THERMOFOCUS 0800H5 Professional

Similar documents
THERMOFOCUS 01500A3 THERMOFOCUS

Forehead Thermometer Instruction Manual

Forehead Infrared Thermometer

Insta-ThermTM. All-in-One Thermometer. Instructions. Ear Forehead Ambient Room Temperature

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

Instructions. Consumer Info-Line

Dual-Mode Infrared Thermometer Instruction Manual

CLETEF-786. Infrared Thermometer Instruction Manual

Kinsa Smart Ear ThermometerTM Instructions For Use

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

GHC Thermee Non-Contact Forehead Thermometer Instruction manual V2.5

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

User Manual. Non-contact Infrared Thermometer.

By cmlam at 2:33 pm, Dec 12, 2017

Forehead Thermometer Instruction manual

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

Precision Infrared Thermometer. Users Manual

SensorTouch TEMPLE THERMOMETER FAST & EASY GUARANTEED ACCURACY HF370/HF375. Gentle stroke of forehead measures temperature

IRT2 Dual Laser IR Thermometer - User Guide

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

No Touch Thermometer

I/R Thermometer Gun 12:1

Dual Laser InfraRed (IR) Thermometer

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

Manual PCE-889 pyrometer

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Dual Laser InfraRed (IR) Thermometer

KNOW YOUR ELEKTRA HEALTH THERMOMETER. ON / OFF Button

Point Detector PS 3 Instructions for use

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

R2310. Infrared Thermometer. Instruction Manual

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

SAD Day Light. Product Code: DL Unit Description

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

NON-TOUCH THERMOMETER User Manual

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

Commodity Description

SAD Light Pad. Product Code: DL Unit Description

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Precision Infrared Thermometer. Users Manual

KANE-ALERT-CO 2 Monitor with Temperature

GETINGE WD14 TABLO A GOOD-LOOKING TABLETOP WASHER-DISINFECTOR. Always with you

Solutions for Temperature Regulation Problems by Susan Agrawal

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

CareTemp Touch Free Thermometer. Directions for use

Black Body Calibration Source User Manual

Instruction manual EN

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

Human-Oriented Medical Laser Company. ELESYS Company introduction

EVac II Programmable Digital Vacuum Gauge

5. Instrument and accessories discharging must be done following current law regulations in every country of use.

Adtemp TM 427 TempleTouch TM Thermometer USE, CARE & MAINTENANCE

Soil Moisture Probe. Frizzell ltd. Owners Manual And Reference. Model SMP3A. frizzell ltd. Box 32 Kirwee Canterbury, 7543 New Zealand Ph:

SF 6 -Leak Pointer Operating Manual (original version) Type-No.: R002

62 MAX/62 MAX + Infrared Thermometer. Users Manual

A3G Green Rotary Laser SPECIAL EDITION INSTRUCTION MANUAL

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET FEATURES

64 Max IR Thermometer

BIO-SPECTRUM TREATMENT DEVICE

Vernay-QM Series Disposable Pumps

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

for a healthy world Product catalogue 2010/ 2011

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

The Professional Choice

MD-MINI Dry Bath. Instruction Manual

ATMOS Bronchial Suction

REFRIGERANT LEAK DETECTOR

HV2R ROTARY LASER INSTRUCTION MANUAL

RS Pro Infrared Temperature Sensor

Wide Temperature Range Low Cost Max Temperature Display Tripod Mountable Applications

ML1 MULTI-LINE LASER INSTRUCTION MANUAL

Danfoss ECO. The easy way to Smart Heating

PD240 NEW GENERATION WIDE SEARCH AREA HAND HELD METAL DETECTION SET

CLEO VERSATILITY IN VITAL SIGNS

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

The Professional Choice

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Instruction FH-CWP Thermostat

MT4 MAX/MT4 MAX + Infrared Thermometer

Table of Contents. English

ALTAIR 5X Multigas Detector Product Specification

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

Oxygen measuring device Operating manual

TopLine Active protection of patients and nursing staff

100 Ft. LASER DISTANCE METER

H1R Red Rotary Laser INSTRUCTION MANUAL

A measured step forward

ATMOS Surgical Suction

Components of the device. Appearance of the device. ihealth thermometer User s manual LED screen. Manufacturer info. LED screen.

LD-5000 REFRIGERANT LEAK DETECTOR

CL3 HYBRID MULTI-LINE LASER INSTRUCTION MANUAL

64 Max IR Thermometer

OMNI Express VS VERSATILITY IN VITAL SIGNS

740 SELECT. Multi-Parameter Monitor

TruStability Board Mount Pressure Sensors

Transcription:

THERMOFOCUS 0800H5 Professional Name : Description : Manufacturer : Project : Owner Patents : Thermofocus 0800H5 Infrared non-contact clinical thermometer which allows an instant, hygienic and extremely accurate measurement of body temperature without any contact with the subject / patient Tecnimed srl, plant in Vedano Olona, Varese Tecnimed srl, Vedano O. (VA) Italy Tecnimed srl, Vedano O. (VA) Italy CE classification : Class IIa Medical Device CE 0051 Other certifications : Patents : Conformance : FDA (USA), TGA (Australia), Koseisho (Japan), KFDA (Korea), CFDA (China), etc. MI 1.284.119, EP 0909.377, US 6.196.714, IL 127.876, JP 504.769/98, EP 1.283.983, US 7.001.066, JP 3.863.919, and other International Patents Pending CE approved according to 93/42/EEC Directive and s.m.i, Quality System ISO 9001:2015, ISO 13485:2016 EN 60601-1, EN 60601-1-2, EN 60601-1-6, EN 60601-1-11 UNI CEI EN ISO 14971:2012 ASTM (American Society for testing Materials) E 1965-98(2009) Accordance with RoHS (Pb-free) directive 1

Thermofocus 0800H5 is the first infrared non-contact thermometer specifically studied for professional use (i.e. in hospitals and sanitary facilities), having an exclusive aiming system in order to provide doctors and healthcare professionals a precise, hygienic and easy-to-use tool to measure body temperature in any kind of condition. HOW IT WORKS Thermofocus reads infrared radiations naturally emitted by the surface of the skin and calculates the whole body temperature. It can also be used for measuring the temperature of both solid and liquid objects. Body temperature is measured by pointing Thermofocus at the middle of the forehead. Simply hold the thermometer close to the middle of the forehead and press the face button: the correct distance between the skin and the thermometer is easily determined thanks to the aiming system emitting two amber-colored LED lights. As the thermometer is moved closer to the skin, when the two lights converge into a single spot you are at the right distance (approx. cm 3 / 1.2 inch). At that point, release the face button and keep the thermometer still until the lights flash: the temperature appears in the LCD display. In case the subject has a perspiring forehead or is crying (i.e. a child) or for elderly people especially with wrinkled forehead (a low supplying of blood may cause a low temperature) - or with oxygen mask, the measurement must be taken on alternative areas such as preferably on the middle of the closed eyelid. If the measurement on the closed eyelid is not feasible (i.e. due to inflammation, surgery or other) the third recommended area to measure the body temperature is on the neck in correspondence with the jugular vein. ADVANTAGES The use of Thermofocus 0800H5 ensures a series of great and concrete advantages for both the user - doctor, nurse, etc. - and the patient: - while other kinds of thermometers require disinfection after each use or need expensive hygienic and disposable covers, Thermofocus does not need these actions at all. The noncontact measuring system totally eliminates all disinfection procedures and caps substitution charges, with a saving that for a hospital results very high in terms of both time and money. Let s try to calculate how much it is: usually the cost of a probe cover for ear thermometer is between 4 and 10 euro cents (depending on the type of device). Let s assume an average cost of 5 eurocents each and to make 2 measurements per day in a ward with 50 beds. The cost will be 0,05 x 2 x 50 = 5 Euros per day spent in disposable covers. After 1 year (365 days) the total annual cost will be 1.825 Euros for each thermometer. A complete waste of money! - with other thermometers, for each measurement you should calculate: putting the cover on the probe, positioning the device in the ear canal, taking away and disposing the cover, which takes about 15 seconds in total. So (15 x 0,5 eurocents/second) x (2 measurements x 50 beds x 365 days) = more than 2,700 Euros per year. The battery needing is also favorable to Thermofocus. Hence, we can assume that each Thermofocus makes the Hospital saving from 4,000 to 5,000 Euros per year! - thanks to its new patented quick stabilization technology MQCS, Thermofocus 0800H5 stabilizes to room temperature very quickly. A plus which makes it particularly indicated for hospital use, where room temperature can change from room to room, as well as on ambulances; - Thermofocus 0800H5 avoids disturbing the patients during the measurement of body temperature, thanks to its display backlight function. This function makes Thermofocus 0800H5 perfect to be used with children, elderly people, sleeping patients, also during the night, without needing to turn on the light in the room. More attention to the comfort of the patient and less troubles, without any additional cost. 2

MAIN FEATURES Thermofocus 0800H5 implements a list of new functions, created to maximize its performances and its use in a sanitary contest: - MQCS technology (Manual Quick Calibration System), a new exclusive and patented function which allows doctors, nurses and hospital staff to take temperatures easily and precisely even if they are moving quickly from room to room. Thanks to this feature, Thermofocus 0800H5 is ideal for use by ambulance personnel when working at patient s home; - special lanyard with additional brief instructions - to be worn around the neck - and special mirror Target Disc, to be put in the rooms, which allows to better and quicker accomplish the MQCS (additional mirror target discs are available on request); - amber - colored LED lights (completely harmless); - default setting "nurs": MQCS requested and mandatory every 15 minutes (when used by nurses as well as for any intensive use, like in airports etc.); - optional setting "doct": if the thermometer s temperature is changing, the AQCS (Automatic Quick Calibration System) is automatically activated and allows the rapid stabilization of the thermometer to the room temperature: the display shows a countdown indicating the time required. To make a measurement is necessary to wait the end of the countdown without touching the device or is possible to do the manual MQCS (suggested procedure). Using the face button it is possible to take also surface temperatures (different from the body temperature) between 1 to 55 C (33.8 to 131 F). The display will show alternatively the temperature value and Lo.3, if the value is <34 C (93.2 F), or Hi.2, if it is > 40 C (104 F). These measurements are not entirely accurate and must be considered as relative rather than absolute values. If taken on the skin, these values will show the difference between two close or symmetrical areas (i.e. the two hands, the two knees, etc.). This setting is studied for doctor s use and also for the use in a specific ward as the Emergency Room; - Temperature level alarm: in order to attract the attention of the operator if the temperature is 37,0 C ( 98.6 F) or 38.0 C ( 100.4 F), the optical aiming system flashes quickly for 6 seconds (instead of the normal 2 seconds), and the display shows alternating the message Hi.2 to the data. - air conditioning On or Off in case of high air conditioning in the room; - display backlight, which lasts for 2 seconds after each measurement; - light bulb button which permits to reactivate the display backlight for 2 seconds, to show the last measurement and to change the settings/modes; - additional instructions on the battery door; - Using the FACE button, it is possible to take any temperature from 1 to 55 C/33.8 to 131.0 F. The display will show alternately the temperature value and Lo.3, if the recorded value is <34 C/93.2 F or Hi.2, if it is>37 C or 38 C (98.6 or 104 F) depending on the Alarm level. 3

With Thermofocus 0800H5, flexibility, accuracy and repeatability of the measurement are always guaranteed, thanks to its innovative and patented optical aiming system, which allows to determine in any condition the correct distance between the thermometer and the measurement area. APPLICATIONS Thermofocus 0800H5 is multipurpose and can be used for: - measuring the body temperature; - scanning specific areas of the skin, in order to detect the temperature difference between healthy areas and areas where there are anomalies due to inflammations, circulatory diseases, diabetes; - measuring the temperature of open wounds or organs during surgical interventions, in order to know the difference from healthy areas, ensuring maximum hygiene thanks to the total absence of contact. MANUFACTURING AND QA THERMOFOCUS is manufactured by Tecnimed within its factory in Vedano Olona (Italy) under the ISO 9001:2015, the ISO 13485:2016 Quality System. The production, control and calibration of THERMOFOCUS are performed in a temperaturecontrolled room. Packaging is done in an ambient-controlled room. The quality of the product is further certified by external independent institutes. PATENTS Thermofocus is protected by following patents: MI 1.284.119, EP 0909.377, US 6.196.714, IL 127.876, JP 504.769/98, EP 1.283.983, US 7.001.066, JP 3.863.919 and other international patents pending. 4

TECHNICAL FEATURES No. of buttons 2 LED lights color Amber Room temperature detection Resolution 0.1 C (0.1 F) Measurement time < 0,5 seconds Time between consecutive measurements <2 seconds Forehead measuring range 34.0/42.5 C (93.2/108.5 F) General measuring range (apart from forehead) 1.0/55 C (33.8/131 F) MQCS (Manual Quick Calibration System) NURS: mandatory every 15 minutes DOCT: available but not mandatory Room temperature working range for 16/40 C (50/104 F)* measurement on the forehead Room temperature working range for 5/40 C (41/104 F)*+ other measurements * Thermofocus 01500 A/H1N1 can work also in environments with a temperature between 5 and 15.9 C (41/60.6 F), but in this case the accuracy is not guaranteed and the message Lo.5 and the temperature value are displayed alternatively. Protective cap Display backlight Weight Batteries (included) Batteries life Standard At request 92 grams 4 AAA/LR03 type (alkaline) Up to 20.000 measurements AVAILABLE SETTINGS: nurs (default) doct AIR YES ( air conditioning on) AIR NOT ( air conditioning off ) Temperature level alarm MQCS mandatory every 15 minutes AQCS automatically activable and MQCS not mandatory. Measuring range from 1 to 55 C (from 33.8 to 131 F) 37,0 C ( 98.6 F) or 38,0 C ( 100.4 F) ACCURACY LEVEL (IN INSTRUMENTAL TESTS ACCORDING TO ASTM E 1965-98 (2009) STANDARD) Forehead measuring range from 36 to 39 C (96.8/102.2 F) = +/-0.2 C (+/-0.4 F) from 34 to 35.9 C (93.2/96.6 F) = +/-0.3 C (+/-0.5 F) from 39.1 to 42.5 C (102.4/108.5 F) = +/-0.3 C (+/-0.5 F) General measuring range out of the body temperature from 1 to 55 C (33.8/131 F) The measurements are not entirely accurate and must be considered as relative rather than absolute values. Distance from the subject during operation: about 3 cm (1.2 inch), set through an optical signal ACCESSORIES Brief additional instructions printed on battery door Lanyard with additional brief instructions Batteries 1 included 1 included N 4 AAA/LR03 type (alkaline) included 5