.5 Vdc with connected PTC. MSR type: please push the key button Reset. The relay can pick up at resistance R < 1.65 kω and the light changes from red to green. Alternatively reset can be done with closing an external contact at terminals Y1-Y2 or with voltage recovery. Relay does not release. Please check: With no PTC sensor connected the relay must release. The voltage at terminals T1-T2 must be approx. 8 V. In case of any other malfunctions, replace device. Please add a description of the occurred malfunction when sending back for repair. 13 Technical data Power supply (A1, A2) Rated supply voltage Us: (see type plate on the device) AC 48 V AC 110-120 V, AC 220-240 V, AC 380-415 V AC / DC 24 V (ohne Potenzialtrennung) Tolerance of voltage Us AC 0.9 Us 1.1 Us DC 21... 30 V Frequency (AC) Tolerance of frequency 50 / 60 Hz 45 Hz 65 Hz Power consumption < 2 VA < 2 W On-period 100 % Voltage dip buffer time Max. 20 ms MS220VA and MSR220VA 11660-0701-03-GB Page 6 / 12 www.ziehl.de

Thermistor input (T1, T2) PTC - Sensor acc. DIN 44081 and DIN 44082 Number 1... 6 PTC thermistor in series Rated response temperature TFS 60 C 180 C Response tolerance +/- 6 C Collective resistance cold thermistor 1.65 kω Terminal voltage (PTC thermistor) 2.5 V at R 3.65 kω, 2 V at R 1.65 kω 9 V at R = Terminal current (PTC thermistor) < 1 ma Power consumption < 2 mw Line capacity max. 0,2 µf Temperature monitor cut-out-point 3.3 kω 3.65 kω 3.85 kω Temperature monitor reclosing point 1.7 kω 1.8 kω 1.95 kω Short circuit monitor cut-out-point 20 Ω Short circuit monitor reclosing point 40 Ω Reset input (Y1, Y2) Current Voltage Potential free contact (no) 1 ma < 30 Vdc Relay output (11,12,14) EN 60947-5-1 Contacts 1 change-over contact (co) Rated operational voltage Ue 250 V Switching voltage/current Max AC 415 V /5 A Min 12 V /10 ma Switching power max. (ohm resistive load) 1250 VA 120 W at DC 24 V Rated operational current (Ie) AC15 Ie = 3 A Ue = 250 V DC13 Ie = 2 A Ue = 24 V Recommended fuse 4 A (gg Mechanical contact life 3 x 10 7 operations Electrical contact life 1 x 10 5 operations at 240 V / 6 A UL electrical ratings 250 V ac, 3 A, general use 240 V ac, 1/4 hp, 2.9 FLA 240 V ac, 1/4 hp, 2.9 FLA 120 V ac, 1/10 hp, 3.0 FLA C 300 Electrical Safety - Testing conditions IEC/EN 60947 Contacts 1 change-over contact (co) Rated insulation voltage Ui 300 V Rated impulse voltage 4000 V Overvoltage category III Contamination level 3 Transformer EN 61558-2-6 Proof Test Voltage 2500 VAC 50 Hz EMC - Immunity EN 61000-6-2 EMC - Emission EN 61000-6-3 Installation conditions Fitting position any Rated ambient temperature range -20... +55 C Storage Temperature range -10 +70 C (1K3 EN60721-3-1) Alltitude 2000 m above see level Climatic conditions 5-85% rel. F, no condensation (3K3 EN 60721-3-3) Vibration resistance EN 60068-2-6 2 13.2 Hz ± 1 mm 13.2... 100 Hz ± 0,7 g MS220VA and MSR220VA 11660-0701-03-GB Page 7 / 12 www.ziehl.de

3 61,8 45 (90) 98 116 Housing Design V2 Dimensions (H x W x D) mm 90 x 35 x 58 Plastic Material PA66 Fire protection class UL 94 V-2 Protection class housing EN 60529 IP 30 Mounting EN 60715 standard rail 35 mm Optional: Screw mounting M4, only with additional bolt (not part of delivery) Protection class terminals EN 60529 IP 20 Tightening torque 0.5 Nm Line connection solid wire 1 x 0.5...2.5 mm 2 (AWG 22 14) Stranded wire with insulated ferrules 1 x 0.14 mm 2 1.5 mm 2 Insulation strip length min. 8 mm Weight approx. 117 g Subject to technical modifications 14 Dimensions - Design V2 Dimensions in mm 58 48 16,5 Option 35 5 4 1 Top 2 Bottom 3 Bolt 4 Seal mounting link 1 2 3 5 Front plate element 6 Characteristic for bottom 7 Extensible bolt for wall fastening with screws. Bolt bore Ø 4.2 mm. 6 7 15 Safety Instructions and references for putting into operation please read carefully! 15.1 Special remarks for explosive gas atmospheres areas (Zone 0, Zone 1 and Zone 2) The increased danger within hazardous areas requires the careful attention of the safety instructions and references for putting into operation. Observe the national safety rules and regulations for prevention of accidents as well as the European Standard EN 60079-14. All work for the connection, for putting into operation and maintenance is to be implemented by qualified, responsible technical personnel. Inappropriate behaviour can cause heavy personal damage and damages to property. The response of the thermal motor protection must directly switch off the motor, also when used together with converters. This must be realized in the logic section or configuration in the converter. MS220VA and MSR220VA 11660-0701-03-GB Page 8 / 12 www.ziehl.de

The tripping device may be installed only outside potentially explosive atmospheres for the protection of explosive-protected motors. When used in potentially atmospheres, the device must comply with the required type of protection. 15.2 Special remarks for use in the presence of combustible dust! (Zone 20, Zone 21 and Zone 22) The increased danger within hazardous areas of combustible dust requires the careful attention of the safety instructions and references for putting into operation. Observe the national safety rules and regulations for prevention of accidents as well as the European Standard EN 60079-14. Installation, electrical connection and commissioning to be carried out by trained service personnel only. Inappropriate behaviour can cause heavy personal damage and damages to property. The tripping device may be installed only outside potentially explosive atmospheres for the protection of explosive-protected motors. When used in potentially explosive atmospheres, the device is to be provided with a dust proofed enclosure according EN 60529. 15.3 Safety characteristics of the safety device Safety Integrity Level (EN 61508) and safety related parameters Operating mode Hardware architecture HFT Safety Integrity Level low demand mode 1001 0 SIL 1 Type MTBF PFH SFF SD SU DD DU MS220VA 54 years 4.07E-07 55% 4.44E-07 5.55E-08 0 4.07E-07 MSR220VA 52 years 4.26E-07 55 % 4.52E-07 6.10E-08 0 4.26E-07 Type Proof test interval T1 1year 3 years 5 years 10 years MS220VA PFDavg 1.78E-03 5.35E-03 8.91E-03 1.78E-02 MSR220VA PFDavg 1.87E-03 5.60E-03 9.33E-03 1.87E-02 Observe proof test interval according EN 60079-17 for electrical equipment 3 years. 15.4 Category and Performance-Level (EN ISO 13849-1) The devices fulfil the requirements of category 1 and PL = c. MTTF d = 100 years. The data of the functional safety stated above are valid for an ambient temperature of 40 C. Data for additional ambient temperatures can be obtained on request. 15.5 Application of the safety device used with equipment category (EN 50495/VDE 0171-18) This standard describes the minimum requirements of safety integrity level and fault tolerance of a safety device in the application together with the category of the Equipment Ander Control (EUC). EUC Category 2 (2G, 2D) EPL = Gb, Db Category 3 (3G, 3D) EPL = Gc, Dc Safety device no safety device SIL 1 SIL 2 Zone 1, Zone 21 Zone 0, Zone 20 Zone 0, Zone 20 Zone 2, Zone 22 Zone 1, Zone 21 Zone 0, Zone 20 The tripping relay thus is suitable as safety device for Equipment Under Control (EUC) Category 3 (HFT = 0) in Zone 1 and Zone 21 and for Equipment Under Control (EUC) Category 2 (HFT = 1) in Zone 0 and Zone 20. The combined equipment shall comply with the relevant standards EN 60079-0 respectively EN 61241 according to the categories to match. MS220VA and MSR220VA 11660-0701-03-GB Page 9 / 12 www.ziehl.de

15.6 Wiring The lines of the thermistor circuit are to be routed as separate control lines as far as to the motor line. The use of lines of the supply cable or other mainstream lines is not permissible. If extreme inductive or capacitive stray effects are to be expected by parallel cables of the power installation, shielded control lines should be used. Used with electronic speed regulation the thermistor lines must be routed separately from the power lines as far as to the motor line, in order to avoid EMC distortion and thus false signal release. With devices type MSR the terminals Y1, Y2 may be attached parallel to a common resetting mechanism. Sensor lines may not be connected together. The line resistance within the sensor circuit may not exceed a value of 20 Ω. Maximum of permissible length for sensor circuit lines: Wire cross section Wire length 2,5 mm 2 2 x 1000 m 1,5 mm 2 2 x 800 m 1,0 mm 2 2 x 500 m 0,75 mm 2 2 x 300 m 0,5 mm 2 2 x 250 m With commissioning and after modification of the plant the sensor resistance must be checked with a suitable measuring instrument. With a resistance < 50 Ω the sensor circuit is to be examined for shortcircuit. 15.7 Safe Separation Attention! Check PTC s only with measuring voltages of < 2.5 V. Line circuits (A1, A2, 11, 12, 14) have a safe separation to low-voltage electric circuits (T1, T2, Y1, Y2). Trip relays with supply voltage DC/AC 24 V are permissible only at power supplies according EN 61558-2-6 where protected wiring is used. 15.8 Stop function A stop function released by the protection device must transfer the machine after manipulation of this function as fast as possible into a safe condition. The stop function must have top priority. In case of failure the relay switches off the contactor/circuit breaker and so prevents an overheating of the isolation system and/or the surface temperature. The protective function of the equipment is guaranteed only if wiring is done directly into the control circuit of the motor/machine in accordance with the connection diagram. The contacts must be protected, in order to prevent welding. 15.9 Start and Restart A restart may take place automatically only if no dangerous condition can be present. The tripping devices of types MS 220 are equipped with an automatic reset function. For this device design, suitable wiring of the control units must be ensured to prevent automatic restarting of the explosiveprotected motor of the type of protection Increased Safety e in case of failure. 15.10 Manual resetting After introducing a stop instruction by the protection device this must be maintained, until the manual resetting mechanism is operated and safe conditions for a renewed start are given. The manual resetting may be only possible, if all safety functions and protection devices are effective. Trip devices types MSR have an electronic reclosing lock. The stop instruction remains, until by pressing the push-button Reset a reset is made. A start-up is only possible, if no case of failure occurs and the motor is cooled down to a sufficient value of temperature. Trip devices type MSR 220VA switch on automatically with return of supply voltage. The user must guarantee by external interlock (see connection diagram) so the supervised motor/machine does not start again independently. MS220VA and MSR220VA 11660-0701-03-GB Page 10 / 12 www.ziehl.de

Attention! Safety circuits according to EN 60204/EN 62061. The tripping devices must not be used alone for functions, where an automatic Restart must be prevented. 16 Proof testing of the safety functions The safety function shall be tested at regular intervals. It is recommended to carry out the proof-test once a year. Depending on the zone risk, tests should be conducted more frequently. A fault is recognized by the safety test. A fault between safety tests could cause loss of protection. The safety function must be tested by interrupt the thermistor circuit wire at terminals T1, T2. The short circuit monitoring function must be tested by bridging the thermistor circuit wires at terminals T1, T2. The safety function must be tested by changing the resistance from 1500 Ohm to 4000 Ohm at terminals T1, T2. The function of the electronic interlock must be tested additionally. If an error is detected no restart must be induced until the error is cleared. 17 Maintenance and repair The devices are maintenance-free. Only the manufacturer may accomplish repairs. We recommend testing within the regular maintenance intervals of the plant, where the device is used. EN 60079-17 is to be observed. You ll find this and other user manuals in the internet under www.ziehl.com ZIEHL industrie elektronik GmbH + Co KG Daimlerstr. 13 74523 Schwaebisch Hall Germany Fon + 49 791 504-0 info@ziehl.de www.ziehl.de MS220VA and MSR220VA 11660-0701-03-GB Page 11 / 12 www.ziehl.de

18 EU-Declaration of conformity EU-Declaration of Conformity Erklärung/Declaration No. 11665-1300-02 Hersteller: Manufacturer: Anschrift: Address: Produktbezeichnung: Product specification: Ziehl industrie-elektronik GmbH + Co KG Daimlerstr. 13 74523 Schwäbisch Hall Germany Kaltleiter-Relais PTC Thermistor Relay Typ: Type: MS220VA MSR220VA MSR220VA T222415 T222431 T222435 Wir erklären in alleiniger Verantwortung, dass oben bezeichnetes Produkt den grundlegenden Anforderungen entspricht die in den folgenden Europäischen Richtlinien festgelegt sind: We declare under our sole responsibility that above designated product meets the basic requirements and complies with the following directives of the European Union: Angewandte harmonisierte Normen und technischen Spezifikationen: Applied harmonised standards and technical specifications: Benannte Stelle und Nummer der EG- Baumusterprüfbescheinigung: Notified Body and number of the EC-typeexamination certificate: Schwäbisch Hall, 30.01.2019 Ort, Datum der Ausstellung Place, date of issue 2014/35/EU Niederspannungsrichtlinie Low Voltage Directive 2014/30/EU EMV Richtlinie EMC Directive 2014/34/EU ATEX Richtlinie ATEX Directive 2011/65/EU RoHS Richtlinie 2015/863/EU RoHS Directive EN 60947-8:2003 + A1:2006 + A2:2012 EN 61000-6-2:2005 + AC:2005 EN 61000-6-4:2007 + A1:2011 EN 50495:2010 EN 50581:2012 PTB Physikalisch Technische Bundesanstalt 0102 PTB 12 ATEX 3006 CE-Kennzeichnung: 2012 CE marking in: ppa. Herbert Wahl Verkaufsleitung i.v. Bernhard Scheu Qualitätsmanagement MS220VA and MSR220VA 11660-0701-03-GB Page 12 / 12 www.ziehl.de