Susan Wakil Health Building. Noise and Vibration Monitoring Report 26 September 24 November S180787RP1 Revision 0 Monday, 17 December 2018

Similar documents
NOISE AND VIBRATION STANDARD

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

D AVID L ORD, P H.D. Principal Consultant. February 17, 2014 Cate School Sound Level Assessment Project 1436

505 Petaluma Boulevard South Petaluma, California Tel: Fax:

Queen St E & Leslie St Noise Analysis Toronto, Ontario. Toronto Transit Commission Streetcar Department 1900 Yonge Street Toronto, ON M4S 1Z2

draft dated 9/17/2015 page 1

The Urban Park Soundscape in Mountainous Cities:A case study in Chongqing

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring June 2015

A Guide to Occupational Noise Measurement Terminology

Patrick Port Botany Terminal Biannual Environmental Noise Compliance Monitoring May 2018

Patrick Port Botany Container Terminal Biannual Environmental Noise Compliance Monitoring May 2017

This document is a preview generated by EVS

In order to ensure that there is a clear interpretation of this report the following meanings should be applied to the acoustic terminology:

Vibration tests on a TNAML Luminaire

ROCKEFELLER UNIVERSITY

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

BRIDGECLIMB SYDNEY REDUCING TONAL NOISE FROM SAFETY LATCHES

Wayside horn noise investigation

Listen Out 2016 Centennial Parklands, Sydney 1 st October 2016

Staff Report. Conditional Use PLANNING DIVISION COMMUNITY & ECONOMIC DEVELOPMENT. Salt Lake City Planning Commission

Stage 2: WestConnex M5 King Georges Road Interchange Upgrade. Appendix B5 Construction Heritage Management Plan


Avicii 2014 Centennial Parklands, Sydney 25 th January 2014

SAN FRANCISCO MUNICIPAL TRANSPORTATION AGENCY

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

BY-LAW AMENDING THE BY-LAW CONCERNING THE SERVICE DE SÉCURITÉ INCENDIE DE MONTRÉAL (RCG )

Adopted February 1977 Recoded May 1998 Revised September 2007 Reviewed July 2014 Revised July 2017 EMERGENCY DRILLS

The attached report presents the results of the observations and monitoring performed on April 10, 11, and 19, 2018 by Devin Porter of ATC.

Analysis of Potential Community Noise Impacts

Carleton University. Nicol Building New Sprott School of Business. Design Brief and Planning Rationale. Carleton University

Fire Risk Assessment Borough High Street

Review of Environmental Factors Addendum. Green Square Stormwater Drain Shea s Creek Channel Corridor Restoration

Planned Development Review Revisions (Project No. PLNPCM )

D3 January 14, 2015 Public Hearing

CITY OF MEDINA OFFICE OF THE HEARING EXAMINER

POLICY. Code Announcement means an announcement (e.g. page or strobe light, verbal notification) to commence a Fire Drill without an audible alarm.

CITY CLERK. Consolidated Clause in North York Community Council Report 8, which was considered by City Council on October 26, 27 and 28, 2004.

ASD Installation On A P&H 4100 Electric Rope Shovel

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

Topham Mall, Bentham, Pitt and Waymouth Street Place Plan

Prince William County Rural Preservation Study

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

NOISE STUDY CALEDON EQUESTRIAN PARK TOWN OF CALEDON

Pyroelectric Infrared Sensor PIR

Battery Performance Alert

LAND USE ASSESSMENT REPORT (LUAR) PROPOSED AFFORDABLE HOUSING COMPLEX MAIN ROAD PDE FILE NUMBER: REZ

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

If the address on this form is different than the address of the building, submit a written explanation.

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Electric radiator test

CMCS Ltd. Precision monitoring for the construction industry to help manage risk

City of Surrey PLANNING & DEVELOPMENT REPORT File:

Policy for safe working on Fire Alarm Systems at Loughborough University and Loughborough University in London

STATION RISK PROFILE 2018 MALVERN

The Emergence of Triboelectric Technology

DESIGN OF AIR-CONDITIONING SYSTEM FOR SARS WARDS. By Yuguo Li and SARS Busters * Background

Community Development and Recreation Committee

HEALTH SCIENCES BUILDING

Planning Proposal under section 55 of the EP&A Act

Fire Enforcement Report

BOARD OF SUPERVISORS BUSINESS MEETING ACTION ITEM. Endorsement of Design for Route 7/George Washington Boulevard Overpass. Algonkian and Broad Run

ARLINGTON COUNTY, VIRGINIA

DIGITAL CENTRALIZED Section NANOMASKIT

1 The development hereby permitted shall be carried out in accordance with the following approved plans:

CHAPTER 96: NOISE. Section

Sound Performance Rating of Outdoor Unitary Equipment

City Council Special Meeting AGENDA ITEM NO. C.

Statement of Community Involvement LAND OFF SOUTHDOWN ROAD HORNDEAN, HAMPSHIRE

Abstract. Introduction

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

WEST AREA PLANNING SUB-COMMITTEE. Elm Park, Elm Terrace, Cricklewood Tree Preservation Order TPO/CA/419

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

Local Ordinance Targeted to Low-Frequency Noise

INTRUDER ALARM FOR BUSINESS SECURITY

Master Planning: Cuba, New York Phase II. Dr. John Anderson President Alfred State College. Alfred New York

Part Number Structure ZT 028 L D CT R 15

REFERENCE: B/03745/12 Received: 02 October 2012 Accepted: 05 October 2012 WARD(S): Totteridge Expiry: 30 November 2012.

PQS Independent type-testing protocol

6 th Pipeline Technology Conference 2011

Draft FPA Australia Technical Specification for Public Comment FPAA101H DRAFT

Gadsden County Planning Commission Agenda Request

EAST VILLAGE STRATEGIC SITE NOVEMBER 2017

Oxnard, California Code of Ordinances

CHAPTER 20: INSTITUTIONAL USE DEVELOPMENT STANDARDS

Product Application Guide- Industrial Alarms

that the Town Board of the Town of East Greenbush will hold a public hearing on April 11,

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

GLOSSARY OF ACOUSTICAL TERMS

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

THE GEORGE WASHINGTON UNIVERSITY MOUNT VERNON CAMPUS

TENTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION, ICSV10 REAL TIME CONTROL OF SOUND PRESSURE AND ENERGY DENSITY IN A MINING VEHICLE CABIN

SUBJECT: Proposed Downtown Mobility Hub Precinct Plan and Proposed Official Plan Policies

White Paper: Video/Audio Analysis Technology. hanwhasecurity.com

AS/NZS 4745:2012. Code of practice for handling combustible dusts AS/NZS 4745:2012. Australian/New Zealand Standard. Superseding AS/NZS 4745:2004

Product Application Guide- IEC Medical Alarms. cul On-line Listing of Models Approved to IEC :

CITY OF SURREY BY-LAW NO SURREY SECURITY AND FIRE ALARM BY-LAW,

Fire Risk Assessment 2017

ARLINGTON COUNTY, VIRGINIA

ARLINGTON COUNTY, VIRGINIA

Fire safety procedure

Transcription:

Susan Wakil Health Building Noise and Vibration Monitoring Report 26 September 24 November 2018 Monday, 17 December 2018

Document Information Project Client Susan Wakil Health Building Construction Monitoring Laing O'Rourke Sydney Report title Noise and Vibration Monitoring Report 26 September 24 November 2018 Project Number Author Reviewed by S180787 Tom Evans Managing Director p+61 3 9020 3888 m+61 421 279 929 tom.evans@resonate-consultants.com Damien van Raaphorst Revision Table Report revision Date Comments 0 17 December 2018 For Issue

Glossary A-weighting Daytime db db(a) Evening Frequency (Hz) ICNG A spectrum adaption that is applied to measured noise levels to represent human hearing. A-weighted levels are used as human hearing does not respond equally at all frequencies. Between 7 am and 6 pm as defined in the INP. Decibel a unit of measurement used to express sound level. It is based on a logarithmic scale which means a sound that is 3 db higher has twice as much energy. We typically perceive a 10 db increase in sound as a doubling of that sound level. A Weighted sound level in db. Between 6 pm and 10 pm as defined in the INP. The number of times a vibrating object oscillates (moves back and forth) in one second. Fast movements produce high frequency sound (high pitch/tone), but slow movements mean the frequency (pitch/tone) is low. 1 Hz is equal to 1 cycle per second. The human ear responds to sound in the frequency range of 20 to 20,000 Hz. New South Wales Interim Construction Noise Guideline INP New South Wales Industrial Noise Policy, 2000. Intrusive Noise L10 L90 Leq Lmax mm/s μm/s Night-time Rating Background Level (RBL) Noise emission that when assessed at a noise-sensitive receiver (principally a residential premises boundary) is greater than 5 db(a) above the background noise level. Noise level exceeded for 10% of the measurement time. The L10 level is commonly referred to as the average maximum noise level. Noise level exceeded for 90% of the measurement time. The L90 level is commonly referred to as the background noise level. Equivalent Noise Level Energy averaged noise level over the measurement time. Maximum measured sound pressure level in the time period. Millimetres per second units of vibration velocity. Micrometres per second units of vibration velocity. Between 10 pm on one day and 7 am on the following day as defined in the INP. Overall single-figure A-weighted background level representing an assessment period (Day/Evening/Night). For the short-term method, the RBL is simply the measured L90,15min noise level. For the long-term method, it is the median value of all measured background levels during the relevant assessment period.

Table of Contents 1 Introduction... 1 2 Monitoring details... 2 2.1 CNVMP monitoring requirements... 2 2.2 Locations... 2 2.3 Monitoring dates... 2 2.4 Equipment... 3 2.5 Limitations and non-conformances... 3 3 Noise and vibration management levels... 5 3.1 Noise Management Levels... 5 3.2 Vibration Management Levels... 5 3.2.1 RPAH and Wesley College... 5 3.2.2 Bosch 1B Laboratory Animal Services... 5 4 Monitoring results... 6 4.1 RPAH... 6 4.1.1 Noise... 6 4.1.2 Vibration... 6 4.2 Bosch 1B Laboratory Animal Services... 6 4.2.1 Vibration... 6 4.3 Wesley College... 7 4.3.1 Noise... 7 4.3.2 Vibration... 7 5 Conclusion... 8

1 Introduction Laing O Rourke is constructing the Susan Wakil Health Building (the Project) at the University of Sydney. The Project, which is Stage 1 of a Health Precinct, involves the construction of an eight-level building that will provide a range of teaching and support spaces for the co-location of the Faculty of Nursing and Midwifery, the Faculty of Health Sciences and the Central Clinical School. The Stage 1 building will be constructed adjacent to the Royal Prince Alfred Hospital (RPAH). As part of the Project Approval issued by the Department of Planning & Environment (DPE) for the Project, Laing O Rourke engaged Resonate to prepare a Construction Noise and Vibration Management Plan (CNVMP). 1 One of the requirements of the CNVMP was for noise and vibration monitoring to be conducted at various locations around the site. The CNVMP came into effect on 26 September 2018 when the site establishment works commenced. EHO Consulting was engaged to conduct noise and vibration monitoring from the period from 26 September to 24 November 2018. This report summarises the results of the noise and vibration monitoring conducted by EHO Consulting and considers the results against the requirements of the CNVMP. 1 Resonate, 1 of 9

2 Monitoring details 2.1 CNVMP monitoring requirements The CNVMP requires the following monitoring to occur at sensitive locations around the construction site: Table 1 CNVMP monitoring requirements Monitoring requirements at receptors Attended monitoring to assess typical construction noise levels at RPAH and Wesley College Attended noise monitoring in response to a complaint if an appropriate response Continuous vibration monitoring at RPAH Continuous vibration monitoring at Bosch 1B Laboratory Animal Services Continuous vibration monitoring if works occur within safe working distance for building damage Attended vibration monitoring in response to a complaint if an appropriate response How addressed by EHO monitoring Continuous noise monitoring data available at RPAH and Wesley College for extended periods. Not applicable as continuous noise monitoring occurring during period to respond to any complaints. Continuous vibration monitoring data available at RPAH for majority of period from 26 September 24 November. Continuous vibration monitoring data available at Bosch 1B for majority of period from 26 September 24 November. Not applicable as works did not occur within safe working distances. Not applicable as continuous vibration monitoring occurring during period to respond to any complaints. 2.2 Locations Noise and vibration monitoring was conducted by EHO Consulting at the following locations across the period considered within this report: RPAH Bosch 1B Laboratory Animal Services Wesley College. Figure 1, extracted from the EHO Consulting report, shows the location of the monitors in relation to the construction site (Blackburn Building). 2.3 Monitoring dates Noise and vibration monitoring data has been provided by EHO Consulting for the following time periods at each location: RPAH: continuously from 23 September to 24 November 2018, except for the period from 14 October to 20 October inclusive. Bosch 1B Laboratory Animal Services: continuously from 23 September to 24 November 2018, except for the period from 7 October to 20 October inclusive. Wesley College: continuously from 28 October to 24 November 2018. 2 of 9

Figure 1 Monitoring locations from EHO Consulting Report 2.4 Equipment Monitoring was conducted using Svan-958A analysers, which are suitable for conducting noise and vibration monitoring. The monitors were configured to record: A-weighted Leq,15min noise levels Peak Particle Velocity (PPV) vibration levels in mm/s. The monitors were connected to SvanNet, and configured to send alerts to nominated site representatives when preset noise and vibration trigger levels were exceeded. The EHO Consulting reports provide copies of calibration certificates for the units from a NATA-accredited laboratory that demonstrate the units were in current calibration. 2.5 Limitations and non-conformances The noise and vibration monitoring conducted by EHO Consulting did not fully conform to the CNVMP under the Project Approval and some limitations apply to this analysis. These are summarised and discussed in Table 2. Table 2 Limitations or non-conformances Limitation or non-conformance Noise monitoring at Bosch 1B Laboratory Animal Services was based on A-weighted noise levels, which is not suitable for the assessment of noise at that location as the A- weighting is designed for humans and not relevant to laboratory animals. Comment The noise monitoring data at Bosch 1B is not presented in this report as it is not relevant to the assessment of noise at that location. Continuous noise monitoring was not a requirement of the CNVMP at Bosch 1B and therefore this limitation is not considered a nonconformance against the CNVMP. 3 of 9

Limitation or non-conformance No data was provided for some periods. Vibration alert trigger levels for RPAH and Bosch 1B were set at 4 mm/s PPV and 2 mm/s PPV respectively, whereas more stringent trigger levels were required in the CNVMP. Comment While significant data was available at both RPAH and Bosch 1B across the monitoring period, 1-2 weeks of data was not available at each location. Data was also unavailable for extended periods at Wesley College but it is noted that continuous monitoring was not required at this location under the CNVMP. This is a non-conformance and would mean that some vibration alerts would have been missed. However, it is noted that the works generally complied with the vibration management levels specified in the CNVMP. 4 of 9

3 Noise and vibration management levels Noise and vibration management levels for the Project construction phase are documented in the CNVMP. This section presents noise and vibration management levels relevant to the monitoring locations considered in this report. 3.1 Noise Management Levels Table 3 presents the Noise Management Levels (NMLs) for both Wesley College and RPAH. Table 3 Noise Management Levels applicable to Project Land use External NML for time period in db(a) unless otherwise indicated Standard Working Hours Extended periods on Saturdays 7:30 8 am, 1 3:30 pm Other times (if required) Wesley College 56 (NML) 75 (Highly noise affected) 51 51 Royal Prince Alfred Hospital and associated buildings including Chapel 70 70 70 The NML reflects the level above which there may be some community reaction to noise and for which all reasonable and feasible work practices should be implemented. For Wesley College, a highly noise affected level of 75 db(a) also applies. This reflects a level above which respite periods may require consideration. 3.2 Vibration Management Levels 3.2.1 RPAH and Wesley College The CNVMP recommends an alert level of 0.6 mm/s PPV for RPAH as the basis for the continuous vibration monitoring at RPAH and this has been adopted as the Vibration Management Level (VML) for both RPAH and Wesley College. Vibration levels above 0.6 mm/s may indicate the potential for disturbance to building occupants in hospital wards and residential areas of Wesley College. The VML reflects the level above which there may be some community reaction to noise and for which all reasonable and feasible work practices should be implemented. Note that much higher levels of vibration are required in order to pose a risk of building damage. 3.2.2 Bosch 1B Laboratory Animal Services The CNVMP recommends an alert level of 0.1 mm/s RMS for the Bosch 1B Laboratory Animal Services. However, the monitor installed at this location was only capable of measuring PPV vibration levels and does not report RMS levels. PPV levels will always be higher than RMS levels for a particular vibration event. In our experience it is common for PPV levels to be at least four times higher than RMS vibration levels, and therefore a VML of 0.4 mm/s PPV has been adopted for Bosch 1B Laboratory Animal Services. 5 of 9

4 Monitoring results The noise and vibration monitoring results collected by EHO Consulting are presented graphically on the weekly graphs in Appendix A, compared against the relevant NMLs and VMLs. The Standard Working Hours are shaded on each graph to indicate the periods within which noise and vibration may be the result of construction activities. Note that events that were obviously caused by extraneous sources, such as an individual coming into contact with the vibration sensor, have been removed from the graphs. 4.1 RPAH 4.1.1 Noise Throughout the monitoring period at RPAH, measured noise levels exceeded the NML of 70 db(a) Leq,15min for a total of 11 occasions during working hours throughout the entire monitoring period. It is noted that some of these occurrences may be the result of extraneous events as a number of exceedances of the NML occurred outside of working hours. Given the relatively small number of isolated exceedances that occurred throughout the entire monitoring period, it is not considered that noise levels from the construction works are significantly impacting on RPAH. However, reasonable and feasible noise mitigation measures should be implemented on site as per the approved CNVMP. 4.1.2 Vibration The VML of 0.6 mm/s PPV was also exceeded a total of 11 times during working hours across the entire monitoring period at RPAH. As for the noise monitoring results, some of these occurrences are likely to be the result of extraneous events as a number of additional exceedances occurred outside of working hours. Given the small number of isolated exceedances, indicating that extended periods of perceptible vibration did not occur at RPAH, it is considered that vibration impacts from the construction works at RPAH were managed appropriately during the monitoring period. 4.2 Bosch 1B Laboratory Animal Services 4.2.1 Vibration The VML of 0.4 mm/s PPV was exceeded a total of 13 times during working hours at Bosch 1B Laboratory Animal Services. The majority of these events were short-term in nature, with no associated build-up of vibration levels around the event, indicating that they may have been the result of activities within the space rather than a result of construction activities. For example, staff entering a room for feeding or cleaning activities may have been the cause of a number of these events. Regardless, only a small number of vibration exceedances occurred during the monitoring period at Bosch 1B and, on each occasion, the results were generally followed by periods of low vibration levels. This indicates that there were no extended periods of vibration above the VML at Bosch 1B and that vibration from the site was being managed appropriately. 6 of 9

4.3 Wesley College 4.3.1 Noise Measured noise levels at Wesley College often exceeded the relevant NML of 56 db(a) during Standard Working Hours but were generally below 65 db(a). Exceedances of the NML at this level were envisaged by the CNVMP and are acceptable with the implementation of reasonable and feasible noise mitigation measures as per the CNVMP. There was one 15-minute period on 29 October where the measured noise levels at Wesley College exceeded the 75 db(a) level for highly noise affected. However, given it was a single occurrence and noise levels for the 15-minute periods either side were markedly lower, it may have been the result of extraneous noise rather than construction noise. Regardless, any exceedance of the highly noise-affected level was a one-off event and was not repeated throughout the remainder of the monitoring period. 4.3.2 Vibration No vibration events occurred at Wesley College that exceeded the applicable VML of 0.6 mm/s PPV. 7 of 9

5 Conclusion This report summarises the results of the noise and vibration monitoring conducted by EHO Consulting at three locations around the Susan Wakil Health Building construction site. The monitoring results are considered against the requirements of the CNVMP. The monitoring results demonstrate that, despite some non-conformances in the monitoring procedures, measured noise and vibration levels were generally consistent with the NMLs and VMLs at both RPAH and Bosch 1B Laboratory Animal Services. Additionally, noise levels at Wesley College were consistent with those predicted in the CNVMP. Based on the results, it is considered that noise and vibration levels from the site are as envisaged by the approved CNVMP. As works continue, reasonable and feasible noise and vibration mitigation measures should be implemented on site as per the CNVMP. 8 of 9

Appendix A Measurement results 9 of 9

Royal Prince Alfred Hospital 23 September to 29 September 2018 1 of 19

Royal Prince Alfred Hospital 30 September to 6 October 2018 2 of 19

Royal Prince Alfred Hospital 7 October to 13 October 2018 3 of 19

Royal Prince Alfred Hospital 21 October to 27 October 2018 4 of 19

Royal Prince Alfred Hospital 28 October to 3 November 2018 5 of 19

Royal Prince Alfred Hospital 4 November to 10 November 2018 6 of 19

Royal Prince Alfred Hospital 11 November to 17 November 2018 7 of 19

Royal Prince Alfred Hospital 18 November to 24 November 2018 8 of 19

Bosch 1B Laboratory Animal Services 23 September to 29 September 2018 9 of 19

Bosch 1B Laboratory Animal Services 30 September to 6 October 2018 10 of 19

Bosch 1B Laboratory Animal Services 21 October to 27 October 2018 11 of 19

Bosch 1B Laboratory Animal Services 28 October to 3 November 2018 12 of 19

Bosch 1B Laboratory Animal Services 4 November to 10 November 2018 13 of 19

Bosch 1B Laboratory Animal Services 11 November to 17 November 2018 14 of 19

Bosch 1B Laboratory Animal Services 18 November to 24 November 2018 15 of 19

Wesley College 28 October to 3 November 2018 16 of 19

Wesley College 4 November to 10 November 2018 17 of 19

Wesley College 11 November to 17 November 2018 18 of 19

Wesley College 18 November to 24 November 2018 19 of 19