Natural Gas Appliance Testing Action Guidelines (Non ESA/Low Income 5 )

Similar documents
Whole House Action Guidelines

Whole House Combustion Appliance Safety Test Procedure for Pacific Gas and Electric Company (PG&E) Advanced Home Upgrade 2019

Combustion Appliance Safety Testing Guidelines

What is the purpose of the Make Safe Procedure (MSP)?

QUALITY CONTROL INSPECTION GUIDELINES V6.0

Southern California Edison and SoCalGas Energy Upgrade California Home Upgrade. SoCalGas

Section 42. Lead Paint Risk Factor NONE WATER HEATER STORAGE GAS

State of ALASKA, Weatherization Assistance Program. Technical Support Document. Combustion Safety

Inspection Checklist Mechanical Rough in

SAN DIEGO GAS AND ELECTRIC AND SOCALGAS ENERGY UPGRADE CALIFORNIA HOME UPGRADE QUALITY CONTROL INSPECTION GUIDELINES V7.0

HOME INSPECTOR EDUCATION EXPO 2016

Inspection Checklist Mechanical Final

Summary of Changes to the ESA Program California Installation Standards Manual dated December 2014 (as of 10/30/17)

RESNET National Conference New Orleans, LA. February 16, 2009 Presented by Rich Moore Invisible Energy Denver, CO

Combustion Safety. RESNET Conference San Antonio, TX February 27, Presented by Rich Moore Lightly Treading Energy & Design Denver, CO

COMBUSTION SAFETY BASICS

Gas Safety. Syllabus. For. Gas Appliance Service. Certificate of Qualification Examination. (Formerly Class C)

Second Revision No. 3 implements the text of Committee Input No. 36 as proposed in the First Draft Report, along with the following amendments:

Carbon Monoxide Safety Information

CHAPTER 9 SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL BURNING EQUIPMENT

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Carbon monoxide (CO) is a colorless, odorless gas that is the product of incomplete combustion of carbon-based fuels.

Building Department Informational Handout

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

TABLE OF CONTENTS. Part I Administrative... 1

RESNET National Conference New Orleans, La. February 15, 2009 Presented by Rich Moore Invisible Energy Denver, CO

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Montana Weatherization Program WEATHERIZATION FINAL INSPECTION REPORT (Mobile Homes) Client Name Address Contact phone # Inspector Name and QCI#

Canadian Property Inspections

The Heating System and Ventilation and Combustion Air

Manhattan Fire Protection District

USER S INFORMATION MANUAL

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

2015 MECHANICAL CODE REQUIREMENTS

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

PLP - TERMS AND CONDITIONS Philadelphia Gas Works Residential Parts & Labor Plan Contract

USER S INFORMATION MANUAL

HVAC Equipment Access Equipment Location

Notable Changes in the Mechanical Codes

Incident Summary #II (#8165) (FINAL)

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

Indiana WX Oil Furnace Inspection Guide

Uniform Dwelling Code 2017 Updates SPS 323

USER S INFORMATION MANUAL

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

I. STRUCTURAL SYSTEMS

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

C O D E S & A M M E N D M E N T S

BPI ANALYST ENVELOPE AUDIT FIELD EXAM CHECKLIST

Introductions HERS Industry HERS Ratings ACCA Standard 12 Resources

TABLE OF CONTENTS. Part I Administrative

Pro-Tech Home Inspections

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

SAFETY AND MAINTENANCE TIPS FOR NATURAL GAS USERS FROM THE VILLAGE OF DIVERNON

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

BEST DRAFT CONTROL: MANUAL DAMPERS IN MULTIPLE BOILER SYSTEMS

Steve Ramsey Home Inspections

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

Integrated Ventilation System

INSTALLATION AND SERVICE MANUAL

Family Foster Home Fire Safety Evaluation Checklist Instructions

Fuel Oil Heating Installation Inspection Report #1 2008

SPECIFIC APPLIANCES CHAPTER 6

INSTALLATION AND SERVICE MANUAL. Hot Water Heating Boilers Domestic Hot Water Supply Boilers 399, ,000 Btu/hr Models

X-593 SOLID FUEL HEATING QUESTIONNAIRE

WARNING FIRE OR EXPLOSION HAZARD.

Knowledge Objectives (2 of 2) Fuel Gas Systems. Skills Objectives. Introduction. Fuel Gas Systems (1 of 6) 12/20/2013

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

CHAPTER 8 CHIMNEYS AND VENTS

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

e. Potential sources of air contaminants do not exist near the building. (e.g. chimneys, stacks, industrial plants, exhaust from nearby buildings)

PLUMBING & CARBON MONOXIDE

Bay Wide Commercial and Home Inspection Thackeray Avenue/ Mail address Hayward, Calif TH AVENUE SAN LEANDRO, CALIFORNIA

SPECIFIC APPLIANCES CHAPTER 6

Spray Polyurethane Foam and Open-Combustion Appliances

NC Department of Insurance Office of the State Fire Marshal - Engineering Division 1202 Mail Service Center, Raleigh, NC

SPECIFIC APPLIANCES CHAPTER 6

Bosch 80% AFUE Gas Furnace BGS80 Model

4. A 2 X4 knee wall, if insulated, should be to what R value? 5. The clearance between insulation and a furnace vent should be:

SUMMARY 1234 Main St.Severn Buyer Name 07/18/2018 9:00AM

The Village of Franklin Gas Safety Pamphlet

Do not use this vent pipe or fittings for venting incinerators of any kind.

Inspection Checklist Residential Mechanical Rough In July 2016

OIL-FIRED CENTRAL FURNACE

AUTOMATIC MAKE-UP AIR DAMPER WITH TRANSFORMER READ AND SAVE THESE INSTRUCTIONS

2012 INTERNATIONAL FUEL GAS CODE VENTS

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

Retrofit Installer-Mechanical

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

PART 5: HVAC & DHW SYSTEMS

FIRE PREVENTION. Consider installation of a fire sprinkler system.

Objectives. Home Performance Diagnostics with the House of Pressure (Part 1) How can Pressure effect Building Performance?

ML180UH SERIES GAS FURNACE WARNING WARNING

Transcription:

Natural Gas Appliance Testing Action Guidelines (n ESA/Low Income 5 ) The purpose of these Action Guidelines is to describe the actions participating contractors and/or inspectors should take in the event they encounter a safety issue. Gas Service Representative (GSR) Call Procedures: Participating contractors may attempt to repair any conditions that caused a Combustion Appliance Safety (CAS) test to fail provided they are properly licensed to do so. If the participating contractor is unable to repair any conditions that caused a CAS test to fail, the participating contractor must call a PG&E Gas Service Representative (GSR) as required by the Action Guidelines below. If a GSR call is required, contact the GSR immediately (before leaving the customer s home). To contact the GSR and schedule a visit, the participating contractor must call PG&E Central Inspection Program (CIP) Dispatch at 1 800 813 1975 during normal business hours ( M F 8:30am 5pm). After Hours call PG&E Central Inspection Program (CIP) Dispatch at 1 800 813 1975 and press "7" once during the intro message. The participating contractor must also notify the customer of the need for a GSR visit. For situations where a GSR call is not required and the participating contractor is not properly licensed to make the appropriate repair, the participating contractor must arrange for a properly licensed technician to repair the hazard. Version 3.2 March 1, 2019 Line # Category Existing Conditions and/or Fail Reasons GSR Call Required? (1, 2) Pre Weatherization Evaluation (4) (Pre and Post Installation Testing for Advanced Home Upgrade) 1 General 2 Water Heater 3 Water Heater ABANDONED APPLIANCE found (Flex line removed and valve/pipe capped). Exception--open combustion in a Mobile Home. (For Example: wood burning fireplace), see Line #51 ACCESS DOORS BOTH MISSING from automatic water heater (AWH). AWH- Mobile Home AWH platform is not structurally sound (advise customer) (advise customer) 4 General COMBUSTION APPLIANCE PRESENT (includes NON PG&E sources) NOT affecting the living space. Exception- -water heater with vent safety issue, see Line #48. (contractor must be licensed to work on propane appliances) 5 COMMUNICATION AT FAF between cold air return and products of combustion that CAN be fixed by Contractor. (if repaired) 1 of 7 3/18/2019

6 COMMUNICATION AT FAF between cold air return and products of combustion that CANNOT be fixed by Contractor. 7 COMPONENTS MISSING ON FURNACE -- appliance doors, combustion chamber door(s), and/or roll out shields. (if repaired) 8 General CVA IS INADEQUATE (Include capped and AWH) and CVA Measure is FEASIBLE to install. (until CVA is installed) 9 CVA IS INADEQUATE (Include capped and AWH) and CVA Measure is NOT FEASIBLE to install. 10 General 11 Water Heater 12 Fireplace 13 General 14 General 15 General 16 17 General 18 General CVA IS INADEQUATE (Include capped AWH) and CVA Measure is NOT FEASIBLE to install on AWH not affecting living space. CVA IS INADEQUATE (Include capped AWH) and CVA Measure IS FEASIBLE to install on AWH not affecting living space. DAMPER CLIP MISSING on gas log fireplace, if primary heat source. GAS LEAK found for any appliance. Includes Fuzz Leaks (small bubbles) and Gas Leaks (gas odor and large bubbles). FUZZ LEAK that has passed GSR Inspection and was not repaired. INACCESSIBLE APPLIANCE is found. Safe access cannot be gained to test any gas appliance, or no access to any appliance in a locked cabinet or room. MICA GLASS/INSPECTION COVER on floor furnace, room heater or AWH missing or damaged. NON OP APPLIANCE found. --Pilot Light off included. --Fireplace non op included. --Oven/Broiler/Range Top appliance group must have all burners non op before any of these appliances are considered non op. NON OP ( Burners operating) APPLIANCE found. --Oven/Broiler/Range Top Appliance Group, if one burner is operative then none of these appliances are considered non op. Enter comments for each. --Gas Dryer --Appliance not affecting living space (if not repaired immediately) (if repaired) (advise customer) (if repaired) if Repaired t repairable (advise customer) (if repaired) (until repaired) (advise customer if unrepairable) (advise customer if unrepairable) 2 of 7 3/18/2019

19 NON OP APPLIANCE found. --s that are on the roof or in an attic --Same Appliance passed by GSR on previous visit for non op. (advise Customer) 20 General NON PG&E COMBUSTION APPLIANCE PRESENT that affects the living space. (Does not include portable bbq/camp stove) (contractor must be licensed to work on propane appliances) 21 NOX ROD EQUIPED FURNACES: --Listed x Rod equipped horizontal furnace (1) --Vertical s with NOX Rods not properly mounted in saddles (laying on top of burners) (1) 22 Water Heater OPEN COMBUSTION WATER HEATER and/or FAF located in sleeping area. 23 General SOLDERED FLEX CONNECTOR found. (if not replaced) (unless replaced) 24 General 25 General 26 UNCAPPED GAS LINE found and Contractor is able to cap. UNCAPPED GAS LINE found and Contractor is unable to cap. (1) UN-VENTED GAS HEATING APPLIANCE BY DESIGN (including catalytic heaters) located in living space. (Unless Capped) 27 General UN-VENTED GAS COOKING APPLIANCE BY DESIGN located in living space when used to heat home. 28 WHOLE HOUSE FAN when gas appliances with standing pilot are in the attic and attic ventalation NFVA is inadequate for whole house fan. Pre Weatherization Evaluation - Appliance Vent (4) (Pre and Post Installation Testing for Advanced Home Upgrade) 29 General CHARRING of combustibles caused by furnace and/or water heater vent. (until repaired) 30 General CHARRING of combustibles caused by appliance vent other than a furnace and/or water heater vent. (until repaired) 31 DISCONNECTED, MISSING, GAPS, DAMAGED, RUSTED- OUT OR INCORECTLY INSTALLED VENT on gas appliance that affects the living space. (t Vent Alignment). (unless NFVA is corrected or standing pilot appliance[s] replaced) (until repaired) 3 of 7 3/18/2019

32 Water Heater 33 Water Heater 34 Water Heater 35 Water Heater 36 Water Heater DRAFT DIVERTER MISALIGNED. When all components (vent, draft diverter, etc.) are in place, but have been knocked out of alignment and can be realigned easily. Includes minor work such as installing tape or screws. (Vent Alignment). DRAFT DIVERTER MISSING on natural draft appliances that affect the living space. DRAFT DIVERTERS -- MULTIPLE are present and appliance affects the living space. DRAFT DIVERTERS -- MULTIPLE are present and appliance DOES NOT affect the living space. EVAP COOLER has a water heater vent or flue termination within 10 ft and not 3 ft above on conventional home (or within 3 ft on mobile home). (until repaired) (until repaired) (until repaired) (advise customer) (until repaired) 37 EVAP COOLER has a furnace vent or flue termination within 10 ft and not 3 ft above an Evap Cooler (this includes damper on shared duct system or exterior cover) is not pre-existing, and an Evap Cooler Cover is feasible. (until repaired) 38 EVAP COOLER has a furnace vent or flue termination within 10ft and not 3 ft above an Evap Cooler, and an Evap Cooler Cover is NOT feasible or there is NO damper on a shared duct system. NOTE: If Vent not repaired, advise Customer not to run and Evap at same time. (until repaired) 39 Clothes Dryer GAS CLOTHES DRYER located within the living space: a. not exhausted to the outside b. exhausted into another appliance vent system c. exhausted into an area under the dwelling which contains an open combustion appliance or lower CVA vents. (until repaired) 40 Clothes Dryer Any Clothes Dryer exhausting into appliance enclosure or garage, but lint is not affecting open combustion appliances (occupants must be advised to watch for accumulation of dryer lint at appliance draft hood and CVA intake.) (advise Customer) 41 Clothes Dryer Gas Clothes Dryer in Mobile Home where exhaust terminated under the home (not out side of mobile home skirt). (advise Customer) 4 of 7 3/18/2019

42 Oven/ Broiler/ Range Top HEATER OR TRASH BURNER IN A RANGE that is not vented to the outside. 43 General SOLID FUEL CHIMNEY has a flue/vent connection to it. 44 IMPROPER VENT TERMINATION DISTANCE, including: a. Natural draft vertical pipe terminating less than 4 feet from outside wall and not extended above roof. b. Horizontal vent pipe outside a wall and not extended above roof. c. Direct vent wall furnace terminated within 10 feet of a window wall AC or evap cooler and not 3 feet above roof and appliance does affect the living space. (advise customer) 45 VENT OR FLUE TERMINATION DISTANCE from a door or an operable window of a Dual Pack or Pool Heater is less than 4 ft below, 4 ft horizontally or 1 ft above. (advise customer) 46 DIRECT VENT OR FLUE TERMINATION DISTANCE from a door or an operable window for a direct vent appliance is less than 9 inches for inputs up to 50,000 BTU or 12 inches for inputs greater than 50,000 up to 65,000 BTU or forced draft systems are less than 12 inches. (advise customer) 47 Water Heater WATER HEATER not affecting the living space with a vent or flue safety issue: --Charring of combustibles --Missing/damaged/rusted out -- draft diverter Pre Weatherization Evaluation - Mobile Homes (t Eligible for Advanced Home Upgrade) (advise if unable to repair) 48 Oven/ Broiler/ Range Top/ Mobiles EXHAUST FANS that are not operable, or missing, or the fan is the recirculation type instead of exhaust when gas appliances are located in the kitchen. Only Install Infiltration Measures after Exhaust fan is repaired. (1) (advise if unable to repair) 5 of 7 3/18/2019

49 Mobiles INADEQUATE ISOLATION of return air. Missing or damaged Isolation Barrier. Inadequate isolation exists when a closed combustion FAF and natural draft AWH are the same closet without a separation barrier. (until repaired) 50 Mobiles OPEN COMBUSTION FURNACES OR WATER HEATERS drawing air from the conditioned space. This applies even if capped. Post Weatherization NGAT Appliance Testing (4) (Pre and Post Installation Testing for Advanced Home Upgrade) 51 General ALDEHYDE ODOR. (1) 52 53 Oven/ Broiler/ Range Top 54 Water Heater APPLIANCE AMBIENT for furnace is 2 ppm or greater than Room Ambient. Includes Gas Log Heater (Freestanding, Insert, and Direct Vent). (1) APPLIANCE AMBIENT for Oven or Range Top or Broiler is 10 ppm or greater. Test appliance with controls at their highest setting. APPLIANCE AMBIENT for Water Heater is 10 ppm or greater., Follow, Follow, Follow Make Safe Procedure (3), Follow Make Safe Procedure (3) (until Repaired -- If already Installed, (until Repaired -- If already Installed, (until Repaired -- If already Installed, (until Repaired -- If already Installed, 55 CHAMBER CHECK found defective heat exchanger (i.e., cracks and or holes, signs of metal fatigue, excessive rust or soot, or burned out recirculation baffles)., Follow (until Repaired -- If already Installed, 56 General DELAYED IGNITION. (unless repaired) 57 General EVIDENCE OF INCOMPLETE COMBUSTION. Excessive amounts of yellow flame (more than 50%), carbon (soot), (unless repaired) or rust. (until Repaired -- If already Installed, (until Repaired -- If already Installed, 58 59 General FLAME INTERFERENCE or distortion when FAF or counter flow wall furnace fan comes on. FLAME ROLL OUT. Continuous and/or Excessive Rollout. Water Heaters and s only., Follow, Follow (until Repaired -- If already Installed, (until Repaired -- If already Installed, 6 of 7 3/18/2019

60 General FLUE READ exceeds CO Standard for Appliance Type: --FURNACE: Flue read for forced air furnace, gravity furnace, wall furnace, wall furnace direct vent, floor furnace, vented room heater, gas log heater (freestanding, insert, or direct vent), or water heater is 101 ppm or greater (air free) (1); --OVEN AND BROILER: Flue read is 226 ppm or greater (as measured) --RANGE TOP BURNERS, GRIDDLE and GAS LOG FIREPLACE: Flue read is 26 ppm or greater (as measured). Test appliance with controls at their highest setting., Follow (until Repaired -- If already Installed, 61 RADIANTS BROKEN on Room Heater. (1) (unless repaired) 62 General ROOM AMBIENT is 10 ppm or greater. (unless repaired) 63 SHORT CYCLING main burner on furnace. (1) (unless repaired) 64 General SPILLAGE at draft diverter. (unless repaired) GSR CALL PROCEDURES: (until Repaired -- If already Installed, (until Repaired -- If already Installed, (until Repaired -- If already Installed, (until Repaired -- If already Installed, (A) Inform customer about need for GSR visit and ask for their availability for a GSR visit. (B) Determine if Make Safe Procedure (MSP) applies (C) Make GSR Call from customer home. (D) Call CIP Dispatch at 1-800-813-1975 -- 8:30 am - 5:00 pm Monday through Friday except holidays. (E) After CIP dispach hours, call CIP dispatch at 1-800-813-1975, select the "7" key and wait for a PBX operator to request GSR. FOOT NOTES: (1) PG&E Fail Reason if GSR call is required (i.e., any "" to GSR Call Required). (2) GSR call required if unable to make same day repair. (3) Follow Make safe unless contractor is able to make repairs. (4) Home Upgrade Program requiring appliance testing at test-in and test-out, apply this section. (5) For Energy Saving Assistance (ESA) Program please see ESA Specific NGAT Action Guidelines. Make Safe Procedure (MSP) effective 07/1/2012 including section 24 of the installation standards (IS) please refer to NGAT MSP document. 7 of 7 3/18/2019