AGRI-AIDE Ventilation Equipment. AGRI-AIDE Ventilation Key to Unlocking...

Similar documents
Chore-Time Fan Guide For Tunnel and Other Applications

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

SAFETY AND INSTALLATION MANUAL MODEL 8100

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

CEILING FANS THE PREMIUM QUALITY LINE FROM COMMERCIAL/INDUSTRIAL & SPECIAL APPLICATION. World Leader in Ceiling Fan Systems

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

Innovation & Energy Efficient VENTILATION SYSTEMS.

Ventilate Your Swine Nursery Building

Direct Fired Heater Model AD Specification

Control Strategies and Considerations for Livestock and Other Farm Buildings

8+* Bulletin No November 1997

Manure Pit Ventilation in Confinement Livestock Buildings

Cumberland Heating Systems

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

Evaporator EM-1. Features. V.1. Ceiling Mount Evaporators

and SHUTTERS Made to Work. Built to Last.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Panel Fan Series Operators Manual (Galvanized and Polymer)

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

5 year fan housing and motor warranty

KIC Air Curtains. Technical Guide

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

14" - 24" CLASSIC Direct Drive Fans

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

Ducted Propeller. Airflow Volume

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

SECTION AIR DOORS

Dairy Housing Ventilation Options for Free-Stall Barns H.K. House, P.Eng.

Natural Ventilation for Poultry

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

fans & heaters SIMPLE, ROBUST AND RELIABLE

Q-TEC QC-Series Chilled Water Air Conditioner

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

Caution: The fans must not be used in bath or shower enclosures.

HOG FINISHING FACILITY PERFORMANCE

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

Heat Exchangers in Swine Facilities

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ULTRA-SAFE Explosion-proof Duct Heaters

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

LUH HORIZONTAL FAN-FORCED UNIT HEATER

OFF-RIDGE VENTILATION PRODUCT BROCHURE

SECTION AIR DUCT ACCESSORIES

TOWER DRYERS TOTA TOT L VA AL V LUE. TOTA ALUE. TOT L SYSTEMS. AL SYSTEMS.

Selecting Fans and Determining Airflow for Grain Drying and Storage

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

ULTRA-SAFE Explosion-proof Duct Heaters

RESCOM 2100 HOT WATER BASEBOARD RADIANT HEATING Unique, slim-design baseboard radiators

Q-Tec TM QC-Series Chilled Water Air Conditioner

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Installation Instructions

Clean. Easy. COMPLIANT.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Gas-Fired Unit Heaters Commercial & Industrial

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

Description. Construction

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

MODELS B1PA024, 030 AND 036

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

KUH. Horizontal Unit Heater. Applications. Description

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Ventilation Basics How Do Your Pigs Feel? Amy Woods, DVM Rensselaer Swine Services, P.C.

COMBUSTION AIR SYSTEM

SUBMITTAL SCHEDULE & DATA

VERTICAL FAN COIL UNITS

IONIZING AIR BLOWER INSTRUCTION MANUAL

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

U n i t H e at e r s

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

Direct Gas-Fired Make-Up Air

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

SECTION AIR HANDLING UNIT

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

High Power Range Hood

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

G6RC Series TECHNICAL SPECIFICATIONS

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Brasch Hazardous Location Unit Heaters

2012 INTERNATIONAL FUEL GAS CODE VENTS

Modular Supply Make-Up Air Unit

Novel Livestock Housing Webinar A Novel Approach to Confined Calf Barn Ventilation

Cabinet Unit Heaters Steam / Hot Water

, 'I... " ENTILATION FOR SWINE / I / / I / I / UNIVERSITY OF flunois / I / SGRICULTUR~.uBRM~ '" ""'... I I \ / I I. , I \ CIRCULA~~G COpy I 1// 1\\

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Indoor Air Quality Product Brochure.

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Fans for Life! CA-TD0708. The World s Leading Producer of Air Movement Products

Packaged Terminal Air Conditioner (PTAC)

Transcription:

AGRI-AIDE Ventilation Equipment AGRI-AIDE Ventilation Key to Unlocking...

Osborne s world class ventilation equipment keeps indoor environments fresh and healthy for animals and the people who care for them. 2 www.osbornelivestockequipment.com

Ventilation From Pit to Peak - Osborne s Total Ventilation Systems Meet Your Needs Agri-Aide Ventilation from Osborne brings you solutions based on over 40 years of practical experience in creating comfortable, productive livestock environments. We offer equipment options to match any ventilation requirement and each component is built to provide long-lasting, trouble-free service. Ventilation Components Whether you manage pigs, poultry, dairy, or other livestock, fresh air is vital to the health of your animals, your staff and the financial health of your business. You can count on our experience with all types of buildings and animals to help you develop a complete ventilation plan or improve or maintain your existing system. Whatever your needs, we can deliver an integrated combination of exhaust fans, fresh air inlets, circulation fans, and reliable automatic controls that perfectly match your building. Slant-Wall Fans Air Duct High Pressure Fans Wind Diverters Super-Jet Circulation Fans Auto-MAX Ventilation Inlets Roof Cupolas PVC Shutters Controls Research with our air movement laboratory, our Demonstration Farm field tests, and our collaboration with leading universities have enabled us to harness state-of-the-art technology and offer you an efficient combination of ventilation components. Let us show you how we can simultaneously improve the air quality in your buildings and reduce your operating costs. www.osbornelivestockequipment.com 3

Slant-Wall Fans The design of Osborne s slant-wall fans expels condensation from buildings and keeps interior walls free from obstructions. These quiet, efficient and durable fans come in a full range of sizes and CFM ratings to perfectly match your applications. Exclusive Osborne RTM-Glas fiberglass housings maintain shape and rigidity over time, unlike inexpensive poly housings that warp or heat sag. Slant-Wall Fan Specifications Normal Fan Recommended Time Shipping 0.125 in. Catalog Voltage Power Fan Type Speed Diameter Delay Fused Switch Weight w.g. Number (volts) (RPM) HP kw in mm 120V 240V lbs kg cfm FV-SW0801V Variable Speed 1725 120/240 1/25 0.03 8 203 3A 2A 19 8.6 97 FV-SW0802V Variable Speed 1725 120/240 1/25 0.03 8 203 3A 2A 19 8.6 117 FV-SW1203V Variable Speed 1725 120/240 1/25 0.03 12 305 3A 2A 31 14.1 393 FV-SW1207V Variable Speed 1725 120/240 1/25 0.03 12 305 3A 2A 31 14.1 723 FV-SW1211V Variable Speed 1725 120/240 1/6 0.12 12 305 4A 2A 35 15.9 1221 FV-SW1619V Variable Speed 1725 120/240 1/6 0.12 16 406 4A 2A 45 20.4 2039 FV-SW1624V Variable Speed 1725 120/240 1/4 0.19 16 406 8A 4A 49 22.2 2540 FV-SW2030V Variable Speed 1725 120/240 1/4 0.19 20 508 8A 4A 60 27.2 3026 FV-SW2045V Variable Speed 1725 120/240 1/2 0.37 20 508 14A 7A 64 29.0 4352 FV-SW2460V Variable Speed 1725 120/240 1/2 0.37 24 610 14A 7A 74 33.6 5741 FV-FM3611V Variable Speed 850 120/240 1/2 0.37 36 914 14A 7A 148 67.1 7765 Slant-Wall and Flushmount Fan Replacement Motors Motor Model For Use on Osborne Fan Model Motor Model For Use on Osborne Fan Model REM-1100 SW0801V, SW0802V, SW1203V, SW1207V REM-5100 SW2045V, SW2060V REM-3100 SW1211V, SW1619V REM-5200 FM3611V REM-4100 SW1624V, SW2030V 4 www.osbornelivestockequipment.com

Ventilation Air Duct High Pressure Fan Ideal for pit exhaust, Osborne s 10-inch air duct fan keep moisture and gases moving down through flooring and away from your animals. This powerful high pressure fan is built with a specially designed motor and cast aluminum propellers that remain perfectly balanced and remain cleaner than others. For special tasks, duct fans can be used to move air through manifold ducts to keep fresh air where it is needed most. Catalog Number Fan Type Normal Speed (RPM) Air Duct Series Fan Specifications Voltage (volts) Recommended Time Power Fan Diameter Shipping Weight Delay Fused Switch HP kw in mm 120V 240V lbs kg FV-DF1000 Variable Speed 3450 120/240 1/6 0.12 9.75 248 4A 2A 20 9.1 Air Duct Series Fan Performance Catalog Number FV-DF1000 Static Pressure in. w.g. Airflow cfm 0.050 1227 0.125 1169 0.250 1058 Motor Model REM-3200 KV-DF2000 Air Duct Fan Replacement Motors For Use on Osborne Fan Model DF1000 DF1000 (includes motor and fasteners for through-bolt mounting) www.osbornelivestockequipment.com 5

EXHAUST EXHAUST DEFLECT Wind PRESSURE DEFLECT Wind Diverter Kits Wind can slow or stall exhaust fans, seriously affecting barn ventilation rates. This wind pressure problem can be especially severe in winter months when small or variable speed fans are operating at low speed. Adding a wind diverter greatly reduces wind pressure without interfering with exhaust rates in still air. Universal brackets fit any fan size or make! Osborne wind diverters are made of ultrastrong, RTM-Glas fiberglass reinforced plastic. Catalog Number Wind Diverter Diameter in mm Wind Diverter Specifications Largest Round Fan Hood Protected in mm Largest Square Fan Hood Protected in mm Shipping Weight lbs kg FV-WDK008 11.75 298 9.75 248 6.75 171 4.0 1.8 FV-WDK012 17.00 432 15.00 381 10.50 267 5.0 2.3 FV-WDK016 22.00 559 20.00 508 14.00 356 6.0 2.7 FV-WDK020 25.00 635 23.00 584 16.25 413 8.0 3.6 FV-WDK024 29.00 737 27.00 686 19.00 483 12.0 5.4 FV-WDK036 40.00 1016 38.00 965 26.75 679 24.0 10.9 FV-WDK058 58.00 1473 56.00 1422 41.00 1041 75.0 32.0 6 www.osbornelivestockequipment.com

Ventilation Super-Jet Circulation Fans Osborne Super-Jet fans power move air throughout buildings by creating a jet stream of beneficial air. Because of their super-circulation capacity, large, power-hungry, floor or basket fans are not necessary. These fans provide the proper mixture of barn air allowing a uniform amount of fresh air to reach each animal. Year around, Super-Jets help keep temperatures uniform, which encourages proper dunging patterns. Manufactured with rigid Osborne RTM-Glas fiberglass orifice housings, Super-Jets will not warp or heat sag, even after years of operation! High jet velocity creates a jetstream of beneficial air movement far greater than the Super-Jet s own output, as shown above. Proper mixture means fresh air is uniformly available dead air is eliminated! Catalog Number Fan Type Normal Speed (RPM) Super-Jet Fan Specifications Voltage (volts) Recommended Time Power Fan Diameter Shipping Weight Delay Fused Switch HP kw in mm 120V 240V lbs kg FV-S1620V Variable Speed 1725 120/240 1/6 0.12 16 406 4A 2A 33 15 FV-S2030V Variable Speed 1725 120/240 1/4 0.19 20 508 8A 4A 44 20 FV-S2460V Variable Speed 1725 120/240 1/2 0.37 24 610 14A 7A 58 26.3 Super-Jet Fan Replacement Motors Super-Jet Fan Performance Motor Model REM-3100 REM-4100 REM-5100 For Use on Osborne Fan Model S1620V S2030V S2460V Catalog Number 0 in. w.g. cfm FV-S1620V 2000 FV-S2030V 3000 FV-S2460V 6000 www.osbornelivestockequipment.com 7

Auto-MAX Ceiling Inlets Unlike four-sided quad inlets, Auto-MAX inlets provide unobstructed 360 delivery of fresh air so animals never suffer. Precalibrated at the factory, absolutely no adjustments are required ever! Our inlets automatically distribute a controlled flow of fresh air without drafts in the winter and make smooth, healthy transitions during spring and fall weather changes. No other inlets match Auto-MAX performance. Auto-MAX Ceiling Inlet Specifications Ceiling Joists Catalog Number Rough Opening* in mm Overall Dimensions in mm Shipping Weight X Y A (sq) B C (dia) lbs kg FV-CI1500 20.25 514 20.25 514 22.25 565 15 381 17 432 10 4.5 * A 17.25 (439 mm) diameter hole can be the rough opening for ceilings made of wood or comparable type smooth material capable of holding a screw. X Y Attic C Osborne Auto-MAX inlets for hallways and walls are also available. All Osborne inlets are made of corrosion-resistant structural foam for long, trouble-free service. B Inlet Housing Ceiling Joist Baffle A 8 www.osbornelivestockequipment.com

Ventilation Roof Cupolas The FC3000 fiberglass roof cupola provides an effective way to provide attic or loft air for all types of livestock confinement buildings. Molded from Osborne s RTM-Glas fiberglass reinforced plastic, the cupola can be used for either an air inlet or as an air outlet and readily stands up to harsh outdoor elements. It resists the entry of snow or wind-blown rain, and includes a plastic screen over the air passages to prevent bird entry. Catalog Number Roof Cupola Specifications Rough-In Dimensions in mm Maximum Airflow Shipping Weight Application W L CFM m 3 /h lbs kg FV-FC3000 Intake or Exhaust 12 305 46 1168 3000 5098 40 18.1 Metal Roof Cupolas provide an inexpensive and effective way to provide attic or loft air and are also available from Osborne. Construction is wood and galvanized steel with a white enamel exterior finish. Call Osborne Customer Service for more information on the Metal Roof Cupolas. L W Rough Opening Rafters Frame Supports www.osbornelivestockequipment.com 9

PVC Shutters Osborne s affordable all plastic shutters are perfect for replacing old metal shutters. Designed under Osborne s strict ventilation guidelines, the shutters are made of tough, exterior grade PVC blades and frames with fiberglass pivot rods. There is absolutely nothing on these shutters to corrode. Other PVC shutters, both square or rectangular, can be custom built to any specification. PVC Shutter Specifications Part Number Fits Square Fits Square Part Number in mm in mm KV-PS0011* 11 279 KV-PS0027 27 686 KV-PS0012 12 305 KV-PS0028* 28 711 KV-PS0013 13 330 KV-PS0029 29 737 KV-PS0014 14 356 KV-PS0030 30 762 KV-PS0015 15 381 KV-PS0032 32 813 KV-PS0016* 16 406 KV-PS0034 34 864 KV-NPS016* 16 406 KV-PS0036 36 914 KV-PS0017 17 432 KV-PS0375* 37.5 953 KV-PS0018 18 457 KV-PS0038 38 965 KV-PS0019 19 483 KV-PS0040 40 1016 KV-PS0020 20 508 KV-PS0042 42 1067 KV-PS0021* 21 533 KV-PS0044 44 1118 KV-NPS021* 21 533 KV-PS0046 46 1168 KV-PS0022 22 559 KV-PS0048 48 1219 KV-PS0023 23 584 KV-PS0050 50 1270 KV-PS0024 24 610 KV-PS0052 52 1321 KV-PS0025* 25 635 KV-PS0054 54 1372 KV-PS0026 26 660 NOTE: Starred (*) shutters fit standard Osborne Slant-Wall or Flushmount fans. Other sizes of shutters are made to order. Request availability and price for special sizes from Osborne Customer Service. 10 www.osbornelivestockequipment.com

Ventilation Thermostat & Single Fan Control Single stage heating and cooling thermostat (SSTW) Specifications: 16 Amps at 120 V 12 Amps at 240 V 40-100 F (4-38 C) range Water-tight corrosion-resistant NEMA enclosure Catalog #: FE-00SSTW Manual Motor Speed Control When used with the thermostat, many variations of control mode can be designed by Osborne. Specifications: MSCS-115: 4 Amps at 120 V MSCS-230: 4 Amps at 240 V Catalog #: FE-00MSCS-115 & FE-00MSCS-230 Multiple Fan Controls The AV-11 Variable Speed Fan Control cold starts motors at full speed. This means full fan horsepower overcomes fan and shutter inertia and avoids fan start-up stalling or cold weather freeze-ups. Controls many fans with the same horsepower. Specifications: 120/240 V, 11 Amps 35-95 F (2-35 C) range Minimum speed adjustment range 20% - 100% Catalog #: FE-00AV11 The family of e-vent Controls can regulate cooling, circulation, heating and curtains all in one control. Pay for only the features you need. Osborne Customer Service can assist in determining requirements. Specifications: 115/230 VAC, 10 Amps 32-112 F (0-44 C) range Catalog #: Call Osborne Customer Service to determine specifications. www.osbornelivestockequipment.com 11

Call us today to learn more about Osborne s ventilation equipment. Ventilation is one key to opening Single Source Swine Solutions. WORLD HEADQUARTERS 120 N. Industrial Ave. P.O. Box 388 Osborne, Kansas 67473 USA Toll Free: 800-255-0316 Phone: 1-785-346-2192 sales@osborne-ind.com www.osbornelivestockequipment.com 2012-2016 Osborne Industries, Inc. MS-0449_A