Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions

Similar documents
INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE. Model 807. Electric Heater. Fitted with one of the following fascia

INSTALLER AND OWNER GUIDE

Model 804. Chic, Envy, Mirage, Serenity or Twilight fascia.

Model 809 Electric Heater

INSTALLER AND OWNER GUIDE

Model 850 ELECTRIC HEATER

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLATION AND USER INSTRUCTION GUIDE. Model (s) Electric Heater Model No s FRER**ME2 / FSER**ME2 / FMER**ME2. ** Denotes case colour / finish

INSTALLER AND OWNER GUIDE

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION & USER INSTRUCTIONS

Use & Care Manual Inset Electric Fires

(SP4) SP420 (SP5) SP520 (SP9) SP920 AUS/NZ. 08/50019/5 Issue 5

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

Contact Details. Please note that some of the contact details on this PDF document may not be current.

SP16. 08/50740/1 (UK) - Issue 1

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

USE & CARE MANUAL COMPACT ELECTRIC FIREPLACE SUITE. CO9158 V1_301012

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

INSTALLATION & USER INSTRUCTIONS

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

INSTALLATION & USER INSTRUCTIONS

INSTALLATION & USER INSTRUCTIONS

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

INSET LIVE FUEL EFFECT GAS FIRE

INSTALLATION & USER INSTRUCTIONS

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

SP1 Wallfire. SP2 Wallfire. SP3 Wallfire. SP8 Wallfire AUS/NZ. 08/19282/2 (AUS & NZ) Issue 2

Contact Details. Please note that some of the contact details on this PDF document may not be current.

INSTALLATION & USER INSTRUCTIONS

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

Installation & Operating Instructions. Models: York Midi & Serrano Electric Stoves

USE & CARE MANUAL CONTEMPORARY ELECTRIC FIREPLACE SUITE. CO9144 V3_080714

INSTALLATION & USER INSTRUCTIONS

Model 347 BLACK BEAUTY

Installation and Maintenance Instructions XPG170 Electric Fires

Installation and Maintenance Instructions XPG144/145/146 Electric Fires

Model BR660VA Heat Engine

Installation & User Instructions:

INSTALLATION & USER INSTRUCTIONS

USE & CARE MANUAL. ELECTRIC FIREPLACE SUITE (remote control operated) ADI0010 V

Riva2 670 Electric. Instructions for Use, Installation & Servicing. For use in AU & NZ (Australia & New Zealand). IMPORTANT

Model 341 Black Beauty Slimline

ECOLEC PANEL HEATERS GENERAL NOTES.

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

INSTALLER GUIDE COALFLAME & LIMOUSIN. MODEL BR627 (GC No ) INSET LIVE FUEL EFFECT GAS FIRE

Use & Care Manual Contemporary Electric Fires

Dovre 280 or 425 Electric

Sonnet Plus Anthem Genesis Soraya

16 Ultiflame Inset Electric Fire

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Sonnet Plus Anthem Genesis Soraya

OWNER S GUIDE MODEL BR417 VA

Electric Riva Flame-Effect Cassette Fire

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

INSTALLATION & USER INSTRUCTIONS

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Radiance Electric Range

MODEL 466 Radiant / Convector Gas Fire Black Beauty

INSTALLATION & USER INSTRUCTIONS

INSTRUCTION MANUAL. This product is only suitable for well insulated spaces or occasional use.

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL

Electric Fireplace. Electric Fireplace

Adorn, Dream, Masquerade, Excelsior, Classica, Icon or Visage

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

HARTFORD SLIM ASSEMBLY INSTRUCTIONS. IMPORTANT - RETAIN FOR FUTURE REFERENCE - READ CAREFULLY.

16 XD Mk2 Inset Electric Fire

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

Imperial Electric Fires

INSTALLATION & USER INSTRUCTIONS

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

INSTALLER S GUIDE. Model BG C-2. (GC No ) INSET LIVE FUEL EFFECT GAS FIRE. (Manufacturer ref. BR658VA)

OWNERS INSTRUCTION MANUAL

BSF60WH / BSF60SS BUILT IN ELECTRIC FAN OVEN. Instruction Manual. Please read these instructions carefully before use and retain for future reference

INSTALLATION & USER INSTRUCTIONS

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Legend VENTED GAS FIREPLACE HEATERS

Wall Mount Electric Fire Place with Remote Control

Owner s Guide and Installation Manual

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

Installation Instructions & Operating Manual IMPORTANT

EH kW Panel Heater

ELECTRIC FIREPLACE with Remote Control

WALL HUNG FIRE Model: LDBL2000A-DD4BR Ref:22217

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Radiance Electric Range

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

SP420 & SP14 SP520 & SP15 SP920 & SP19. 08/19222/9 (UK) - Issue 9

Transcription:

INSTALLATION AND OPERATING GUIDE For Electric Heaters Model 801 With Adorn, Icon, Visage, Elegant or Ultimate Fireslide fronts & Model 802 Ultimate, Cosyflame, Fyrside, Nebula & Pizzazz versions This guide is intended to help you install and care for your Valor electric heater. Please read carefully before installing and using your heater. Important Please keep your Guide in a safe place for future reference 600B599/06

CUSTOMER CARE Thank you for choosing Valor All Valor heaters are designed to meet the most stringent quality, performance and safety requirements to provide our customers with many years of trouble free service. This guide aims to improve your understanding and appreciation of your new Valor heater, by providing simple and informative instructions to enable you to install it and to ensure that you benefit from the excellent performance and features it has to offer. If you require further assistance, the Valor AdviceLine will be pleased to help. Please telephone 08457 626 341 (local rates apply in the United Kingdom) FOR OTHER USEFUL TELEPHONE NUMBERS SEE THE BACK COVER IMPORTANT SAFETY INSTRUCTIONS It is important that the following safety instructions are followed Always Always install the heater in accordance with the instructions. If in doubt obtain expert advice. Always make sure the electrical socket is accessible and located adjacent to, but not above the heater. Always disconnect the heater from the electrical supply before carrying out cleaning, maintenance or replacing lamps. Always make sure the heater is firmly secured to the fireplace opening to prevent the fire from being tipped over. Always use a fireguard when young children and infirm persons can come into contact with the heater. Always use genuine Valor spares. Never Never leave children unsupervised in a room where the heater in ON and unguarded. Never obstruct or cover the fan outlet or force items into heater openings. Never install or use the heater anywhere where water is in use, i.e. Bathrooms, Shower Rooms etc. Never use aerosols on or around the heater. Never route the mains supply cable under carpet etc. Never install the heater close to curtains or combustible materials. Never use the heater to dry clothes etc. 2

General Appliance dimensions Model Projection into Projection into Overall depth Width (mm) Height (mm) cavity (mm) room (mm) (mm) 801 Adorn 68 153 221 545 768 801 Icon 68 59 127 631 622 801 Visage 68 89 157 529 611 801 Elegant 68 89 157 529 611 801 Ultimate 68 89 157 475 600 Fireslide 802 Ultimate 68 89 157 475 600 802 Cosyflame 68 89 157 475 600 802 Fyreside 68 79 147 475 600 802 Pizzazz 68 79 147 475 600 802 Nebula 68 89 157 475 600 Fireplace opening This heater is intended for use in a fireplace opening generally conforming to British Standard 1251 for a nominal 400mm (16 inch) or 450mm (18 inch) Fireplace. It may also be located in other fireplace openings or in a wooden surround, where the following dimensions are available. Width 390 450mm Height 555 590mm Depth At least 75mm Clearance for servicing There should be a clearance of at least 30mm between the top of the appliance and any mantle or shelf so that the outer surround can be lifted off for servicing access. Spacers and Wall Kits: The heater is of a slim design and should suit most fireplace openings and fire surrounds, however there may be some applications that require the need for either a spacer or flat wall kit. The following table identifies which spacer or wall kit is available for each heater. The Model 802 Fyreside version is supplied with a 75mm wall kit. For all other appliances the kits are optional extras obtainable either from the your heater supplier or direct from Valor Sales. Model 60mm (2.1/2 ) Surround Rebate Flat Wall (no recess) 20mm Spacer Kit No. 75mm Wall Kit No. Model 801 Ultimate Fireslide 05801R1 05801T1 Model 801 Visage 05801S1 05801U1 Model 801 Elegant 05801S1 05801U1 Model 801 Adorn Not Available Not Available Model 801 Icon Not Available Not Available Model 802 Ultimate, Nebula, Cosyflame, Fyrside & Pizzazz 05801R1 05801T1 Unpacking Model 801 with Visage, Elegant or Ultimate Fireslide front & Model 802 These are packed in a single carton. This contains the main appliance. In a separate box is the cast fascia complete with coal pack. Model 802 Fyrside also includes a 75mm wall spacer kit. Model 801 with Adorn front Twin Pack Pack 1 - Main Fire Pack Pack 2 Contains cast iron face, the fuel effect and coal pack. Model 801 with Icon front Twin Pack Pack 1 - Main Fire Pack Pack 2 Contains the face complete with log effect 3

Installation The heater must be fixed into position to prevent it from being tipped over. The following fixing options are available. The parts required for both fixing options are included with all appliances. Screw fixing Wire fixing The heater must not be located under a fixed electrical socket, the socket must always be accessible in order to disconnect the heater from the electrical supply for maintenance or when replacing a lamp. Important! This heater must be earthed. The heater is supplied with a 3 pin 13A fused re-wireable plug with 1mm². 3 core mains cable, L = Brown N = Blue E= Green/Yellow The mains supply cable must be safely routed from the heater to an electrical socket. Provision is made for left/right or rear cable entry. Using one of the three cable guides at the base of the heater. To relocate, open the appropriate latch on the cable guide and refit the mains cable into the required position. If the mains cable is damaged, to avoid a hazard it must be replaced by a Valor authorised service agent, or a similarly qualified person. All external wiring between the appliance and the electrical supply, including the earthing, shall comply with current IEE regulations. The heater body should be fixed in position before the front surround is finally fitted. N.B: Please study the illustrations carefully to avoid damage to the heater. Front Removal All Models except those with Adorn or Icon front Model 801 Detach the control linkage See figure 1 Models 801 & 802 Carefully remove the front surround by removing the two trim fixing screws and lifting upwards and forward See figure 2 Do Not Lift The Front Surround By The Control Knob Keep the front surround and screws in a safe place when installing the fire. Offer the heater body to the fireplace opening to ensure that it will fit before continuing with the installation. Appliance Fixing Figure 1 Method A Screw Fix There are two slots in the top flange See figure 3. Mark the fixing position through the slots. Remove the heater. Drill a hole with a No.12 drill bit at each marked position. Insert the wall plugs provided. Reposition the heater body and screw through the slots to provide a secure fixing. Figure 2 Method B Wire Fix The fixing kit includes a steel wire and eyebolt to attach the heater to the back of the fireplace opening. Mark the position for the eyebolt at the back of the fireplace opening equal to the centre line of the heater and at a height of 533 560mm. Drill, plug and screw in the eyebolt See figure 4. Thread one end of the steel wire through the two holes in the top flange, passing the wire through the eyebolt and out through one of the opposite holes on the top flange See figure 4. Locate the heater into the fireplace opening, then by gently pulling the steel wire, gather up the excess until the heater is firm. Thread the wire back through the remaining hole to lock the wire and heater in place See figure 4. Figure 3 Method C With 20mm Wall Spacer (Optional extra) The spacer should be fixed to the fireplace opening or surround using the screws provided. The heater must then be fixed to the spacer using the screws provided. (See following section Wall spacer kit installation) Figure 4 4

Method D With 75mm Wall Spacer Kit (Supplied with Model 802 Fyrside, optional extra with other appliances) The wall kit should be securely fixed to the wall using the screws provided. The heater must then be fixed to the wall kit. (See following section Wall spacer kit installation) If fixing through marble, ensure that both rawlplug and screw pass freely through the marble. Secondary Screw fixing If felt beneficial, the appliance can be additionally secured by screws through the side flanges see figure 5. Wall Spacer kit installation Figure 5 5

Assembly of Fronts Icon & Adorn Fronts Remove the tape securing the control linkage to the front. Do Not Lift The Front Surround By The Control Knob All Models Carefully lift the front surround. Hook the front surround onto the retaining plates on the heater body and lower the front surround down See figure 6. All Model 801 Versions Check that the switch control spindle is in the OFF position and the slider is in the OFF position. Swing the control linkage/boss towards the control spindle on the heater and push the boss onto the spindle, ensuring the D flats are in alignment See figure 7 Final Assembly All Models With the two screws provided, fix the front surround to the heater body See figure 8 Check the controls to make sure they operate smoothly. Figure 6 Icon Model Fix the lower cover to the front surround corner brackets using the two knurled screws provided See figure 9. Model 801 Visage, Elegant and Ultimate Fireside and all Model 802 versions Place the front casting/fuel support in position by passing the screw heads/hooks through the keyhole slots in the surround and lowering down See figure 10. Figure 7 Figure 8 Figure 9 Figure 10 (Shown with Elegant Front) 6

Important Before continuing any further with the installation or using the fire for the first time, please check that the flame effect drum is correctly positioned, as this can sometimes become dislodged during transit. To do this: Lift out the fuel bed. You will then see the two light bulbs with the drum above them. The drum has a spring-loaded plunger at its right hand side. This should fit into the indent in the black plastic bracket. If it is out of position simply push it back into the indent. Fuel Effects Icon Place the log fuel effect in position in front of the glass screen See figure 11. Adorn Fit the coal support See figure 12. Figure 11 Figure 12 All Models except Icon Front Open the polythene bag containing the loose coals and place them on and in front of the coal support to give the most pleasing effect. It is not necessary to use all the coals supplied. All Models Place the ash except Icon, Fyrside & Pizzazz pan into position below the casting. Operating the Heater Never cover the heater, there is a risk of fire if covered. Model 802 The heater is operated by three switches, located below the canopy. Switch 1 = O Switch 2 = Switch 3 = Main On Off In the On position only the fuel effect light operates 1 kw fan heat setting and fuel effect 2 kw fan heat setting and fuel effect The switches are mechanically interlocked, so when switch 1 is turned off, all switches turn off. Model 801 These models have a slider control located on the right side of the surround for operating the main functions of the heater. Located to the left of the fan outlet grille are a lamp dimmer control and a room thermostat control. The Lamp Dimmer is used to set the light output of the fuel effect between off and high as required. The Room Thermostat is used to maintain room temperature, the higher the setting, the higher the room temperature will be before the heater turns off. When using the fan Coolblow setting, the thermostat should be turned to a high position. 7

The Slider Control There are four slider positions Off Fuel effect lighting on Fan Coolblow on. Fuel effect lighting on (Set thermostat at High). Fan heater on (2kw). Fuel effect lighting on (Set thermostat to a high setting and allow the room temperature to settle before re-adjusting). 8

Maintaining Your Fire Always disconnect the heater from the electricity supply by removing the 3 pin plug and allowing the heater to cool before undertaking maintenance or replacing lamps. Lamp Replacement The lamps fitted to this heater are long life types, but due to the indeterminate life span and ease of replacement are specifically excluded from the guarantee. To replace a lamp. All Models except Adorn and Icon Remove the accessible loose coals. Unhook the front casting by lifting slightly to disengage the unit from the keyhole slots in the trim and gently pull forward. Replace with a 60W (maximum) clear Edison screw lamp. Do not use opaque or coloured lamp bulbs. Refit the front castings and relocate the coals. Adorn and Icon Models Remove the coals (Adorn). Lift out the coal support/fuel effect. It will also be necessary to remove the effects drum to access the lamps. To remove, hold the drum and firmly slide it to the right to disengage it from the motor spindle, withdraw it from the heater See figure 13. Replace with a 60W (maximum) clear B22 Edison screw lamp. Do not use opaque or coloured lamp bulbs. Refit the drum by sliding onto the motor spindle and pushing the other end into its location socket See figure 13. Check that the drum rotates correctly. Refit the coal support/fuel effect and coals (Adorn). Automatic Cut Out Figure 13 A cut out is fitted to the heating element to prevent damage due to over heating. If it operates due to an obstruction in the airflow, the heater must be turned off and allowed to cool for 15 minutes, obstruction removed before restarting. Care and Cleaning The canopy trims and glass parts need only to be wiped clean with a dry soft cloth, do not use polishes or abrasive materials. Fault Finding No or low light from the fuel effect: Check the lamp dimmer is turned to high, if it is, then it is possibly a lamp failure. Remove the lamp as detailed above and check it in a table lamp, that is known to work. No heat or light: Check the wall socket by plugging in a known working appliance. If functional check the 13A fuse in the heater plug. If either fuse or socket is suspected, have them checked by an electrician. Light but no heat: The automatic cut out, may have operated, see above. Disposal At the end of the products serviceable life it should be disposed of thoughtfully and safely in accordance with local authority regulations. The plug should be removed from the mains cable and the mains cable cut from the heater. 9

USEFUL TELEPHONE NUMBERS To help us quickly help you, please try to have the following information available before you contact us. Your Post Code Type of Fire Model / Name Serial Number The fault, problem or request General advice about your heater VALOR ADVICE LINE 08457 626 341 To report faults or arrange for your heater to be serviced VALOR SERVICE 0121 386 6203 To order spares or for sales information VALOR SALES 0121 386 6260 Callers in the Republic of Ireland Call 00 44 121 373 8111 10