S A N TA M O N I C C I T Y S E R V I C E S B U I L D I N G E X T E R I O R L I G H T I N G

Similar documents
Lighting Design Criteria: Codes and Standards

HARRY RANSOM HUMANITIES RESEARCH CENTER

Dorrance H. Hamilton Building

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

Lighting Design Thought Process

Lighting Depth Study. Exterior Departure/Canopy Area

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

1.1.0 Exterior Facade

Austin Airport - South Terminal Exterior Lighting 1

HARRY RANSOM HUMANITIES RESEARCH CENTER

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

BUILDING DESIGN STANDARDS FACILITIES MANAGEMENT AND ANCILLARY SERVICES EXTERIOR IMPROVEMENTS DIVISION 32 Exterior Lighting

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

Thesis Proposal Update #2

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

CEILING DESIGN: WHAT is it? and what DOES IT DO?

CENTERS AND CORRIDORS

Café DUSON- Overview

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

CHAPTER 32 EXTERIOR LIGHTING

Lighting Existing Conditions and Design Criteria Report

DOWN BY THE RIVER 090 PROJECT

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

Exterior Façade Lighting Design

LIGHTING NORTH FAÇADE AND PLAZA

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

Lighting Depth Part 1: Exterior Space

Chapter 11. Industrial Design Guidelines 11.1 INTRODUCTION AND PURPOSE 11.3 SITE PLANNING GUIDELINES 11.2 GENERAL DESIGN OBJECTIVES

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

Outdoor Lighting for Julian Dark Sky Network, 2/10/18. Paul Ericson, PE San Diego IDA Board Member / Design Principal, Stantec

3.4 Business & Light Industrial Parks and Buildings

Technical Report 1 Part 2

RESIDENTIAL-USE FIXTURES

Monterey Downtown Lighting Strategy

LINCOLN HIGH SCHOOL MODERNIZATION BEX IV COMMUNITY MEETING JUNE 23, 2016

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Erin McCauley The Gateway Building

No.2 Whitehall Riverside, Leeds July 2013

Shepherd University Wellness Center AE 481 Thesis Lighting Technical Report 1

Landscape and Streetscape Design 2.5

District Design Guidelines - West Village

University of California Santa Barbara. Student Resource Building

COMMUNITY DEVELOPMENT DEPARTMENT

Office of the Chief Medical Examiner Building

FIRE SAFETY INSPECTION REPORT REDPOINT JACKETS LTD, DHAKA, BANGLADESH

STANFORD UNIVERSITY EXTERIOR LIGHTING

Lobby Lighting Design

TECHNICAL ASSIGNMENT #3: SCHEMATIC LIGHTING DESIGN

LED Bollard Collection

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

AVAILABLE THROUGH GRAINGER. LED Fixtures

Eric Anderson. Technical Report 1. Existing Lighting Conditions

LIGHTRECYCLE PRODUCT GUIDE

Overview. The Reading Room

Hospitality. Emergency Lighting

Global Tech LED 8901 Quality Rd Bonita Springs, FL, Fuel Station Lighting Solutions

Belmont Bridge Replacement

ARCHITECTURAL REVIEW BOARD SUPPLEMENTAL PACKAGE 3402 PICO BLVD SANTA MONICA, CA APRIL 10, 2017

BC LIGHTRECYCLE EXPANSION PROGRAM PRODUCT LIST September 7, 2012 Version

District Design Guidelines - Cultural District

AIRPORT BUSINESS PARK

180 ZONING 180. ARTICLE XLII STREETSCAPE ENHANCEMENT OVERLAY ( SEO ) DISTRICT [Added Ord. No. 1086]

Schematic Design Ideas for the Westlake Recreation Center. Presented by: Summer Padgett At Lutron Electronics On December 9, 2003

ARCHWAY TM PASSAGE TM

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

FLORIN ROAD CORRIDOR Site Plan and Design Review Guidelines Checklist

Design Guidelines for Exterior Lighting

D E S I G N G U I D E

Light Fixtures: A Lamp in a Box. Light fixtures are MORE than a decorative object.

BUILDING 751-CEH-OFFICE RENOVATION- OVERALL ROOM DATA SHEET

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

Franklin Square Hospital Center

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

Illumination India.

Architectural Review Board Report

Nagle Place Extension Workshop August 3, 2010

1.0 Introduction to Lighting Depth. 1.1 Hotel Tower Facace and Porte Cochere

Design Guidelines for the Route 30 Corridor Master Plan: Subdivision and Land Development Elements

Lord Stirling Community School

The subject site plan amendment proposes the following revisions to the approved site plan:

Outdoor Emergency Lighting Application Guide

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

5.7 Design Criteria for the Private Realm Organization of Private Realm Design Standards and Guidelines Guidelines vs.

110 lm w STANDARD SERIES

Existing Area Description: The area is an angle around the North point of the building. It is a wide patio wrapping the façade of the building.

FIRE SAFETY INSPECTION REPORT

Office of the Chief Medical Examiner Building. 1 Newhall Street, San Francisco, California

Lindsey Beane. Executive Summary

R E P O R T DEVELOPMENT SERVICES DEPARTMENT Boyd Street: Development Permit application to construct a new building for Westminster Toyota.

Sec Development Standards in the Environmental Overlay (EO) District

Eastern Washington Line Card *Denotes ARRA or Buy American Compliant (Call for exact product verification, not all material qualifies)

Harmony Technology Park Third Filing, Second Replat Custom Blending, Project Development Plan/Final Development Plan - FDP #130021

FREEWAY/TOURIST DISTRICT

PROPOSED DEVELOPMENT CONCEPTS

Lobby Lighting Redesign

Transcription:

S A N TA M O N I C C I T Y S E R V I C E S B U I L D I N G E X T E R I O R L I G H T I N G MAY 8, 2017

SCHEMATIC CALCULATION RENDERING OVERALL VIEW

ENTRY LIGHTING LOW MOUNTING HEIGHT RECESSED WALL MOUNTED BEGA-US, 3000K LED 12.5 W, 2.75 H, 2.5 D 11.2W MAIN ENTRY: PATH OF EGRESS, 1FC MINIMUM FROM EXIT DISCHARGE TO PERMANENTLY DESIGNATED RIGHT OF WAY

ENTRY LIGHTING LOW MOUNTING HEIGHT 39 TALL GROUND MOUNTED BOLLARD BEGA-US, 3000K, LED 39.375 H, 6.5 DIA, 12W MAIN ENTRY AND PLAZA: PATH OF EGRESS, 1FC MINIMUM FROM EXIT DISCHARGE TO PERMANENTLY DESIGNATED RIGHT OF WAY BICYCLE PARKING AND LOCKERS: 0.5FC MINIMUM

ENTRY LIGHTING LOW MOUNTING HEIGHT RECESSED CEILING MOUNTED BEGA-US, 3000K LED 4 DIA, 14W 6 DIA, 26W @ LOADING MAIN ENTRY AND LOADING DOCK STAIR: PATH OF EGRESS, 1FC MINIMUM FROM EXIT DISCHARGE TO PERMANENTLY DESIGNATED RIGHT OF WAY AVENIDA MAZATLÁN WALKWAY: LIGHTING FOR SAFETY AND SECURITY 1FC AVERAGE

ENTRY LIGHTING LOW MOUNTING HEIGHT INTEGRATED MONUMENT SIGN LIGHTING OPTIC ARTS, 3000K, LED 0.82 W, 0.45 T, LENGTH PER SIGN, 2 W/FT.

ENTRY LIGHTING LOW MOUNTING HEIGHT IN GRADE UP LIGHT BEGA-US, 3000K, LED 4.625 DIA, 3.875 DEPTH 4.2W, ASYMMETRICAL WALL-WASH UPLIGHT

COURTYARD GENERAL LIGHTING INDIRECT POLE TOP MOUNTED AREA FIXTURE BEGA-US, 3000K LED 12-0 POLE HEIGHT 14-0 OVERALL HEIGHT 53W UPLIGHT CUT-OFF RATED BUG RATING B1-U2-G1 COURTYARD: PATH OF EGRESS, 1FC MINIMUM ON EGRESS ROUTE

COURTYARD EGRESS SUPPLEMENT 39 TALL GROUND MOUNTED BOLLARD BEGA-US, 3000K, LED 39.375 H, 6.5 DIA, 12W COURTYARD: PATH OF EGRESS, 1FC MINIMUM ON EGRESS ROUTE

FUJINOMIYA DOURI BICYCLE LOCKERS AND PEDESTRIAN PATHWAY 39 TALL GROUND MOUNTED BOLLARD BEGA-US, 3000K, LED 39.375 H, 6.5 DIA, 22W PEDESTRIAN WALKWAY: 0.5FC AVERAGE BICYCLE PARKING AND LOCKERS: 0.5FC MINIMUM

FUJINOMIYA DOURI PHOTOVOLTAIC CANOPIES ASYMMETRICAL FLOOD PROVIDES INDIRECT ILLUMINATION AT PHOTOVOLTAIC CANOPY 15-6 MOUNTING HEIGHT ELLIPTIPAR, 3000K, LED 7.5 H, 17.8 W, 110W AUTOMOBILE PARKING: 0.5FC MINIMUM AUTOMOBILE DRIVE: 0.5FC AVERAGE

FUJINOMIYA DOURI AUTOMOBILE DRIVE AND GENERAL AREA LIGHTING UTILITARIAN AREA LIGHT FOR VEHICLE CIRCULATION 20-0 MOUNTING HEIGHT FULL CUT-OFF RATED B2-U0-G2 LITHONIA, 3000K, LED 7 H, 13 W, 26 L, 35W AUTOMOBILE DRIVE: 0.5FC AVERAGE

FUJINOMIYA DOURI PHOTOVOLTAIC CANOPIES UTILITARIAN WALL MOUNTED LIGHT ON THE INTERIOR OF UTILITY ENCLOSURES NORDEON LIGHTING 50.5 L, 3.33 W, 3.8 H 3000K LED, 37W AUTOMOBILE PARKING: 0.5FC MINIMUM AUTOMOBILE DRIVE: 0.5FC AVERAGE

SCHEMATIC RENDERING, VIEW 1 FROM OLYMPIC

SCHEMATIC RENDERING, VIEW 2 FROM OLYMPIC

SCHEMATIC RENDERING, VIEW 1 FROM MAIN STREET

SCHEMATIC RENDERING, VIEW 2 FROM MAIN STREET

SCHEMATIC RENDERING, VIEW 3 FROM MAIN STREET

OVERALL SITE PLAN POINT-BY-POINT CALCULATION

ENTRY LIGHTING STAIR TO OLYMPIC RECESSED WALL MOUNTED STAIR Illuminance (Fc) Average=8.50 Maximum=14.9 Minimum=2.7 Avg/Min=3.15

ENTRY LIGHTING STAIR TO OLYMPIC RECESSED WALL MOUNTED Ramp to Olympic Illuminance (Fc) Average=4.23 Maximum=9.4 Minimum=1.4 Avg/Min=3.02

ENTRY LIGHTING STAIR TO OLYMPIC 39 TALL GROUND MOUNTED BOLLARD BICYCLE LOCKERS AT OLYMPIC Illuminance (Fc) Average=2.39 Maximum=3.6 Minimum=0.8 Avg/Min=2.99 BICYCLE PARKING AT OLYMPIC Illuminance (Fc) Average=1.51 Maximum=2.7 Minimum=0.5 Avg/Min=3.02

ENTRY LIGHTING STAIR TO OLYMPIC INDIRECT POLE TOP MOUNTED AREA FIXTURE 12-0 POLE HEIGHT 14-0 OVERALL HEIGHT 39 TALL GROUND MOUNTED BOLLARD COURTYARD Illuminance (Fc) Average=1.89 Maximum=3.3 Minimum=0.3 Avg/Min=6.30

FUJINOMIYA DOURI BICYCLE LOCKER UTILITARIAN AREA LIGHT FOR VEHICLE CIRCULATION 20-0 MOUNTING HEIGHT 39 TALL GROUND MOUNTED BOLLARD BICYCLE PARKING AT FUJINOMIYA DO Illuminance (Fc) Average=1.83 Maximum=3.5 Minimum=0.7 Avg/Min=2.61

LOADING DOCK STAIR TO FUJINOMIYA DOURI RECESSED CEILING MOUNTED LOADING DOCK EGRESS PATHWAY, Illuminance (Fc) Average=3.64 Maximum=5.1 Minimum=1.7 Avg/Min=2.14

LOADING DOCK AVENIDA MAZATLÁN, PEDESTRIAN WALKWAY RECESSED CEILING MOUNTED AVENIDA MAZATLÁN COVERED WALKWAY Illuminance (Fc) Average=4.09 Maximum=11.6 Minimum=1.1 Avg/Min=3.72

FUJINOMIYA DOURI - NORTH UTILITARIAN AREA LIGHT FOR VEHICLE CIRCULATION 20-0 MOUNTING HEIGHT UTILITARIAN WALL MOUNTED LIGHT ON THE INTERIOR OF UTILITY ENCLOSURES ASYMMETRICAL FLOOD PROVIDES INDIRECT ILLUMINATION AT PHOTOVOLTAIC CANOPY 19-0 MOUNTING HEIGHT AUTOMOBILE DRIVE Illuminance (Fc) Average=0.68 Maximum=2.1 Minimum=0.2 Avg/Min=3.40

FUJINOMIYA DOURI - SOUTH UTILITARIAN AREA LIGHT FOR VEHICLE CIRCULATION 20-0 MOUNTING HEIGHT ASYMMETRICAL FLOOD PROVIDES INDIRECT ILLUMINATION AT PHOTOVOLTAIC CANOPY 19-0 MOUNTING HEIGHT AUTOMOBILE DRIVE Illuminance (Fc) Average=0.68 Maximum=2.1 Minimum=0.2 Avg/Min=3.40

www.burohappold.com