Operating Instructions!

Similar documents
Read these instructions before using and keep them available at all times!

Operating Manual. VIENNA Hot Display

L / -014L / -015L

Installation instructions

Operating Instruction

USER S MANUAL ATH WH220

User instructions. 3 ZE built-in ultrasonic baths and B standards for aqueous fluids. valid for: ZE 1031 ZE 1032 ZE 1058 ZE 1059 ZE 3000

TTV 4500 / TTV 4500 HP / TTV 7000

KITCHEN EXHAUST FAN GLEC-6 INSTALLATION AND MAINTENANCE

Super Elite Watch cleaning machine

MANUAL Oil Level Sensor

Read these instructions before using and keep them available at all times!

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Waste water ejection unit

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

ART cm Island Curved Glass

Operating Instructions RM 90. Watch Cleaning Machine. english

Read these instructions before using and keep them available at all times!

Procedure for the Approval of New Fire Detection and Alarm Technologies

ISCG90SS _03 ISCG90SS

+ English + 1. Safety warnings

IDNr.: KH /03. Kompernaß Handelsgesellschaft mbh Burgstraße 21 D Bochum UK

Operating Instructions

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

EHA Hoffmann International GmbH

Virtu 60 and 80 series. Coffee machine

4 liter Solo and 8 liter Combi

Operation Manual Vortex mixer unitexer 1

GLEB. >> Installation and Maintenance. Air Comfort. Air movement. Duct & Box Fans

Tower Fan MODEL# EE-5607

INSTRUCTIONS FOR USE

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Propane Flame Projector Safety instructions and operating manual

COOL TOUCH ELECTRIC WATER KETTLE

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

Domestic Hot Water Tank

235L G. Original-Gebrauchsanleitung V1/1115

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Operating Instructions

Instructions for Use S / SONOBOARD. Ultrasonic bath. for MIS and standard instruments

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Kitchen Appliance Lift INSTRUCTION MANUAL

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Operating instructions

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

KK70 Silent. Installation and Operating Instructions L V001

USER MANUAL. Electric Open Well Steam Tables. Models: 423EST2WE, 423EST3WE, 423EST4WE500, 423EST4WE750, 423EST5WE

MOD. 605 E. Made in Italy INSTRUCTION MANUAL

1.5L Fryer v1.0. Model: SD6060N. Helpline. SD6060N_IM.indd 1 07/10/ :58

3-way switching valve

TDS 20 R / TDS 30 R / TDS 50 R

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Vacuum cleaner Instruction manual

Ropox Bathtub. Keep this manual with the product at all times! User Manual & Mounting Instructions PDF 6128 /

Alarm Switchgear AS1-M

THE SMOKE MUST GO. Consulting - Project Planning - Supply - Installation - Service

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Original Operation Manual Slow Juicer

Ventilator insert Silvento V... Installation directions - Please pass on to the user -

Operating Instructions

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

OPERATING INSTRUCTIONS

OPERATING MANUAL ORWAK March 2005 PUBL. NO Edition 4

Refrigerant Dryers Refrigerant Compressed Air Dryer with integrated DF Filters

AS 50 operating manual, 2013

Silicon Pyranometer GSM xx

STS 5070SS. EN Toaster. Copyright 2017, Fast ČR, a.s.

Coffee Machine Zia series

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Installation and operating instruction. Digital-Thermostat. Thermo 2

CG60/ 70/ 80/ 90/ 100 SS/BK

Operation Manual 322 KL

Operating Instruction English. Revision A Date author NH This operating instruction is not subject to updating.

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

Electromagnetic Locking Devices Performance Requirements

en Inverter FU 4/5. Operator s Manual

Height-adjustable Unit

Operating Instructions

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Operation Manual. Pond Pump Series HJ and CQP

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

User Manual. GPD 3000 e. gas detector

Operation Manual. Diaphragm pumps 2-headed. Types MP 101 Zp, MP 201 Ep MPC 101 Zp, MPC 201 Ep

Flashing Lights Controller: BSU 10x/20x/S

Owner & Operator s Manual. Table of Contents

Operating and Maintenance Instructions

GAN Electronic 750W/1000W DE EU

Explosion Protection Enclosure with integrated measuring system

Dry Bath Heating Systems

TDS 100. EN Operating Manual Electrical Fan Heater

RESISTENT EXTRA 3592, 3602 RESISTENT EXTRA PLUS 3592P, 3602P

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Transcription:

Operating Instructions! 3 4 Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed for correct use by means of these instructions. In case of improper use, the manufacturer does not take any responsibility for safety and proper functioning. Unauthorized changes/modifi cations will result in expiration of the!-conformity. 2816m GB/2014-05 1 65 years of experience in ultrasound

Contents 1 Safety instructions to be strictly observed...3 2 Purpose...4 2.1 General description of the unit...4 2.2 CE Conformity...4 3 Scope of delivery...4 4 Installation, assembly and connection...5 5 Start...5 6 Cleaning and care...6 7 Maintenance and repair...6 8 Technical data...7 Copyright & limit of liability This document may not be reproduced, either in full or in extracts, without prior approval of BANDELIN electronic GmbH & Co. KG, hereinafter referred to as BANDELIN. The German original is the binding version of this document. Any difference in the translation is not binding and has no legal effect. In case of any discrepancies between the translation and the original, the original version has priority. BANDELIN accepts no responsibility and liability for damage caused by improper handling or usage contrary to the intended purpose. The documentation was created with great care. Liability for indirect and direct damage arising because of incomplete or erroneous information in this documentation as well as in delivery and usage is excluded. 2014 1 2 GmbH & Co. KG, Heinrichstraße 3 4, Germany, 12207 Berlin, Tel.: +49-30-768 80-0, Fax: +49-30-773 46 99, info@bandelin.com 2

1 Safety instructions to be strictly observed General The ocillation may be used intended and according to this operating instructions only together with SONOREX TECHNIK RM - unit. From there additionally all safety instructions of the operating instructions of the used unit are valid. Keep units away from children and also away from persons not instructed for correct use by means of these instructions. Protect the unit against corrosive infl uences. Place the unit horizontally on a dry and solid base. Keep the unit s surface and control elements clean and dry! Use only connecting material supplied with the equipment. The operating instructions with safety instructions have to remain always with the unit and are to be strictly followed! With delivery of the equipment the operating instructions with the safety instructions are to be handed over. Damages and defects After the packing has been removed, check the housing and the operating elements of the unit for any damage which might have occurred during transport. If damage due to transport has been discovered, do not connect the unit to the mains supply, but report the damage immediately and in writing to the carrier and to your supplier. Save the original packing. In case of defects disconnect the mains supply immediately. The unit must only be repaired by authorised personnel or the manufacturer. Use only original parts or of the same quality for replacement! Exchange defective mains cable completely. Operation Connect the unit to a grounded safety socket only. Pay attention to environmental conditions (chapter 8). Do not allow the unit to run without supervision. Do not touch moving parts when the unit is in operation! There is danger of squeezing between edge of tank and bracket during operation of the oscillation (MO). Put on or take off cleaning goods and the basket from the bracket only when the unit is switched off. 3

2 Purpose 2.1 General description of the unit The electrically driven oscillation MO enables automatic movement of the baskets in tanks of the production line SONOREX TECHNIK RM. The oscillating movement of the parts to be cleaned reinforces the cleaning effi ciency of the ultrasonic irradiation and helps to remove dirt particles more effi ciently. The movement is generated by an electromechanically driven lifting rod with a bracket on which the basket is hung with its handles. The SONOREX TECHNIK-RM unit is standing on the basis of the oscillation and is fi xed against moving / shaking by feet supports. Important! Maximum load: oscillation MO 16.2 8 kg oscillation MO 40 10 kg Existing SONOREX TECHNIK RM units can be upgraded with an oscillation without modifi cations. Depending on the size of the unit the following combinations of units are feasible: oscillation MO 16.2 SONOREX TECHNIK RM 16 - units oscillation MO 40 SONOREX TECHNIK RM 40 - units The primary use is ultrasonic cleaning, but other processes like rinsing are also permitted and depend on the type of the SONOREX TECHNIK RM- unit. The units are operated with rotary knobs on the front side. It is recommended to use them as table devices. 2.2 CE Conformity The oscillations comply with the CE marking criteria of the following European directives: - Low-voltage directive - Electromagnetic compatibility directive (EMC) - Machine directive in their latest valid version. The Declaration of Conformity can be requested from the manufacturer. 3 Scope of delivery 1 unit MO 16.2 or MO 40 1 bracket 1 washer 1 screw Note: Tools for assembly are not included in the scope of delivery. 4

4 Installation, assembly and connection Assembly of the bracket: - Place the bracket onto the lifting rod and fi x it with the washer and the screw by hand. - Align the bracket to the front (see picture). - Hold the lifting rod with spanner 16 and fi x the screw tightly (Allen key 5 mm). Place the unit on an even and rigid base keeping a distance of at least 10 cm between adjacent structures. Place the SONOREX TECHNIK RM unit with the feet onto the feet supports. lifting rod bracket guide tube feet support timer Attach the provided stickers warning of hand injury to well visible places at the ultrasonic unit. Connect the unit to a grounded socket 230 V~ (± 10 %) 50/60 Hz. Hang the basket onto the bracket. 5 Start Set the desired oscillation time with the timer processing time (oscillation) starts. At the end of the desired time the oscillation stops. Timed operation - Turn the knob to the right the green pilot lamp lights up. - The timer switches off automatically after run-off of time. - You can reduce the time or switch the unit off by turning the knob back. green Continuous operation ( position) - Turn the knob to the left the green pilot lamp lights up. - The unit does not switch off automatically, turn the knob back to 0 in order to switch off. Motion downwards is caused only by the weight of the bracket and the weight of the goods to be cleaned. If the motion downwards is blocked for some reason or other, the oscillation device will not be damaged. The operational running noise of the oscillation is functional conditioned and can vary load dependent. At the end of the oscillation process the bracket might move down to the lower dead centre. This motion is not a malfunction. 5

6 Cleaning and care The lifting rod must be cleaned in regular intervals (approx. 4 weeks) by wiping. 7 Maintenance and repair The oscillations MO 16.2 and MO 40 are maintenance-free. If error reports, malfunctions or damage to the units occur, the units must no longer be used. Check with the manufacturer: BANDELIN electronic GmbH & Co. KG Heinrichstraße 3-4 12207 Berlin Service reception: Technical advice: Tel.: +49-30-768 80-13 Tel.: +49-30-768 80-19 Fax: +49-30-773 46 99 Fax: +49-30-773 46 99 The general terms of delivery of BANDELIN electronic GmbH & Co. KG shall apply. Attention! Repairs may only be done by authorized technicians or by the manufacturer. 6

8 Technical data SONOREX TECHNIK units are RFI-proofed and marked!. In conformity with DIN EN 60204-1, the limits as per EN 61000-6-1 and EN 61000-6-3. MO 16.2 MO 40 Mains supply: Housing: Guide tube: 230 V~ (± 10 %) 50/60 Hz, cable length 2 m stainless steel 1.4301 (AISI 304), drip-proof (IP 32) aluminium, anodized Exterior dimensions (l w h): 365 500 560 mm 560 450 665 mm Current consumption: 0,2 A 0,6 A Weight (net): 13 kg 19 kg Maximum load (basket included): 8 kg 10 kg Code No.: 8306 8303 Oscillation: Lifting frequency: 10/min Lifting: 40 mm Environmental conditions according to EN 61 010-1 Excess voltage category: II Degree of soiling: 1 Permissible relative humidity at 31 C: 80 % Permissible relative humidity at 40 C: 50 % Permissible temperature of surroundings: 5 to 40 C Dew formation not allowed 7

If service is required, please contact your supplier. 1 www.bandelin.com info@bandelin.com 65 years of experience in ultrasound BANDELIN electronic GmbH & Co. KG Certification EN ISO 9001:2008 EN ISO 13485:2012 Heinrichstraße 3 4 12207 Berlin GERMANY Tel.: +49 30 768 80-0 Fax: +49 30 773 46 99