13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Multi line separator module

Input module, input/output module

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Output module (230 V)

FDOOT221, FDO221, FDT221

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Input module, input/output modules

Mimic display driver, LED ribbon cable

FDOOT241-9, FDOOT241-A, FDO241, FDT241

OH720, OP720, HI720, HI722

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FDOOT241-A9-Ex Multisensor fire detector

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

ASA linear smoke detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DM1131 / DM1133 / DM1134 Manual call points

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Fire control panels FC360

FDCL221-Ex Line adapter (Ex)

Radio fire detection system

FDCL221-M Multi line separator module

FDBZ290 Air sampling smoke detection kit

FDBZ290 Air sampling smoke detection kit

SWING radio fire detection system

Fire control panel for modernization

OOH740-A9-Ex Multisensor fire detector

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FDCIO223 (ES 45) Transponder

DT1101A / DT1102A / DO110xA Automatic fire detectors

OOH740, OOHC740 Automatic fire detectors

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Electronic timeswitch

OOH740-A9-Ex Multi-sensor fire detector

Fire control panels FC726 FC726-XA

FT2080 Fire terminal (Touch) Mounting Installation

Room thermostat with 24-hour time switch and large LCD

FT2080 Fire terminal (Touch) Mounting Installation

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Test units and accessories

FDS229 Alarm sounder with supplementary optical indication Technical Manual

FC2020 Fire control panel

FDCW241 Radio gateway Mounting

Call stations and extensions

DC1192 Input /Output module

Test units and accessories

FC722 Fire control panel

Frost Protection Thermostat

FC722 Fire control panel

FC724 Fire control panel

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDM273 Radio manual call point Mounting

FC723 Fire control panel

FC724 Fire control panel

FDBZ290 Air sampling smoke detection kit Technical Manual

Room Temperature Controllers

FDA241, FDA221 Siemens ASD

DF1101-Ex Infrared flame detector

1592P01. for liquids in piping DN

FDCL221 Line separator

FP120-Z1 Power supply kit A (70 W) Technical Manual

Room thermostats with LCD RDD100..

FDA241, FDA221 Siemens ASD

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Duct Temperature Sensors

FS20 Fire detection system

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room thermostat with independent DHW control

Flush-mounted room thermostat

Room Temperature Controller

Room thermostat with Auto Timer, independent DHW

RVL479. Heating Controller. for use with a partner unit

FDOOT221, FDOOT241-A3, FDOOT241-A4, FDOOT241-8, FDOOT241-9, FDOOT241-A9, FDO241, FDO221, FDT241, FDT221 Automatic fire detectors Technical Manual

FDL241-9 Linear smoke detector Mounting Commissioning

DOW1171 / DCW1151 Radio fire detection system

Test units and accessories

XC10 Extinguishing control panels

Frost Units for air temperature monitoring

Semi flush-mount room thermostats

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

DF1151-Ex Infrared flame detector

Room Temperature Sensors

Wall-mounted room thermostat with LCD

Cerberus FIT conventional system

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Flush-mounted room thermostats

Intellia Sounder Bases and Sounder Beacon Bases

Wireless room thermostat with LCD

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

FDCI221, FDCIO221 Input module, input/output module Technical Manual

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

Sinteso TM product catalog.

Transcription:

Sinteso Interbases FDSB221, FDSB228, FDSB229 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector bus FDnet Addressed (FDnet) 11 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 83 dba Compatible with all addressable Sinteso point detectors Supply and communication via FDnet Also included with the FDSB228: 13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 91 dba Meets the requirements of the EN 54-23 standard White LEDs with two adjustable luminous intensities: light/high (Class 'C-3-5') and dark/low (Class 'O-1.5-2.4') in accordance with EN 54-23 Also included with the FDSB229: Red LEDs with adjustable luminous intensities 3 programmable levels 2018-12-20 Control Products and Systems

Properties Use Intended use Supply via FDnet, no auxiliary supply required Integrated line separator Adjustable sounds and sound levels, sounds synchronized for all alarm devices Synchronization of the optical signal for the same alarm device type: All FDSB221, FDSB229 can be synchronized with one another All FDSB228 can be synchronized with one another Protected electronics and high-quality components Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be easily separated If a point detector is not used, then the blanking plate FDBZ296 (accessory) can be mounted Hotel rooms Restrooms Offices The interbases are intended to be mounted in a detector base from the 'Sinteso' product line. Only point detectors from the product line 'Sinteso' or the blanking plate FDBZ296 can be used in the interbases. Do not mount an alarm sounder or other alarm devices into the interbases. Functions Functions shared by all interbases The interbases provide an alarm in an addressed fire detection system FS20. They activate an acoustic signal in the event of a fire alarm. The interbases each have their own device addresses and can be configured independently of an point detector if one is in use. All point detectors in the series Sinteso FD20 can be used in the interbases. External alarm indicators can even be connected to the point detectors when using the interbases. Sounder beacon interbase FDSB228 In the event of a fire alarm, the sounder beacon interbase FDSB228 activate both an acoustic and optical alarm signal (with the white LEDs flashing). Sounder interbase with supplementary optical indication FDSB229 In the event of a fire alarm, the sounder interbase with supplementary optical indication FDSB229 emits both an acoustic and optical alarm signal (with the red LEDs flashing). 2

Type Overview Type Designation Order number Weight [kg] FDSB221 Sounder interbase S54372-F16-A1 0.195 FDSB228 Sounder beacon interbase S54372-F17-B1 0.204 FDSB229 Sounder interbase with additional optical indicator S54372-F17-A1 0.204 Accessories Type Designation Order number Weight [kg] FDBZ296 Blanking plate including validation seal sign S54372-B15-A1 0.031 FDBZ291 Designation plate A5Q00002621 0.002 FDBZ293 Detector locking device A5Q00005035 0.001 FDBZ297 Detector base seal S54372-F18-A1 0.020 LP720 Detector locking device S54319-F9-A1 0.001 Product documentation Document ID Title 007775 Data Sheet Detector bases and accessories FDB22x, FDB20x, FDB241, FDB251, FDB281, FDB299 008164 Equipment overview Sinteso Detector system FD20 008331 List of compatibility (for 'Sinteso ' product line) A6V10320090 Technical manual Sounder interbase FDSB221, Sounder beacon interbase FDSB228, Sounder interbase with supplementary optical indication FDSB229 Related documents such as the environmental declarations, CE declarations, etc., can be downloaded from the following Internet address: https://siemens.com/bt/download 3

Notes Mounting The interbases FDSB221, FDSB228, and FDSB229 form a single unit together with the point detector and are mounted on a detector base FDB221 or FDB222. FDBZ297 FDB221 FDB222 FDBZ291 FDSB221 FDSB228 FDSB229 FDBZ293 FDBZ296 1 FDBZ293 Mounting the interbase and accessories 1 Seal label 4

Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Technical data Supply Operating voltage DC 12 33 V Operating current (quiescent) Max. 250 µa Sound activated FDSB221/FDSB229: 3.5 ma FDSB228: 3.7 ma (120 mw) Optical indicator activated FDSB228: 3.0/7.4 ma (65/116 mw) (dark/light) FDSB229: 1.5/4.0/6.5 ma (dark/medium/light) Optical indicator and sound activated FDSB228: 5.8/10.2 ma (165/220 mw) (dark/light) FDSB229: 5.0/7.5/10.5 ma (dark/medium/light) Functional data Sounds FDSB221/FDSB229: 11 FDSB228: 13 2 alarm levels 2 sound levels (1 alarm sound level, 1 test sound level) Sound level (alarm sound level) FDSB221/FDSB229: 77 83 dba FDSB228: 79 91 dba Luminous intensity FDSB228 in accordance with EN 54-23: light/high C-3-5 dark/low O-1.5-2.4 (ceiling mounted, cylindrical cover cap as in Class C) Luminous intensity levels Communication protocol System compatibility FDnet Color FDSB229: 0.9 3.2 cd FDSB228: 2 levels (not available with all control panels) FDSB229: 3 levels, 2 flashing modes (not available with all control panels) FDnet FS20 ~ RAL9010 pure white / translucent 5

Line connections Connection terminals 0.2 1.5 mm 2 Ambient conditions and protection category Protection category (IEC 60529) with detector base seal FDBZ297 IP21C (with point detector) IP21C (with FDBZ296) Operating temperature FDSB221/FDSB229: -25...+65 C FDSB228: -25...+55 C Storage temperature -30...+75 C Air humidity 95 % rel. Standards, directives, and approvals Standards EN 54-3, type A, EN 54-17 EN 54-23 type A, Class C and O (FDSB228 only) Approvals VdS FDSB221: G211081 FDSB228: G216030 FDSB229: G211082 6

Dimensional drawings Interbase FDSB22x 121.8 Interbase FDSB22x with blanking plate FDBZ296 121.8 45.2 53.7 7

11 0786 FDSB221 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10320090 FDSB221 - Sounder incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-3 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-21098; DoC No.: CED-FDSB221 16 11 0786 FDSB228 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10320090 FDSB228 - Visual alarm devices / Sounder Type A incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-3 / EN 54-23 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-21498 ; DoC No.: CED-FDSB228 0786 FDSB229 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. A6V10320090 FDSB229 - Sounder incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-3 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-21099; DoC No.: CED-FDSB229 Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2010 Technical specifications and availability subject to change without notice. 8 Document ID Edition 2018-12-20