NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

Similar documents
NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

+ 25% Blue Energy adiabatic panels SMART COOLING. will reduce up to 30% of your cooling systems energy consumption!

The SMART COOLING adiabatic precooling panels will reduce up to 30% of your cooling systems energy consumption!

HYBRID ADIABATIC Cooling System

IntrCooll. Cool large buildings at 80% lower running costs

High-Pressure Atomizing System

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

ULTRATEMP HIGH PERFORMANCE HEAT PUMP

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Improving the performance of Air Cooled Chillers, Dry Coolers and Refrigeration Plants

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

PREFERRED SERIES AIR CONDITIONERS

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

PERFORMANCE IMPROVEMENT OF SPLIT AIR CONDITIONER USING EVAPORATIVE COOLING METHOD IN THE CLIMATIC CONDITION OF GUWAHATI, ASSAM

Product catalogue 2014 INNOVATIVE IDEAS FOR SMART SAVING

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

ECOMax-HE Automatic Tube Cleaning System

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Oxyvap Evaporative Cooling Applications

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

INTELLIGENT HUMIDIFICATION. Two adiabatic humidification methods intelligently combined Condair DL. Humidification and evaporative cooling

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

Refrigeration air dryer

High quality compressed air from generation to application

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Infinity 19 Heat Pump with Puron Refrigerant

ADVANCE TECHNOLOGIES FOR ADIABATIC COOLING AND HUMIDIFICATION Nortec Humidity, Inc. Fred Valentini Direct Room Systems Regional Manager Randall

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Data Centre Cooling Solutions

Cozy Hi Wall Inverter Air conditioner

Product Line Introduction. Karl Zhang Technical support engineer

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Cozy Hi Wall Inverter Air conditioner

Data Centre Cooling Solutions

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

RIGID DC LIQUID CHILLER

HEAT PUMPS. Complete Comfort and Energy Savings, Plus Exceptional Service From Your Bryant Dealer. Models 226A & 225B. Qualifying systems only

COASTGUARD AIR CONDITIONERS

AND WORRY-FREE PERFORMANCE

COASTGUARD HEAT PUMPS

TrilliumSeries Condenser 1 TRILLIUMSERIES CONDENSER 10 ECOFLEX CONTROLS 11 SELECTION AND PAYBACK ANALYSIS SOFTWARE 3 BENEFITS 8 MODES OF OPERATION

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

GEOTHERMAL DESIGN GUIDE

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

White paper Compressed air drying

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

AACH50 1/2 HP GALLONS (200 TO 1200L) INSTRUCTION MANUAL

AZ(P)Y1 SERIES. Johnson Controls - Hitachi Air Conditioning AIR COOLED SCREW TYPE-WATER CHILLERS. R134a. Manufactured by:

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

Infinity Series Condensing Gas Furnaces

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

Perfect Solutions for Cleaner, Fresher Indoor Air

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

The next level of energy efficiency and flexibility

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

AND WORRY-FREE PERFORMANCE

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

COOLflow 4E PRODUCT RANGE

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Minnesota Heating & Air Conditioning - Bryant Evolution 90+% Heating Systems.pdf EVOLUTION SYSTEM 90+% GAS FURNACES Complete Comfort, Energy Savings,

Downstream Equipment. Intelligent Air Technology

AKIMist E Dry Fog Humidifier General Installation Manual

Pure Efficiency Meets Healthy Living NEW 2013

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Reach-In. PLanT GROWTh. Reach-In

Aquaflair TRAC-TRAF-TRAH

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

Compressed air and compressed gas technology. Compressed air processing without compromises

Hansol Hi Wall Inverter Air Conditioner

9700 SERIES GAS FURNACES napoleonheatingandcooling.com

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

SERVICE ASSISTANT OVERVIEW FDSI Online Training

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

50A KP 70A KP 90A KP 120A KP 150A KP 210A

The Energy Mist System

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

EN aquatech.piovan.com

MODULAR CHILLER. R410a R22

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

DAIKIN Modular Inverter Air Cooled Chiller

WHYNTER Eco Pure Air Purifier

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Contact-Cooled Rotary Screw Air Compressors. R-Series kw ( hp)

Innovation for a Better & Greener Future

HEPA Air Purifier with Ion Flow Technology

PART 1 - GENERAL 1.1 WORK INCLUDED

Transcription:

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM H Y BRID COOLING Reduce chiller energy consumption by up to 37 % Increase chiller cooling capacity by up to 41% Achieve 100% protection for the condensers For all types of air cooled condensers and cooling equipment www.smartcooling.us

REDUCE CHILLER 37% Energy Consumption by UP TO INCREASE CHILLER Cooling Capacity by UP TO 41% PROTECT CHILLER 100% Condensers & Compressors SWISS INTEGRATED ENERGY TECHNOLOGIES New generation in adiabatic pre-cooling Using chiller booster, new generation intelligent adiabatic pre-cooling system with cooling devices, two technologies are merged, providing the highest performance indicators. This ensures 100% safety to the condensers from environmental hazards and exposure to water. Smart Cooling components completely avert corrosion and limescale (calcium and mineral deposit) formation risk on the condensers. We take full responsibility for every Smart Cooling component.

WHAT IS SMART COOLING? Smart Cooling reduces chiller energy consumption by up to 37%, increases the coefficient of cooling performance by up to 41% and protects chiller compressors, condensers and heat exchangers. New generation intelligent adiabatic precooling system kit is suitable for all types of air cooled chillers, dry cooling condensers, heat exchangers, rooftop units and refrigeration units. CHILLER BOOSTER KIT INTELLIGENT ADIABATIC PRE-COOLING SYSTEM Provides condenser pre-cooling, cools down intake air by using new generation technologies. Smart Cooling reduces gas pressure in chiller gas circuit, thus minimizing compressor load, increases COP, reduces energy consumption. Protects condensers from rust, calcium and mineral deposit (limescale), dust and direct sun light. Our new generation intelligent controller analyses chiller load, gas pressure, air temperature, air humidity, fan algorithm. Provides four step water treatment: No mineral deposit risk on condensers and pipes. Smart Cooling is a modular system that provides easy installation with all chiller types and manufacturers. Unique technology provides minimum water consumption, with higher evaporation efficiency. Chiller Smart Cooling system Chiller + Smart Cooling = higher efficiency

HOW DOES IT WORK? NE S ME MB RA I AB AT IC AD TIC BA A I AD Chiller booster Smart Cooling combines adiabatic evaporative pre-cooling process and condenser protection, mechanical air filtration. The intelligent adiabatic system Smart Cooling is mounted externally in front of condensers of the cooling equipment, thus the adiabatic process takes place before the mechanical cooling process in the cooling equipment. Using processed water Smart Cooling sprays very fine water mist, evaporates instantly. This reduces the temperature of condensation temperature in the cooling circuit. ES AN R MB ME SMART COOLING TECHNOLOGY Smart Cooling adiabatic membranes Higher chiller efficiency with lower energy consumption. New generation in adiabatic pre - cooling 30XA FLOODED COOLER PACKAGED AIR-COOLED CHILLER RATINGS TABLE - SI (count)

FURTHER ADVANTAGES 1 2 3 4 5 6 Reduces chiller energy consumption by up to 37% Increases chiller cooling capacity by up to 41% Protects chiller condensers and compressors Increases the service life of chillers Minimum water consumption RETURN ON INVESTMENT- 5-24 months Smart Cooling in action. With an intelligent adiabatic pre-cooling system, chillers can work even in extreme conditions, delivering high efficiency with minimal water consumption. INTELLIGENT CONDENSER PROTECTION NO MINERAL DEPOSIT RISK ON THE CONDENSERS NO LEGIONELLA RISK IN THE WATER 100% CONDENSER PROTECTION Chiller protection is one of the most important Smart Cooling elements. Smart Cooling provides, Full condenser protection from limescale (calcium and mineral deposit) formation, rust and direct sunlight. Smart Cooling Protects cooling equipment condensers and compressors from overheating. It also enables the operation of cooling equipment in extreme environments, where ambient air temperatures reach as high as 55ºC. Smart Cooling provides highest efficiency and reduces the load on compressors and the runtime thereof. Smart Cooling ensures the fastest investment return in the industry.

SMART COOLING COMPONENTS 1 CHILLER BOOSETER UNIT PRO 10 The high-pressure chiller booster unit pro 10 UV provides 70-140 bar pressure within the Smart Cooling system. The pump station houses a specially developed highpressure pump, valves, the electronics for the automated operation of the system and a block of ultra violet lamps. The UV lamps purify and sterilize the water to protect against bacteria, including Legionella. 2 HIGH PRESSURE MISTING NOZZLE PANEL Panels with misting nozzles are mounted externally in front of a condenser. Micro nozzles create a mist wall. The mist is sprayed in front of the condenser, the mist comes into contact with hot air and evaporates instantly (water that has not instantly evaporated settles on the membrane (pre filter) and continues to evaporate). When the water evaporates, the temperature of the condenser intake air is lowered. The cooled air is then fed into the condenser with the cooling fan. 3 CONDENSER PROTECTING MEMBRANE The membrane (pre filter) protects the condenser from limescale (calcium and mineral) deposits, the membrane does not allow the water mist to come into direct contact with the condenser. Membrane captures water mist, direct sunlight, dirt. It is self-cleaning. The special cell material does not create additional resistance to the air flow through the condenser.

SMART COOLING COMPONENTS 6 WATER RECIRCULATION MODULE Water recirculation module ensures 100% water usage and recirculation. The recirculation unit accumulates the non-evaporated water, re-filters it and returns the water back to the adiabatic system. 4 WATER TREATMENT SYSTEM Smart Cooling component has 4 steps of water purification: calcium carbonate and mineral elimination; protection against algae and bacteria, including (Legionella); fine water treatment up to 5 microns. The water purification module ensures that the pipes and other components are protected from the formation of limescale on the surface. 5 CONTROL UNIT INTELLIGENT ADIABATIC SYSTEM PROCESSOR PRO 1 has seven steps of operation, which allows to use water efficiently at various air and chiller load parameters. The software adapts operating modes to all climatic zones. PRO 1 analyzes chiller load, analyzes outdoor air temperature and humidity HR%, processes this data and switches the adiabatic system on or off in such a way that provides the best efficiency. The processor controls the operation of the adiabatic system in such a way as to spray the precise amount of water that can evaporate.

SECURITY / WARRANTY NO LIMESCALE (CALCIUM AND MINERAL DEPOSIT) FORMATION RISK ON THE CONDENSER Water before it gets used in the intelligent adiabatic evaporative pre-cooling system Smart Cooling is treated with special biochemicals changing the structure of calcium carbonate molecules so that it does not stick to surfaces and does not create limescale deposit. NO LEGIONELLA RISK IN WATER MIST System is equipped with UV sterilizers thus providing that all bacteria (including Legionella) in water is eliminated. 100% CONDENSER PROTECTION FANS PRESSURE DROP IS 1-3% Condenser protection from deposits, dirt and direct sun rays is especially important for the cooling system. Smart Cooling protective membranes protect the condensers of the cooling equipment. The cleaner the condenser of the cooling equipment is, the better the heat exchange and heat removal from the condenser processes take place, therefore condenser protection is of great importance. Protection ensures cooling equipment longevity and higher efficiency (EER). Adiabatic panels ensure air pre-cooling and prevent cooling equipment from overheating. Using Smart Cooling does not reduce airflow and does not create additional resistance. The cleanness of the heat emission radiators is preserved, thus ensuring low exit temperatures and reduced pressure in the whole system. In such a way, servicing frequency and the number of emergency calls are considerably reduced, which may have a direct influence on the maintenance budget, not to mention safety and durability. Pressure drop is 1-3%.

HIGHER COOLING EFFICIENCY with lower energy consumption EASY TO SET-UP MODULAR SYSTEM Smart Cooling is delivered in a kit form, which can be installed both on new or already functioning cooling equipment, for any air conditioner or cooling equipment model or manufacturer. Smart Cooling is mounted externally in front of condensers of cooling equipment, without any impacts or changes in the interior of the cooling equipment and no effect on the manufacturers warranties. INCREASED EQUIPMENT SERVICE LIFE In addition to air-cooling the new intelligent adiabatic evaporative pre-cooling system Smart Cooling decreases the basic pressure in the compressor. Decrease of pressure and temperature essentially increases service life of the compressor. Since Smart Cooling considerably reduces excessively high discharge pressure and cooling cycle temperatures, the mechanical stress of the system is considerably reduced, which means safe exploitation and decreased need for maintenance.

SMART INNOVATION IN ADIABATIC PRE-COOLING PERFORMANCE 50% 40% 30% 20% 10% Increased cooling % Increases chiller performance (COP) and reduces energy consumption. Reduced energy consumption % By using the precision simulation program, we accurately determine the expected results for each chiller. Thanks to Smart Cooling high-precision calculations and hybrid cooling technology, chillers will provide the highest EER and COP ratings, which will significantly reduce energy consumption and costs. Smart Cooling KIT is for chiller retrofit and for new chillers as well. One KIT is suitable for all types of air cooled chillers and condensers.

INTELLIGENT TESTED SAFE

SMART COOLING OPERATE IN 45 COUNTRIES WWW.SMARTCOOLING.US Recognitions and awards: Adiabatic system Smart Cooling can be installed on all condensers of all major manufacturers. 2015 Smart Cooling. All Rights Reserved. Smart Cooling is a trademark owned by SWISS INTEGRATED ENERGY TECHNOLOGIES AG. or its affiliated companies. All other trademarks are property of their respective owners.