nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Similar documents
Domestic AC Fans 230V Installation and Operating Guide. eco. 230V AC Base Models: icon eco icon icon icon

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Installation & Operating Instructions

Lo-Carbon Quadra Centrifugal Fan

Lucci Designer Hi Flow Exhaust Fan

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Lo-Carbon Quadra SELV

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Centrif Duo & Centrif Duo Plus

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

KADO LUX LED EXHAUST FAN 200

Silhouette Installation and Wiring Instructions

Lo-Carbon SELV Tempra

Lo-Carbon T-series Window & Roof Models

Installation & Operating Instructions

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

200W Frostwatch Radiant Heater Operation Manual

KADO LUX 3-IN-1 HEAT LIGHT EXHAUST

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

HS&S Alert No: 103 Date: 9 March 2017

BLOW DRY & GO HAIR KIT

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

HOTLINE:

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR DRYER MODEL C80002

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

User Instruction Manual

2 IN 1 JUICER AND BLENDER

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Wiring the fan correctly...

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

Paper Shredder. Installation & User Instructions Please keep for future reference 913/0153

Glass Chimney Hood. Installation & User Instructions Please keep for future reference

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Turbo Lite Corded Handheld Stick Vacuum

INDEX WARNINGS AND RECOMMENDATIONS 2 COMPLIANCE DECLARATIONS 3 RANGE AND SIZES 3 ELECTRICITY SUPPLY 3 INSTALLATION 4 INSTRUCTIONS FOR UNINSTALLING

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

FAN HEATER FH118 User Manual

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Personal Blender User guide

PERFORMANCE SLIMMING BELT

SH3020 USER INSTRUCTIONS

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

MODEL: BV400 Part No:

CoCo LoCo BLOW & GO NUTS DRYER. LSHD24 Instruction Manual

Whole Room Dryer WRD, WRD/110

Centrifugal extract and condensation control fans

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

9.5 OSCILLATING AIR CIRCULATOR FAN Instruction Manual

Safety and Instruction Manual

Autofill counter top water boiler

A4 Laminator. Installation & User Instructions Please keep for future reference 908/6197

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

e Bath Fan with Light User s Guide

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

Installation & User Instructions:

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Xpelair Simply Silent TM Contour Fan

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

e Heater/Exhaust Fan/Light User s Guide

Installation and User Guide Please leave this guide with the end user (for future reference)

Thank you for choosing EnviroVent

Safety and Instruction Manual

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

LUCCI WHITEHAVEN DC CEILING FAN

s l it l on for Infrared Heaters

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

INSTRUCTIONS AND WARRANTY

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

Cooker Hood Instruction Manual

Radiant Heater. Instruction Manual QH-200 N13275

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY SLOW JUICER MODEL N23001


20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

MODEL# GEG1800 ELECTRIC GRILL. PHOTO OF PRODUCT

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

pure indoor living HIGH PERFORMANCE desk fan MODEL: BSF002, ISF004 INSTRUCTION MANUAL

16 Stand Fan with Remote Control Model No: FS3-40R-30

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

EVG Extractors. Manual for Installation, Use and Maintenance

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Xpelair Simply Silent TM DX100 Fan

Transcription:

Domestic AC Fans 230V Installation and Operating Guide 230V AC Base Models: ico15 72683501 ico15c 72591501 ico30 72591601 ico60 72591701

ico Domestic Fan 230V Installation, Maintenance and Use ico Domestic Fans are available in 3 model sizes and can be fitted to a wall or ceiling. Each fan requires a suitable size hole through the wall or ceiling which connects into a duct venting to the outside. The external opening should be covered by a suitable external grill, available separately from Airflow Developments td. Airflow ico Model Options: 72683501-15 -100mm Axial Fan with maximum capacity of 19 l/sec. 72591501-15C -100mm Axial Fan with maximum capacity of 19 l/sec. 72591601-30 -100mm Mixed Flow Fan with maximum capacity of 32 l/sec 72591701-60 -150mm Mixed Flow Fan with maximum capacity of 72 l/sec The ico range can be used as a simple extract fan operated by a remote switch, or can be fitted with an internal control module, available separately to give a range of control options including timer, humidity, motion sensor, pull cord, trickle speed or combinations of these functions. Optional modules are available separately and can be fitted at the time of installation or retrofitted. The ico Fan has an IP X4 rating housing and is suitable for mounting in Zone 2 in bathrooms, toilets, kitchens, utility rooms and inside shower cubicles as defined in Section 701 BS7161:2008 (IEEE wiring standards, 17 th Edition ). They also comply with the latest Building Regulations. Do not place the ventilator near direct heat sources, e.g. radiant heaters, or where temperatures can exceed 40 C (104 F). The Fan requires a 230V 50Hz single phase supply. Class II equipment. BS E 60417. An external 3A fuse is required for each fan unit. ote: Switches for fans should be selected and sited in accordance with BS7161:2008

All electrical installation to be carried out by an approved electrician in accordance with Part P U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance The fan is to be installed so that the blades are more than 2,1 m above the floor( for fans intended to be mounted at the high level) AWAYS ISOATE THE POWER SUPPY UIT AD FA UIT FROM THE POWER SUPPY BEFORE REMOVIG THE COVER. Mechanical Installation ico Domestic Fan can be recessed in a wall or ceiling. A mounting skirt is provided for surface mounting the ico 30 and ico 60. To avoid the backflow of condensation into the fan in a ceiling installation it is good practice to fit a CODESATIO TRAP to the outlet duct of the fan. Ensure free running of the fan impeller and that flexible duct connections are not over tightened to the fan outlet spigot. Airflow recommends that rigid ducting is used instead of flexible ducting, this will ensure maximum performance Front Cover Removal UDO THE RETAIIG SCREW AT THE BOTTOM EDGE OF COVER USIG A SCREWDRIVER. CODESATIO TRAP The front cover fan has a bayonet type fitting. To remove, undo the retaining screw at the bottom edge of the cover using a screwdriver, then rotate the cover a few degrees anticlockwise and remove. To refit, reverse the above procedure.

Recessing Fans in the Wall The ico 15 and ico 15C requires a 110mm diameter hole through the wall lined with a 100mm id (internal diameter) duct. The ico30 requires a 110mm diameter hole through the wall, counter bored 160mm to a depth of 75mm. The 110mm hole should be lined with a 100mm id duct. The ico60 requires a 160mm diameter hole through the wall, counter bored 190mm to a depth of 75mm. The hole should be lined with 150mm id duct. Surface Mounting Fans on the Wall When surface mounting the ico30 and ico60 the supplied mounting skirt should be used. The ico30 requires a 110mm diameter hole through the wall lined with a 100 mm id duct and the ico60 requires a 160mm diameter hole through the wall, lined with a 150 mm id duct Recessing Fans in the Ceiling POSSIBE CABE ROUTIG CEIIG DUCT PYWOOD When recessing fans in the ceiling, a plywood support (min 18mm thick) should be mounted between the ceiling joists. Fans should not be fitted to unsupported plaster board. JOIST

The ico 15 and ico 15C requires a 110mm diameter hole through the ceiling. The fan should be fixed, with the screws provided, through the plaster board into the support. The ico30 will require a 160mm diameter hole and the ico60 a 190mm hole. Surface Mounting Fans on the Ceiling POSSIBE CABE ROUTIG MOUTIG SKIRT When surface mounting the ico30, the mounting skirt should be used. The ico30 requires a 110mm diameter hole through the ceiling and the ico60 a 170mm diameter hole. The surface mounted skirt to be fixed, with the screws provided, through the plaster board into the support. The fan is then fitted into the skirt. Where flexible duct is used the diameter must be maintained. DUCT JOIST PYWOOD

Electrical Installation All electrical installation to be carried out by an approved electrician in accordance with Part P U.K. Building Regulations and to the latest IEEE standards, or the appropriate regulations in the country of installation. ico Domestic Fans require a 230V 50Hz supply, it is double insulated so therefore does not require an earth. Fans installed in Zone 1 or Zone 2 must be at least IPX4 (splash proof) rated. Additionally, fans installed in Zone 1 must be SEV (Safety Extra ow Voltage) or IPX5 (jet proof) rated. Wiring with no control module fitted. RCD 3 AMP SWITCHED FUSE Optional Modules for ico 230V Wiring for control modules with external switching A 3 AMP SWITCHED FUSE Wiring for control modules with no external switching B RCD RCD 3 AMP SWITCHED FUSE S Refer to instructions supplied with (optional) modules for further information.

Maintenance SAFETY FIRST: AWAYS ISOATE THE FA UIT FROM THE POWER SUPPY BEFORE REMOVIG THE COVER. Warranty only covers the fan, not the reinstallation of this if required. When installed according to these instructions the ico Domestic Fans are completely safe. The materials used do not constitute a hazard. The module covers are made of a flame retardant material. Cleaning The external housing of the fan can be wiped with a damp cloth. Do not use household cleaners containing abrasives. Cleaning of the internal parts such as the impeller should be carried out using a soft brush. ote: Always ensure that the fan unit is isolated from the power supply before inserting the brush into the impeller duct. ever clean any parts of the fan assembly by immersing in water or using a dishwasher. Trouble shooting Tip: Take care not to over tighten the duct connection to the fan spigot. This can result in restricting the free rotation of the impeller and a thermal overload of the motor could occur causing short term fan failure. In the event of this occurring loosen the duct connection so that the impeller rotates freely within the spigot. The motor is fitted with an automatic reset after approximately 15 minutes and will restart the fan when reconnected to the module controller and mains supply. Warranty Applicable to units installed and used in the United Kingdom. Airflow guarantees the ico fan units and ico modules for 2 YEARS from date of purchase against faulty material or workmanship. Extended to 3 when registered @ airflow.com. Warranty only covers the fan, not the reinstallation of this if required. In the event of any defective parts being found, Airflow Developments td reserve the right to repair or at our discretion replace without charge provided that the unit: 1. Has been installed and used in accordance with the fitting and wiring instructions supplied with each unit. 2. Has not been connected to an unsuitable electrical supply. 3. Has not been subjected to misuse, neglect or damage. 4. Has not been modified or repaired by any person not authorised by Airflow Developments td 5. Has been installed in accordance with latest Building Regulations and IEEE wiring regulations. Airflow Developments shall not be liable for any loss, injury or other consequential damage, in the event of a failure of the equipment or arising from, or in connection with, the equipment excepting only that nothing in this condition shall be construed as to exclude or restrict liability for negligence. This warranty does not in any way affect any statutory or other consumer rights.

Range of Optional Modules Available Choose the 230V Module PCM Pull Cord: 72573602/B TM Adjustable Timer: 72612601/B HTM Humidity, Pull cord with Timer Overrun: 72687103/B PRTM Passive Infra-Red with Timer Overrun: 72687104/B PRHTM Passive Infra-Red/Humidity/Timer: 72687102/B CV2 Continuous Ventilation: 72675701B DTM Delayed Timer start AC: 7265702B 2SHM 2 Speed /Humidity/ Pull Cord boost AC: 72675703B Choice of Anthracite, Sandstone, Chrome and Silver covers ico 15 cover Anthracite 52634503B ico 30 cover Silver 52634507B ico 15 cover Silver 52634504B ico 30 cover Sandstone 52634508B ico 15 cover Sandstone 52634505B ico 60 cover Anthracite 52634509B ico 15 cover Chrome 52634502B ico 60 cover Silver 52634510B ico 30 cover Anthracite 52634506B ico 60 cover Sandstone 52634511B Iss 0