HC1100 GN1100 H990. Steaming Hot Water Tap. Filtered 98 C water on tap. Installation, Care & Use Manual

Similar documents
Instant Hot Water Dispenser Owner s Manual

Instant Hot Water Dispenser Owner s Manual

Instant Hot Water Dispenser Owner s Manual

Installation & Operating Guide

Installation & Operating Guide

Hot-1 Hot Water Dispenser

How your hot water dispenser works

multitap F-H3N1GDZL-3 F-H3N1GDZJ-3 F-H3N1GDZU-3 Installation, Care & Use ALL-IN-ONE TAP

INSTANT HOT WATER DISPENSER

SCHWAN INSTALLATION GUIDE

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

SCHWAN INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OSCILLATING WALL FAN. LISTED For Damp Location E ITEM # MODEL #JP18EB3. Español p. 15 ATTACH YOUR RECEIPT HERE.

Installation Instructions

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

Food Waste Disposer Instruction Manual

INSTALLATION INSTRUCTIONS

DISHWASHER INSTALLATION INSTRUCTIONS

Installation Instructions

Single-Control Lavatory Faucet

Installation Instructions

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

HOT TANK INSTALLATION AND OPERATING INSTRUCTIONS. Model #: 5000

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

WATERSHIELIJrM REVERSE OSMOSIS INSTALLA TION MANUAL ~ ~ ~ ~ ~ l ~ TO INSURE THIS PRODUCT AND THE INSTALLATION THEREOF. ~ ~ ~ ~ ~

Dishwasher. Installation manual DW60M9990AP

Installation guide Sahara & Sahara Plus

instant hot water dispenser filter system système de filtre sistema de filtro owner s manual manuel d utilisateur manual del usuario

Installation Instructions

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

Installation Instructions

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

The Danger signal indicates an immediately hazardous situation which, if not avoided, will result in death or serious injury.

Read All Instructions Thoroughly Before Installing or Using the Disposer.

Viking Installation Guide

PRE INSTALLATION PROCEDURES

Installation & Service Guide

Installation Instructions Built-In Dishwasher

Oahu Showerspa Model #1035 Owner's Manual

Installation Instructions

CEILING FAN LIGHT KIT

CEILING FAN LIGHT KIT

475 PRO SERIES Reverse Osmosis System Installation & Operation Manual

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Food Waste Disposer Instruction Manual

Installation Instructions Built-In Dishwasher

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

User s Manual and Operating Instructions

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

ST. KITTS CEILING FAN

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

IMPORTANT! ank You! Model: Twist-In 100 GPD, 3-Stage RO Unit. Installation, Operation & Maintenance Guide

DIGITAL INSTANT HOT WATER DISPENSER INSTALLATION INSTRUCTIONS

DOUBLE DISHDRAWER TM DISHWASHER

Installation Instructions

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

Single-Control Bathroom Sink Faucet

INSTALLATION INSTRUCTIONS

ELSTON 52 CEILING FAN

Installation Instructions

Installation Instructions

Installation Instructions

NIAGARA. Niagara ShowerSpa Model #1048B-BN Owner s Manual

INSTALLATION INSTRUCTIONS

2-Stage Under Counter Filtration System Model: WP-2 LCV

Installation Instructions

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Water Distiller Service Manual

Autofill counter top water boiler

Installation Guide. 1 & 3 Series Built-In Dishwashers. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Owner's Manual. Please read this document carefully before installing and/or using your vacuum cleaning system.

Installation Instructions

Installation Instructions 36 Inch Refrigerator

RECESSED LIGHT CONVERSION KIT

G-10f/GCG-10f UPRIGHT COOLER

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Installation Instructions Built-In Dishwasher

INSTALLATION. Glass Panel Doors (select models) CAUTION

MKTF CRO-Series 5-Stage Reverse Osmosis System Installation and Maintenance Manual

Installation Instructions

ELECTRIC FLAT PANEL FIREPLACE HEATER

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

CEILING FAN LIGHT KIT

Installation. Leveling

INSTALLATION GUIDE NZ AU

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Installation Manual PS-225 & PS-275

Transcription:

HC1100 GN1100 Steaming Hot Water Tap Filtered 98 C water on tap Installation, Care & Use Manual

WHT YOU SHOULD KNOW EFORE YOU EGIN For your satisfaction and safety, read all instructions, cautions, warnings and dangers before installing or using this steaming hot water tap. This particular unit is not intended for commercial use. Make sure that all electrical wiring and connections conform to local codes. standard, earth (grounded) electrical outlet is required under the sink for the tap s electrical power. The wall outlet powering your tap must have electrical power supplied to it continuously. This outlet must be fused and should not be controlled by the same wall switch that operates the food waste disposer. Fuse/circuit breaker required is 10 amp for 230 volt (10 amp for 22-240 volt UK). To ensure proper operation, this unit is not intended to be flushed with chlorine. If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system. In ustralia, all plumbing and electrical work must be completed by a qualifed tradesperson. To prevent damage or unit not operating properly, the water pressure must be between 172 kpa-862 kpa (1.7 bar - 8.6 bar; 25 psi - 125 psi). mbient (room) temperature between 1ºC and 38ºC. In ustralia, an ustralia water mark approved 350 kpa set pressure limiting value and dual check valve must be used. Moving parts inside the tank causing a rattling noise is normal. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. WHT YOU NEED TO GET STRTED Equipment Required: Drill Compression fitting, T-fitting or saddle valve djustable wrench Phillips and flat blade screwdrivers Pencil Tape Measure Level Equipment You May Need: nchors for drywall Hole saw asin wrench Hole punch If you intend to use the sprayer hole in the sink for the hot water tap, you may need a 3.18mm plug or a 6.35mm cap (not supplied) for the sink spray hose line. See Step 1-. If you need to cut a mounting hole in the stainless steel sink, you may need a hole punch or a 32mm - 38mm hole saw made for cutting stainless steel. What if you don t have a sprayer hole or don t want to use it? Many homeowners replace the soap dispenser in their sink with a steaming hot water tap. If drilling a hole into a stainless steel sink or counter top, you can cut a mounting hole for the tap with a hole saw for stainless steel, or you can use a hole punch. Hole size requirements: HC1100, a 35mm - 38mm hole is required. ll other models, hole requirement is 32mm - 38mm. Consult a professional before drilling into a surface other than stainless steel. 2

IN THIS PCKGE 9.5mm White Tubes (2) Y Quick Connector Rubber O-Ring 19mm Screws (4) Hex Nut HC1100 Quick Connector (1-2 Supplied) Semi-circular Mounting Plate John Guest Fitting (ustralia Only) Hex Tool Filter System Rubber O-Ring 19mm Screws (4) Hex Nut 9.5mm White Tubes (2) GN1100 Quick Connector (1-2 Supplied) Semi-circular Mounting Plate John Guest Fitting (ustralia Only) Hex Tool Filter System Semi-circular Mounting Plate Wing Nut Rubber Gasket 19mm Screws (2) John Guest Fitting HOW TO USE THIS INSTRUCTION MNUL These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process. 2 Property Damage: Check to make sure tubes are connected properly and are pushed in as far as possible. 3 3 Slip the clear tube over the far right smooth fitting and slide down approximately 12mm. (3) Visually check for pinched or crimped tubes. 1 1 2 3 Provides a step-by-step narrative describing the installation step, with check boxes that can be marked as you progress through the installation. Contains simple illustrations that provide visual instruction to support the narrative. CUTIONS, WRNINGS and DNGERS that will require your attention during the step. n imminently hazardous situation, which, if not avoided, will result in death or serious injury. potentially hazardous situation, which, if not avoided, could result in death or serious injury. potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. 3

STRT HERE PROPER INSTLLTION SHOULD TKE OUT 2-4 HOURS 1 PREPRTION Required minimum from Maximum counter center of hole to wall thickness (depth) HC1100... 100mm...76mm GN1100... 110mm...76mm... 50mm...76mm The wall outlet for your tap must have power supplied to it continuously and must be fused. It should not be controlled by the same wall switch that operates your food waste disposer. Identify locations for the tap, tank and filter (if applicable). Check to make sure there is proper clearance (see chart at left) for tap handles to be fully opened. Check to make sure counter is not too thick (see chart at left). Make sure there is an earth (grounded) electrical outlet under the sink. If you have to drill through sink or countertop, you may need to rent or purchase the appropriate tools. Turn off water supply. If using the sink sprayer hose hole, remove nut that connects sprayer hose at bottom of tap. Using adjustable wrench, remove nut connecting sprayer washer flange in sprayer hole. Plug hose opening with either a plug or a cap (not supplied). OVERVIEW OF COMPLETED SETUP 4

2 INSTLLING THE TP - SERIES 1100 HC1100 / GN1100 Unpack steaming hot water tap components. On a firm, flat surface, carefully straighten the copper tubing. Property Damage: Do not pinch or break copper tubing. Do not distort the last 1 inch of tubing. HC1100 / GN1100 Ensure that the black O-ring is properly seated in the base of the tap head (the groove on the underside of the tap). Make sure to use rubber O-ring to ensure proper seal. C HC1100 / GN1100 Feed tubes down through the hole in the sink or countertop until the base is at rest on the sink or countertop surface. n assistant may be needed to hold the tap head in place while securing the tap. D Semi-circular mounting plate should encircle all descending tubes and extend beyond sink hole when tight. HC1100 / GN1100 From under the sink, place the semi-circular mounting plate onto the threaded stud. Place hex nut onto the threaded stud. Ensure tap head is at desired angle. Insert screwdriver into hole on side of hex tool (creating a T ), and use tool to tighten nut and secure tap. 5

2 INSTLLING THE TP - Unpack steaming hot water tap components. On a firm, flat surface, carefully straighten the copper tubing. Property Damage: Do not pinch or break copper tubing. Do not distort the last 25mm of tubing. Ensure that the black rubber gasket is properly seated into the base of the tap head and will surround the sink mount. Make sure to use rubber gasket to ensure proper seal. Feed tubes down the hole in the sink or countertop until the base is at rest on the sink or countertop surface. C n assistant may be needed to hold the tap head in place while securing the tap. From under the sink, place the semi-circular mounting plate onto the threaded stud. Place wing nut onto the threaded stud. Make sure tap head is at the desired angle. Tighten the wing nut until snug, while ensuring the semi-circular mounting plate extends beyond the sink hole. 6

3 MOUNTING THE TNK Tank must be mounted level to ensure proper operation. Property Damage: Tank must be located within 400mm of tap and within 760mm or less of a standard earth (grounded) outlet. DO NOT extend plumbing or electrical lines. Select a spot under the sink to mount tank vertically within reach of both plumbing and electrical connections. Tank should be within 400mm or less of tap water lines and within 760mm or less of a standard earth (grounded) outlet. While holding tank in place on the spot selected for installation, use a pencil to mark locations for 2 hanging screws. Leave 12mm for hanging tank. Mount tank vertically in an area that allows clearance on the underside of the tank for drainage, if necessary. DO NOT over tighten screws. Screws provided are for use in wood studs or cabinets only. Use wall anchors (not supplied) for installation into drywall. Pre-drill 3mm pilot holes at marks. Turn screws into pre-drilled holes, leaving 6.4mm exposed. Hang the tank on the screws. Tighten the screws with only 1/2 turn clockwise. 4 CONNECTING TP TO TNK 1 2 Property Damage: Pinched or blocked water lines may cause damage to the water tank. Without depressing the gray button, place the snap-connect fitting at the end of the blue tube onto the left plastic fitting on the tank, pushing until it clicks into place. (1) Slip the flexible white tube over barbed middle fitting and slide down approximately 12mm. (2) Slip the small white tube over the far right smooth fitting and slide down approximately 12mm. (3) 3 Visually check for pinched or crimped tubes. Property Damage: Check to make sure tubes are connected properly and are pushed in as mentioned. Hose clamps are not needed for any of the connections. 7

INSTLLING FILTRTION Personal Injury: Do not locate filter above an outlet or other electrical device. Install head and bracket so that connections require no stretching, kinking or pinching of tubing. Filtration standard on HC1100 & GN1100 Optional on Mark hole locations for filter head and bracket in a spot that allows for filter replacement. Drill 3mm starter holes and attach bracket to wall with wood screws, turning until snug. Remove red filter cap, insert filter cartridge into filter head and twist clockwise until LOCK arrow on the filter aligns with arrow on bracket. from water supply line Property Damage: Tube runs need to form to the cabinet s contours to allow storage space with no sharp bends. Tubes need clean, perpendicular, burr-free cuts to ensure a true fit. C HC1100 from filter or water supply line GN1100 to tap from filter or water supply line Property Damage: Do not extend the copper lines farther than the 400mm provided. Determine length of tubing required, then cut to length making sure the cut is perpendicular and burr-free. Insert a white 9.5mm tube into inlet side of filter head until it stops. Press in again to ensure a secure fit. Insert the other white tube into outlet side of filter head until it stops. Press in again to ensure a secure fit. Insert the copper tube(s) from the tap into the 9.5mm to 6.35mm quick-connector. Press in again to ensure a secure fit. Connect the white tube from the right outlet on the filter head into the quick-connector until it stops. Press in again to ensure a secure fit. To remove tube(s) from quick-connector, depress the release ring and gently pull tube away. D discharge tube To redirect filter replacement water discharge, place 150mm clear tube over vent hole on the left side of filter head. from water supply line to tap It is normal for approximately 60 ml of water to discharge when filter is removed. 8

5 t FINL WTER CONNECTION UK/IRL US/NZ Property Damage: Join remaining tube to cold water supply only. HC1100 / GN1100 the other end of the white tube from the filter, press on the: (UK/IRL) 9.5mm to 15mm quick-connector and connect to a 15mm water supply. (US /NZ) 3/8" to 1/4" bspt John Guest fitting and connect to a female 1/4" bspt fitting water supply. Press in again to ensure a secure fit. t the end of the copper tube, press on the 1/4" to 1/4" bspt John Guest fitting and connect to a female 1/4" bspt fitting water supply. (not included) Press in again to ensure a secure fit. Property Damage: Join remaining tube to cold water supply only. 6 FILL TNK & THEN CONNECT POWER Turn on the cold water supply. Depress or twist the tap s HOT handle and hold it until water flows from the spout. Scalding Hazard: The tap dispenses water up to 98ºC, which can instantly cause scalds or burns. Use care when operating this appliance. Property Damage: standard earth (grounded) outlet within 760mm of the tap is required under the sink. Do not use an extension cord set with the tap. Run the water for at least 2 minutes to flush lines (both the hot and cold handles independently if applicable). Check all connections to ensure they are tight and that there are no leaks. Plug in tank and ensure that green light on front of tank is illuminated. Water will be cold at first. llow 12-15 minutes for water to reach target temperature. Gurgling or hissing is normal during the initial heating cycle. 9

Electric Shock Hazard: Using an ungrounded or improperly connected appliance can result in serious injury or death from electrical shock. This appliance must be earth (grounded). This steaming hot water tap is equipped with a cord that has a grounding conductor and earth ground pin. The plug must be connected to an appropriate outlet that is properly installed and earth (grounded) in accordance with all local codes and ordinances. Do not modify the plug provided with the appliance if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Check with a qualified electrician or serviceman if you are in doubt as to whether the steaming hot water tap is properly earth (grounded). Personal Injury: This tank is a non-pressurized tank. DO NOT modify this system. DO NOT close vent tube or connect other type taps or valves to the tank. Use only the InSinkErator tap supplied. Use only parts provided. Contact an authorized InSinkErator Service agent for repairs or replacement components. Tap: Tank: Fire Hazard: To minimize possibility of fire, DO NOT store flammable items such as rags, paper or aerosol cans near the tank. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Property Damage: To avoid water damage, replace any loose or split tubing. Periodically inspect the unit for any signs of leakage and immediately remove from service any unit suspected of leaking. steaming hot water tap, like any water heater, has a limited life and will eventually fail. To avoid possible property damage, this steaming hot water tap should be regularly examined for leakage and replaced when necessary. drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage. WRRNTY INFORMTION Series 1100, 2-year warranty, 1-year warranty 2-year warranty on stainless steel tank Covers all replacement parts and labour to correct defects in material or workmanship in the hot water tap system, excluding the replaceable filter cartridge, for the full warranty period from the date of installation in your home. If warranty service is required during the warranty period, contact an authorized InSinkErator service agent to replace or repair the unit in your home at no cost to you. If your tap is replaced rather than repaired, the warranty on the new unit shall be for the duration of the remaining portion of the original tap s warranty. Note: Warranty is determined by unit serial number and/or date of installation. Purchase or installation receipt may be required to verify warranty status. When service is required, and for the location of your nearest factory authorized service center, see attached service agency list. The foregoing warranty does not apply to damage or inoperation resulting from accident, alteration, misuse, abuse, improper installation, installation not in accordance with these instructions or local electrical and/or plumbing codes. We do not assume any responsibility for consequential damage. Install using genuine InSinkErator manufactured components only. Use of non InSinkErator components will void warranty. 10

CRE ND USE Electric Shock Hazard: To prevent electrical shock, disconnect power before servicing unit. Use only a properly earth (grounded) and polarized electric outlet. DJUSTING THE THERMOSTT Factory temperature pre-set is 96 C. To reset the thermostat to 96 C, turn the indicator one notch to the right of vertical. fter adjusting, depress or twist the tap handle for 20 seconds for water to re-heat to the new setting. approx. 96 C To adjust water temperature, turn thermostat dial on the front of the tank clockwise to increase temperature or turn counter clockwise to decrease temperature. Repeat if necessary. ll changes should be minimal. Scalding Hazard: Do not allow water to boil. May result in severe burns. SESONL STORGE/DRINGE nytime the steaming hot water tap is not used for extended periods of time, unplug and drain unit. If it is below freezing you will need to unplug the unit and drain it. Disconnect power from unit. Push hot water tap lever and allow water to flow until it is cool. Shut the cold water tap off at the valve. Remove drain screw located on bottom center of water tank and drain the water into empty pail. Empty the tank and then reinstall drain screw onto the bottom of tank, turning until snug. Do NOT over tighten. To place back in working order, fill tank with water and re-connect the plug. If unit has a filter, the filter must be removed, turned upside down to drain, and reinstalled. CLENING THE TP ND TNK Only use mild cleaners to clean the tap and plastic components. Cleaners with acids, abrasives, alkaline, and organic solvents will result in deterioration of the plastic components and void the warranty. FILTER GUIDE ND REPLCEMENT Replace filter cartridge when there is an obvious decrease in water flow to the tap or if there is an objectionable taste or odour to the water. When the inlet and outlet ports have been closed and the filter s internal pressure has been relieved, water (about 60ml) will discharge from vent line. If the new filter cartridge can not be inserted, insert the old one and turn until it stops, remove it and then retry the new cartridge. It is recommended that carbon filters be replaced every 6 months. Filter replacement instructions: Replace with an InSinkErator filter. Place pan or dish towel under the filter to catch water drainage during change. Slowly turn the cartridge counter-clockwise completely until it stops (1/4 turn). Pull cartridge straight down and discard. Insert new cartridge into filter head. Top surface of cartridge will become flush with the bottom of the filter head when fully engaged. Turn the cartridge clockwise until it stops (1/4 turn). lign the in/out arrow on the head and bracket assembly to the in/out arrow on the cartridge. Open tap to expel trapped air. Run water for 3 minutes before usage. PROPERTY DMGE Regularly inspect the unit for any signs of leakage. If there are signs of water damage, immediately remove the unit from service. To avoid water damage from leakage, replace all cut, loose or split tubing. drain pan, plumbed to an appropriate drain or outfitted with a leak detector, should be used in those applications where any leakage could cause property damage. 11

TROULESHOOTING PROLEM Water and steam spits forcefully from spout without turning on the tap. Water is not hot LED green light on front of tank does not illuminate Water is too hot or not hot enough Water comes out the vent instead of spout Water is dripping from the spout/vent intermittently Water is dripping from the spout/vent constantly POSSILE CUSE Unit is boiling. May be normal during initial setup. The unit may not be plugged in. The electric outlet is inoperative. The unit may not be plugged in. The electric outlet is inoperative. Thermostat is not adjusted to your needs. Outlet tube is blocked. The expansion chamber isn t draining properly due to low water pressure. The spout is blocked. Debris in the water line may be in the tap valve seat causing a slow water leak. WHT TO DO Depress tap lever to release some water from the tank. djust water temperature using dial on tank front. Remember that at higher altitudes, water boils at lower temperatures. Make sure the unit is connected to a properly earth (grounded) electric outlet. Make sure the circuit breaker or fuses are functioning properly. Check that the outlet is not switched off. Make sure that the circuit breaker or fuses are functioning properly. Check that the outlet is not switched off. djust the thermostat slowly, then depress or twist tap handle for 20 seconds to bring in fresh water to be heated at the new setting. llow 5-7 minutes for water to reach new temperature. Check that outlet tube is not kinked, twisted or pinched. Unscrew spout end piece and clean out any debris. Unplug the unit. If the dripping doesn t stop after a few minutes, check the supply valve to ensure that it is fully open and there are no obstructions in the water line reducing the pressure below 172 kpa (1.7 bar; 25 psi). i.e., a poorly mounted saddle valve, a clogged water filter, or a partially opened shut-off valve. Unscrew spout end piece and clean out any debris. Unscrew spout end piece and clean out any debris. Depress or twist lever 7-10 times to flush tap & lines. Divided stream Debris in the end piece. Unscrew spout end piece and clean out any debris. FILTRTION ISSUES Water taste or odour New filter doesn t fit The filter leaks No water flow or low water flow PN 43898 Filter water flow direction is wrong Filter needs to be flushed out Life of filter has expired Head and bracket not fully rotated Filter O-ring breach Head and bracket not fully rotated Filter O-ring breach Life of filter has expired Review filter tube connection instructions. Depress or twist the tap and run until the water is cold. If there is no change, replace filter cartridge Take out the new filter, put in old filter. Remove, inspect, reinstall filter cartridge. Test unit by reinstalling old filter and rotating to full stop. Check for leaks. Replace filter cartridge. See page 11.