Performance of the Variable Refrigerant Volume Air-Conditioning System. with Heat Recovery

Similar documents
Design and Research of the Digital VRV Multi- Connected Units With Three Pipes Type Heat Recovery System

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Effect of Height Difference on The Performance of Two-phase Thermosyphon Loop Used in Airconditioning

Application of the VRV Air-Conditioning System Heat Recovery Series in. Interior Zone and Analysis of its Energy Saving

Purdue e-pubs. Purdue University

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

A study of Transient Performance of A Cascade Heat Pump System

Review of Temperature and Humidity Control Technology for Heat Pump and Air Conditioning Systems

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Adsorption refrigeration system using waste heat

Design and Research of the Commercial Digital VRV Multi-Connected Units With Sub-Cooled Ice Storage System

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Hunting Phenomena Of Automotive Air Conditioning Systems With Variable Displacement Compressor

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

APPLICABILITY OF VRV/VRF HVAC SYSTEM A JUDICIOUS AND RATIONAL APPROACH

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Experimental Study About An Amount Of Oil Charge On Electric Driven Scroll Compressor For Electric Vehicle

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Review of Temperature and Humidity Control Technology for Air Conditioning and Heat Pump Systems Paper 2386

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

EXPERIMENTAL INVESTIGATION ON VARIABLE SPEED OPERATION OF AIR CONDITIONING

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Possibilities of Heat Exchanger Use in Pigsty Ventilation Systems

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance of an Improved Household Refrigerator/Freezer

Performance Characteristic and Optimization of a Simultaneous Heating and Cooling Multi Heat Pump

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Modelling the Performance of a Diffusion Absorption Refrigeration System

International Journal of Informative & Futuristic Research ISSN (Online):

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Variable refrigerant flow (VRF) systems

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

The Innovative Green Technology for Refrigerators Development of Innovative Linear Compressor

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

High-efficiency Turbo Chiller (NART Series)

PERFORMANCE MONITORING OF A HIGH-TEMPERATURE AIR-TO-WATER HEAT PUMP WITH INJECTION CYCLE INSTALLED IN A LOW-INSULATED SINGLE-FAMILY HOUSE IN BELGIUM

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

Study of R161 Refrigerant for Residential Airconditioning

,Chaojian He6, f. School of Guangxi University, Nanning , China.

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Variable Refrigerant Flow (VRF) Systems

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Experimental Study on the Performance and Oil Return Characteristics of Multi-Split Air- Conditioning System for Medium Size Building

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

A New Dedicated Outdoor Air System with Exhaust Air heat recovery

An improved Algorithm of Generating Network Intrusion Detector Li Ma 1, a, Yan Chen 1, b

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

ADVANCED TRAINING INSTITUTE, HYDERABAD PR04/F01

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Performance Characteristics of a Refrigerator- Freezer with Parallel Evaporators using a Linear Compressor

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

High efficient heat pump system using storage tanks to increase COP by means of the ISEC concept - Part 1: Model validation

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Department of MCE, Islamic University of Technology 2. Abstract

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Experimental Study on Crawl-Space Heating with Thermal Storage using Heat Pump

Performance of CO2 Cycles with a Two-Stage Compressor

Full and Partial Load Performances of RAC and CAC Heat Pump using R-32

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Diagnosing Troubles in Refrigeration Units with Screw Compressors

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

Cost-Effective COP Enhancement of a Domestic Air Cooled Refrigerator using R-134a Refrigerant

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Modified Air Cooler with Split Cooling Unit

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

Efficiency of Non-Azeotropic Refrigerant Cycle

Global Journal of Engineering Science and Research Management

GAS FREE REFRIGERATOR USING PELTIER MODULE

Transcription:

Performance of the Variable Refrigerant Volume Air-Conditioning System with Heat Recovery Shi Wenxing, Postdoctor, Department of Thermal Engineering, Tsinghua University, Beijing, China, Wenxingshi@263.net.cn Shao Shuangquan, Doctor Candidate, Department of Building Science, Tsinghua University, Beijing, China, Shaoshq99@mail.tsinghua.edu.cn Wang Baolong, Doctor Candidate, Department of Building Science, Tsinghua University, Beijing, China, Wangbaolong00@mails.tsinghua.edu.cn Li Xianting, Associate Professor, Department of Building Science, Tsinghua University, Beijing, China, Xtingli@mail.tsinghua.edu.cn Yan Qisen, Department of Building Science, Tsinghua University, Beijing, China ABSTRACT Different rooms in the same building have disparate heat/cool load because of diverse orientation and different indoor heat sources. Some rooms need to be cooled while the others need to be heated. Conventional multi-system air-conditioners are limited to cool all of the indoor units or heat all of them. The common multi-system air-conditioners can not satisfy all of the users. A multiple variable refrigerant volume (VRV) air conditioning system with heat recovery has been developed in this paper. A suitable operating mode can be selected for each indoor unit independently in this system, hence, concurrent heating and cooing is possible. This paper describes the configuration, basic operating methods, and experimental results indicated a maximum one times higher coefficient of performance (COP) in the current heating and cooling mode compared to single-mode operations. INTRODUCTION With the development of national economy and the improvement of living standard, the requirement of air conditioner increases very quickly to make a comfortable environment for living and working. Some multi-system air conditioners have been developed to satisfy the need of several rooms (M.Masuda 1991, Gu Bo 1995). However, their operation is limited to a single mode--heating or cooling--at one time. The energy problem is urgent so that the performance of air conditioners must be improved. Thus, variable frequency compressor and EEV (Electronic Expansion Valve) are widely used (T.Q. Quieshi 1996, Shi Wenxing 2000). And some new Multi air conditioning systems were developed (Shi Wenxing 2000, Shao Shuangquan, 2001). With the development of air conditioning technology, air conditioner is developed from the viewpoint of decreasing the energy consumption and increasing the human comfort. In modern buildings, some rooms need to be cooled, but some other rooms need to be heated simultaneously, even some rooms need not to be cooled or be heated, so the indoor units may be 924

act as evaporators or condensers or be closed at the same time. Traditional air-conditioning system can only satisfy all the room to be cooled or be heated at the same time. A new multiple VRF air conditioning with heat recovery has been developed in this paper. This system consists of several indoor units and one outdoor unit. Its capacity responds to the load of each room by using an inverter-aided compressor and electronic expansion valves that can automatically control the refrigerant flow for each indoor unit. The indoor unit in the heating room acts as condenser and the indoor unit in the cooling room acts as evaporator while the outdoor unit may act as evaporator or condenser. Because both the condensing heat and evaporating heat are valuable in use, while in the traditional systems only the condensing heat or evaporating heat can be used, the energy efficiency ratio of this system is increased greatly and the capacity and energy consumption of outdoor unit is decreased remarkably. A typical system with two indoor units is analyzed based on the thermodynamics theory and computer simulation. Compared with the traditional air conditioning system, this system which provides higher human comfort with lower energy consumption can be used in the residential buildings or commercial buildings and can run in the heat pump mode, refrigeration mode or heat recovery mode throughout the year. CONFIGURATION AND OPERATING MODES The new multiple VRF air conditioning system consists of one outdoor unit and two indoor units. The configuration and the basic refrigerant circuit of this system are illustrated in Figure 1. This System has five different modes, as recovery. Each operating mode is discussed below. Cooling-Only Mode Figure 1 Configuration of the VRF system follows: 1. Cooling-only mode: All working indoor units are in the cooling operation; 2. Heating-only mode: All working indoor units are in the heating operation; 3. Cooling-principal mode: Cooling is the principal mode in the concurrent heating and cooling operation; 4. Heating-principal mode: Heating is the principal mode in the concurrent heating and cooling operation; 5. Heat recovery mode: heat balance between two indoor units and the outdoor heat exchanger does not work. This VRF system has five operating modes, cooling-only, heating only, cooling-principal, heating-principal, and heat In this mode, the indoor units (for example, A and B) are in cooling operation, as shown in Figure 2. The 925

gas refrigerant discharged from the compressor flows into the outdoor heat exchanger through connecting pipe and is condensed there. The liquefied refrigerant flows into the indoor units through connecting pipe and is depressurized by the indoor EEVs. The depressurized refrigerant is evaporated in the indoor heat exchangers and returns to the compressor through connecting pipe. Thus, the indoor heat exchangers work as evaporators, and the outdoor heat exchanger works as a condenser. Figure 2 Cooling-Only mode Figure 3 Heating-Only mode Heating-Only Mode In this mode, the indoor units (for example, A and B) are in heating operation, as shown in Figure 3. The gas refrigerant discharged from the compressor flows into the indoor heat exchangers through connecting pipe and is condensed there. The liquefied refrigerant from each indoor heat exchanger flows into the outdoor unit through connecting pipe and is depressurized by the outdoor EEV. The depressurized refrigerant is evaporated in the outdoor heat exchanger and returns to the compressor through connecting pipe. Thus, the indoor heat-exchangers work as condensers, and the outdoor heat exchanger works as a evaporator. Cooling-Principal Mode In this mode, for example, indoor unit B is in cooling operation and indoor unit A is in heating operation. As shown in Figure 4, the gas refrigerant discharged from the compressor flows into the outdoor heat exchanger and the indoor heat exchanger A through connecting pipe and is condensed there. The liquefied refrigerant from the outdoor heat exchanger and the indoor heat exchanger A flows into the indoor unit through connecting pipe and is depressurized by the indoor. The depressurized refrigerant is evaporated in the indoor heat exchanger B and returns to the compressor through connecting pipe. Thus, the outdoor heat exchanger and the indoor heat exchanger A work as condensers, and the indoor heat exchanger B works as a evaporator. 926

Figure 4 Cooling-Principal mode Figure 5 Heating-Principal mode Heating-Principal Mode In this mode, for example, indoor unit A is in cooling operation and indoor unit B is in heating operation. As shown in Figure 4, the gas refrigerant discharged from the compressor flows into the indoor heat exchanger B through connecting pipe and is condensed there. The liquefied refrigerant from the indoor heat exchanger B flows into the indoor unit A and the outdoor unit through connecting pipe and is depressurized by the indoor and. The depressurized refrigerant is evaporated in the indoor heat exchanger A and the outdoor heat exchanger and returns to the compressor through connecting pipe. Thus, the outdoor heat exchanger and the indoor heat exchanger a work as evaporators, and the indoor heat exchanger B works as a condenser. Heat Recovery Mode In this mode, for example, indoor unit B is in cooling operation and indoor unit A is in heating operation. As shown in Figure 2e, the gas refrigerant discharged from the compressor flows into the indoor heat exchanger A through connecting pipe and is condensed there. The liquefied refrigerant from the indoor heat exchanger A flows into the indoor unit B Figure 6 Heating-Recovery mode through connecting pipe and is depressurized by the indoor. The depressurized refrigerant is evaporated in the indoor heat exchanger B and returns to the compressor through connecting pipe. Thus, the indoor heat exchanger A work as a condenser, and the indoor heat exchanger B works as an evaporator and the outdoor heat exchanger does not work. The heat is transmitted from the room B to the room A. 927

ANALYSIS OF PERFORMANCE From the analysis, we can find both the condensing heat and evaporating heat are valuable in use in the mode such as cooling-principal, heating-principal and heat recovery. The coefficient of performance (COP) of the VRF system increases markedly. The COP can be calculated by the following equation: Q Q COP P where A B (1) QA -----heat exchanged in indoor unit A, (W) QB -----heat exchanged in indoor unit B, (W) P -----electricity energy consumed by the system. (W) When the indoor unit is in heating operation, the heat exchanged in it is positive number, and when the indoor unit is in cooling operation, the heat exchanged in it is negative number. 2.5 2 1.5 1 0.5 6000 5000 4000 3000 2000 1000-1000 -2000 Fz W CO P 0-6000 -3000 0 Q(W) 3000 6000 0 QA + QB QA W Fz CO P -3000-6000 -3000 0 3000 6000 QB The value of each variable is shown in Table 1 when the system is operating in standard condition. Taking the value of P, Fz and COP in this condition for one, the ratios of them in other conditions are shown in Figure 7. From Figure 7, we can find that when the COP in heat recovery mode is about two times of the COP in cooling-only mode or heating-only mode. For both the condensing heat and the evaporating heat are made use of, the COP Table 1 Standard condition Condensing Temperature ( o C) 48 Evaporating Temperature ( o C) 1 Q A (W) -3000 Q B (W) 3000 P (W) 1030 Fz (Hz) 51 COP 5.78 of this multiple VRF air conditioning system Figure 7 Performance of the system increases markedly. On the other hand, for the heat transferred from indoor environment to outdoor environment is decreased largely, thus the pollution to the outdoor 928

environment is reduced accordingly. CONCLUSIONS A new multiple VRF air conditioning system with heat recovery has been developed. The basic concept and performance are summarized as follows. The capacity of this system responds to the load of each room by using a variable frequency compressor and electronic expansion valves (EEV) that can control the refrigerant flow for each indoor unit and changing the airflow rate of each heat exchanger. This new VRF system can operate concurrent heating and cooling that can satisfy the heating or cooling of several rooms. Both the condensing heat and evaporating heat are value in use, the coefficient of performance of this system increases markedly, about two times of in the cooling-only mode or heating-only mode. For the heat transferred from indoor environment to outdoor environment is decreased largely, thus the pollution to the outdoor environment is reduced accordingly. REFERENCES [1] M.Masuda, K.Wakahara, K. Marsuki. Development of a Multi-system Air Conditioner for Residential Use. ASHARE Transactions: Research, 1991, Vol.97, Part I: 127~131 [2] Gu Bo, Bao Shixiong, Sun Ningsheng et al. Study on Multi-indoor Unit Inverter Air-Conditioner. Fluid Machinery. 1995, V23(3): 55~57 [3] T.Q. Quieshi, S.A. Tassou. Variable-speed Capacity Controls in Refrigeration System. Applied Thermal Engineering, 1996, 16(2): 103~113 [4] Shi Wenxing, Shi Binhua and Yan Qisen. Three Controlling Methods in Inverter Air Conditioners. HV&AC, 2000, 30(6):16-19 [5] Shi Wenxing. Study on Performance and Control Strategy of Variable Refrigerant Volume Air-Conditioning Systems [Ph.D Themsis]. Tsinghua University, Beijing, China, 2000. [6] Shuangquan Shao, Wenxing Shi, Xianting Li, and Qisen Yan. Study on the Energy Saving of the Variable Refrigerant Volume Air-conditioning System with Heat Recovery. Proceedings of the 4th International Conference on Air Quality, Ventilation and Energy Conservation in Buildings (IAQVEC 2001). Changsha, China, October 2-5, 2001 509-517 929