WATER HEATERS.

Similar documents
ELECTRIC HEATING ELEMENTS

C A T E R I N G C O M P O N E N T S

CLEAN & EXTENDED HEATING SURFACES

F4060 RESILIENT SEATED GATE VALVES

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

THE COMPANY. TECHNICAL OFFICE AND PRODUCTION UNITS. Our company has two production units:

BS 5163 EN 1074 EN 1171 ISO 7259 AS 2638 FM UL

Design and manufacture of mechanical and electro-mechanical equipment Technology in every detail

Flange immersion heaters

ACCUMULATION OF EUROPEAN CLASS

FORTUNE SMART INDUSTRIL LIMITED PRODUCT CATALOGUE

Installation, Operating and Servicing Instructions

Industrielle Elektrowärme GmbH. OhmEx. Company Presentation. Dipl.-Ing. Wolfgang Vogler (GM)

Heurtey Petrochem Manufacturing

Screw Plug Immersion Heaters

SECTION PLUMBING EQUIPMENT

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Biomass Pellet Boilers

Installation, Operating and Servicing Instructions

SB Series Brazed Plate Heat Exchanger Installation Manual

Explosion-proof Immersion Heater Type D-8660

Circulation Heaters Selection Guidelines

THE IMPORTANCE OF THE RESPONSIBLE WELDING COORDINATOR IN STRUCTURAL METALWORKS ACCORDING TO THE REQUIREMENTS OF EN CE MARKING

Gasketed and brazed plate heat exchangers

SHELL AND TUBE HEAT EXCHANGERS FOR INDUSTRIAL ONCE-THROUGH COOLING SYSTEMS AND THE OCCURRENCE OF LEAKAGE

Temperature Sensor TRG Original Installation Instructions English

HEAT TRANSFER STORAGE CALORIFIERS EC SERIES SC SERIES BT SERIES

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

SOLAR WATER HEATING SYSTEM VERSOSUN THERMAL SOLUTIONS

Annex of the Certificate (Page 1/7) Scope of Accreditation

OPERATING AND INSTALLATION MANUAL

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

BF1 GLASSLINED CYLINDERS WITH REMOVABLE STAINLESS STEEL HEAT EXCHANGER ( LITRES)

Operation and Installation Manual. Accumulation Tanks. NADO 500/200v7 NADO 750/200v7 NADO 1000/200v7

A product of tomorrow s technology.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

TRG 5-53 TRG 5-54 TRG 5-55 TRG 5-57

All our certificates could be downloaded from our web site:

Our. Heaters. for your Projects

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

with insulated heating elements for water heaters INSTALLATION AND USER MANUAL WARRANTY CARD

Nuclear Electric Heating

INSTALLATION AND OPERATION MANUAL

Seung-Jin Ind.Co.,Ltd.

EXPLOSION PROTECTION MAES SAFETY PRODUCTS & SERVICES

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

with respect to the environment PRICE LIST 2014/15

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

ISO INTERNATIONAL STANDARD. Liquid hydrogen Land vehicle fuel tanks. Hydrogène liquide Réservoirs de carburant pour véhicules terrestres

Tubular Industrial Process

Storage Tanks Type NADO

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

WATER HEATERS. Tradition from 1956

There are two devices used together for heating crude oil in petroleum refinery as in figure (1), and these devices are:

Screw plug immersion heaters

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

Condensate Recovery and Return System SDR A

Exhaust bellow APPLICATION REPORT. Application: Expansion bellow repaired. Place: Rotterdam. Date: June Job and report done by:

Custom built Tubular Heating Elements & Heating Systems for all Fluids. Since RASHMI HEATERS PVT. LTD. An ISO 9001 : 2008 Certified Company

Brilliant products. Beer fermentation and storage tanks

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Installation, Operation and Maintenance Instructions for Electric Storage Calorifier

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

OPERATING AND INSTALLATION MANUAL

Laundry Soap Production Line

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Technology, innovation and performances are the outcomes our customers want and expect us to deliver.

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Brilliant products. Fermentation and brite beer tanks

Protection and Control of Solid Fuel Boilers

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Main Steps and machines for tubular heater. Catalog

PCH Heating Condensing Module for Air Handling and Roof Top Units

Circulation Heaters Selection Guidelines

PED Workshop Nicosia, 3-5 October, 2005

JÄSPI Solid Fuel Boiler

Vapour Jet Refrigerator / Heat Pump R853

Heating Coils - Tank APPLICATION REPORT. Application: Repair of Heating Coils. Place: Lisnave, Portugal. Date: October Job and report done by:

Mounting and Operating Instructions EB 2231 EN

Product Booklet Keen KT-99 TIG Filler Wire and FCAW Wire Spool and Storage Oven 1 Drawer 7 Shelves Model

About Us steel structures, construction activity, technical industrial goods store, webshop.

SPECIALITY HOSES EXCELLENCE PRODUCT CATALOGUE

Product Booklet Keen K TIG Filler Wire and Storage Oven

( )

RECOMMENDATIONS FOR INSTALLATION

FEEDWATER TANK WITH DEAERATOR DATASHEET. Capacity 1000 to lt Operating Pressure 0,5 bar

BUSINESS PLAN CEN/TC 121 WELDING AND ALLIED PROCESSES EXECUTIVE SUMMARY

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Product Booklet Keen KT-99 TIG Wire Storage Oven 8 Shelves

INSTALLATION INSTRUCTION

Government Gazette Staatskoerant

NEW * for buildings 2-24 floors

Transcription:

WATER HEATERS www.metacomm-bih.com

WATER HEATERS Water heaters are designed for heating hot water, and can serve as energy accumulators in classical and solar systems. Heating medium - hot water or steam transfer their heat through the tubular heating element which is made of copper or stainless steel pipes. In the absence heating medium heat can be exported electricity to the electric heater. The size of this heater is selected according to need, and its operation is controlled through the thermostat with thermal fuse. Heaters have demounting design which allows open containers and cleaning and repairing them. Water heaters are made as follow: 1. Water heaters with a tubular heater BC 2. Water heaters with electric heater BE 3. Water heaters with a combination of pipe and electric heaters BK Water heaters have horizontal or vertical design with the necessary connections that can be thread nipple or flange. It is made of a suitable steel intended for the production of pressure vessels. Water heaters are designed for the standard to work with the pressure of 6 bar and temperatures up to 65 C and by clients need they can be made for multiple applications. They have outside protected by a double-coated layers, while the inner side of such protection is on client's request. It is made in accordance with technical standards for stable pressure vessels and standards BAS.M.E2. During delivery, each boiler belonging to the factory default certificate with the designated number, date production and test pressure. Basic data size vessels and heaters are in the table below. When orders client must specify: 1. Type and performance of the water heater 2. Volume and heating surface 3. Primary and secondary fluid parameters (temperature and pressure) 4. On requests for installation of electric heaters, heating power electric heaters 5. The water heaters that are not covered by table, additional drafts and connections list are required

VERTICAL WATER HEATERS Volume D H A B Connections lit. - - - - a b c d e f 800 800 1950 1165 1355 1 1/2 1 1 1/2 1 2 2 1000 900 1950 1265 1455 2 1 1/4 2 1 2 2 1250 1000 2000 1365 1555 2 1 1/4 2 1 1/2 2 2 1500 1000 2330 1365 1555 2 1 1/4 2 1 1/2 2 2 2000 1100 2550 1465 1655 2 1 1/4 2 1 1/2 2 2 2500 1200 2650 1565 1755 2 1/2 1 1/2 2 1/2 1 1/2 2 2 3000 1300 2750 1665 1855 2 1/2 1 1/2 2 1/2 2 2 1/2 2 1/2 4000 1400 3100 1765 1955 3 2 3 2 2 1/2 2 1/2 5000 1500 3250 1865 2266 3 2 3 2 2 2 6000 1600 3550 1865 2180 3 2 3 2 2 1/2 2 1/2 8000 1700 4100 2065 2280 3 2 3 2 3 3 10000 1800 4550 2280 2380 3 2 3 2 3 3 Heating pipe surface (m2) 3; 5; 9; 12; 2 2,5 3 4 5 6 8 10,2 12 16 20 Power of electical heater (kw) 15; 18, 21; 27; 30; 36; 42; 51; 54; 57; 60; 63; 66; 69; 72; 75.

HORIZONTAL WATER HEATERS Volume D H A L Connections lit. mm - mm mm a b c d! f 400 550 750 1800 2160 1 1/2 1 1/2 1 1/2 1 1/2 1 1 1/2 500 600 800 1900 2260 1 1/2 1 1/2 1 1/2 1 1/2 1 1 1/2 600 600 800 2280 2645 1 1/2 1 1/2 1 1/2 1 1/2 1 1 1/2 800 700 900 2520 2865 2 2 1 1/2 1 1/2 1 1 1/2 1000 750 950 2610 2975 2 2 2 2 1 1/4 2 1250 800 1000 2810 3175 2 2 2 2 1 1/4 2 1500 900 1100 2805 3170 2 2 2 2 1 1/4 2 2000 1000 1100 3000 3365 2 2 2 2 1 1/2 2 2500 1000 1100 3510 3785 2 2 2 1/2 2 1/2 1 1/2 2 3000 1000 1100 4160 4525 2 1/2 2 1/2 2 1/2 2 1/2 1 1/2 2 1/2 4000 1100 1300 4570 4935 2 1/2 2 1/2 2 1/2 3 2 3 5000 1200 1400 4915 5280 2 2 2 3 2 3 Heating pipe surface (m2) 3; 5; 9; 12; 2 2,5 3 4 5 6 8 10,2 Power of electical heater (kw) 15; 18, 21; 27; 30; 36; 42; 51; 54; 57; 60; 63; 66; 69; 72; 75.

Metacomm is 100% privately own company for production of welded structures and vessels made of carbon steel, stainless steel and aluminum alloys. Metacomm was founded in 2005. in order to continue 40 years long experience in production and to maintain market position in the energy sector of Energoinvest, Sarajevo (most famous factory in ex-yugoslavia). Metacomm did acquire all resources (personnel, equipment, facilities and documentation) from Energoinvest s Factory for Process Equipment in Jajce. The company owns the area of 30.000 m2, 2400 m2 of production facilities, warehouses and workshops, and mechanical equipment (equipment for cutting, grooving phases of welding, circular and angular bending, positioners and turners for container assembling, milling machines, drilling machines, lathes for the production of flanges and filter plate, hydro-test up to 40 bar, annealing and ACP for production of cylindrical, welded vessels and equipment under pressure from class 1 to class 4 according to EU Directive: PED 97/23/EC. There is possibility of heat-treatment of products (annealing), and anti-corrosion protection (sand blasting, coating, rubber lining etc.).. We are the only company in Bosnia and Herzegovina which produces dish heads through process of incremental deformation in cold condition for cylindrical vessels in the area of a diameter of 800 mm to 4000 mm thickness up to 14 mm for steel of limit of elasticity up to 355 MPa. We have introduced a system of quality management ISO 9001 and facility certified welders for the execution of welding processes according to EN 3834 (by the TÜV / Munich). The company employs about 60 workers trained and tested for the production of vessels and pressurized equipment (engineers in the field of engineering calculations and welded construction with certificate from EWE( European welding Engineers) and IWE (International Welding Engineers), certified welders for welding processes: MIG / MAG, TIG / WIG, UP-EPP, REL). The average processing capacity in the last three years has been approx. 1,500 MT hot rolled steel sheets in the quality of S235JRG to S355J2G3 in vessels/tanks for water, oil and petroleum products, refinery gases, air and other technical gases. We have process about 150 MT/year of stainless steel and aluminum alloys (AlMg) in equipment for the food industry. The company has established cooperation with certified subcontractors for the services of testing (NDT, UT, RT and methods with destruction of material FMT), and services of hard rubber lining of equipment for aggressive fluids. Company vision is to become concurrent regarding quality of produced goods, finale treatment, documentations, delivery time and expertise of key personnel to the manufacturers from countries with traditional in industrial production of pressurized process equipment. METACOMM Ltd. Manufacture of welded steel constructions and vessels Bage 5, 70101 Jajce Bosnia and Herzegovina Centrale : +387 30 658-041 Tel: +387 30 659-796 Fax: +387 30 658-283 e-mail: metacomm.jajce@gmail.com www: www.metacomm-bih.com Registration and Custom No. : 4236335580000 VAT No. : 236335580000 Account No. : 3389002210707028 UniCredit Banka d.d. SWIFT: UNCRBA22; IBAN: BA 393389002210707028 ISO 9001:2000 EN ISO 3834-3 INTERNATIONAL INSTITUTE OF WELDING EUROPEAN WELDING FEDERATION