Adult and paediatric ventilators. Quick Setup Guide. English

Similar documents
Quick setup guide. English

VPAP ST with ivaps. Welcome Guide. Making quality of care easy. English. Respiratory Care Solutions NONINVASIVE VENTILATOR

Disconnection Alarm Guide. English

Quick start guide. English

AutoSet CS POSITIVE AIRWAY PRESSURE DEVICE. Welcome Guide. English

VPAP Adapt. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

Non-invasive/invasive ventilators. User Guide. English

heated humidifier H5i Welcome Guide English

VPAP COPD. H5i. Welcome Guide. Making quality of care easy. Respiratory Care Solutions. English NONINVASIVE VENTILATOR HEATED HUMIDIFIER

User guide User guide English

VPAP Auto VPAP ST VPAP S. H5i. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE HEATED HUMIDIFIER

S9 Escape. Welcome Guide. English POSITIVE AIRWAY PRESSURE DEVICE

VPAP Adapt. H5i. Welcome Guide. English. adaptive servo-ventilator

S9 AutoSet & S9 Elite

H5i disinfection guide

AutoSet & Elite. Welcome Guide / S9 Series. AutoSet & Elite WELCOME EUR2 / APAC. English Svenska Norsk Suomi Dansk Eesti 简体中文 繁體中文

User guide User guide English

User guide User guide English

AutoSet AutoSet for Her Elite Escape Auto Escape. H5i H5i for Her. Welcome Guide. English. POSITIVE AIRWAY PRESSURE DEVICEs HEATED HUMIDIFIER

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

VICTORIAN RESPIRATORY SUPPORT SERVICE AUSTIN HEALTH

English Please read the entire Information and Welcome Guides before using your device.

NIPPY junior+ Quick Reference Guide

Cl inician Training Packet

CLINICAL MANUAL REF JH 6/7/10 CLINICAL MANUAL

User guide User guide English

User guide User guide English

H4i. User Guide HEATED HUMIDIFIER. English

User guide User guide English

INSTRUCTION MANUAL FOR THE NIPPY 3+ POSITIVE PRESSURE VENTILATOR This book must be kept with the machine

S9 Series AutoSet & Elite

DreamStation Service & Technical Reference Manual

Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

VPAP ST VPAP S AutoSet CS S9 Auto 25

Quick start guide. BiPAP AVAPS

User guide. User guide. English

User guide User guide English

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

USER Manual JR 10/02/06

H4i HEATED HUMIDIFIER

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Quick start guide. BiPAP AVAPS

INSTRUCTION MANUAL FOR THE NIPPY 3+ POSITIVE PRESSURE VENTILATOR This book must be kept with the machine

Clinical Use Only. ResMed HumidAire 2i. Disinfection and Sterilisation Guide. English

INSTRUCTION MANUAL FOR THE NIPPY JUNIOR PAEDIATRIC VENTILATOR

Oxylog VE300 Emergency & Transport Ventilation

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

Operating Manual. Model HC254

Oxylog VE300 Emergency & Transport Ventilation

DreamStation. BiPAP autosv REF R04 HM 01/30/2017 EN-DOM. User manual

DreamStation. BiPAP Pro. Auto BiPAP. User manual

Puritan Bennett 980 Ventilator System Planning for Training Checklist

VPAP III ST-A with QuickNav

Oxylog VE300 Emergency & Transport Ventilation

A U T O S E R I E S Operating Manual

User guide User guide English

BiPAP Pro Bi-Flex USER MANUAL

System Contents Your REMstar Pro C-Flex+ system includes the following items: Reusable gray foam filter Disposable ultra-fine filter (optional)

User guide User guide English r2 cover.indd 2 8/04/2016 4:17:25 PM

CARAT II. User's Manual Ventilator. as of device software Quality makes the Difference

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

User guide User guide English

product overview Adult Care Solutions

PRODUCT OVERVIEW. Adult Care Solutions

User guide User guide English

Clinical guide. English

Clinical guide. English

MODEL 3X Series User s Manual

PULSE OXIMETER PACKAGE

REMstar Auto A-Flex USER MANUAL

Oxylog 2000 plus Pocket Guide Software version 1.n

User guide User guide English

User guide User guide English

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

INSTRUCTION MANUAL FOR THE NIPPY 2 POSITIVE PRESSURE VENTILATOR

ACCESSORIES ISLEEP VIVO Z1

RESmart BPAP System. Service Manual

O-Two Self-Study Guide. eseries Transport Ventilator Control and Function Keys and Connections

SmarTemp Control fx 2.0

Guide, Quick Start, Short, X-100 System

Syringe Pump. User Manual

REMstar Auto A-Flex USER MANUAL

CPAPSolutions. Product Profile. Overview: The Family of SleepStyle TM CPAP Solutions

SPECIFICATION FOR MULTIPARAMETER MONITOR

Model 900. Pulse Oximeter User s Manual

Quick start guide. CPAP Pro. Auto CPAP. Navigating in the menu. Caring for my. Setting up my therapy. DreamStation. Additional help and tips

Service Manual for RESmart CPAP V1.0. RESmart TM CPAP System. Service Manual

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

LEONI baby ventilator service manual

Quick Reference Guide *

HAMILTON-H900. Intelligent humidification for all patient groups

Table of Contents. isleep 20 users manual

SERVICE MANUAL. NPB-295 Pulse Oximeter

Carina Guidelines. The Carina Guidelines are not a replacement or substitute for the Instructions for Use.

QAM.L L550 series. Patient Monitor Manual QAM.L

PRODUCT SPECIFICATIONS VENTILATOR Aeros-4600

Follett Performance Plus

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Make the Connection. Compatibility Guide for Noninvasive Systems Validated With INOmax DS IR Plus

Transcription:

Adult and paediatric ventilators Quick Setup Guide English

Setup Noninvasive use AC Power cord Mask Stellar 2 Air tubing 3 4 5 1 AC Power cord AC locking clip H4i heated humidifier Invasive use 2 Antibacterial filter 2 ResMed Leak Valve HMEF* Catheter mount** 1 1 3 5 5 3 7 6 4 4 6 AC Power cord AC locking clip External humidifier* Air tubing *If not using an external humidifier, connect the HMEF to the ResMed Leak Valve. ** The ResMed Leak Valve or the HMEF can be connected to standardized tracheostomy interfaces including connector pieces like catheter mounts. The catheter mount and the external humidifier are not part of the ResMed component. 2

About the control panel External power supply LED On when external battery is connected. Internal battery LED On when internal battery is in use. Flashes when device is turned off and battery is charging. Alarm LED Red or yellow during an alarm condition or during alarm testing. Alarm mute button LED On when is pressed. Alarm mute button Silence the alarm Clear the alarm message (low priority alarms). Mains power LED On when operating on mains power. LCD screen Menu button Navigate through the menus Monitoring Setup Info Push dial (rotate/click) Navigate through settings. Change settings values. Enter and confirm your selection. Therapy LED On during treatment Flashes during mask fitting operation. Start/Stop button Start/ Stop ventilation Start mask-fit (hold down for at least three seconds). Rear panel Oxygen inlet Air filter cover ON/STAND-BY XPOD pulse oximeter connection FiO 2 sensor connection Data port for USB stick Remote alarm connection DC power socket AC power socket Power on/stand-by switch Data port for direct PC connection 3

Turning the ventilator on/off To turn the ventilator on, press the power switch at the rear of the device. Wait until the Treatment screen is displayed. To turn the ventilator off, press the power switch at the rear of the device. Follow the onscreen instructions. Accessing Clinical mode Press and simultaneously for three seconds until the duration options appear. Follow the onscreen instructions. To return to the Patient menu, press and simultaneously for at least three seconds. Treatment settings Program Ramp time Warm-up humidifier Yellow arrows display at the top or bottom of the pressure bar graph will show if a machine trigger or cycle occured. If the inspiratory phase extends beyond the spontaneous cycle by Ti Min, a red arrow is displayed. Selecting the mask type and performing a Learn circuit enables to calculate the impedance and leak for controlled therapy pressure. Learn Circuit configuration Do not connect patient interfaces prior to performing the Learn Circuit. Patient interfaces include any components placed after the ResMed Leak Valve (eg, HMEF, catheter mount, tracheostomy tube). With an external humidifier Without an external humidifier Antibacterial filter ResMed Leak Valve Antibacterial filter ResMed Leak Valve Air tubing Air tubing External Humidifier 4

Using the menus Menu overview MONITORING SETUP INFO Treatment Clinical Settings Event Summary Monitoring Leak Pressure / Flow Alarm Settings Minute Ventilation MV/Resp Rate or MV/Va (ivaps Mode) Tidal Volume Leak Options Respiratory Rate Tidal Volume I:E Ratio Synchronisation Pressure Support Oximetry AHI SpO2 Used Hours Device Information Reminder Note: ivaps mode is only available in Stellar 150. 5

Overview Clinical Settings SETUP Clinical Settings Advanced Settings CPAP Mode S Mode ST Mode T Mode ivaps Mode PAC Mode Note: ivaps mode is only available in Stellar 150. 6

Overview Alarm Settings and Options SETUP Alarm Settings Options Configuration Menu 7

Pathology defaults Setting Mode Obstructive lung disease S ST T PAC ivaps Restrictive lung disease Obesity Hypoventilation Syndrome Normal lung mechanics IPAP [cm H2O] 13 11 16 11 EPAP or PEEP [cm H2O] 5 5 8 5 PS [cm H2O] 8 6 8 6 Rise time [ms]* 150 300 300 200 Fall time [ms]* 200 200 200 200 Trigger sensitivity Medium Medium Medium Medium Cycle sensitivity High Low Medium Medium Min PS [cm H2O] 4 4 4 2 Max PS [cm H2O] 20 20 18 20 Min EPAP [cm H2O] 5 5 8 5 Max EPAP [cm H2O] 15 15 15 15 Ti Min [sec] 0.3 0.5 0.5 0.5 Ti Max [sec] 1.0 1.5 1.5 1.5 *The Rise/Fall Time milliseconds scale is an approximate only. Note: ivaps mode is only available in Stellar 150. See the Stellar Clinical Guide for full details. Not all devices are available in all regions. MANUFACTURER ResMed Germany Inc. Fraunhoferstr. 16 82152 Martinsried Germany DISTRIBUTED BY ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp 9001 Spectrum Center Blvd San Diego CA 92123 USA ResMed (UK) Ltd 96 Jubilee Ave Milton Park Abingdon Oxfordshire OX14 4RW UK See www.resmed.com for other ResMed locations worldwide. For patent information, see www.resmed.com/ip. ResMed and Stellar are trademarks of ResMed Ltd. ResMed and Stellar are registered in U.S. Patent and Trademark Office. 2015 ResMed Ltd. 248800/1 2015-05 ResMed.com