Multifunction IAQ Monitor

Similar documents
The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

High-accuracy Multi-sensor IAQ Detector MSD Commercial grade for intelligent& green buildings

Air-Quality Detection Module. User s Manual

User's Guide. CO 2 Monitor. Model CO200

Real-time Monitoring Technology for Preservation Environment of Archives

Air-Quality Detection Module. User s Manual

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

D6.27 Results obtained through the integration of sensors in regulation systems (Final version due M36)

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

EasyLog Data Logger Series

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

ALTAIR 5X Multigas Detector Product Specification

VALTRONICS IAQ Monitor

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

EasyLog Data Logger Series

portable gas analyser

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Accuracy by Design Products for the HVAC Professional

SP-220. Features. Combustible handheld gas leakage detector

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Toxic Gas Detection. Model F12. Toxic Gas Detection

Sirius Technologies, Inc.

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

portable gas analyser

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Room air quality sensors

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

CO2 Carbon Dioxide Sensor

Multi-sensor System For Indoor Environment Monitoring Zheng-yu Wanga, and Xiao-ru Zhangb

WRF04 CO 2 RS485 Modbus

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

GasAlertMicroClip X3 Specifications

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Hygrometer / Air Quality Meter

ALTAIR 5X Multigas Detector

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Model D12-IR. Digital Gas Transmitter...

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

MicroRay IR-100 NEW. Inspection MicroRay IR-100

E1000 Portable gas detector

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Infrared Moisture Balance (FD-660)

Installation and Wiring 1.

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Dräger X-am 7000 Multi-Gas Detection

Monitores Personales. Personal Monitor

Exceptional data integrity. Complete peace of mind.

AirTest Technologies Inc.

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Murco Core Product Guide Gas Leak Detection Solutions for all your building needs

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Product Catalogue. Air and Gas Sensors. Save Life and Energy

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Measurement Solutions for Refrigeration Technology.

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Datasheet. CozIR -A CO2 Sensor. Tel: +44 (0)

Waspmote Plug & Sense! Quick Overview

Polytector III G999 for Ex zone 0

CMT MANUAL 6. NMC SENSORS

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

OLC(T) 100 FIXED GAS DETECTOR

Carbon Monoxide Transmitter

RAE Systems Systems. User Presentation. October Protection Through Detection

onlinecomponents.com

KANE-ALERT-CO 2 Monitor with Temperature

Tinytag Ultra Data Logger Manual

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

Two-Channel Gas Controller

APPLICATION DATA SHEET

ALTAIR 5X Multigas Detector

GAS PLUS ALARM SYSTEM

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

IMR EX610. Portable Gas Detector. Operation Manual

ExplorIR -W CO2 Sensor

ExplorIR -M CO2 Sensor

Duct Air Quality Sensors

SAMPLE SPECIFICATIONS CONTINUOUS MONITORING SYSTEM (Insitu)

Measurement Solutions for Refrigeration Technology.

Ventostat Wall Mount. Amphenol. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Advanced Sensors. Features:

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

Infrared Moisture Balance (FD-800)

Datasheet: K-22 LO Sensor

Transcription:

Multifunction IAQ Monitor Better Sensing, Better Life Introduction The standard monitor has below two models Carbon dioxide(co 2)+CO 2 average +Temperature+ Humidity (Model:DPM-1003) Carbon dioxide(co 2)+CO 2 average +VOC +Temperature+ Humidity (Model:DPM-1004) Two unique extended functions (Optional) RF short-distance wireless transmission & reception USB data logging The product can be worked together with our wireless controller to control a ventilator, air cleaning device, or humidity device, based on the real-time measurements and the presetting values of the monitor. Application In all the areas where real time monitoring of indoor air quality such as residence, offices, kindergartens, classrooms in schools, hospitals, shopping malls, restaurants, cinemas and other open areas. Indicating and alarm for poor ventilation. Sound alarm for high concentration to avoid poisoning Used to control a ventilator, air cleaner or humidifier/dehumidifier Decrease air pollution and cross-infection for relative closed rooms. With the optional RF short distance wireless module inside, it can be connected to the telecom operating platforms, or other systems. Also realize the remote control With the wireless coordinator together, the IAQ monitors can be connected with a PC USB data logging, record measurement data. LCD and display With large 7 LCD and 16:9 display, it can be hung easily on the wall or placed on the desk. With the special self-adaptive brightness design, the LCD can be adjusted its brightness itself based on the light of indoor. Three-color backlit of the LCD displays the clear and intuitionistic measurements of CO 2, VOC, and temperature, relative humidity. The three-color backlit LCD indicates and alarm different air quality levels: GREEN-for optimal air quality, YELLOW-for moderate air quality, RED-for poor air quality self-adjusted brightness LCD, selectable 3-color backlit switch mode

Detection and Displays: DPM1003: Carbon dioxide (CO 2), CO 2 average level (in setting time range: 1~24hous), Temperature, Humidity, Clock and Time. DPM1004: Carbon dioxide (CO 2), CO 2 average level (in setting time range: 1~24hous), VOC, Temperature, Humidity, Clock and Time. Wall-mounted or put on the desk. LCD display Model: DPM1003 LCD display Model: DPM1004 Monitoring Focus Carbon Dioxide (CO 2) Indoor CO 2 level is a universal accepted parameter for the condition of indoor ventilation and air quality.

A time period can be preset from 1 to 24 hours, e.g. 5 hours, then the monitor can display CO 2 average level during this period, which provides an objective and true data for the measurement of the air quality in a certain space. Non-dispersive infrared (NDIR) CO 2 sensor with more than 10-year lifetime ABC self-calibration technology guarantees reliable CO 2 measurement CO 2 range: 0~2000ppm/0~5000ppm optional Rapid response, high stability and consistency Mix Gases (VOC-Volatile organic compound) VOC emitted from building materials, decoration materials and furniture, includes toluene, ammonia, H2S, formaldehyde and other harmful gases. Its necessary to real time detect these harmful gases. But it s costly to use the professional instruments to detect each single gas. Also it s possible to monitor for daily use. These gases exit in air for a long time and their volatilization level are different in different temperature and humidity, the reliability of such detection by a professional instrument for a single gas is very limited. This multifunction IAQ monitor uses a mix gas sensor. It has high sensitive to kinds of volatile pollutant gases (VOC) such as ammonia, toluene, formaldehyde and cigarette smoke, alcohol, H2S, and carbon monoxide. So it is very suitable to monitor the general indoor air quality in real time and long term. The mix gases sensor responds quickly to any change of the concentration of such gases. Not only you may open windows for fresh air coming but also the monitor can control a ventilator/air-cleaning devise based on the indication and alarm. Built in the semi-conductor mix gases sensor 5~7 years life time High sensitive to volatile gases like ammonia, toluene, formaldehyde, sensitive to cigarette smoke, alcohol, H2S, etc. Small volume, lower consumption Temperature and humidity Switzerland digital temperature/humidity sensor built in with high accuracy and stability. It also has compensation to CO 2 and VOC which makes the measurements more accurate by minimizing environmental effects. Optional functions Short-distance wireless: built-in the optional short distance wireless module which can receive or transmit measurements, connect to a devise for remote control such as a ventilator, dehumidifier/humidifier, air-cleaning and etc. Also more than 120 units IAQ monitors to be connected to a PC via a wireless router. Data logging: provide the USB data-logger with internal data-logging module, record real-time measurements, preset the sampling interval time, and can record maximum 60 days data if sampling interval time is 1 minute. Using the special software with the USB data logger, the record parameters can be preset and the data in the monitor can be copied to a USB disk and displayed in PC.

Specifications Monitoring parameters Relative CO 2 VOC Temperature humidity Non-Dispersive Infrared Semiconductor mix Digital combined temperature Sensing element Detector (NDIR) gases sensor and humidity sensor 0~99%R Measuring range 0~5000ppm 0~30ppm -20~60 H Display Resolution 1ppm 5ppm 0.1 0.1%RH Accuracy@25 (77 ) ±50ppm + 3% of reading ±10% ±0.5 ±3%RH Life time 15 years (normal) 5~7 years 10 years Stability <2% Calibration cycle Response Time Warm up time ABC Logic Self Calibration ( No client separate calibration) <2 minutes for 90% change 2 hours (first time) 2 minutes (operation) <0.04 per year <0.5%RH per year <1 minute (for 10ppm hydrogen, 30ppm ethanol) <5 minute (for a cigarette) in 20m 2 room Electrical Characteristics <10 seconds to reach 63% Power supply Consumption Screen 3-color backlit LCD 5VDC, Power adapter connected directly to 100VAC~220VAC. 3.5W max; 2.5 W average Display and Alarm 7-inch 16:9 LCD display: 152mmX84.5mm For other customized size LCD screen, please contact us directly. self-adjusted brightness and selectable 3-color backlit switch mode Green: CO 2<1000ppm (optimal air quality) VOC<10ppm (low pollution) Yellow: CO 2>1000ppm (moderate air quality) VOC>10ppm (medium pollution) Red: CO 2>1400ppm (poor air quality) VOC>20ppm (heavy pollution) Backlight brightness Real-time display Operation conditions Two switch modes selectable: both CO2 and VOC over the setpoints(default) any one over the setpoint Automatically adjust the brightness according to the environment Year, month, day, week, clock Storage conditions -40~70 (-40~158 ) Weight Conditions of Using and Installation -10~50 (14~122 ); 0~95%RH, non condensing 450g Temperature, RH, CO 2 CO 2 average level, VOC

Dimensions Installation Housing IP class USB data logging (optional) Short-distance wireless (optional) 230mm(W) 160mm(H) 35mm(D) Desktop or Hanging PC/ABS, protection class: IP30. Optional Functions USB2.0 host mode: support the regular collection, sampling cycle selectable. Preset selected sampling measurements. Support U disk offline or online record. Built-in 16MBit data memory ZigBee (2.4G IEEE 802.15.4) protocol available, as well as another appointed protocol. Automatic buildup network, 16 channels, automatically select a reliable channel based on the environment. The reliable transmission is up to 1000 meters in the visible range. Correlative wireless controller This wireless controller has internal wireless transmission/access two-way module, with the IAQ monitor together; it can control a ventilator, temperature & humidity device, air-cleaning device, etc. Easy installation and wiring. The specifications of the controller is as below Power supply 220VAC Consumption 1.5W Wireless Output Operation condition ZigBee(2.4G IEEE 802.15.4) application protocol, and another asked protocol available. Automatic buildup network, 16 channels, and auto selection a reliable channel based on the environment. Reliable transmission up to 1000 meters in the visible range one dry contact output in max. 12A load -10~50 (14~122 ); 0~95%RH, no condensing Storage condition -40~70 (-40~158 ) Weight Dimensions Installation Housing IP class 210g 85mm(L)X100mm(W)X51mm(D) Excluding the antenna, wires, waterproof connectors Wall mounting. Mounting hole width: 120mm PC/ABS fireproof plastic material, protection class: IP60 Models Guide Model Description

Multi-function IAQ Monitor ( with USB Data Logging) Wireless Multi-function IAQ monitor Wireless Coordinator Wireless Controller DPM1183 DPM1184 DPM1103 DPM1104 HAC-L TCW111A TCW111C Detect and Monitoring indoor Temp.+RH+CO2+CO2 average. USB data logger. Zigbee wireless communication for CO2 control. Detect and Monitoring indoor Temp.+RH+CO2++CO2 average as well as VOC. USB data logger. Zigbee wireless communication for CO2 control. Detect indoor Temp.+RH+CO 2+CO 2 Average with Zigbee wireless communication Detect indoor Temp.+RH+CO 2+CO 2 Average + VOC with Zigbee wireless communication ZigBee wireless coordinator, can be used with DPM-11 to connect with a PC. Reliable transmission is up to 1000 meters in the visible range Work with the IAQ monitor together with ZigBee wireless. 1Xdry contact output to control a max. 12A load. ( ventilator, air cleaning equipment, etc) Power supply: 230VAC Work with the IAQ monitor together with ZigBee wireless. 1Xdry contact output to control a max. 12A load. ( ventilator, air cleaning equipment, etc) Power supply: 24VAC/VDC Figures of applications Connection with a PC Wireless controller Control a device