SPLIT SYSTEM HEAT PUMPS 14 SEER

Similar documents
SPLIT SYSTEM HEAT PUMPS "ERC" Series

SPLIT-SYSTEM CONDENSING UNITS. HRC Series TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE STELLAR 2000 TM MODELS: E*FD018 THRU E*FD060 1 Ø E*FD036 THRU E*FD060 3 Ø SPLIT-SYSTEM HEAT PUMPS Rev A (0500)

SPLIT-SYSTEM CONDENSING UNITS. "HRC" Series SEER. Models H*RC018 thru H*RC060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

TECHNICAL GUIDE STELLAR 2000 TM MODELS: H*DB012 THRU H*DB076 (1 Ø & 3 Ø) SPLIT-SYSTEM AIR CONDITIONERS A TG2Y (02/00) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

2220 SE Ninth Avenue 2113 Delta Waters Road Portland OR Medford OR

Split System Cooling Product & Performance Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

R4H4. Product Specifications

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

September, Ductless Split Ceiling Cassette Ductless Mini-Split Models SSD, SSH and SCW

R4H4. Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Split System Heat Pump Product Data

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Commercial High-Efficiency Condensing Units

Split System Heat Pump Product Data

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

Split System Cooling Product Data

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Split System Heat Pump Product Data

Split System Heat Pump Product & Performance Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

Split System Heat Pump Product Data

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

Split System Heat Pump Product Data

Split System Cooling Product Data

N4H4. Product Specifications

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

50TM COMBINATION HEATING/COOLING UNITS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

14 AC x

SKYPAK II Heating & Cooling Self Contained Packages

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

50TM TFF COMBINATION HEATING/COOLING UNITS

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

TECHNICAL SPECIFICATIONS

Split System Cooling Product Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Split System Cooling Product Data

seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Split System Cooling Product Data

TECHNICAL SPECIFICATIONS

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

WJH4 Product Specifications

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Split System Cooling Product Data

N4A6. Product Specifications

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

T P A 120 S 4 S N 1 Y

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Split System Cooling Product Data

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

Model 655A Sizes

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

High Heat COP. High/Low Stage

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Product Data. Features/Benefits. 28CB, 28LA Direct-Expansion. evaporator coils. 7 1 / 2 and 10 Nominal Tons Cooling

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

PACKAGE AIR CONDITIONER

Transcription:

(498) SPLIT SYSTEM HEAT PUMPS 14 SEER Models E*RE0 thru E*RE048 Nominal Capacity: thru 48 MBH DESCRIPTION The ERE series heat pumps are designed for use with a variety of UPG evaporator sections to suit any application need. A full line of matching Add-On Coils are available for use with upflow, downflow or horizontal furnaces. Matching Air Handlers are also available for upflow, downflow or horizontal installation to provide a complete system. Electric heat may be installed in air handlers. All units are factory charged to assure easy installation. FEATURES DURABLE FINISH - Cabinet is made of pre-painted steel. The pre-treated flat galvanized steel provides a better paint to steel bond, which resists corrosion and rust creep. Special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight. QUALITY CONDENSER COILS - The coil is constructed of copper tube and hardened black aluminum fins for durability and long lasting efficient operation. The decorative 2" x 4" grille backed by black coated fins, enhances appearance and protects the unit. PROTECTED COMPRESSOR - The compressor is internally protected against high pressure and temperature by the simultaneous operation of a high pressure switch and high temperature switches to stop the compressor if undesirable operating conditions occur. An oversized discharge line filter drier further protects the compressor. LOWER INSTALLED COST - Installation time and costs are reduced by the fully exposed refrigerant connections. Discharge line heat exchanger knockouts are provided, if required. Available in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping. The small base dimension means less space is required on the ground or roof. Start-assist components included as standard. TOP DISCHARGE - The warm air from the top mounted fan is blown up away from the structure and any landscaping. This allows compact location on multi-unit applications. LOW OPERATING SOUND LEVEL - The upward air flow carries the normal operating noise up away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil muffle the normal fan motor and compressor operating sounds. LOW MAINTENANCE - Long life permanently lubricated motor- bearings need no annual servicing. EASY SERVICE ACCESS - Fully exposed refrigerant connections, a single panel covering the electrical controls and the molex plug in the control box connecting the condenser fan, make for easy servicing of the unit. SECURED SERVICE VALVES - Secured re-usable service valves are provided on both the liquid and vapor sweat connections for ease of evacuating and charging. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

COOLING CAPACITY - With Air Handler Coils MODEL* MODEL 2 AIR HANDLER ELECTRIC HEAT KW W COIL 2 MODEL RATED CFM TOTAL NET MBH SENS. COOLING KW SEER/ TXV 1 / BOD 3 ERE / NAH E1RE0 N-AHB08 2,5,8,10 17.5 G2FD046S17 800.2 18.0 1.99 14.00 12.15 E1RE030 N-AHB12 N-AHD14 N-AHD20 17.5 G2FD046S17 G2FD042S G2FD048S G2FD048S G2FD060S 1000 30.0 29.5 30.5 30.4 30.5 22.0 22.0 22.0 22.5 22.0 2.56 2.53 2.56 2.55 2.55 13.40 13.00 13.80 14.00 13.80 11.70 11.65 11.90 11.90 11.95 E1RE036 E1RE042 E1RE048 E1RE0 E1RE030 E1RE036 E1RE042 E1RE048 N-AHB12 N-AHD14 N-AHD20 8,10,15,18,20,25,30 8,10,15,18,20,25,30 N-AHD20 N-AHD20 8,10,15,18,20,25,30 N-AHD20 8,10,15,18,20,25,30 17.5 G2FD046S17 G2FD042S G2FD048S G2FD060S G2FD060S G2FD048S G2FD060S G2FD048S G2FD060S G2FD061H 1200 1400 1600 35.0 34.5 36.0 36.0 36.0 42.0 43.0 45.0 45.5 46.0 26.2 25.8 27.0 26.6 26.6 29.8 30.5 32.9 33.0 33.6 ERE / NVS - (VARIABLE SPEED AIR HANDLER) N-VSB12 N-VSC16 17.5 G2FD046S17 G2FD048S 800.8 25.4 18.4 18.6 N-VSB12 17.5 G2FD046S17 30.5 22.4 N-VSC16 G2FD042S 1000 30.0.8 N-VSC16 G2FD048S 31.0 22.8 N-VSC16 N-VSB12 N-VSC16 N-VSC16 N-VSD20 8,10,15,18,20,25,30 N-VSD20 N-VSD20 8,10,15,18,20,25,30 8,10,15,18,20,25,30 17.5 G2FD042S G2FD046S17 G2FD048S G2FD048S G2FD060S G2FD060S G2FD061H 1200 1400 1605 35.0 35.5 36.5 43.0 44.0 46.5 47.0 26.0 26.6 27.4 30.9 31.7 34.0 34.5 2.99 2.99 3.04 3.00 3.00 3.64 3.66 3.93 3.89 3.88 1.81 1.85 2.37 2.40 2.43 2.77 2.82 2.81 3.47 3.37 3.50 3.52 13.10 13.00 13.50 14.00 13.80 13.25 13.50 13.00 13.25 13.50 16.00 16.00 15.00 14.40 15.00 14.50 14.40 15.00 14.35 15.20 15.10 15.30 EER 11.70 11.55 11.85 12.00 12.00 11.55 11.75 11.45 11.70 11.85 13.7 13.7 12.85 12.50 12.75 12.65 12.60 13.00 12.40 13.05 13.30 13.35 AIR HANDLER COOLING COIL MODEL* MODEL 2 ELECTRIC MODEL HEAT KW W RATED NET MBH SEER/ CFM KW TXV 1 / EER TOTAL SENS. BOD ERE / F*RP / F*FP E1RE036 F2RP/F2FP042 5,8,10,15-1200 34.5 25.6 3.03 12.80 11.40 E1RE042 F2RP/F2FP048 5,8,10,15,20-1400 42.0 29.8 3.72 13.00 11.30 E1RE048 F2RP/F2FP060 5,8,10,15,20-1600 45.0 32.6 4.05 12.65 11.10 Rated in accordance with DOE test procedures (Federal Register 12-27-79 + 3-18-88) and ARI Standards 0. Cooling MBH based on 80 F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU s at a 95 F outdoor ambient divided by the total electric power in watthours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1 TXV = Thermal Expansion Valve Kit Required. 2 To meet R=4.2 insulation requirements, substitute F1FP for F1RPmodels. All ratings remain the same. 3 P3HU, P3DN, and P3UR furnaces and FRP/FRC air handlers have B.O.D. standard (included in performance rating). * All models are single phase, unless noted otherwise. = Not Applicable. 2 Unitary Products Group

COOLING CAPACITY - With Upflow, Horizontal, Downflow Furnace and Coils MODEL* FURNACE CFM RANGE E1RE0 650-950 E1RE030 850-1150 E1RE036 1000-1400 E1RE042 1200-1600 E1RE048 1350-1750 See Notes on Page 2 W COIL MODEL RATED CFM COOLING NET MBH SEER/ TOTAL SENS. KW TXV 1 / BOD 3 EER.4 17.1 2.00 14.00 12.20 G1NA048SD 17 G1UA048S17.2 18.0 1.99 14.00 12.15, G1UA048S, 800.4 17.8 2.00 14.00 12.20 17 G2FD046S17.2 18.0 1.99 14.00 12.15, G2FD048S,.6 18.0 2.00 14.20 12.30 G1NA042SW 31.0.6 2.56 14.00 12.10 17 G1UA048S17 30.0 22.0 2.56 13.40 11.70, G1UA048S, 30.5.0 2.55 13.80 11.95 G1UA060S 30.5 22.0 2.55 13.80 11.95 - G1NF060SOF 1000 31.0.6 2.56 14.00 12.10 G2FD042S 29.5 22.0 2.53 13.00 11.65 17 G2FD046S17 30.0 22.0 2.56 13.40 11.70, G2FD048S, 30.5 22.0 2.56 13.80 11.90 G2FD060S 30.5 22.0 2.55 13.80 11.95 G1NA042SW 36.5 26.0 3.04 14.00 12.00 17 G1UA048S17 35.0 26.2 2.99 13.10 11.70, G1UA048S, 36.0 25.8 3.08 13.30 11.70 G1UA060S 36.0 26.6 3.00 13.80 12.00 - G1NF060SOF 1200 36.5 26.0 3.04 14.00 12.00 G2FD042S 34.5 25.8 2.99 13.00 11.55 17 G2FD046S17 35.0 26.2 2.99 13.10 11.70, G2FD048S, 36.0 27.0 3.04 13.50 11.85 G2FD060S 36.0 26.6 3.00 13.80 12.00 G1NA042SW 42.5 29.8 3.66 13.50 11.60, G1UA048S, 41.0 28.7 3.69 13.00 11.60 G1UA060S 43.0 30.5 3.66 13.50 11.75 1400 - G1NF060SOF 42.5 29.8 3.66 13.50 11.60, G2FD048S, 42.0 29.8 3.66 13.25 11.55 G2FD060S 43.0 30.5 3.66 13.50 11.75, G1NA042SW 1500 46.0 32.7 3.90 13.50 11.80 G1UA060S 1600 45.5 33.0 3.89 13.25 11.70 - G1NF060SOF 1500 46.0 32.7 3.90 13.50 11.80, G2FD048S, 1600 45.0 32.9 3.93 13.00 11.45 G2FD060S 1600 45.5 33.0 3.89 13.25 11.70 G2FD061H 1600 46.0 33.6 3.88 13.50 11.85 SOUND RATINGS MODEL ERE SOUND RATINGS BELS 0 72 030 73 036 77 042 76 048 78 CERTIFICATION APPLIES ONLY WHEN USED WITH PROPER COMPONENTS AS LISTED WITH ARI Unitary Products Group 3

HEATING PERFORMANCE - ERE / AIR HANDLERS and FURNACE COILS MODEL* 0 030 036 042 048 COIL 1 MODEL ARI HEATING 2 OUTDOOR TEMP 3 47 F 17 F HSPF -3 F 7 F 17 F 27 F 37 F 47 F 57 F MBH COP MBH COP STD VS MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW MBH KW G1NA048SD.0 3.60 15.0 2.50 9.00-9.0 1.63 12.0 1.69 15.0 1.76 17.6 1.81 20.1 1.86.0 1.95 27.0 2.02 G1UA048S17 23.8 3.65 14.8 2.50 8.50-8.8 1.62 11.8 1.68 14.8 1.73 17.1 1.78 19.5 1.84 23.8 1.91 26.8 1.97 G1UA048S,.0 3.75 15.0 2.55 9.00-9.0 1.62 12.0 1.67 15.0 1.72 17.3 1.76 19.7 1.79.0 1.86 27.0 1.93 G2FD046S17 23.8 3.65 14.8 2.50 8.50 9.00 8.8 1.62 11.8 1.68 14.8 1.73 17.1 1.78 19.5 1.84 23.8 1.91 26.8 1.97 G2FD048S,.2 3.80 15.0 2.60 9.00 9.25 8.7 1.57 11.9 1.63 15.0 1.69 17.3 1.74 19.7 1.80.2 1.87 27.3 1.92 G1NA042SW 30.0 3.75 19.8 2.65 9.00-13.0 2.09 16.4 2.14 19.8 2.19.6 2.20 23.4 2. 30.0 2.34 33.4 2.40 G1UA048S17 31.0 3.30 20.6 2.40 8.00-13.7 2.36 17.1 2.44 20.6 2.51 22.5 2.56.4 2.61 31.0 2.75 34.5 2.83 G1UA048S, 31.0 3.45 20.4 2.45 8.50-13.3 2.31 16.9 2.38 20.4 2.44 22.2 2.46.0 2.47 31.0 2.63 34.5 2.70 G1UA060S 30.5 3.80 19.6 2.55 9.00-12.3 2.19 16.0 2.22 19.6 2.25.6 2.26 23.6 2.27 30.5 2.35 34.1 2.38 G1NF060SOF 30.0 3.75 19.8 2.65 9.00-13.0 2.09 16.4 2.14 19.8 2.19.6 2.20 23.4 2. 30.0 2.34 33.4 2.40 G2FD042S 31.0 3.30 20.6 2.35 8.00 8.25 13.7 2.45 17.1 2.51 20.6 2.57 22.4 2.58.2 2.58 31.0 2.75 34.5 2.81 G2FD046S17 31.0 3.30 20.6 2.40 8.00 8.50 13.7 2.36 17.1 2.44 20.6 2.51 22.5 2.56.4 2.61 31.0 2.75 34.5 2.83 G2FD048S, 30.5 3.70 20.8 2.60 9.00 9.20 14.3 2.30 17.6 2.32 20.8 2.34 22.5 2.33.1 2.32 30.5 2.42 33.7 2.44 G2FD060S 30.5 3.80 19.6 2.55 9.00-12.3 2.19 16.0 2.22 19.6 2.25.6 2.26 23.6 2.27 30.5 2.43 34.1 2.38 G1NA042SW 37.0 3.80 23.4 2.55 9.00-14.3 2.58 18.9 2.63 23.4 2.69 26.8 2.74 30.2 2.80 37.0 2.85 41.5 2.91 G1UA048S17 38.0 3.65 23.0 2.40 8.10-13.0 2.65 18.0 2.73 23.0 2.81.6 2.75 26.1 2.69 38.0 3.05 43.0 3.13 G1UA048S, 39.0 3.70 23.8 2.45 8.35-13.7 2.68 18.7 2.77 23.8 2.85 25.4 2.78 26.9 2.72 39.0 3.09 44.1 3.17 G1UA060S 38.5 3.85 23.2 2.50 9.00-13.0 2.58 18.1 2.65 23.2 2.72 26.4 2.76 29.6 2.79 38.5 2.93 43.6 3.00 G1NF060SOF 37.0 3.80 23.4 2.55 9.00-14.3 2.58 18.9 2.63 23.4 2.69 26.8 2.74 30.2 2.80 37.0 2.85 41.5 2.91 F2RP/F2FP042 38.0 3.60 23.0 2.40 8.00-13.0 2.62 18.0 2.71 23.0 2.81.6 2.78 26.1 2.74 38.0 3.09 43.0 3.19 G2FD042S 37.5 3.60 23.0 2.40 8.00 8.50 13.3 2.65 18.2 2.73 23.0 2.81.4 2.76 25.9 2.72 37.5 3.05 42.3 3.13 G2FD046S17 38.0 3.65 23.0 2.40 8.10 8.70 13.0 2.65 18.0 2.73 23.0 2.81.6 2.75 26.1 2.69 38.0 3.05 43.0 3.13 G2FD048S, 38.5 3.85 23.2 2.55 8.60 9.00 13.0 2.49 18.1 2.58 23.2 2.67 25.8 2.72 28.3 2.77 38.5 2.93 43.6 3.02 G2FD060S 38.5 3.85 23.2 2.50 9.00-13.0 2.58 18.1 2.65 23.2 2.72 26.4 2.76 29.6 2.79 38.5 2.93 43.6 3.00 G1NA042SW 42.5 3.70 27.4 2.55 9.00-17.3 3.00 22.4 3.08 27.4 3.15 31.0 3.16 34.7 3.17 42.5 3.37 47.5 3.44 G1UA048S, 44.0 3.60 28.2 2.50 8.60-17.7 3.12 22.9 3. 28.2 3.31 31.7 3.34 35.3 3.38 44.0 3.58 49.3 3.67 G1UA060S 43.5 3.75 27.2 2.55 9.00-16.3 2.94.8 3.03 27.2 3.13 31.5 3.17 35.7 3.22 43.5 3.40 48.9 3.49 G1NF060SOF 42.5 3.70 27.4 2.55 9.00-17.3 3.00 22.4 3.08 27.4 3.15 31.0 3.16 34.7 3.17 42.3 3.37 47.5 3.44 F2RP/F2FP048 43.5 3.75 27.4 2.50 8.50-16.7 3.12 22.0 3.15 27.4 3. 31.5 3.32 35.6 3.42 43.5 3.40 48.9 3.46 G2FD048S, 43.5 3.80 27.2 2.55 8.75 9.10 16.3 2.97.8 3.05 27.2 3.13 31.3 3. 35.4 3.35 43.5 3.35 48.9 3.43 G2FD060S 43.5 3.75 27.2 2.55 9.00 9.20 16.3 2.94.8 3.03 27.2 3.13 31.5 3.17 35.7 3.22 43.5 3.40 48.9 3.49 G1NA042SW 44.0 3.62 29.0 2.56 9.00 N/A 19.0 3.16.0 3. 29.0 3.32 31.8 3.33 34.6 3.35 44.0 3.56 49.0 3.64 G1UA060S 45.5 3.52 28.0 2.40 8.10 9.00 16.3 3.17 22.2 3.30 28.0 3.42 31.6 3.50 35.1 3.59 45.5 3.79 51.3 3.91 G1NF060SOF 44.0 3.62 29.0 2.56 9.00 N/A 19.0 3.16.0 3. 29.0 3.32 31.8 3.33 34.6 3.35 44.0 3.56 49.0 3.64 F2RP/F2FP060 46.0 3.42 27.6 2.34 7.85 N/A 15.3 3.13.5 3.29 27.6 3.46 31.7 3.63 35.8 3.81 46.0 3.94 52.1 4.10 G2FD048S, 46.0 3.50 27.4 2.36 8.00 N/A 15.0 3.10.2 3.25 27.4 3.40 31.2 3.51 35.0 3.63 46.0 3.85 52.2 4.00 G2FD060S 45.5 3.52 28.0 2.40 8.10 8.75 16.3 3.17 22.2 3.30 28.0 3.42 31.6 3.50 35.1 3.59 45.5 3.79 51.3 3.91 G2FD061H 45.0 3.78 28.6 2.56 9.00 9.20 17.7 3.13 23.1 3.20 28.6 3.27 31.9 3.31 35.3 3.34 45.0 3.49 50.5 3.56 1 Rated CFM same as for cooling. 2 Heating MBH based on ARI standards of 70 DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation. 3 Integrated heating capacities include the effect of defrost cycles in the temperature range where they occur. COP equals MBH output divided by (total KW input x 3.412). HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period. 4 Unitary Products Group

TYPICAL INSTALLATION - ERE0 thru 048 60" OVERHEAD CLEARANCE 18" SERVICE ACCESS CLEARANCE WEATHERPROOF DISCONNECT SWITCH THERMOSTAT TO FURNACE OR AIR HANDLER TERMINAL BLOCK NEC CLASS 1 WIRING NEC CLASS 2 WIRING 10" CLEARANCE COIL AREA TO INDOOR COIL NOTE: ALL OUTDOOR WIRING MUST BE WEATHERPROOF SEAL OPENING(S) WITH PERMAGUM OR EQUIVALENT CONTROL ACCESS PANEL TYPICAL FIELD WIRING Unitary Products Group 5

ACCESSORIES Refer to Price Manual for specific model numbers. Compressor Blanket - Designed to further reduce the normal operating sound and is required to meet Canadian sound levels for units of three tons and below. Blower Time Delay - 2FD067002 allows blower to run 60 seconds after the cooling thermostat has been satisfied. Hard Start Kit (Single Phase Units) - Provides required starting torque for use with themal expansion valve. Low Temperature Lockout - 2LT067002 - Prevents heat pump operation below minus 10 F ambient temperature. Outdoor Thermostat - 2TD067001 - Consists of an adjustable outdoor thermostat and relay ina vented enclosure. It provides additional second stage control of the supplemental resistance heat.(balance Point Control) Room Thermostats - One of the following thermostats may be used with these heat pump systems. 2TH117022 - Two stage heat / one stage cool / electronic manual changeover rectanglar thermostat. 2ET117043 - Two stage heat / one stage cool / electronic manual changeover, nonprogrammable thermostat. 2ET117002 - Two stage heat / onestage, electronic programmable, manual changeover with built-in anti-short cycle protection. 6 Unitary Products Group

NOTES: Unitary Products Group 7

MATCHING INDOOR COMPONENTS Add-On Coils - For Furnace Application G1UA G1NF G1NA G2FD* MULTI-POSITION (Upflow, Horizontal, Downflow) * Available with or without a factory installed horizontal drain pan option. Air Handlers - For Non-Furnace Application DOWNFLOW HORIZONTAL BLOWER N1AH or N1VS HORIZONTAL F2RP or F2FP FAN COIL COIL G2FD Unitary Products Group P.O. Box 1592, York, Pennsylvania USA 17405-1592 Subject to change without notice. Printed in U.S.A. Copyright by York International Corporation 1998. All Rights Reserved. Code: EBY, EGY Supersedes: (198)