Aspirator with trap flask FTA-1

Similar documents
FTA-1 Aspirator with trap flask

Centrifuge/Vortex for PCR plates CVP-2

Peltier cooler/heater PCH-1 / PCH-2

ES-20 Orbital Shaker-Incubator

Intelli-Stirrer MSH-300i Magnetic Stirrer with hot plate

UVT-B-AR. DNA/RNA UV-cleaner box. Operating Manual Certificate. Medical Biological Research & Technologies

TS-100C. Thermo-Shaker with cooling for microtubes and PCR plates. Operating Manual Certificate. Medical Biological Research & Technologies

Recirculating Chiller RC350G-RC400G RC1400G-RC3000G. Operating Manual

High Output Vacuum/Pressure Pump

Pasto Sous vide water bath

1. About this edition of the operating manual

Unstirred Water Baths

Thermo shaker PHMP/ PHMP-4

Unstirred Water Baths

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

**BVC professional G

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

**BVC control G. * With 4l PP collection bottle for general aspiration tasks, completely autoclavable together with a 0.2 µm protection filter

Model # VWK-2 INSTRUCTION MANUAL

VACUSAFE. The aspiration system for safe disposal of liquids

User s Guide ENGLISH. Other languages available on our website:

MODEL 7000 SUCTION UNIT

Thermo shaker PHMP/ PHMP-4

Manual Page 1 of 8. Manual. Laboratory autoclave

CLS-1450 Series Spinner Flask Instruction Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual

ASPIRE Laboratory Aspirator

INSTRUCTIONS CertoClav EL

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

Operating Instructions

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

PARAFFIN SECTION MOUNTING BATH

USER MANUAL LEEC CLASSIC INCUBATOR. C100, C157 and C330

Installation & Operating Instructions

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

Dyna-Form Air. Alternating Pressure Relief Overlay System

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

CAUTION UM120W (RIGHT TANK) FOR WATER BORNE PAINTS ONLY UM120W (RIGHT TANK) SECTION IS NOT DESIGNED FOR USE WITH SOLVENT BASED PAINT

Further information at Fluid aspiration systems. economic, safe, comfortable. BVC basic, BVC control, BVC professional

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

Aquamax KF Oil Evaporator. User Manual

Shaking Water Bath OLS Aqua Pro

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

ROTARY VACUUM EVAPORATOR RVO 004

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

AUC Cell Washer. User Manual

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

Instructions for use Vacuum regulation valve with water trap

ELECTRIC BUNSEN INSTRUCTION BOOK. BA6101, BA6101/C, BA6101x1, BA6101x3. Page 1 of 20 M6877 Issue 9.6

Chemical resistant Vacuum Pumps

ELECTRIC ASH CAN Model: CVACASH500 Part No:

SASE BULL 240C. Dust Collection System Manual

Laboratory filtration systems.

Instructions. Portable Absorb Phlegm. Apparatus

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

MEDIST s.r.o., Petrusovskeho 4, Humenne, Slovakia Tel.: , Fax: ,

Aluminum Heating Mantles

Harvester Operation and Service Manual

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Methods of solid phase extraction. Methods of solid phase extraction

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Laboport Chemically-resistant Laboratory Pumps and Systems

Bona Portable DCS Manual and safety instructions

Vacuum Controller with Control Unit VC 900

Models: GW/R-T GW/R-2-T GW/R-3-T

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

Vacuum Pump V-300 Operation Manual

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

Sip Vacuum Cleaner 1400/35 Wet & Dry

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

Vacuum Pump V-100 Technical data sheet

Vacuum cleaner Instruction manual

3. Thermal switch (70 o C thermostat) with a 3 m connection cable

SW-2 SNOW MACHINE. Item ref: UK User Manual

Refrigerated Incubator Model and Operating Instructions

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

8070 Mytee Lite. Instructions for. Please read before use. Register your product at support/register.

USER MANUAL. 60cm, 3 burners, Hob AKC 630

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

LABOPORT. Chemically-resistant Laboratory Pumps with Modular Accessories. Operating Instructions for Laboratory Pumps. and for LABOPORT Systems

A few simple steps to ensure perfect water, every time.

Thermo-Sealer. Manual Heat Sealer. User Manual

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

Please read and digest ALL the instructions before you commence installation.

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

Installation Manual

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

AMPHASYS AG TECHNOPARK Lucerne Platz 4 CH-6039 Root D4 Switzerland phone

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

Vacuum Pump Kit User Manual

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

GE Healthcare. Mixer M-925. Instructions

INSTRUCTIONS SUCTION PUMP. CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician.

ELISA Plate Washer MICRO WASH 1100 Page 1 of 29

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

Transcription:

Aspirator with trap flask FTA-1 For version V.4GW

Contents 1 Safety...3 2 General Information...5 3 Getting started...6 4 Operation...7 5 Specifications...9 6 Guarantee and service...10 7 Declaration of Conformity...11 Page 3

1. Safety The following symbol means: Caution! Read these operating instructions fully before use and pay particular attention to sections containing this symbol. GENERAL SAFETY Operation of the unit must be carried out according to the given operating instructions. The unit should not be used if dropped or damaged. After transport or storage in humid conditions dry out the unit (2-3 hrs) before connecting it to the mains. Before using any cleaning or decontamination method except those recommended by the manufacturer, check with the manufacturer that the proposed method will not damage the equipment. Do not attempt to modify the unit. ELECTRICAL SAFETY Connect only to an external power supply with voltage corresponding to that on the serial number label. Use only the external power supply unit provided with this product. Ensure that the external power supply and switch is easily accessible during use. Before moving the unit disconnect the external power supply from the mains outlet. If liquid is spilt inside the unit, disconnect it from the external power supply and have it checked by a competent person. DURING OPERATION Do not operate the unit in premises with aggressive or explosive chemical mixtures. It is not allowed to use aggressive organic compounds, chlorinated solvents, strong conjugated acids for operation with the unit. Do not operate the unit outside the laboratory premises. Page 4

Do not operate the unit if you think it may have been incorrectly installed or repaired. Do not leave the operating unit unattended. BIOLOGICAL SAFETY It is the user's responsibility to carry out appropriate decontamination if hazardous material is spilt on or inside the equipment. Do not allow the collected buffer level to exceed the max. level (see Figure 1/5). Empty the trap flask when the liquid level reaches maximum. Take necessary precautions utilizing waste liquid in accordance with general laboratory standards. Page 5

2. General Information is designed for aspiration (removal) of alcohol (or buffer) remaining quantities from microtest tube walls during DNA (RNA) purification and other macromolecule reprecipitation techniques. FTA-1 can also be used for routine operations of cells washing from cells culture medium and resuspension in buffer. The aspirator operation principle is based on creating negative pressure in trapping flask by the microcompressor. The trap flask is connected with a collecting to the tip by a silicone tube. Liquid is removed from the microtest tube when the tip touches the solution surface. There is a tube holder for 2 tubes conveniently located on the right hand side of the unit, these tubes can hold acid solution and distillate for the collecting tip to be washed and stored for re-use. A hydrophobic microbiological filter eliminates risk of contamination from the trap flask with bacteria, viruses and infected particles. Hydrophobic microbiological filter holds particles bigger than 0.027 micron with up to 99.9% efficiency. In order to prolong serviceability and efficiency of device it is important not to use aggressive organic compounds such like phenol and strong conjugated acids such like guanidine for aspiration. It can cause damage not under warranty! Please, contact manufacturer to confirm chemical resistance of any liquids which are not mentioned here. Page 6

3. Getting started 3.1. Unpacking Remove packing materials carefully and retain for future shipment or storage of the unit. 3.2. Complete set Unit set includes: Standard set - Aspirator FTA-1...1 pce. - Trap flask...1 pce. - Hydrophobic microbiologic filter...2 pce. - Aspiration tubes with fittings...1 set - Aspiration tip...1 pce. - Storing tube for aspiration tip...1 pce. - External power supply...1 pce. -, Declaration of conformity...1 copy Optional accessories - 8-channel aspiration manifold MA-8 with holder...1 pce. 3.3. Set up - place unit on an even working horizontal surface; - install the trap flask on the unit; - screw the lid with the filter, inlet and outlet silicone tubes on the trap flask; - screw the tube coming out from the filter to the socket connector of the pump (Fig.1/1) located on top of the unit (turning clockwise); - ensure that the filter is tightly inserted in the socket (Fig.1/2); - place the tube into a holder (fig.1/4) situated at FTA-1 right hand side. - plug the external power supply into the socket at the rear side of the unit and position the unit so that there is easy access to the external power supply and the power switch. Page 7

2 5 1 3 - Max. Level- 4 6 Fig.1 Assembled unit 3.4. Optional aspiration tip MA-8 installation - remove tubes from the holder situated at FTA-1 right hand side (fig.1/4); - place MA-8 storing holder (fig.1/1) into the holder (fig.2/ ); - remove standard aspiration tip from the inlet tube (fig.1/6) and connect the aspiration tip MA-8 (fig.2/2); 1 2 Fig.2 Optional aspiration tip MA-8 installation Page 8

4. Operation 4.1. Connect external power supply unit to the mains. 4.2. Switch ON the unit with the Power switch on the side surface (fig.1/3). 4.3. Touch the solution surface with the aspiration tip to remove liquid from a test tube. 4.4. Use the mini-holder (Fig. 1/4) situated at the right side of the unit for washing and storing the aspiration tip. Holder designed for 2 tubes (e.g. for hydrochloric acid solution and distillate). Caution! During operation do not allow the collected buffer level to exceed the max. level (see figure 1/5). Empty the trap flask when the liquid level reaches maximum (according to p. 4.6). 4.5. After finishing the operation switch OFF the Power switch (fig. 1/3) and disconnect the external power supply from the mains outlet. 4.6. Take necessary precautions utilising waste liquid in accordance with general laboratory standards. Page 9

5. Specifications The product is designed for operation indoors in a laboratory at altitudes up to 2000m, with ambient temperature from +4 C to +40 C and maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. Vacuum...-500 mbar Filtration... hydrophobic microbiologic filter 2200/02 eliminates risk of contamination from the trap flask with bacteria, viruses and infected particles Diameter of filter pores... 0.027 micron Dimensions...160x210x340 mm Input current/power consumption...12v, 0.3 A / 3.6 W External power supply...input AC 100-240 V 50/60Hz, output DC 12V Weight with trap flask, not more...1.7 kg Optional accessories see. fig.3 Replacement parts Description 8-channel aspiration manifold MA-8 with holder Description Outgoing filter tube adapter (90 ) with short tube Hydrophobic microbiologic filter FA-1 Adapter between cap and hidrofobic filter Small 90 elbow Trap flask 1L with lid, cup insert and sealer Page 10

Replacement parts Description UNF male threaded adapter Aspiration tip 200 mkl Adapter between tube and aspiration tip Female luer bulkhead - hose barb adapter Male luer lock - hose barb adapter see. fig.3 see. fig.3 Silicone tube set 6 pcs. (outer x inner diam. x lenght mm: 8x5x300, 8x5x25, 8x5x16, 5x3x850, 5x3x50, 5x3x15) Tubing set (all tubes with fittings except filter, aspiration tips, adapters for 8-channel manifold) MA-8T, 8-channel aspiration tip for MA-8 Fig.3 Replacement parts Grant is committed to a continuous programme of improvement, specifications may be changed without notice. Page 11

6. Guarantee and Service 6.1. Guarantee When used in laboratory conditions according to this instruction, this product is guaranteed for TWO YEARS against faulty materials or workmanship. 6.2. Service & Maintenance It is recommended to change the tubes every six months (see p. Specifications table for item name of Tubing set). It is recommended to change the microbiologic filter once in six months; in particular cases, e.g. at intensive laboratory research studies, once in three months (to order the filter, see p. Specifications table for item name). Filter replacement (Fig.1/2). Disconnect the inlet and outlet tubes from the filter, remove the filter, insert a new filter into the socket and tighten it. IN Attention! Observe location of the filter according to Fig.4. IN marking should be located on the side of the inlet tube (closer to the trap flask)! For other maintenance and repairs return to our service department in the UK or in other countries, our distributor. 6.3. Cleaning & Disinfection Fig.4 Filter mount Standard ethanol (75%) or other cleaning agents recommended for cleaning of laboratory equipment can be used for casing cleaning and disinfection of the unit. It is recommended to perform internal washing of tubes, adapters and tips with distilled water (volume 0.5 l or more). Page 12

Grant Instruments (Cambridge) Ltd Shepreth Cambridgeshire SG8 6GB UK Tel: +44 (0) 1763 260811 Fax: +44 (0) 1763 262410 Email: scientificsales@grantinstruments.com www.grantinstruments.com Aspirator with trap flask / FTA-1/4.02